Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹24.3 L+₹53,446 (2.25%)Rejected-Finance 148 SANGHI STREET MHOW MP 453441 | MHOW | INDORE | MP | 453441 | L2 | Rejected-Finance High Rates | |
| 3 | L3₹24.7 L+₹1.0 L (4.26%)Rejected-Finance 498 GANNAUGHT ROAD MHOW MP PIN 453441 | MHOW | INDORE | MP | 453441 | L3 | Rejected-Finance High Rates | |
| 4 | L4₹25.5 L+₹1.7 L (7.32%)Rejected-Finance | L4 | Rejected-Finance High Rates | |
| 5 | L5₹26.2 L+₹2.4 L (10.2%)Rejected-Finance | L5 | Rejected-Finance High Rates |
Tender Value
₹25.4 L
EMD Value
₹50,760
Closing Date
25 Aug 2021, 6:00 pmClosed
GE (MCTE) MHOW
GE (MCTE) MHOW (MP) 453441
ADDITION/ALTERATION OF TO BUILDING NO WB-165 OF MCTE, PROVISION OF COVERED PARKING SHED AT MCTE, PROVN OF EIGHT OPEN SHED INFRONT OF CERTAIN BLDGS ON VIKRAM PATH AND OLD SHIVAJI MARG AREA AND PROVN OF UTENSILS PLATE RACK AT HEMA AND THIMMAYA LINE
2021_MES_449864_2
GE(MCTE)/MHOW/13(T) OF 2021-22
Open Tender
Civil Works
Works
180 days
GE (MCTE) MHOW
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) MHOW
₹50,760
Yes
8 Oct 2021
3 Aug 2021
27 Aug 2021
3 Aug 2021
25 Aug 2021
10 Aug 2021
Amount
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles.
M & L vitrified ceramic tiles light shade 8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed.
-ditto- but on vertical surfaces such as skirting incl incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
Taking down Chowkats or frame with shutter ( without taking off shutters from the frame) exc. 1.5 sqm but exc 4.0 sqm each
Dismantling wrought iron or mild steel work of any description not otherwise described complete all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description ,over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Cutting holes in brickwalls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc half brick but not exc one brick as required
S & F 605 x 605 mm Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre incl fixed to Hangers 6 mm dia. G.I. (upto 200mm length) adjusting level fixed to roof slabs by means ofceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engr-in-Charge
M & L 8 mm thick size 595 x 595 mm Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre designer ceiling tiles with different shades for fixing in 605mm x 605mm grid (Frame work for ceiling shall be measured and paid separately)
M&L preparation of new plaster/concrete surfaces of wall and applying two coat of distemper oil emulsion incl primer all as directed by Engr-in-Charge.
S&F powder coated aluminium sliding window three track with two glass shutters using 5.5 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperature 1.61 mm using aluminium powder coated section aluminiuj cleat, PVC track, bearing, handle, lock, rubber beading etc complte fittings. Note Size of aluminium section are as under :- (i) Three track top and vertical - Jindal main-2010 section No 20621 or equivalent as appoved by GE (ii) Three track bottom- Jindal main-2010 section No 20620 or equivalent as appoved by GE (iii) Shutter vertical section- Jindal main- 2010 Section 20738 or equivalent as appoved by GE (iv) Shutter top and bottom - Jindal Main-2010 Section 20736 or equivalent as appoved by GE (v) Shutter vertical middle (interlock) -Jindal Main-2010 section 20737 or equivalent as appoved by GE (vi) Three track top and side - Jindal main-2010 section No 20621 or equivalent as appoved by GE
S&F 6 mm thick exterior grade High Pressure Laminate Sheet (HPL) of max size 4' x 8' as fixed at all heights with aluminum frame work section 25 x 38 x 1.6mm thick rectangle tube of grid size 1200 x 600 mm and fixing the grid with aluminum cleat angle of size 19 x 19 x 2mm on walls with required size of screws /rivets and PVC rawal plugs and finally joining the grooves with suitable materials all as specified and directed. (Make Finilex or equivalent.
Excavating in post holes in hard/dense soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface etc complete.
Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
M & L for Cement concrete Type C2 (1:3:6) using 40mm graded stone aggregate in filling for post holes all as specified and directed.
S & F mild steel work as in main and cross beams, hip and jack rafters; purlins, vertical sections, where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confiring to Fe 410-W (Gde-E 250 ( quality A) all as specifed and directed by Engr-in-Charge.
S & F mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, incuding all lattice bars, stiffeners, gussets plates etc. confiring to Fe 410-W (Gde-E 250 ( quality A)
S& F mild steel works in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted , bolted or welded attachment .confiring to Fe 410-W (Gde-E 250 ( quality A)
S&F Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as in ridges valley gutters etc all as specified and directed by Engr-in-Charge
M & L for preparation of new iron or steel surfaces of any description, over 10cm in width or girth,not applying two coats of synthetic enamel paint over a coat oxide zince chrome primer complete otherwise described
M & L for 100 mm thick cement concrete 1:4:8, type D2, with using 40 mm graded stone aggregate as in sub base to floors etc as specified and directed.
M & L for Rubber Mounded Chequered cement concrete tiles 400Cm x 400 Cm x 30 mm thick over and including 15mm thick screed bed in CM 1:6, set, jointed with grey cement and pigments and pointed in neat cement slurry in floors complete as directed and specified.
M&L for 100 mm thick PCC type C2 (1:3:6) using 40 mm graded stone aggregate) in path , paving , hardstanding etc, complete all as specified and as directed by Engineer-in-Charge.
M&L Machine coloured Rubber Moulded pressed precast concrete interlocking paver block any shape and size colour rubber finishes in top over confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments over and including 30-40 mm thick sand cushoining
S&F of Size Stainless Steel Kitchen Plate Rack includings arrangement/joining of all accessories and hanging to wall for utensils for kitchen size 31" x 24" x 10" complete as as specifed and directed. Make Prayag Cat part No P-346 or equivalent
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, sockets ,ceiling rose, light fittings etc, and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully copper/aluminium sub-main wiring any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
Taking down carefully MCB DBs/sheet metal earth plug socket any size and any type including MCBs any type and making good the disturbed surface of walls and floors etc all as directed by Engr-In-Charge.
M&L for concealed point wiring with PVC insulated and unsheathed, single core FR cable of size 1.5 sqmm stranded copper conductor, 1100 Volt grade, drawn into and including PVC rigid conduit not less than 20mm dia, medium grade, ISI marked with and including 1.5 Sqmm unsheathed green colour stranded copper conductor FRLS cable for continuous earth wire and including sunken pressed steel concealed terminal boxes of suitable size made out of 1.2 mm thick sheet covered with 2.6 mm thick white hylam sheet cover of suitable size for mounting switches/sockets/fan regulators or Modular flush box for mounting modular switches/sockets/regulators etc including cutting chasing in wall and making good disturbed surface with existing colour complete all as specified & directed for the following.
(a) One light/fan point controlled by one switch
(b) One socket outlet 2/3 pin 5 amp, multipurpose on same board with other switches
(c) One switch/socket outlet point 2/3 pin 5 amp multipurpose on independent board
All as per Item No 4 above, but with FRLS cable 2.5 sqmm stranded copper conductor for switch/socket outlet 5 Pin,15 Amps multipurpose controlled with 2.5 sqmm copper conductor FR cable as continuous earth wire of green colour on independent board.
Supply & fix in repairs/replacement, modular switch One-way 1-Module, 6 amps, 230V AC all as directed by Engr-in-charge.
.-ditto- all as per item No. 06 but flush type, 16 amps all as directed.
Supply & fix in replacement modular socket 2/3 pin combined 6 amp,2 Modul, all as directed by Engr-in-charge.
Supply & fix in replacement modular socket 2/3 pin combined 6/16 amp,2 Module, all as directed by Engr-in-charge.
Supply & fix in replacement modular bell push,flush type 6 Amp,1-Module 220 V,all as directed by Engr-in-charge.
Supply & fix in repairs/replacement modular fan step regulator 2- Module complete,all as directed by Engr-in-charge.
Supply and fix in repairs/replacement,ceiling rose, 3 phase,polycorbonate isolated body for surface type, three terminals.
Supply and fix in repairs white finished single mounting modular plates sutable for modular accessories of following sizes as per specified and directed by Engr-in-charge.:(Make:- Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS).
(a) Sutable for 1/2 modules
(b) Sutable for 3 modules
(c) Sutable for 6 modules
(d) Sutable for 8 horizontal modules
S&F for Energy saving suspention (Pendant) luminaires 28 W with efficient lenc optic ensured optimised and unparallel light distribution luminaire for aesthetically appearing down light application with all neceessary hanging arrangements incl Provn of three core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal, grooving with proper finish and making good, disturbed surfaces complete all as specified and as directed. Make : Bajaj cat No BPCS28WLED4FLWH
S&F for energy saving recess/surface mounted luminaire 36/40W, high efficiency PMMA diffuser gives soft glare free light, suitable for 600X600 mm ceiling cut out, recess mounted 36W LED luminaire in MS housing (2'X2') incl Provn of three core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal, fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all fixing arrangement complete all as specified and as directed.
M&L for Sub main wiring in repairs with two runs of single core FR PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 4.00 sqmm cable,one run of 2.50 sqmm cable and one run of PVC conduit will be measured as one unit.
M&L for Sub main wiring in repairs with two runs of single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wall all as specified and directed. Note:- Two runs of 6 sqmm cable,one run of 4.00 sqmm cable and one run of PVC conduit will be measured as one unit.
Supply and fix in repair MS down rod 'medium grade' 15mm dia,in length of segments of required size of each down rod as per site requirement,including all fixing arrangments like hooks, clamps, nuts, bolts etc for hanging the ceiling fan at site, complete with making split holes, cut or threads at both end of pipe as required for hanging of Ceiling fan incl. painting of down rod with two coats of synthetic enamel white colour paint over one coat of primer complete all as specified and directed.
Supply and fix in repairs double door SPN DBs 12 ways of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete.
S & F in repairs MCB SPN 6 to 32 amps 10 KA, 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
M/S Ashish Construction
M/S GARG CONSTRUCTION
Goyal Construction
M/S UnitedConstruction
Jamna Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .