Loading…
Loading…
Tender Value
₹19.6 L
EMD Value
₹39,160
Closing Date
26 Sept 2026, 6:00 pm
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR AND MAINTENANCE OF CENTRAL HEATING SYSTEM INDOOR AND OUTDOOR UNITS AT DIHAR LEH
2026_MES_787668_1
GE I R AND D/CHD-65/2026-27
Open Tender
Civil Works
Item Rate
240 days
Leh
As per tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹39,160
Yes
3 Sept 2026
3 Sept 2026
28 Sept 2026
3 Sept 2026
26 Sept 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches for Soft/ dense soil n.exc 1.5m wide and n.exc 1.5m depth 1.5m for laying cables/poles, stays ,foundation etc and getting out in any type of soil complete all as specified and directed. | 62 | Cum | - | - |
| 2 | Returning filling including spreading, leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed. | 55 | Cum | - | - |
| 3 | Removal of excavated material (soil) to a distance n.exc. 50m and depositing where directed at a level n.exc 1.5m above from the starting point complete all as specified and directed. | 7 | Cum | - | - |
| 4 | Material and labour for cleaning and removing dirt particle and decarburizing boiler of central heating plant of Capacity 1 to 4 Lack K cal / hrs including replacement of wear and tear gaskets, unserviceable nuts,bolts and washers and making all joints for pipes leakes proof with replacement of minor accessories of glycol / water circulating systems etc for effective function of the plant complete all as specified and directed. | 12 | Each Job | - | - |
| 5 | Material and labour for cleaning/removing dirt ,impurities particle from fuel tank of size 1.25M x 1.25M x1.25M including replacement of deffective gaskets, unserviceable nuts,bolts and washers and making all joints leaks proof using necessary accessories complete all as specified and directed. | 6 | Each Job | - | - |
| 6 | Tools and plants alongwith labour only for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous sreviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge all as directed at site.
Note :- i) . Attending any complaints of different nature in a single day will be considered as one job.
ii) Any kind of replacement of major items shall be measured and paid for separately under respective item of schedule 'A' as supply and fixing in repair/replacement
iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc will be completed round the clock by suitable trademen (welder with suitable T & P,(including portable heating materials)-01,Skilled mechanic of CHS-01, Plumber/Fitter with helper-each o1, Supervisor-01 as per descreation of Engineer-in- Charge. | 120 | Each | - | - |
| 7 | Supply and fixing in replacement of Sequence controller for heating plant suitable for 4 Lakh Kcal for thermax plant complete all as specified and directed. | 2 | Each | - | - |
| 8 | All as per serial item No 07 above but for 2 lakh K/cal. for thermax plant complete all as specified and directed. | 1 | Each | - | - |
| 9 | Supply and fixing in replacement of PVC coupling assembly from fuel pump assly to motor suitable for 1 to 4 Lakh K/ cal boiler complete all as specified and directed for thermax plant. | 1 | Each | - | - |
| 10 | Supply and fixing in replacement of water pressure guage 0 to 5 Kg/cm2 complete all as specified and directed. | 2 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_882788.xls
BOQ • 0.30 MB
Tenderdocuments65.pdf
Tender Documents • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .