| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹16.8 L+₹1.8 L (12.2%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹17.3 L+₹2.3 L (15.4%)Rejected-Finance | L3 | Rejected-Finance SINCE NOT L1 | |
| 4 | L4₹17.6 L+₹2.6 L (17.1%)Rejected-Finance | L4 | Rejected-Finance SINCE NOT L1 | |
| 5 | L5₹18.3 L+₹3.3 L (21.9%)Rejected-Finance PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Jun 2020, 6:00 pmClosed
GE DEOLALI
GE DEOLALI , 422401
REPAIRS REPLACEMENT IMPROVEMENT TO SECURITY STREET LIGHTS AT MES INSTALLATIONS, VARIOUS REMOTE ANCILIARY UNITS , DHARNA COLONY ETC AND REPAIRS OVERHAULING OF DG SETS SWIMMING POOL OF VARIOUS RATINGS ALONG WITH REQUIRED ACCESSORIES UNDER THE AOR
2020_MES_324877_4
8828/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE DEOLALI
CLASS E cat b i
8 documents required · 8 mandatory
₹500
GE DEOLALI
₹30,000
Yes
15 Jul 2020
27 May 2020
15 Jun 2020
27 May 2020
13 Jun 2020
27 May 2020
Amount
Taking down defective street light fittings of any type and any wattage. for Inspection / checking /finding faults /repairs/replacement of parts, including thorough cleaning of acrylic perpex cover and refixing the same in existing position after carrying out necessary repair/replacement of parts, complete including testing etc for smooth functioning all as specified and directed. Note :- (i) Repairs will be measured separately & Replacement of parts( after taking down fitting) required will be measured separately in relevent items of schedule as supply.
Supply only ballast for 250 watts for HPSV/MH fitting .
Supply only ballast for 150 watts for HPSV/MH fitting .
Supply only ballast for 400 watts for HPSV/MH fitting 400 watts .
Supply only ballast for 70 watts for HPSV/MH fitting.
Supply only ballast for 2x24 watt light fitting.
Supply only ballast for 2x36 watt light fitting.
Supply only Ignitor for 70/150/250/400 watts HPSV fitting.
Supply only PL-L lamp 36 watts for FPL fitting.
Supply only holder for 150/250 watts HPSV lamp fitting
Supply only HPSV lamp 70 watts
Supply only HPSV lamp 400 watts
Supply only HPSV lamp 150 watts
Supply only HPSV lamp 250 watts
Supply only lamp for FTL T5 24 watts.
Supply only Electronic ballast 40/36 watts for tube light fitting.
M & L for bracket made out of GI tubing 40 mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as directed at site.
S&F PVC insulated stranded unaroured Copper conductor cable 1.0 Sqmm flat/ round three core 1100 volts grade for street light complete all as specified and directed
Deweeding installtion premises by application of suitable chemicals like Glyco Phosphate solution 41% @ 2 ltr per acre all as directed at site
Taking down of High masts light and refixing it after replacing /repairing defective items all as specified and directed. NOTE:-All matertial should be paid seperately as supply only.
M & L for scrubbing out old paint,rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2'' size with white paint lettering on black base all as directed at site .(work shall be completed in the stipulated period as direced by Engr -in -charge ).
Taking down old u/s street light fitting and deposited to Age E/m store and S&F new Endura pearl plus 60 Watt LED Luminaries with high power LED as light source of 60 W with built in surg protector, IP 66 protection and impact resistance of IK07. Make Havells Cat Part Num:- SL60WLED757SASYTOPC or Equivalent model in Wipro/Bajaj/ Philips
Supply & fix Thermo plastic street light junction in repairs box of size 300 X 200 X 125 mm with 4 way connector mounted on epoxy insulators for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. Make :- Sintex / National.
Supply & fix Thermo plastic street light junction box in repairs 300 X 200 X 125 mm wiith MCB TPN 32 Amps for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. Make :- Sintex / National.
S &F in replacement Daily dial type time switch model FM1 / Quartz Daily DIN Mounting suitable for street light auto On-Off circuit Make L&T Cat Pt No- J648B1 or equivalent of Siemens/ Legrand
S &F in replacement 3 Phase 50 Amps contactor 240Volts AC supply suitable for street light auto On-Off circuit Make L&T, Model - MO (CS94572)/MNX-50 or eqivalent of Siemens/ Legrand
M&L in replacement of u/s MCCB of 4 pole 63 Amps 415 Volts with breking capacity 25 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of u/s MCCB of 4 pole 100 Amps 415 Volts with breking capacity 25 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of u/s MCCB of 3 pole 100 Amps 415 Volts with breking capacity 25 KA complete all as specified and directed by Engr-in-charge.
Comprehensive Maintenance / preventive Servicing of DG set of capacity 320 KVA Model KT-1150G Make : Kirloskar Cummins Ltd, water cooled type by the rep of authorised service centre of manufacturer. Note:- Spare parts required for repair/ replacement will be measured and paid separately under respective item of schedule 'A'.
All as Item No 30 above but 250 KVA capacity Model NTA 855G Make : Kirloskar Cummins(RCL), water cooled ( MH OT/ICU)
All as Item No 30 above but 140 KVA capacity Model No F-6SL 9088/6 SL 9088T Make : Kirloskar Oil Engine 6 cylinder, water cooled ( IT Division)
All as Item No 30 above but DG set of capacity 63 KVA Engine No 11220690983 Ruston & Hons by India Ltd, 4 cylinder water cooled. ( if authorised service centre is not located near by then by expert mechanics of DG set) ( MH Deolali DG set No - 1)
All as Item No 30 above but DG set of capacity 63 KVA Engine No 11220690980 Ruston & Hons by India Ltd, 4 cylinder water cooled. ( if authorised service centre is not located near by then by expert mechanics of DG set) ( MH Deolali DG set No - 2)
All as Item No 30 above but DG set of capacity 63 KVA Engine Model No 4 H 2443/0300011 Make Kirloskar Oil Engine, 4 cylinder water cooled (MH Deolali - Blood Bank.)
All as Item No 30 above but DG set of capacity 63 KVA Model 11776784 Make Kirloskar Cummins Ltd, 4 cylinder water cooled & carrying out the following:- (Fild wing area)
All as Item No 30 above but DG set of capacity 63 KVA Make Kirloskar Cummins Ltd, 4 cylinder water cooled .(PAO booster)
All as Item No 30 above but DG set of capacity 100 KVA Make Kirloskar Ltd, 4 cylinder water cooled. (Central filtration plant)
All as Item No 30 above but DG set of capacity 50 KVA Make Kirloskar Ltd, 4 cylinder water cooled (Smirch simulator & STP ).
All as Item No 30 above but DG set of capacity 63 KVA Engine model No 4H24430300011 Make Kirloskar OIL Engine 4 cylinder water cooled (KLP-136 Basantra hall).
All as Item No 30 above but DG set of capacity 63 KVA Engine model No 4H24430300011 Make Kirloskar OIL Engine 4 cylinder water cooled (KLP-133 command post).
All as Item No 30 above but DG set of capacity 63 KVA Engine model No 4H24430300011 Make Kirloskar OIL Engine 4 cylinder water cooled (Adm block SOA)
All as Item No 30 above but DG set of capacity 25 KVA. Make Kirloskar OIL Engine 4 cylinder water cooled (PAO Booster) (Note for item no. 30 to 43 please refer clause no. 25 of Particular specification)
Repair to battery charger for DG set battery suitable for charging 2x12 Volts 180 AH battery complete with replacement of DC Ammeter, indicator lamp, MCB and any other hidden part to make it fully functional.
Repair/ servicing of self starter Starter by replacement of carbon bushes, US parts & overhauling complete. of DG set 140 KVA capacity Make : Kirloskar Cummins (RCL),
Repair/ servicing of self starter Starter by replacement of carbon bushes,US parts & overhauling complete. of DG set of capacity 63 KVA.
Repair/ servicing of self starter Starter by replacement of carbon bushes, US parts overhauling complete. of DG set 320 KVA capacity Make : Kirloskar, Oil Engine 6 cylinder, water cooled,
Repair/ servicing of self starter Starter by replacement of carbon bushes, US parts & overhauling complete. of DG set 50 KVA capacity Make : Kirloskar, Oil Engine .
Dismantling the self starter of 250 KVA DG set Make- Kirloskar Commins Ltd after disconnecting all electrical and mechanical connection, transporting to work shop for rewinding with supper enameled winding wire of apropriate/ existing guage, varnishing, drying/backing , bench testingin work shop. transporting back to MES site, testing and checking the performance for trouble free and smooth functioning.
Supply & Fixing Battery lead with negative & positive brass terminal of suitable size with 2 M length of each lead all as directed.
S&F in repair ON LOAD change over switch 415V, 50Hz, Confirming to IS 13947-3, 200 Amps, 4 Pole. Make - L&T Cat Pt No CO22000OOOA or equivalent in standard/ legrand/Siemens
S&F in repair ON LOAD change over switch 415V, 50Hz, Confirming to IS 13947-3, 100 Amps, 4 Pole. Make - L&T Cat Pt No CO11000OOOD or equivalent in standard/ legrand/Siemens
Supply only engine oil SAE 20W40 superior quality Make: Castrol/ HP/IOC/ Servo/ BP/Shell)
Supply only the following parts suitable for DG set of capacity 320 KVA Model KT-1150G Make : Kirloskar Cummins Ltd, water cooled type.
a) Diesel filter element
b) Oil filter element
c) By pass filter element
d) Fan belt set
e) Automatic voltage regulator
Supply only the following parts suitable for 250 KVA capacity dg set Model No NTA- 855G. Make- Kirloskar Commins (RCL) 6 cylinder water cooled.
a) Diesel filter element
b) Oil filter element
c) Fan belt set
d) Automatic voltage regulator
Supply only the following parts suitable for 140 KVA capacity dg set 140 KVA Model No F-6SL 9088/6 SL 9088T Make : Kirloskar Oil Engine 6 cylinder
a) Diesel filter element
b) Oil filter element
c) Fan belt set
d) Automatic voltage regulator
Supply only the following parts suitable for 100 KVA capacity dg set Make : Kirloskar
a) Diesel filter element
b) Oil filter element
c) Fan belt set
d) Automatic voltage regulator
Supply only the following parts suitable for DG set of capacity 62.5 KVA Ruston & Honsby India Ltd, 6 cylinder water cooled.
a) Oil filter element
b) Diesel filter element
c) Radiator hose pipe set incl circlips clamp etc.
d) Carbon brush set
e) Fan belt set
f) Bridge Rectifier
Supply only the following parts suitable for DG set of capacity 50KVA/ 63 KVA Make Kirloskar Oil Engine, 4 cylinder water cooled
a) Diesel filter element
b) Oil filter element
c) Fan belt set
Supply only the following parts suitable for DG set of capacity 25 KVA Make Kirloskar Oil Engine, 4 cylinder water cooled
a) Diesel filter element
b) Oil filter element
c) Fan belt set
M&L for opening the cylinder head cleaning the carbon deposite,replacing the un serviceable parts, repairing, calibration and pressure testing, reassembling and testing the engine fortrouble free smooth fuctioning and smooth running of dg set of capacity 140 KVA Model No F-6SL 9088/6 SL 9088T Make : Kirloskar Oil Engine 6 cylinder, water cooled. Note- spare parts will be measured and paid separetally under the respective items of schedule.
Supply only the following spare parts (for Item Sr No-91) sutable for 140 KVA DG set of Model No F-6SL 9088/6 SL 9088T Make : Kirloskar Oil Engine 6 cylinder, water cooled.
a) Liner with O ring
b) Piston Assembly
c) Piston ring set
d) Packing set
e) Valve pair
f) Valve guide
g) Valve seat
h) O ring set
J) Air filter inner & outer
M&L for opening the cylinder head cleaning the carbon deposite, replacing the us parts, repairing calibration and pressure testing, reassembling and testing the engine for trouble free smooth fuctioning and smooth running of DG set of capacity 62.5/63 KVA, 4/6 cylinder water cooled. Note:- spare parts will be measured and paid separetally under the respective items of schedule.
Supply only the following spare parts (for Item Sr No-102) sutable for 62.5/63 KVA DG set of make Kirloskar cummins/ Ruston &honsby india Ltd.
a) Set of gasket
b) Set of O rings
c) Set of hose with clip
d) Set of sealing rings
e) Valve stem seal
f) Valve inlet and exhaust
g) valve guide
h) valve seat
l) Set of diesel pipe
j) Sets of copper washers
k) head gasket
l) C R bearing
m) C R bush
n) Set of fan belt
r) Set of piston ring
Dismantling the Alternator of 250 KVA DG set after disconnecting all electrical & mechanical connections, transportation to the work shop for rewinding the rotor & field windings with supper enameled winding wire of appropriate/ existing gauge ,varnishing, drying/ backing, bench testing in work shop, transporting back to MES site, re assembling, testing, & checking the performance and out put of alternator for trouble free & smooth functioning.
Dismantling the Alternator of 63 KVA DG SET after disconnecting all electrical & mechanical connections, transportation to the work shop for rewinding the rotor & field windings with supper enameled winding wire of appropriate/ existing gauge ,varnishing, drying/ backing, bench testing in work shop, transporting back to MES site, re assembling, testing, & checking the performance and out put of alternator for trouble free & smooth functioning.
Repair to inverter of capacity 2 KVA, input voltage 24 Volt DC and output voltage 220 ± 10% including replacing the unserviceable relays and other Accessories.
Suppy only the radiator coolant for DG sets of various capacities.
S&F 12 Volts 180 Ah battery for DG sets Make Exide batteries model No- XP-1800 or Equivalent for DG set
S&F 12 Volts 120 Ah/130Ah battery for DG sets Make Exide batteries model No- XP-1300 Equivalent for DG set
S&F 12 Volts 100 Ah battery for DG sets Make Exide batteries model No- XP-1000 Equivalent for DG set
S&F in repair OFF LOAD change over switch 415V, 50Hz, four pole of 300 Amps capacity make Standard/ Stanley/L&T
Supply only distilled water in the Lead- Acid battires
M&L for starting/ stoping solenoid valve sutable for 250 KVA DG set of Make Kirlosker cummins
M&L for starting/ stoping solenoid valve sutable for 63 KVA DG set of Make Kirlosker green
M&L for repairing the doors of sound proof canopy of DG sets by replacement of door hinges. Note: replacement of 01 set ( 02Nos) Hinge will be measured as one job.
Comprehensive Maintenance / preventive Servicing of oil fired incinator of capacity 80 kg/hrs including replacement of filter element, fuel ejection nozzle & fuel control solenoid valve etc all as directed at site.
M&L for cleaning internally Radiators of DG set of capacity 320/250/140 KVA using cleaning agent all as specified and as directed at site.
M&L for cleaning internally Radiators of DG set of capacity 100/63/50/25 KVA using cleaning agent all as specified and as directed at site.
S&F ON/OFF switch operated by key of control panel sutable for 63/100/140 KVA DG set
S&F generetor Controller KG934V1 (Electronic Monitor Systems) for 63KVA DG set. Make Kirloskar/koel, model- KG934V1
Supply and fix DIN type HRC fuse link of capacity 400 Amps Suitable for Type FN 630/800 / FNX 630/800 S-D-F & for HB 800 Fuse base
Supply and fix mounting base for DIN type HRC fuse link of capacity 400 Amps Type FN 630/800 / FNX 630/800 S-D-F & for HB 800 Fuse base cat No- SK91051 make L&T
Supply and fix power contactor 400 Amps with 2NO+2NC and side add on auxiliary contacts with and including spreeder link opereting on 415 Volts, 50 Hz supply with coil voltage of 415 Volts. Make L&T Model No-MNX 400 cat Part No CS94144 or equivalent in ABB/ Legrand /Schneider/ Siemens
Repair to AMF panel of 250 KVA DG set by replacement of us parts such as control wiring, indicating lamps- 06 Nos, Start & Stop Push Buttons, AC Timer 230 Volt with 2 NO+2 NC -- 2 No, Engine Start relay 12/ 24 V- 1 No , Digital Ameter 3Ph 0-500A-01 Nos, Digital Volt Meter 3 Ph 0-500 Volt- 01 Nos
S&F in replacement 20 Watt New generation energy saving and environmental friendly long life LED Security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07. Make- Havells, Model - ENDURAPEARL SL20WLED757SASYTOPC or Equivalent in Wipro/Bajaj/ Philips
Supply and fix coil for MNX 50/MNX 70/MNX 80 contactor Cat Pt No CS94192 make L&T, ABB / Siemens
Supply and fix in repair MCB TPN 32 Amps, 240 volts complete all as specified and as directed.
Supply and fix in repair MCB TP 32 Amps, 240 volts complete all as specified and as directed.
Supply and fix in repair MCB SP 6 Amps, 240 volts complete all as specified and as directed.
Supply and Fix Driver for 120 Watt LED street light fitting of Model No- LHETAXU7PA6J120, Make Havells or equivalent make in philips / wipro & bajaj
Supply and Fix Driver for 20 Watt LED street light fitting of Model No-ENDURAPEARL SL20 WLED757SASYTOPC , Make Havells or equivalent make in philips / wipro & bajaj
Supply and Fix Driver for 60 Watt LED street light fitting of Model No--LHETBXU7JA7B060, Make Havells or equivalent make in philips / wipro & bajaj
Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:-
a) 4 core 10 sqmm
b) 2 core 10 sqmm
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
M&L for unwashed rever sand for providing cushioning to under ground cable with a layer of 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work for coping of poles etc all as specified and directed.
S & F Valves, Sluice, flanged of class 1.6 PN supplied and installed complete of size 150 mm
S & F Valves, Sluice, flanged of class 1.6 PN supplied and installed complete of size100 mm
Construction of brick masonry valve pit in CM 1:4 for Sluice valve including plastering in CM 1:4 15mm thick, PCC in foundation 100 mm thick 1:4:8, Excavation and earth work in any type of soil, MS sheet cover 3mm thick sheet with angle iron frame 40x40x6 mm thick with locking arrangement painted with two coat of anti corossive paint over one coats of zinc chrome primer of 1200x1200x900mm (type 'internal dimmensions').
Note: Amount of sch of credit of Rs.39,528.00 will be deducted from total amount of BOQ.
DURGAI ELECTRICALS
Mayur Electro Enterprises
P C DAVE AND SONS
KOYNA ENGINEERS PVT LTD
n.p.shinde electricals
LOKMANYA ENTERPRISES
M/S B R BHALERAO
AGRAWAL ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .