| 1 | L-1₹75.2 LAccepted-AOC WARD NO 9 HOUSE NO 41 ARYA SAMAJ GALI UDHAMPUR 182 101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹79.0 L+₹3.8 L (5.09%)Rejected-Finance | L-2 | Rejected-Finance being other than L-1 | |
| 3 | L-3₹80.9 L+₹5.7 L (7.60%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L-3 | Rejected-Finance being other than L-1 | |
| 4 | L-4₹89.3 L+₹14.1 L (18.7%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-4 | Rejected-Finance being other than L-1 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
23 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182 121
CONSTRUCTION OF NEW STORAGE ACCOMODATION OF GP-VI AT CSD DEPOT UNDER GE (NORTH) UDHAMPUR
2020_MES_382050_1
CWE/U(N)-73/2020-21
Open Tender
Civil Works
Lump-sum
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE NORTH UDHAMPUR
₹1.6 L
Yes
10 Feb 2021
29 Sept 2020
25 Jan 2021
29 Sept 2020
23 Jan 2021
11 Jan 2021
60 days
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
INTERNAL WATER SUPPLY (SCHEDULE 'A' PART-II) Lump sum price worked out by the Contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part- II
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- III (Sec-I)
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-II) SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Slim linear LED lighting fixture 18/20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
S&F of decorative ultra slim linear LED lighting fixture 10/12 watt LED complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated 2 core flexible cable from ceiling rose to fitting by using extra length flexible cable 2 core other than provided by manufacture complete all as per directed by Engr-in- charge.
Bulk Head Light 9/10 watt LED energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
Exhaust fan AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty, complete all as specified and as directed by Engr-in-Charge.
Sub Total
PATH (SCHEDULE 'A' PART-IV) (SEC-I) Lump sum price worked out by the Contractor for “Path” as listed in Schedule ‘A’ Part- IV .
PATH (SCHEDULE 'A' PART-IV) (SEC-II) SCHEDULE `A' PART-IV, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Solar delineator of following specification : Solar delineator made of Polycarbonate and toughened aluminium alloy body, Height of Mild steel powder coated pipe - 1000mm and dia 47mm, Height top fitting - 145mm, Dia-80mm, Comprises of 4 super bright LEDs which give 360 degree viewing, Solar panel - 2.5V, 120MM (APPROX) 1.25V rechargeable battery-1 No including fixing with PCC block (size 30x30x30cm) of PCC 1:2:4 type B-1 complete all as specified and as directed.
Supply and fixing Convex mirror of 800mm dia, made of polycorbonate material provided with 50mm mild steel medium weight pipe post, duly powder coated fixed on ground with PCC 1:2:4 type B-1 of block size 60x60x60 cm including excavation earth work & removing excavated soil to a distance n.exc 50m, complete all as specified as directed by Engr-in-Charge.
Sub Total
AREA DRAINAGE (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “Area Drainage” as listed in Schedule ‘A’ Part- VI
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-VI) (SEC-I) Lump sum price worked out by the Contractor for “External electrification” as listed in Schedule ‘A’ Part- VI .
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-VI) (SEC-II) SCHEDULE `A' PART-VI, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Sub Total
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-VII) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- VII .
DEMOLITION (SCHEDULE 'A' PART-VIII) Lump sum price worked out by the Contractor for “Demolition” as listed in Schedule ‘A’ Part- VIII .
SEWAGE DISPOSAL (SCHEDULE 'A' PART-IX) Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part- IX.
SEWAGE DISPOSAL (SCHEDULE 'A' PART-IX) (SEC-II) SCHEDULE `A' PART-IX, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Advance septic tank 5000 litre per day suitable to retain micro organism long enough to digest the organic waste by 70% of BOD reduction from final out let, including inlet and out let pipes of 100mm size and 50 mm vent pipe, internal piping, manhole cover etc and including necessary excavation & earthwork in any type of soil and removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by the Engr-in-Charge. Make : Sintex Code No PWTS-AM-500-01/ or equivalent approved by GE.
Sub Total
jyoti parkash sharma
R K BUILDERS
SHIVAE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .