Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.8 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹13.3 L+₹56,050 (4.39%)Rejected-Finance 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹14.0 L+₹1.2 L (9.41%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | 3 | Rejected-Finance Not Lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
1 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar Pin - 152116
Repair/Maint and cleaning of sewage installations at Military Station Abohar
2022_MES_499463_1
GE ABH-65/21-22
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (ii) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹36,000
Yes
28 Feb 2022
5 Jan 2022
3 Feb 2022
5 Jan 2022
1 Feb 2022
19 Jan 2022
60 days
Amount
SCHEDULE 'A' SECTION I
periodical maint of equalizing tank of size 4.7 meter dia and up to 10 meter deep of sewage water tank and removing /cleaning of tank by scrapping with wire brush or any other means of walls and bottom of tank and removing the sludge /silt/sand/fungus etc deposited inside the sumps /tanks with buckets and depositing where directed , including removing media of settel down and making good the patches on walls internally or externally in cement mortar 1:3 where rquired and followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surface including writing the date of cleaning in white colour on black , background on external walls complete all as specified and directed by Engr-in-charge.Note : Contractor will be responsible for all safety precaution of worker.
All as per Item No. 2 but cleaning of Screen chamber 1 and 2 of size 5.20 meter x 3.10 metr x 1.8 meter of sewage treatment plant complete all as specified and directed
All as per Item No. 2 but cleaning of MBBR-Tank of size 6.3 meter dia and up to 7 meter deep of sewage treatment plant complete all as specified and directed
All as per Item No. 2 but cleaning of treated water tank of size 30 mtr x 15 mtr x 3 meter of sewage treated water tank of sewage treatment plant complete all as specified and directed
All as per Item No. 2 but cleaning of clarifier tank of size 8 mtr dia and up to 7 mtr deep with chemical cantact tank of sewage treatment plant complete all as specified and directed
All as per Item No. 2 but cleaning of thicker tank of sewage treatment plant complete all as specified and directed
All as per Item No. 2 but cleaning of sludge tank of size 2.1 mtr dia and up to 3 mtr deep of sewage treatment plant complete all as specified and directed
Replacement of old unserviceable air difuser product tubular and non buoyant design, installed in aeration tank for evenly distributed five bubbles aeration. The perforation/slit size on the membrance surface 1.0 mm and 2.0 mm depending on air through put the pipe acraters suitable for intermittent operation of air flow within 3 to 8 NM3/h aerator and penctration of waste water in to the distribution header not to be permitted and replacement of entire twin difuser assembly to be retireved.Size of air difuser 63 mm dia x 100 mm long set silicon based membrane with antimicrobial coating PP support tube of 5 mm thick non bouyant design all as specified and directed.
supply and replacement of MBBR floating media to be made of using virgin HDPE raw material colour white/transparent of size 25 mm dia x 10 mm height and specific gravity 0.92 to 0.95 complete all as specified and as directed by Engr-in-charge.
Repair replacement of tube seteler media for secondary clairfier by using UV stablized PVC raw material colour black of size 120 x44 mm all as specified and as directed. Make: SBS Enviro/Cooldeck/Siemens/ Kaldness
M&L for servicing and overhauling of existing DMF(Daul media filter)and AMF filters of size 3 meter dia and 3 mtr length and welding nad inner outer painting complete including disconnecting of old existing pipe connections and removal of old existing filter media (gravel, sand etc.) one by one, washing media, removing sludge and all foreign materials. Setting aside usefull media for reuse and connecting new pipe lines of required size and lengthand replacement of nozells of existing size and lenth as per requirement complete all as specified and as directed.
Supply and laying of filter media for DMF(Daul media filter) of size 3 meter dia and 3 mtr length and ACF (activated filter media) as per existing size and requirred thickness of media one by one inluding commissioning and testing etc complete all as specified and as directed.
Repair/ replacement of broken parts of air compressor machines(3 Nos) i.e fan belt, bearing, impeller, oiling greasing and complete over hauling of 3 Nos compressor including two coat of enameled painting on compressor and motors, Structure and pipe lines complete all as specified and as directed.
Repair/ replacement of unserviceable parts of centrifugal pump set of capacity 20 HP i.e rewinding of motor 20 HP and replacement of pump shaft, impeller, bearing and rusted fitting connection acessories including cleaning, painting and over hauling etc complete all as specified and as directed.
Repair/ replacement of Butterfly valve PN 1.6 flanged complete of size 150 mm dia complete all as specified and as directed.
Repair/ replacement of Butterfly valve PN 1.6 flanged complete of size 100 mm dia complete all as specified and as directed.
M&L for Cleaning of sludge,soil,dirt from sludge drying bed removing the sludge/soil to a distance not less than 50 mtr and not exceeding 100 m from the sludge drying tank . Making dry the side wall, removal of all mud, grass, bushes alongwith and removing/staking the sameto out side incl scraping the wall surface with wire brush,cleaning the wall with fresh water complete all as specified and as directed . Note: Plastering ,PCC work , and painting,white wash will be measured and paid separetely.
S & F HDPE pipe ISI mark 110 mm dia pressure rating 6 Kgf/cm² including fitting complete all as specified and directed.
M&L for fabrication of iron stainer, water gate, ladder for raw water tank etc as required cross arms, bracings, supports,clamps structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge.
M&L for repair/maint of scrapper mechanism of clarifier tank with replacement of bearing,shaft coupling, mechanical seal, oiling,greasing including complete over hauling of motor and mechenism including painting etc complete all as specified and as directed.
M& L for taking down rotary pump set of sludge sump tank and cleaning ,change of shaft coupling, bearings, mechenical seal, oiling and greasing including complete over hauling of pump and painting and after repair refixing the same in the existing position connection etc complete all as specified and as directed.
M & L for lifting , taking out , dismantling and strip opening of worn out / defective non clog submersible electric motor of 5 HP/7.5 HP, 3 phase , 415 volts, taking out burnt startor winding , servicing cleaning of startor slots , bearing bushes etc. rewinding of startor coils with superior quality of copper enamel wire of existing size and specification including insulation material , varnisihing and drying complete reassembleing , testing installed and connected at original location complete all as specified and directed by Engr-in-charge. Note : transporation, lifting, change of U/S nut bolts and necessary concrete work shall be included in thequated rate.
All as per srl Item No. 23 here in beforebut 15 HP complete all as specified and directed by Engr-in-charge
Disconnecting electric connection dismantling / taking up electric motor 3 phase, 440 volts, 50 Hz of capacity 5 HP from existing foundation coupled with reduction gear removing to workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing of motors and redution gear ( 02 nos), key rubber shaft coupling ,impeller, varnishing reassembling and replacement of reduction gear parts as per requirement and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wireshall be ATLAS/Devi dayal/ BPL
Disconnecting electric connection dismantling / taking up electric motor 3 phase, 440 volts, 50 Hz of capacity 3 HP from existing foundation coupled with reduction gear removing to workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing of motors and redution gear ( 02 nos), key rubber shaft coupling ,impeller, varnishing reassembling and replacement of reduction gear parts as per requirement and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wireshall be ATLAS/Devi dayal/ BPL
M & L for rewinding of electic motor 1 HP and replacement of bearing complete all as specified and directed by Engr-in-charge.
M&L for distempering on cement surfaces wall with distemper oil emulsion(OBD) paint 1st coat complete all as specified and as directed.
M&L for distempering on cement surfaces wall with distemper oil emulsion(OBD) paint subsquent coat(2nd coat) complete all as specified and as directed.
M&L for joints, bend, Tee, elbow sockets,spigot etc suitable for ductile pipe of size 150, 250 mm complete all as specified and as directed.
S & F as in replacement Submersible cable of size 6 Sqmm complete all motors of sewage treatment plant and sewage pump house, complete all as specified and directed by Engr-in-charge.
collection of sample of sewage treated water from sewage treatment plant and testing it through Govt approved laboratory for testing the ph, COD(mg/l) TSS (mg/l) oil and grease (mg/l) & coliform MPN/100 ml complete all as specified and directed by Engr-in-charge.
Collection of sample of sewage Raw water from sewage treatment plant and testing it through Govt approved laboratory for testing the ph, COD(mg/l) TSS (mg/l) oil and grease (mg/l) & coliform MPN/100 ml complete all as specified and directed by Engr-in-charge.
S & F HDPE pipe ISI mark 150 mm dia pressure rating 6 Kgf/cm² including fitting complete all as specified and directed.
S & F HDPE pipe ISI mark 50 mm dia pressure rating 6 Kgf/cm² including fitting complete all as specified and directed.
S & F oil seal suitable for non clog submersible pump of capacity 5/7.5 HP complete all as specified and directed.
S & F oil seal suitable for non clog submersible pump of capacity 10 HP complete all as specified and directed.
S & F oil seal suitable for non clog submersible pump of capacity 15 HP complete all as specified and directed.
Cleaning of underground sewage treated water Sump at Bn-I, Bn-II and Bn-III , 175 MH and 89 Bde by means of dewatering the water, desliting and removing the muddy water and sludge from the tank,incl existing stacked soil held near the tank and remove out side to defance land from the Sump with the help of machinary as reqired . Making dry the side wall and bottom, cleaning the walls & bottom with fresh water incl removing grass,bushes & branches of plants(installation) complete cleaning of Sewage sump using man power as required.Minor repair like plastering is involved in this work, including epoxy coated paint complete all as specified and as directed.
M & L for desludging of silt/sludge deposited at the bottom of sludge sump well of sewage collection tank at sewage pump house no .1 ,2 & 3 Appx 10 meter deep and 7.5 meter breadth including removal of weeds, bushes & vegetation inside the tank after dewatering all as psecified and directed. Note : dewatering of tank shall be carried out by the contractor through gravity pumping to a certain level / extent with availavel source at site . the balance shall be pump out / drained out by the contractor at his own arrangement along with silt by means for which the cost is deemed to be included in the unit rate quoted without damaging the surface, floor, walls of storage tank.
Repair/ Replacement of Sluice valve ( Brass spindle) class PN 1.6 flanged type complete of size 150 mm dia including rubber gasket and connected Items complete all as specified and as directed.
SHIVANI ENTERPRISES
POOJA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .