Provision of Intermediate Block Signaling between Bhansi-Bacheli (BHNS-BCHL) Section of Waltair Division
SNTPVSKPOTBHNSBCHLIB0125~ECOR
SNTPVSKPOTBHNSBCHLIB0125
Open
Works - General
12 Months
Dantewada, Chhattisgarh
₹0
₹3.6 L
9 Jan 2026
18 Dec 2025
26 Dec 2025
Supply, Installation, Testing & commissioning of Mini SMPS based Integrated power system(IPS) confirming to RDSO specification No.RDSO/SPN/165/2012[Ver.3.0] or latest with latest 1 Amendment as on date of opening of the Tender and as per East Coast Railway Drawing No. CSTE/ECOR/TYP/2/11/AIt2 Including supply of additional spares as per approved drawing (1)Drawing of IPS for LC Gates with spare component,CSTE/ECoR/TYP/2/11 Alt.2 (2)Details of materials shall be supplied by the firm in each set. Drawings, details and documents enclosed in section-H of Tender document. Inspection by RDSO. Above/
D-SUPPY & INSTALLATION OF UFSBI 1497892.00 Below/P
Supply of dual redundant arrangement of UFSBI electronic exchange of vital relay 1 state pertaining to auto signalling etc.This system comprises for following subsystem; Electronics for UFSBI Interface as per IRS:S-104/2012 ver 0 (latest amendment).Equipment should be equipped to work on both OFC & quad cable along with Auto Change over modem. Spares as per the Annexure-A enclosed are also to be supplied. Inspection by RDSO.
Installation, testing &commissioning of dual redundantarrangement of UFSBI. Above/
E-SUPPY & INSTALLATION OF MSDAC 2738446.00 Below/P
Design, Manufacture, Supply of High Frequency Digital Axle Counter Multi-Section type complete system including evaluators, final track clearance relay for each track section, reset boxes, LV boxes, detection points, mushroom/housing (As per OEM) for the track side electronics and all other accessories fully wired to the ultimate capacity and fully equipped for all DPs/Nos of detection points (incuding interconnection cards to make common DP or dual DP) this as per 1 RDSO/SPN/176/2013 version 3.0 or latest. Inspection by RDSO. Drawings, Scope, details and documents enclosed in section-H of Special conditions of Contract. (This includes earthing of track device if required). Note: Unit to be read as DP (Detection point) instead of Nos. Break-up of Modules and accesseries to be supllied is to be submitted along with the offer as mentioned in section-H of special condition of contract. Supply 10% of spares (min.01number) subject to a fractional quantity to be rounded off to the next higher integer for all indoor & outdoor equipment of MSDAC hardware (Excluding earthing and maintenance & diagnostic terminal) as mentioned in section-H of Special Condition of Contract. Refer Section-H of SCC for supply related details of MSDAC.
"Supply of Tool kit for MSDAC with suitable tool box consist of following or as per OEM list.Inspection by representative of Railways. a) Fluke meter (Model 87B or higher) - 1no. b) Dummy 2 wheel - 1no. c) AdapterCard - 1no. d) Torque wrench -1no. e) Marking Jig - 1no. f) Card Puller - 1no. g) Set of Spanners - 1 set consisting of the following: i) Screw Driver -1no. ii) Nut driver - 1no. iii) FixSpanner - 1no. iv) Nose Piller -1no. v) IC cutter - 1no. vi) Wire Stripper - 1no. vii) Combination Plier- 1no. viii) Solering Iron -1no. ix) Soldering wire - 1 roll. Above/
F-DESIGN AND SUPPLY OF DRAWINGS 207439.00 Below/P
Design of Cable Route Plan (Mid Section) & submission of Three paper copies for approval For a Two line
Supply of Original Tracing of Cable Route Plan (Mid Section) after incorporating all the corrections. For a Two line
Supply of Amonia prints of Cable Route Plan (Mid Section) For a Two line
Supply of eight sets of Amonia Print of Approved Completion Cable Route Plan (Mid section). For a Two line
Design of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval For a Two line(if Auto signalling)
Supply of Original Tracing of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) after incorporating all the corrections. For a Two line(if Auto signalling)
Supply of ammonia print of approved circuit diagrams consisting of the items as mentioned below. For a Two line(if Auto signalling)
Supply of eight sets of Ammonia print of approved completion Miscelleneous 24 Diagrams consisting of the items as mentioned below (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram
Design of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval(goomty may be treated as one unit) For a Two line
Supply of Original Tracing of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) after incorporating all the corrections. (goomty may be treated as one unit) For a Two line
Supply of Amonia Print of Approved Location Box Drawings (Including Contact Analysis, Fuse Particulars etc).(goomty may be treated as one unit) For a Two line)
Supply of eight sets of Amonia Print of Approved Completion Cable Distribution Plan.
Alteration of Existing Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval
Alteration of Existing Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval
Supply of Original Tracing in A-3 size. Note: For Drawings larger than A-3 size payment shall be made in multiples of A-3 size.
Supply of Ammonia prints in A-3 size. Note: For Drawings larger than A-3 size payment shall be made in multiples of A-3 size.
Design of FPD & Submission of three paper copies for approval For a three-Line Station
Supply of Original tracing of FPD after incorporating all the corrections For a three- Line Station
Supply of Ammonia prints of FPD For a three-Line Station
Supply of eight sets of Ammonia print of Approved Completion FPD. For a three-Line Station Above/
A1-EXECUTION OF OUT DOOR WORKS 14080519.90 Below/P
Alteration of wiring in existing apparatus cases full/half. This includes supply of all 1 materials in connection with alteration in wiring. All the materials shall be supplied by the contractor at his own cost. This includes entry of cables, sand filling and masonry work involved. Lettering and painting to be done by the contractor at his own cost. Railway shall supply only relays and relay bases.
Fixing of RED/YELLOW/GREEN LED type lamp unit with current regulator. This includes taking the cable inside the unit, fixing of current regulator etc., complete wiring, fitting of 2 terminals, LED signal lamps, and dismantling of existing lamps and fittings as required. The painting and lettering of existing markers and numbering plate to be done by enamel paint. All materials including PVC wires, blanking stretcher, PVC flexible pipe, hylum strip (6 mm thick), terminals and all sundry materials are to be supplied by the contractor. Railway will supply LED Units.
Fixing of cable route marker as per drawing in" section-H" at a distance of 100 mtrs. Along the trench and at places where the cable route has taken diversion as per instruction of site 3 Engineer, this includes casting of foundation at site and fixing of the marker in the foundation made earlier at site as per railway directives and specifications, this includes proper curing of the structure, All materials required for this like cement, sand 15 mm chips and steel rod of ISI marks should be supplied by the tenderer.
"Excavation of trenches of following depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation of soil as well as disposal of extra soil 5 after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found. "
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and 6 width 0.3 Mts. at the bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including 7 transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
Transportation and fixing of perforated G.I. Pipes on bridges, culverts, drains or in trenches or any other place as per instruction of site Engineer with clamps at 1.5 mts. interval on 9 steel girder bridges or at places advised by site Engineer. This includes supplying of G.I. Pipes, 80/100/150 mm dia. Specn. No. IS:1239/2004, or latest medium gauge with threaded collars (Make - TATA /JINDAL) by tenderer. This also includes 100 mm thick concreting on GI pipes as required and instructed by site Engineer and all other materials required for the work shall be supplied by the tenderer.
Excavation of trenches including clearing of roots of trees etc. in rocky areas with 10 chisel cutting up to a depth of 0.6 M and width of 0.3 M at the bottom. This includes concreting (1 : 1.5 : 3) at a height of 100 mm after laying of cables as per instruction of site Engineer and back filling of trench by digging. All materials including cement and chips of size 20 mm. etc. to be supplied by the contractor. Route Kilo
Videography of work spots such as Signal/LB foundation, cable trench with depth indicators at every 10 mtrs with reference to landmark such as RE mast or hectometre post in MPEG or any other format specified by engineer in charge. The video recording shall be supplied in CDs/Pen drive.
Laying of Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with 12 left over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. to 1.0 mtr at places to be indicated by site Engineer for entering of cables inside 13 the building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.
Transportation and jointing (straight through and derivation) of PIJF/quad cables size TSF-IV as per Specn No. IRS: TC-31/96 & IRS 30/97. Jointing kits shall be supplied by the Railway. All other materials shall be supplied by the tenderer.
Alteration of wiring in existing Relay rack/ CT rack/composite relay rack. This includes 15 supply of all types of wires, eyelets, nuts & bolts, bunching material, ferrules, ARA terminals, fuses & fuse blockes by the contractor at his own cost. Lettering & painting to be done by the contractor at his own cost. Wire (RDSO Approved Sources) to be inspected by the representative of Railway before use.
Fixing of relay bases and wiring, bunching, fixing of relays, wiring in Old relay racks/location box and also carrying out any alteration in existing relay rack duly wiring and 16 connecting New to old and Old to old relays by standard wires (RDSO Approved Sources) as per Circuit diagram. Fuses of bases, condensers, ND fuses, LED indicator & its wiring for relay rack. All materials required for this work will be supplied by the contractor from RDSO Approved Sources. Relays with accessories will be supplied by the Railway.
Transportation of signal posts for multiple aspect color light signals, complete with signal units, bases, ladders and other fittings, excavation of pit, casting of cement concrete foundation, plastering as per Drg.No Con/SK/T/12, erection and fixing of complete fittings of the 2/3/4 aspect signal/signal posts including termination of cables, wiring, LED fixing, signal testing and 17 focusing. Name plate & marker and all other materials shall be provided by the contractor at his own cost. Required cement shall be supplied by the contractor. Arrangement of Screening to be provided by the contractor if required as instructed by site Engineer. Contractor shall prepare jointly with Railway Engineer at site and submit Signal Sighting report and Signal test report as per approved format of Railway. NOTE: (i) 50 % Payment shall be released after erection of signal post. Balance 50 % shall be released after termination of cable, wiring, painting, testing & focusing of signal. (ii) If foundation is available at site 30% of the cost is to be deducted.
"Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (full size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/CON/SK/16. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only from Railway stores at. Tenderer will supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm 18 thickness], wood plank board of good quality [minimum 3/4"" thick, Cement and transport all the materials to site of work at his own cost. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size. Note:-(i) If location box foundation is available at site 20% of the cost is to be deducted.(ii) 40% payment shall be released after erection of location boxes."
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (Half size) with fixing of E-Type lock, wiring, cable entry, termination clamping, 19 filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/Con/BBS/92/90. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only. Tenderer shall supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4" thick, cement and any other materials that are required for the work at his own cost. Contractor has to transport all the materials from store at his own cost to the work site. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor.2) All cables shall be terminated by providing copper eyelet of suitable size. Note:-(i) If location box foundation is available at site 20% of the cost is to be deducted.(ii) 40% payment shall be released after erection of location boxes.
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 20 mm nylon rope, pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by 21 mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.
[a] Compilation, preparation, printing, binding and supply of Draft station/Gate working rules both in English and Hindi using MS word software in computer on the basis of WRD, RCC and Front plate diagram of Panel/VDU with contractor's stationery, tools,plants & materials.
[b] Compilation, preparation, correction, updating, printing and supply of Final station working rules with contractor's stationery, tools, plants and materials. Note: Final SWR to be submitted in 2 sets for each station.
[c] Printing and supply of approved SWR with contractor's stationery, tools, plants and materials. Note: Approved SWR to be submitted in 26 copies for each station.
[d] Colour Printing and supply of Top covers with Station Photo for SWR with contractor's stationery, tools, plants and materials.
[e] Hardboard binding and supply of 26 copies of station/Gate working rules with contractor's stationery, tools, plants and materials.
[f] Supply of soft copy in CD of station/Gate working rules with contractor's stationery, tools, plants and materials.
Transportation, Installation, wiring, testing and commissioning of Data Logger system 512 digital input and 32 analog input as per specification No.IRS:S-99/2006 or latest at station and 28 goomtys. This includes (i) Changes in design of Data Logger for installation in electronic interlocking station (ii) Wiring and testing of protocol converter unit for EI station (iii) Modification in software and hardware if required and networking with other data loggers along with fault logic design. (iv) Wiring of all external relays to Data Logger as per RDSO guide lines.
Supply & Uploading of software for upgradation of Datalogger as per Spec. No. IRS:S- 99/2006. lnspection by representative of Railway.
"Installation and testing of Straight Portion track circuits including supply of materials as per directive of site Engineer. NOTE: (i) This includes drilling 9/32"" holes on rails, provision of bonding, fixing of track lead junction box, provision of track lead jumper wires, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling arrangement (if required), painting, lettering and numbering etc. This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by tenderer's insulation materials. (ii) Preparation of Track circuit history records and maintenance register duly recording the measurements in prescribed format jointly with Railway representative and handover all records to the Railway."
Transportation, Charging, installation, wiring of low maintenance Secondary cells as per manufacture's instructions and Railway's directive. This includes supply of distilled water and sulphuric acid by the contractor at his own cost. The un charged batteries with connector shall be supplied by the Railway. Materials including 3/0.29 PVC wires, battery connector , brass bolts and 32 nuts , PVC tapes eyelets, etc and all other materials shall be supplied by the contractor. Note: [1] Before completion of works contractor shall prepare jointly with Railway Engineer at site and submitt battery capacity test report as per approved format of Railway and hand over all relevant records to the Railway. [2] All the cells failing in the discharged capacity test in the Railway premises will be replaced by new ones free of cost. Railway Engineers decision shall be final. . Capacity test register ( binded size no. 10) in prescribed format shall be supplied by the contractor. In case of failure in capacity test tenderer will be responsible for fresh charging/replacement of the batteries.
"Wiring, testing and commissioning of overall circuits and ground gears of approved interlocking arrangement as per approved circuit diagram and Interlocking plan. This also includes making corrections/alterations in As Planned drawings and documents as per the execution at site. This includes Free home signal connection at site and SM's office, telephone connection in the 33 tents/goomties and any other communication arrangement for the Non interlocking at the station or as decided by the representative of Railway during non interlocking. The materials required for preparation of Free Home indication board will be supplied by the tenderer.This also includes painting and lettering of gears. Telephone , VHF Sets/Walkie Talkie sets will be supplied by railway. Note: In case of IBS : It includes overall testing and commissioning of IBS and both the end stations associated with IBS modification. "
Miscellaneous arrangement for NI period comprising of Provision of water-proof 34 temporary goomty/tent at both side of the station yard and at central panel building. Each goomties to be furnished with one iron table, six chairs, emergency light and mosquito repellent caps for NI staff, PA system, crowbar men for operating point and men for supplying water to tents.
Wiring and fixing of Surge Protection Device for 230 V AC input to PC, complete with enclosure and connected wire as per technical specification No:RS-SPD-5.
Wiring and fixing of Surge protection Device for 110V AC input to signals complete with connected wire .
Wiring and fixing of Surge protection Device for 110V DC input to IPS Goomty, complete with connected wire as per technical specificition No:RS-SPD-7.
Wiring and fixing of Surge Protection Device for 24V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
Wiring and fixing of Surge Protection Device for 12V DC supply complete with connected wire as per technical specification No: TS-SPD-3.
"Installation of lightening arrestor Class A device on the top of the building. the devices shall be installed at the height of about 3 mts from the roof of building using a G.I. pipe. The device shall be connected to the earth pit using the copper tape 25mmx1.5mm or better the copper tape shall be run firmly along the side of the mast with the help of the spacers. It shall also be 40 ensured that this down conductor shall not touch the building through out. The down conductor should be connected to the separate earth electrode as per Railway Board guidelines using exothermic welding. A counter shall be installed at an appropriate place to count the no of occurrences. All the accessories like spacers, welding material etc required for the installation shall be arranged by the contractor only. The installation of Lightning Arrestor should done by authorised representative of OEM."
Maintenance of all the installation of IBS including outdoor and indoor under an able and competent supervisor for a period of 60 days from the date the works handed over to traffic. Payment shall be released only on completion of residual works as pointed out by Railways. "i) During the above maintenance period contractor has to replace/repair any defect to the installation pointed out by the Railway administration at contractor's cost without endangering Railway safety and Safety rules. i) During the above maintenance period contractor shall comply all the residual works and carry out petty repairs and arrange attending of failures promptly by keeping artisan staff and helpers, conversant with signalling system tem muust be available round the clock." "iii) The 41 contractor shall supply & prepare all the required registers i.e. cable insulation register, Track History card, Battery History Register, Equipment History Register, Signal Lamp History Register, Joint S&T & P-way Inspection Register, Earth register, Axle counter reset register, axle counter channel voltage register, digital axle counter register, point testing register, emergency operation register (points, gate etc.) etc.and maintain the records neatly cabin-wise for signalling gears on standard Performa as per the directive of Railway administration for handing over the maintenance to the Open Line. Format of register should be as per the advice of the site Engineer. Each register of A-4 size of 50 pages one side/both side hard bound. 2 Nos of registers of each type mentioned above should be supplied. iv) The contractor has to supply all the registers mentioned above before taking Non Interlocking.
Erection of Rail posts size 3.0mtrs length approx with sole plate of size 40cm x 42 40cmx6mm (thickness) welded at the bottom, concreting the post (1:2:4) and painting (2 coats) as per directives of Railways. This includes welding 50mm dia Gl pipes, sole plate and fixing of EM socket box with the rail post. Emergency socket box and rail post with sole plate shall be supplied by Railways. All other materials including cement shall be supplied by the contractor.
Transportation, installation,testing and commissioning of Multi section digital axle counter (MSDAC) in complete system with all DPs of different track section configuration as per approved drawing. Axle counter device complete with standard accessories shall be supplied by the Railway. All sorts of terminals, sealed wires, condensers, resistances etc., HDPE pipes and all other 43 materials required for the above work shall be supplied by the contractor. This includes design, installation, testing, commissioning of MSDAC evaluation arrangement with all necessary modules cards, interface cables, software and other materials etc., execution of associated work for working of axle counter through OFC/Quad cable. The tenderer shall ensure that axle counters are installed by the OEM. Note:1. Unit to be read as DP(Detection point) instead of Nos. 2. Scope and the details of the execution of this schedule item should be as per section-H of special condtion of contract.
Transportation, Installation, wiring of Fuse Auto Changeover System (fuse Alarm 44 System) for monitoring health of various types of fuses with a railnet connectivity facility along with audio and visual indication as directed by the railway representative. Fuse Auto Changeover System (fuse Alarm System) will be supplied by Railway and any other materials required for the work will be supplied by the contractor
Fixing of Tie Bar Fencing panels supplied by Railways duly transporting to the site (Goomties/ Mid section Locations) from Centralised location. Cutting, drilling, jointing with nut and 45 bolts wherever required as per site requirement for protecting goomties /location boxes. After fixing of the tie bar, panels to be painted with two coats of aluminium paint and levelling the earth wherever required. All required materials other than tie bar fencing panels should be arranged by the contractor/agency
Excavation of pit to size of 450mmx 450mm x 450mm and concreting the same wi th1:3:6 aggregate 20mm fo r erecting the tie bar fencin g panels, curing and white washing the foundations.
Concreting (1:1.5:3) at a height of 150 mm & width of 0.3 m after laying of cables 47 where it is not possible to dig up to full depth of 1.2m/1.0m/0.8m in normal soil due to existing cables are in the trench, culverts, bridges. All materials including cement and chips of size 20mm. etc. to be supplied by the contractor. Payment for the depth of trench to be paid in proportionate to the rate specified for 1.2 mtr depth (excluding the concreting rate).
Installation and commisioning of DCDC converter (24-32V/10Amp) withcomplete wiring. Above/
A2-EXECUTION OF EI ALTERATION 2900679.60 Below/P
Installation/Alteration/Phase working, Wiring, testing and commissioning of complete Electronic Interlocking System (Distributed/Centerlized Configuration System with Hot Stand by feature) supplied as per Item Nos. 01 of Schedule-B-I including transportation from Consignee's depot to site of work. This includes execution of labour portion, Interface relay wiring, erection of relay racks, fixing of relays and associated work in relay room, proper fixing of Operator VDU 1 Terminals etc (The Relays for interface relays wiring will be supplied by Railways. The Contractor shall supply all other materials required for installation, wiring, testing and commissioning). NOTE:- 1) Installation & commissioning of Electronic Interlocking is as per Section-H of Tender document. 2) If it is phase working, other than initial phase design, supply of application logic required for phase working should be done by the Contractor agianst this item. 3) The work includes manufacture/ fabrication, supply and installation of SM's console and side table extension as per site requirement and as advised by site Engineer to accomodate VDUs, other S&T equipments and SM's stationary for operation of VDUs and execution of day to day work for operation of trains.
Design, preparation and supply of following ""AS PLANNED"" and ""AS LAID"" drawings and documents:original tracing of Gateway quality in AUTO CAD FORMAT. The tenderer has to provide proposed documents in original tracing to Railway for approval. After approval of the same final drawings are to be supplied. The work shall be executed only as per approved final 2 drawing. After completion of the work, the completion drawings in addition to the original tracings with softcopies are to be supplied in CD.Details of Design & drawings required to be supplied by tenderer is mentioned in Annexure. NOTE:Railway will supply: [1] Approved P-way Engineering Yard Plan. [2]Typical circuit diagram of one station of similar work on request by the contractor. [3] Standard guide lines issued by the Railway from time to time. The work is to be executed as per the Technical specification enclosed.
Factory acceptance test (FAT) with Railway officials, Only for Subsequent Phase working not for Initial working.
Site Acceptance Testing(SAT) with Railway officials, Only for Subsequent Phase working not for Initial working. Above/
A3-EXECUTION OF PI ALTERATIION 156840.00 Below/P
Alteration of existing panel,wiring and testing and commissioning of Control Panel Operation cum lndication Console as per Specn. No.S/36/87amendmend 2, complete with 1 termination of cable, painting and lettering as required. Raailway will supply Control Panel and multi coreindoor cables only. Tender shall supply Dominoes, buttons, keys,counters, MS Angle/Flat, Hylumsheet,Ms clamps, Bolts and nuts,PVC pipes, Screws, Sleeves,Pvc cables, PVC pipes, PBT terminals,Fuses,LEDS etc and all other materials required for the work at his own cost.
Design of Circuit Diagrams consisting of the items as mentioned below & submission 2 of Three paper copies for approval (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems. For a three-Line Station
Supply of Original Tracing of Circuit Diagrams consisting of the items as mentioned 3 below after incorporating all the corrections. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems. For a three-Line Station
Supply of Amonia Print of Approved Circuit Diagrams consisting of the items as mentioned below. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars. For a three-Line Station
Supply of Eight sets of Amonia Print of Approved Completion Circuit Diagrams consisting of the items as mentioned below. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems. For a three-Line Station Above/
A4-SUPPY & EXECUTION OF INDOOR & OUT DOOR ITEMS 7984587.00 Below/P
"Supply, installation, testing and commissioning of Maintenance free and permanent 1 earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0 and as per Technical Specification. Inspection By RITES. Note: latest guidelines/TAN of RDSO/Railway Board for earthing, bonding, surge protection & Lightening Protection system for S&T installations shall only be followed."
Supply ,transportation & installation of Optical Fibre cable joint enclosure and splicing of OFC (24 Fibre) and testing. OFC spicing shall be done in presence of Railway Representative.
Supply, transportation, erection, and grouting of Composite Relay Racks / Relay Racks / CT racks as per Drg.No. SK/DRG/OL/SER/192, SH1/2 (for Composite Relay Racks), Drg.No. SK/DRG/OL/SER/192, SH2/2 (for Relay Racks) and Drg.No. S&T/CON/HQ/VSKP/95/92 (for CT Racks) respectively, including fixing of racks, PBT terminals 1Way/6Way, ND Fuses, Bus Bars, Eyelets, 3 Hylum strips of required thickness [12 mm] as per length required at site, condensers and resistances etc., wherever required as per directions of Site Engineer. Inspection of Composite Racks / Relay racks/CT racks by Representative of Railway before use. Tenderer shall supply all the materials from RDSO approved sources such as PBT terminals 1Way/6Way, ND Fuses, Fuse blocks, Bus Bars, Eyelets, Hylum strips (12 mm thicknessn ISI Mark) condensers and resistances etc., and any other materials required for the work at his own cost. Inspection By representative of Railway.
"Supply, Transportation and Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments 4 as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A). Inspection By representative of Railway. NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint. " Running
Supply, transportation and fixing of MS ladder with suitable clamping arrangement & 5 associated masonary and smithy work in Relay room, equipment room, Battery room, Goomties and cabins etc. The MS ladder should be made of 1 X 1 (1/8/3 mm thickness) and MS flat size of 1 wide X 1/8 / 3 mm thickness. MS flat shall be provided at every 8apart. Width of ladder shall be 8. Tenderer shall supply all materials for this work. Inspection By representative of Railway before use. [RM=Running Meter]
Supply and installation of rack mounted 48F FDMS fiber part no.fms-1u 48FS 48FP 6 Raychem make including 48 Nos 0.2db FC/PC or SC/PC adaptors and 24 numbers 900 micron 1.5 meter FCPC or SCPC pigtails as per the site requirement. RDSO Spec No.: RDSO/ SPN/TC-037-2000 (Ver.3) or latest. Inspection By representative of railway.
Supply, transportation, and installation of RCC joint chamber with two piece top cover 7 and bottom cover with hole for drainage and cable entry as per drawing No.RCIL/ER/DRG02/06 (Section-H). This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soilas well as disposal of excess soil. Inspection by representative of railway.
Supply and installation of 64 input digital stack card for Data Logger. Inspection by RDSO.
Supply and execution of Earth Leakage Detector 8 Channel as per RDSO specification No: RDSO/SPN/256/2002 or latest. Inspection by RDSO.
Supply and installation of Rodent Repeller for covering the Relay Room and Power Room. Inspection By representative of Railway.
Supply & Erection of Polyolefin Cable Channel of size width (Int / Ext) 240/300mm, Length approx. 1 Meter,weight per mtr. Should be notless than 8 Kg (Top &bottom). Material- 11 Polyolefin-Engineering plastic with fireprotection class K-1 inaccordance with DIN 53438part -II, breaking loadMinimum >=12 Kilo Newtonor latest at room temperaturefor laying signalling/ Telecom/Power Cables, Channelattachable to each other withmale female swallow tailconnectors and having suitable detachable cove.Technical specification andtesting Parameter / Procedureas per RDSO- Ref No. STC/Cable- laying practices Vol-IVdated 09.05.2018.Inspection by RITES.
Supply, transportation, foundation, erection, painting and lettering of legend board, 12 stop board etc with 4" [minimum] GI channel iron support length as per G & SR , SEM and IP. This includes excavation pit as per approved drawing of the railway for casting of base foundation [ratio 1 : 3 : 6] . all the materials required for the above works shall be supplied by the contractor.
"Supply, placing and covering of RCC duct from Home to Home as per SCR Drg. No. 5778. "
Provision of Maintenance free perimeter Earth/Ring Earth for EI equipment, Relay 14 Racks, Power equipment along with the supply of all requisite materials as per Signal Engineering practice. Site specific Diagram of perimeter Earth/Ring Earth should be supplied to Railway for approval. Execution to be done as per the approved diagram. The Technical specification of Ring earth is enclosed in the technical specifications at Section-H. Inspection by RDSO.
Supply, installation, testing and commissioning of Automatic Fire Alarm & Detection system as per RDSO Specification No. RDSO/SPN/217/2018, Ver. 2.0 or latest and as mentioned in 15 section -H of Chapter -08 of this tender document. Inspection by RDSO. Note : 80% payment made after supply of material (this amount will be paid as per payment clause of supply of materials as para 16.3 of payment clause of Chapter -4 in Tender Document) and balance 20% payment made after commissioning of above work. "
Supply and placing of one row of fully burnt country bricks (B Class of size 220 mm X 100 mm X 60 mm approx.) horizontally breadth wise above the cables in 0.3m width trench without gap. Size of brick can vary subject to approval of engineer in charge. Above/
Relay plug in type , Style AC-LED: ALL aspect, AC lamp proving Relay unit with in 1 built current transformer type, slow release neutral line relay, 4F/4B contact , front and back contact metal to carbon shall be suitable for working in series with 110V AC, LED signal lamp rated at 15W conforming to RDSO Spec No- STS/E/Relay/AC lit LED/signal/09-2002, Amdt. 1, BRS : 941A, IRS: S :34 & IRS:S:23 {as applicable}. The interlocking code for this unit shall be ABDHK. Inspection by RDSO.
Supply of Relay AC Immune, plug-in type, style 'QNA1', Neutral line, 24V DC 8F/8B 2 contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS:931A, IRS: S - 60, IRS: S - 34, IRS: S - 23 (As applicable). Interlocking code: ABDGH. Inspection by RDSO.
Supply of Relay Non-AC immune , plug in type, style QN1, neutral line, 24V or 50V DC, 8F/8B contacts metal to carbon with plug board, retaining clip and connectors confirming to 3 BRS: 930, IRS: S - 34 and IRS: S - 23 (As applicable). The interlocking code for this unit shall be ABCDF for 24V and ABDEF for 50V. Inspection by RDSO. NOTE:- Depending upon the EI System, the operating voltage of the relay may change. Accordingly the quantity of relays of different operating voltage needs to be approved by railways on request of the OEM of EI System. The contractor shall supply the compatible relays at the same rate.
"Supply of Relay Non-AC immune, plug in type, style QN1, neutral line, 24V or 50V DC, 12F/4B contacts metal to carbon with plug board, retaining clip and connectors confirming to 4 BRS: 930, IRS: S - 34 and IRS: S - 23 (As applicable). The interlocking code for this unit shall be ABCDE for 24V and ABCEF for 50V. Inspection by RDSO. NOTE:- Depending upon the EI System, the operating voltage of the relay may change. Accordingly the quantity of relays of different operating voltage needs to be approved by railways on request of the OEM of EI System. The contractor shall supply the compatible relays at the same rate."
Supply of Relay AC Immune, plug-in type, style 'QNA1', Neutral line, 24V DC 12F/4B 5 contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS:931A, IRS S - 60, IRS: S - 34, IRS: S - 23 (As applicable). Interlocking code: ABDFH. Inspection by RDSO.
Supply of Signal colour light multi unit as per specification No: IRS: S 26/64 with latest 6 amendment as per RDSO Spec No. RDSO/SPN/153/2011 long range working on 110 V- AC 50 Hz complete 2-Aspect suitable for 140 mm dia. post as per Drg.No:SA-23003 A/M [Adv]. Inspection by the Rites.
Supply of Signal colour light multi unit as per specification No: IRS: S - 26/64 with 7 latest amendment as per RDSO Spec No. RDSO/SPN/153/2011 long range working on 110 V- AC 50 Hz complete 3-Aspect suitable for 140 mm dia. post as per Drg.No:SA-23002 A/M [Adv].Inspection by the Rites.
Supply of 4.6 Mts CLS tubular steel post specification No. IRS: S - 6/81 with latest Amnd to suit 140 mm dia base. Inspection by the RITES.
Supply of Signal Base 140 mm dia [Type tube] Drg. No. S - 2011/M. Inspection by the RITES.
Supply of Ladder 4.5 meter for CLS post as per Drg. No. SA: 23153 [Adv] Alt-1, specification No. IRS: S - 10/78 (with latest Amendment) consisting of ladder base, platform and guarding, ladder support complete. Inspection by the RITES.
Supply of Steel Apparatus case 'large Size' as per Drg. No - CON/SK/1/1/86 and Spec.No. IRS:S - 10/78 (adv) with latest amnd. with "E" type lock and key of ward No-32 with handle. Inspection by RITES.
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 12 mm inner dia, with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour-Orange. Inspection by the RITES. Note: If required, the DWC pipe shall be supplied split in two halves.
Supply of Emergency socket box of FRP Material approved type complete with 6 pin way female pin as per RDSO Spec. No. RDSO/SPN/TC/44/2002 Ver, 2 Amd 3 or latest amendment. Inspection by the Representative of Railway
Signal Post Telephone along with 12 V power supply unit with 7 Ahr Battery backup working on 220 V AC Input. Inspection by the Representative of Railway
Supply of PPTC (Polymeric Positive Temperature Coefficient) resettable fuses with 3 A, 60V DC ratings of Raychem RPG make or better. Inspection by the Representative of Railway.
Supply of Unbranded Grey CAT6 U/UTP cable for indoor use 305Mtrs. Category Name: CAT 6 Cable for indoor use. Model:D-Link. Inspection by the Representative of Railway.
Supply of Datalogger complete to spec No- IRS:S:99/2006 AMD. 3 or latest with configuration of 512 digital inputs and 64 Analog inputs with self power supply system, Dual Card serial to OFC Media Converter as required etc with networking facilities. Inspection by RDSO.
Supply of Thermo shrink jointing kit for underground cable as per Specn No. IRS: TC- 77/2012 [Rev.3] Amd 3. (Cable jointing kit shall be procured from RDSO approved sources only). Inspection by RDSO.
"Supply of 19"" 42 U covered racks complete with all fittings and accessories for housing SDH equipments, primary Muxs, krone modules for 60 channels (2 x 30), DDFs,for 30 channels and other equipments like runway ladders, fan tray etc completely wired and equipped with integrated protection modules for all 30 circuits. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. This includes with the DC-DC Panel with MCB (Min. 05 -48V DC) , 230V AC distribution panel and installation, testing and commissioning of the system. Inspection by the Representative of Railway. Note: 80% payment made after supply of material (this amount will be paid as per payment clause of supply of materials as para 16.3 of payment clause of Chapter -4 in Tender Document) and balance 20% payment made after commissioning of the system."
Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner 20 dia 33 mm with three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. RDSO/SPN/TC/45/2013.Rev.2.0 Amendment 2.0 or latest.Inspection by RITES. Note: The HDPE Duct should be pre inserted with 4 mm nylon rope, inside the HDPE Duct.
Supply of 05 Pair PVC Switch Board cable pair twisted conductor of size 0.63 mm dia. Annealed Copper confirming to IRS: TC/24/91 or ITD 1138. Inspection by the Representative of Railway.
Supply of PVC insulated Wire Coilsa) Multi-strand, single core, copperconductor 22 16/0.2 (16 wires, diameter of each wire is 0.20mm)(0.5sq.mm) wire coil as perspecifications IS 694:2010 or latest,IRS: S 76-89 Amd. 3 or latest.Length of coil should be 100m.Colour of coil to be specified byEngineer in charge.(Per Unit=PerCoil)(INSPECTION BY RDSO)
Supply of one quad VF transformer assembly (cylindrical) (2T) for quad cable for derivation joint as per Spec No- TC 76/2000 Amendment 1 with latest amendment. Inspection by the Representative of Railway.
Supply of Track feed resistance 30 Ohms [2,4,8,16 Ohms] Drg, No. SA-20161- 66 /M and Spec IRS:23/88 (with latest amendment) with PBT base. Inspection by the Representative of Railway. Track feed resistance should be supplied from only RDSO approved sources.
Supply of Track feed battery charger input 110VAC, 50 +/-2 Hz with boost and trickle charging for 1 to 4 cells of 80AH, 10A capacity as per spec. No: IRS:S-89/2013 Ver. 1 or latest. Inspection by RDSO.
Supply of Track lead junction box made of glass fibre reinforced plastic Drg. No. SI- 10272, Alt-C, specification No.RDSO/SPN/151/1997. Inspection by the Representative of Railway.
Supply of Choke coil type-B, impendence 120 Ohms and resistance 3 Ohms DC [For feed end and Relay end], specification No. IRS: S-65/83Amnd. 3 or latest. Inspection by RDSO.
Supply of low maintenance lead acid secondary cells of capacity 2 V - 80 AH with nuts, bolts, interconnector, ceramic vent plug, battery float etc. Specification No. IRS: S-88/2004 with latest amendment with connectors, nuts, bolts, vent plugs, etc. Inspection by RDSO.
Supply of Surge Protection Device for 230 V AC input to PC, complete with enclosure and connected wire as per technical specification No:RS-SPD-5.Inspection by the Representative of Railway.
Supply of Surge protection Device for 110V AC input to signals complete with connected wire as per technical specificition No:RS-SPD-7 .Inspection by the Representative of Railway.
Supply of Surge protection Device for 110V DC input to IPS Goomty, complete with connected wire as per technical specificition No:RS-SPD-7.Inspection by the Representative of Railway.
Supply of Surge Protection Device for 24V DC supply complete with connected wire as per technical specification No: TS-SPD-3. Inspection by the Representative of Railway.
Supply of Surge Protection Device for 12V DC supply complete with connected wire as per technical specification No: TS-SPD-3.Inspection by the Representative of Railway.
"Supply of Single Mode OFC Patch Cord (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement. Inspection by the Representative of Railway. Note: Type of Patch cord and length shall be decided by site Railway supervisor as per the site requirement."
Supply of Digital multi meter. Make : Fluke 101 or similar. Inspection by the Representative of Railway
Supply of Magneto Telephone Desk type to Specification No. IRS: TC-36/97 amd 2. or IRS:TC 79/2000 Amdt. 4 as per Railway requirment. Inspection by the Representative of Railway.
Supply of 24 pair C.T.Box with WAGO make or similar Terminal block (Knife type cage 37 clamp technology [Screw-less] with spring loaded contact) having disconnection and reconnection facility, WAGO module is suitable for termination of cable from 0.4mm to 0.9mm dia, PIJF/Quad cable[Indoor type].Inspection by the Representative of Railway
Supply of Fire Extinguisher CO type, Capacity-1 Kg. Inspection by the Representative of Railway.
Supply of 06 DIGIT SINGLE SIDED Digital OFFICE CLOCK WITH GPS RECEIVER AS PER RDSO SPEC NO RDSO /SPN /TC /62 / 2008, REV04 or latest. Standalone Mode , 24hour Format , 230 V AC working power supply. Inspection by the Representative of Railway.
Supply of Unbranded Aluminium Single Sided A shape Platform step ladder, Capacity 150 kilogram.Inspection by the Representative of Railway
Supply of ELECTRICAL INSULATING RUBBER MATS AS PER IS STANDARD IS 41 15652:2006 OR LATEST. SIZE - 3MM (THICKNESS) X 1 MTR (WIDTH) X 2 MTR (LENGTH), MAT TYPE - CLASS C, MAXIMUM USE VOLTAGE - 33 KV AC (RMS) & 240V DC, DIELECTRIC STRENGTH 65 KV AC (RMS), COLOUR: BLACK, ANTISKID DESIGN. Inspection by the Representative of Railway.
Supply of Office Chairs having foam, fixed arms and as per Model: Candid visitor or similar, Make:Wipro/GODREJ/Methodex. Inspection by the Representative of Railway.
Supply of Rectangular CENTRE TABLE with Tempered glass Top of 1000mmX650mm. Inspection by the Representative of Railway.
Supply of electrolytic copper tape of 25 mm X 2 mm or better for connecting class A devise to earth pit. Inspection by Representative of Railway.
Supply of Multiplexer for DAC/UFSBI to optical,STM/IP-MPLS(E1). Standard19" Rack Mountable deviceconsisting of four E1interface, dual optical portswith dual core and Singlecore path 20 Kms drivingdistance. Multidirectionalsupporting upto 5 directionseither with optical or 45 E1.Ethernet ports for cameraconnectivity. RS232 interface for RTUconnectivity. EM cards with8*E&M ports with 2W/4Wsetting. FXO/FXS cardsupport with 10*FXO/FXSports. Total 4 hot swappableslots for field upgradableMulti service Modular cards.Device Management withTelent & NMS. Unit SupportAudio Buzzer AlarmInterface. Potential Freecontact. Dual DC with 18-72VDC range. Accessories -AC-DC adaptor, E1 & E&Mcable. One E&M card and Cable need to supply.Inspection by RITES.
"Supply of active Lightening Arrester of Class A for building protection as per standard NFC 17-102. It shall work on early streamer emission principle and shall be made of stainless steel with a Time period of 60 micro sec. The dimensions of the device shall be 46 590X120mm. provision shall be there to test this device if necessary by an external tester. A non resettable type counter shall be supplied to count the number of lightening occurrences. Inspection by RDSO. Note: This includes supply of GI mast supplied by OEM as per specification of OEM. Note: latest guidelines/TAN No.STS/E/TAN/3006 Ver3 Dt 30.06.2025 of RDSO/Railway Board for earthing, bonding, surge protection & Lightening Protection system for S&T installations shall only be followed."
"Supply of Fuse Auto Changeover System (fuse Alarm System) for monitoring health 47 of various type of fuses with a Railnet connectivity facility along with audio and visual indication as per RDSO specification No.RDSO/SPN/209/2012 rev-2.0 or latest. The system shall be supplied along with all standby fuses placed in the system. In addition to it, spare quantity of 100% fuses of each type shall also be supplied along with the system -For 32 fuses per set. Inspection by the Representative of Railway." Above/
Supply of RED ASPECT main LED signal 110 Volt AC retrofittable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/199/2010 (REV1.1) or latest scope of supply is as mentioned in RDSO specification. Inspection by RDSO.
Supply of YELLOW ASPECT main LED signal 110 Volt AC retrofittable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/199/2010 (REV1.1) or latest scope of supply is as mentioned in RDSO specification. Inspection by RDSO.
Supply of GREEN ASPECT main LED signal 110 Volt AC retrofittable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No. RDSO/SPN/199/2010 (REV1.1) or latest scope of supply is as mentioned in RDSO specification. Inspection by RDSO. Above/
Item Breakup - F-DESIGN AND SUPPLY OF DRAWINGS
For a Three Line Station
For a Four Line Station Total 52840.00 Item- 2 Supply of Original Tracing of SIP after incorporating all the corrections. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 1172.00 Item- 3 Supply of Amonia Print of Approved SIP S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 624.00 Item- 4 Supply of eight sets of Amonia Print of Approved Completion SIP. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 625.00 ECOR HQ-S AND T/ECOR Item- 5 Alteration of existing RCC & submission of Three paper copies for approval S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 3956.00 Item- 6 Supply of Original Tracing of RCC after incorporating all the corrections. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 1147.00 Item- 7 Supply of Amonia Print of Approved RCC. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 390.00 Item- 8 Supply of eight sets of Ammonia Print of Approved Completion RCC. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 625.00 Item- 9 Design of SWRD & submission of Three paper copies for approval S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 25108.00 Item- 10 Supply of Original Tracing of SWRD after incorporating all the corrections. S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 868.00 Item- 11 Supply of Amonia Print of Approved SWRD . S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 1560.00 Item- 12 Supply of eight sets of Ammonia Print of Approved Completion SWRD . S No. Item Description of Item Unit Qty Rate Amount No
For a Three Line Station
For a Four Line Station Total 625.00 Design of Miscellaneous Diagrams consisting of the items as mentioned below & submission of Three paper copies for approval (i) Floor Plan of Relay Room , Battery Room, Power Equipment Item- 21 Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram S No. Item Description of Item Unit Qty Rate Amount No
For a Two line station
For a three-Line Station
For a Four-Line Station Total 9199.00 ECOR HQ-S AND T/ECOR Supply of original tracing of Miscellaneous Diagrams consisting of the items as mentioned below after incorporating all the corrections. (i) Floor Plan of Relay Room , Battery Room, Power Item- 22 Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram S No. Item Description of Item Unit Qty Rate Amount No
For a Two line station
For a three-Line Station
For a Four-Line Station Total 4684.00 Supply of Ammonia print of approved Miscelleneous Diagrams consisting of the items as mentioned Item- 23 below (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram S No. Item Description of Item Unit Qty Rate Amount No
For a three-Line Station
For a Four-Line Station Total 5544.00 Supply of eight sets of Ammonia print of approved completion Miscelleneous Diagrams consisting of the items as mentioned below (i) Floor Plan of Relay Room , Battery Room, Power Equipment Item- 24 Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram S No. Item Description of Item Unit Qty Rate Amount No
For a three-Line Station
For a Four-Line Station Total 5541.00 Item- 29 Design of Cable Distribution Plan & submission of Three paper copies for approval S No. Item Description of Item Unit Qty Rate Amount No
For a three-Line Station
For a Four-Line Station Total 11837.00 Item- 30 Supply of original tracing of Cable Distribution Plan after incorporating all the corrections. S No. Item Description of Item Unit Qty Rate Amount No
For a Two line station
For a three-Line Station
For a Four-Line Station Total 2975.00 Item- 31 Supply of Ammonia Print of Approved Completion Cable Distribution Plan. S No. Item Description of Item Unit Qty Rate Amount No
For a Two line station
For a three-Line Station
For a Four-Line Station Total 448.00 Item- 32 Supply of eight sets of Amonia Print of Approved Completion Cable Distribution Plan. S No. Item Description of Item Unit Qty Rate Amount No
For a Two line station
For a three-Line Station
For a Four-Line Station Total 897.00
Item Breakup - A1-EXECUTION OF OUT DOOR WORKS
[i] 1.2 Meter depth
[ii] 1.0 Meter depth
[iii] 0.8 Meter depth Total 1385701.00 Transportation and fixing of perforated G.I. Pipes on bridges, culverts, drains or in trenches or any other place as per instruction of site Engineer with clamps at 1.5 mts. interval on steel girder bridges or at places advised by site Engineer. This includes supplying of G.I. Pipes, 80/100/150 mm Item- 9 dia. Specn. No. IS:1239/2004, or latest medium gauge with threaded collars (Make -TATA /JINDAL) by tenderer. This also includes 100 mm thick concreting on GI pipes as required and instructed by site Engineer and all other materials required for the work shall be supplied by the tenderer. S No. Item Description of Item Unit Qty Rate Amount No
1. GI pipes of 100 mm Dia Total 5306000.00 Transportation, Charging, installation, wiring of low maintenance Secondary cells as per manufacture's instructions and Railway's directive. This includes supply of distilled water and sulphuric acid by the contractor at his own cost. The un charged batteries with connector shall be supplied by the Railway. Materials including 3/0.29 PVC wires, battery connector , brass bolts and nuts , PVC tapes eyelets, etc and all other materials shall be supplied by the contractor. Note: [1] Before completion of works contractor shall prepare jointly with Railway Engineer at site and Item- 32 submitt battery capacity test report as per approved format of Railway and hand over all relevant records to the Railway. [2] All the cells failing in the discharged capacity test in the Railway premises will be replaced by new ones free of cost. Railway Engineers decision shall be final. . Capacity test register ( binded size no. 10) in prescribed format shall be supplied by the contractor. In case of failure in capacity test tenderer will be responsible for fresh charging/replacement of the batteries. S No. Item Description of Item Unit Qty Rate Amount No
2 Volts/80 AH Total 4272.00
Item Breakup - B3-SUPPY OF EI MATERIALS
1. Supply of Vital Input card. Make: Medha
2. Supply of Vital Output card. Make: Medha
3. Supply of Power supply and communication Numbers card. Make: Medha
4. Supply of Vital Input Output Mother board. Numbers Make: Medha
5. Enclosure with internal wiring and mounting Set arrangement. Make: Medha Total 4438933.10
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .