Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC LOWEST BID QUOTED | |
| 2 | L2₹17.3 L+₹65,309 (3.93%)Rejected-Finance | L2 | Rejected-Finance HIGHEST BID QUOTED | |
| 3 | L3₹18.0 L+₹1.3 L (8.08%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance HIGHEST BID QUOTED | |
| 4 | L4₹18.2 L+₹1.5 L (9.25%)Rejected-Finance | L4 | Rejected-Finance HIGHEST BID QUOTED | |
| 5 | L5₹19.3 L+₹2.7 L (16.0%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance HIGHEST BID QUOTED |
Tender Value
Refer Docs
EMD Value
₹63,000
Closing Date
4 Nov 2020, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIR MAINTENANCE OF CI GI PIPELINE LORRYING LIFTING OF SUBMERSIBLE PUMP REPAIR/MAINTENANCE OF DG SETs PUMPS AND OTHER MISC MAINTENANCE WORK AT AF STATION NARAINA UNDER AGE EM AF RAJOKRI OF GE AF GURGAON
2020_MES_383649_1
GE/GUR-/NIT-48/2020-21
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹63,000
Yes
16 Dec 2020
5 Oct 2020
7 Nov 2020
5 Oct 2020
4 Nov 2020
19 Oct 2020
Amount
Supply & ,installing, testing and commisioning in replecement of AMF panel capacity 250 KVA cubical floor mounted type made out of MS sheet of not less than 3.15 mm thick with both side openable hinged cover for easy accessibility with necessary control circuit fuses aluminum bus bar of suitable size TPN.The panel shall have indicating instruments and switches and provn of incoming and outgoing electric connection.The AMF control panel should be manufatured prefably by the manufaturer of DG set or by the approved manufaturer of LT panels is universal switch gear following accessories.:-
AC voltmeter 0-500 volts flush type - 01 No .Make :- AE/IMP/MECO
Frequency Meter 100 mm square flush type.- 01 No . Make :AE /IMP/MECO
Ammeter 0-200 amps with CTS flush type - 01 No .Make : AE /IMP/MECO
Ammeter .Make : AE/Havells
Battery Charger 24 Volt -01 No
Transformer /Rectifier unit
DC ammeter Make : AE/Havells
Main supply air break contactor 3 pole of suitable rating Make : Siemens/L & T /ABB
Alternator air break contactor 3 pole of suitable rating and providing with a separate over load delay for over load protection .Make : siemens / L & T /ABB
Suitable for Incomming and out going MCCB for suitable rating -02 Nos ( make - havelles, ABB, )
Set of control relays and timer - 01 set
set of push buttons starter /stop /acknowledge /test /main/breaker/close trips - 01 set.
Audion alarm hootere - 01 set
KWH meter flush type - 01 No .Make : Havells/ capital/jaipur.
Note :- Make of DG Set ( Engine - Greaves) ( Alternater -Stamford) before place the order of panel contractor should be site visit for the manufaturer.
Platform of panel:- The platform shall be constructed as per Manufacturer drawing and design.
Supply ,installation in replacement of starter panel outdoor type with dust and vermin proof compartalized design single front construction ,weld rivet,hinges threads shall be apparent from outside ,powder coated panel IP 52 of size 1375 mmx1050 mmx300 mm including copper busbar of capacity 200 Amp three phase 4 wire and approved manufaturer of LT panels is universal switch gear following accessories.
Incomer section: (i) MCCB 3 Pole 100 A,- 01 No.
RYB indication Lamps,220V AC- 01 Set
Current Transformer, 60/5A,C1-1.0 - 01 set of three
Phase Sequence- 01No.
On Delay Timer,
OUTGOING SECTION: (i) suitable for 10 to 20 HP S/D STARTER (1W+1S) -02 Nos
MCB 32 A TP 10KA-03 No
Over Load Relay, 14-23A
Star Delta Timer,0-60 Sec
On/Off/Trip Indication Lamps, 220 V AC - 01 set
start/Stop Push Button,1NO+1NC Make: Vaishno/Teknic
Power Wire, 10 Sqmm Make:KEI/Polycab
Platform of panel:- The platform shall be constructed as per Manufacturer drawing and design.
Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size 80 to 150 mm Bore of any description such as CI/DI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed.
-do- but for size of 15 mm to 50mm dia pipe line.
Attending leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified. Note: bolts,nuts and washers will be paid under relevant items of schedule
Demolition of existing valve pit chamber , M&L for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed.
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge.
150mm dia
100 mm dia
80 mm dia
M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line.
150mm dia
100 mm dia
80 mm dia
S&F CI Specials/fittings including breaking/taking out defective CI specials for spigot and socket end for CI mains upto 150 mm dia.
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 80 mm bore etc complete all as directed by Engr-in-Charge.
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 100 mm bore etc complete all as directed by Engr-in-Charge.
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 150 mm bore etc complete all as directed by Engr-in-Charge.
Supply and fix in replacement cast iron flanged drilled heavy duty Non Retrun slucice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers etc of size 80 mm bore complete all as directed by Engr-in-Charge.
M&L for repairs and maintenance of sliuce/gate valve of any size including minor spares like spindle, nuts, bolts, wahsers and gasket etc complete all as specified and as directed at site.
Taking out of sluice valve /NRV of size 80/100mm/150 mm from existing distribution CI /DI mains all as specified and as directed.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 40mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 25mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 20mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 15 mm dia bore complete all as specified and directed by Engr-in-Charge.
Taking down CI/DI 100/80mm pipe line including connections and CI fittings complete with removal to store all as specified and directed.
Supply and laying CI pipe line with spigot and socket ends and centrifugaly cast class A in any length laid in trenches of size:-
80mm bore
100mm dia
Taking the water sample for semi under ground sump and submitted the sample of water to the Govt lab for testing of water ,Chlorine test and all chemical componants test complete all as specified and as directed
Supply laying, testing GI tubing 80mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 50mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 40mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 25 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 20 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 15mm dia bore medium grade conforming to IS : 1239 of with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Drilling and tapping cast iron water mains for branch connection of the internal dia 15 mm including clamp piece and nuts and bolts and directed.
.Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose of soil including forming bottom surface to required level and slope all as specified and directed.
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm soil all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and doepositing where directed at a level not exceeding 1.5 m above the strarting point.
Taking down of exixting GI tubing 40/50/80/100mm bore any type.
Taking down of exixting GI tubing 25mm bore any type.
Taking down of exixting GI tubing 20mm bore any type.
Taking down of exixting GI tubing 15mm bore any type.
M&L for repairing and testing of pump centrifugal/mono block upto 5 HP to 20 HP of any make and type including welding work, turning, re-metaling of shaft bush bearing, key and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed .
M&L for rewinding of electric motor upto 20 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed .
Disconnecting old starters, Supply and fix in replacement of fully automatic star delta starter suitable for 10 -20 HP pump motor set, AC 440 V 50 Hz with single phase preventor , over current and short circuit protection Built in voltmeter, ammeter complete all as specified.
Development of Tube well be means of air compressor unit and then by over pumping unit until sand free water is obtained and testing of yield for duration as under :-
(a) For air compressor unit minimum 100 PSI, 300 CFM for 1 to 24 hrs all as specified and directed.
Lifting and taking out the submersible pump set and motor of capacity 10 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sump /bore well and lowering back the pump after repairing from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete.
M&L for repairs & Servicing of defective submersible pump of capacity 10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed . Note:- (a) The rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts will be measured and paid separately under respective item of this schedule.
Supply and fix parts of submersible pump set of capacity 10 HP complete all as specified and as directed.
(i) Bearing bush Gun Metal
(ii) Bearing bush SS with rubber
(iii) Oil seal
(iv) Thrust plate/thrust bearing set
(v) Sand Guard
(vi) CI Thrust Casing
(vii) CI stage casing
(viii) GM Bush
(ix) Mild steel key for impeller
(x) SS Studs with nuts
(xi) CI Intermediate section
(xii) SS coupling bush common for pump & motor with key
(xiii) High Tensile steel shaft
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply & fixing in replecement of coloumn pipe made out of GI pipe heavy grade 80 mm nominal bore each 3 meter length including flange duly welded with web complete all as specified and directed.
Cleaning of storage Semi under ground tank capacity of 90,000 ltr
Cleaning of storage under ground tank capacity of 50,000 ltr
Supply & Fix in replecement of Bib taps CP
Supply & Fix in replecement of Stop Cock CP.
Supply & Fix in replecement of Angle Valve CP
Replacement of burnt out transformer and S&F new transformer of 5 KVA voltage stabilizer complete all as specified and as directed.
Supply only Calcium Hypochlorite 65-70 % Granules for treated water
Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified & directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC complete all as specified & directed.
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
Repair to compressor off size of existing makes and capacity for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified & directed.
S&F in replacement of new reciprocating type (hermetically) sealed AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/2.0 Ton capacity complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/2.0 Ton capacity complete all as specified & directed.
S&F in replacement of Condensor coil for 1.5/2.0 ton capacity A/C complete all as specified and directed.
S&F in replacement of Suction/Discharge valve complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and directed.
S&F in replacement of Copper tube cover complete all as specified and directed.
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F compressor in replecement of sealed for Deep Frezeer complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
Repair and maintenance, refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, complete all as specified and directed.
S&F in replcement of compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.
Supply and fix in replcment of canvas hose reel suitable for fire hydrant , 30 mtr long hose confirming to IS: 636 complete with male & female coupling confirming to IS: 903 made out of brass/ bronze and suitable to nozzle of size 63 mm to 20 mm dia as per Bureau of Indian standards complete all as specified
M & L for servicing of room desert cooler of any make size by cleaning, oiling & greasing, checking of defects and rectifying replacement of unserviceable switches, control switch etc including complete electric wiring 3 core fixable cable plug top and testing complete all as specified and directed.
M&L of desert cooler body made out of 18 gauge sheet and GI grills complete including dismantling of exhaust fan tullu pump with accessories from existing rusted desert cooler and fixing at new body complete including wiring connection PVC pipe connection with accessories
M&L for rewinding of fan motor of desert cooler with super enameled copper wire of existing gauge complete all as specified and directed.
M&L for replacement of bushes /bearing of fan motor of desert cooler complete all as specified and directed.
M&L for replacement of tullu pump submersible for desert cooler complete all as specified and directed.
M&L for replacement of fan motor blade suitable of any size of desert cooler complete all as specified and directed.
M&L of cut wood pad set of superior quality for desert cooler complete all as specified and directed.
S&F in repelecment of wastage water tray of any capacity of water cooler complete all as specified and directed.
Supply and fixing Run lead Pig for CI Joint repairs up to 150 mm dia bore at any loaction.
Supply Only Lead wool for CI/GI Joints upto any size
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed .
S&F in replacement of geyser assembly suitable to fix thermostate , heating element as of the existing size including six nos. of clamps with bolts and nuts etc .
S&F in replacement of heating element 2000 watt capacity triangular type complete .
S&F in replacement of heating element 1500 watt capacity triangular type complete .
S&F in replacement of heating element 1500 watt capacity circular type complete
S&F in replacement of thermostate suitable for storage type water heater complete .
Supply and fix stainless steel tank for 25 ltr storage type water heater complete .
Supply and fix Copper tank for 25 ltr storage type water heater complete .
Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 250 KVA,capacity Make : Kirloskar ( including the cost of the following spares all as per manufacturers instructions and directed by Engineer in Charge .
S & F in repair lubrication oil filter
S & F in repair by pass filter
Checking of hydraulic governer
Chacking and toping up of coolant
S & F in repair fuel filter.
S & F in repair air cleaner element .
Cleaning radiator complete set
Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction
All as per item No. Item No. 100 (a) to (h) here before but capacity 125 KVA DG Set complete all as specifeid and directed by Engineer -in-charge.
All as per item No.100 (a) to (h) here in before but for 100 KVA DG set complete all as specified and directed by Engineer -in-charge.
All as per item No.100 (a) to (h) here in before but for 75 KVA DG set complete all as specified and directed by Engineer -in-charge.
All as per item No.100 (a) to (h) here in before but for 50 KVA DG set complete all as specified and directed by Engineer -in-charge. Note Item No 100 to 104: Genset Shall be serviced with the rep of authorised Service centre.
Repair to alternator capacity of 50 KVA DG set including taking out of alternator and send to work shop for repair of alternator including change of divod element and old unserveciable part and refixing of same place for supply of installed complete all as specified and directed.
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage 6 Amp 95 Volt DC suitable for DG set upto 250KVA complete all as specified and directed by Engineer -in-charge.
Disconnected and opening of self starter assemlly 12/24 volt from 50 KVA to 250 KVA DG set taking out unserveceable part of self starter and supply and fixing in rplacement of self suitable size as required on site complete all as specified and directed.
Dismantling of radiator fan engine of following capacity, cleaning and chocked tubes after draining out water, washing with caustic, descaling and brazing for water leakage etc. and refixing the same properly complete all as specified & directed :
a) 125 to 250 KVA
50 to 100 KVA
Supply only the following items of DG Set of various capacity :-
Battery terminal, lug, bolts type suitable for heavy duty battery.
Battery leads for copper conductor multiwired 10 Sqmm.
Hinges for DG set door of any size, any type as required on site.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 24V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge.
S&F V belt for fan pulley (set of 2Nos) for DG set upto 250 KVA DG Set complete all as specified.
S&F V belt for alternator and water pump assembly for DG set upto 250 KVA complete all as specified.
S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 250 KVA, complete all as specified.
S&F Fuel pipe from fuel tank to fuel filter for DG set upto 250 KVA, complete all as specified.
S&F fuel feed pump suitable size as required on site for DG set of capacity upto 250 KVA, complete all as specified and directed.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 250 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of battery voltage relay 12/24 VDC complete all as specified and directed.
Supply and fixing of Fuse (HRC type) for DG sets of capacity up to 250 KVA complete all as specified and directed.
Supply and fixing of 'starting and stoping time relay, 3 phase, 415 volts', for DG sets of capacity upto 250 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing in replecement of Lead acid maintenance free Battry 12 Volts 180AH of existing type & size suitable for DG Sets . Make : EXIDE/AMCO including initial charging.
Supply and fixing in replecement of 100 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, as per existing make complete all as specified and directed.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long all as specified and as directed
Supply and fix in repair GI strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Taking down Air termination, single pointed, copper rod 12mm dia and 300mm long all as specified and as directed .
Taking down GI strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
Taking down test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and as directed.
Supply and Fixing in replecement LED Decorative post-top for 360 degree indirect light IP-65 grade of proterction with High power LED of 40 watt with resistance to impact and corrosion. Glare free and better uniformity.Milky version .complete all as specified and as directed . Cat Part No. LPTO-40-CDL make of CG or its equivalent in Wipro/Phillips Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
Supply and Fixing in replecement circular LED Flood with innovative finless designand excellent indirect light IP-66 grade of proterction with LED 90 Watt with resistance to impact and corrosion. Glare free and better uniformity.Milky version .complete all as specified and as directed . Cat Part No. LFLN-90 cdl make of CG or its equivalent in Wipro/Phillips Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
Supply, laying & testing in replecement of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm
Supply only coolant suitable for generator set diesal engine driven of best quality ISI marked complete all as specified and directed
Supply only electrold water for battey suitable for generator set diesal engine driven of best quality ISI marked complete all as specified and directed
Supply and jointing heat shrinkable straight through joint suitable for HT 11KV XLPE cable of size 120 sqmm 3 core complete all as specified and as directed by Engineer-in-Charge.
M&L for HT indoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 120 Sq mm 3 core complete all as specified and directed.
M&L for HT outdoor termination cold shrinkable suitable for HT cable 11000 volts earthed grade 240 Sq mm 3 core complete all as specified and directed.
Material & Labour for cutting chases and making good for concealing GI pipe of size up to 100 mm dia laid in PCC floor/wall all as per specified and directed.
Supply and fix GI pipe light grade of following sizes for cable protection in trenches/ at PCC poles for loopin/ loopout of cable and cable entry at bldg/block end,all as per specified and directed.
80 mm dia
40 mm dia
Supply & install in repair testing , commissioning of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed.
Supply and spread stone aggregate 40 mm size not exceed 150 mm thick complete all as specified and directed
M&L for cutting,clearing bushes/small plants and grass surrounding the E/M installations and removing the debris to a distance of 50m complete all as specified.
S&F MCCB 200 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider
S&F MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
S & F in replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 70 Sq mm. complete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
ditto but 3.5 core 50 sqmm
ditto but 4 core 25 sqmm
ditto but 4 core 16 sqmm
ditto but 2 core 10 sqmm
ditto but 2 core 6 sqmm
J B Electricals
J.P. Enterprises
JAIPAL AND BROTHERS
Ridhi engineers and builders
PARKASH ENTERPRISES
M/S PRADEEP ENTERPRISES
R. S. Associates
Bluemax Associate
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .