Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.4 LAccepted-AOC | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹37.6 L+₹3.3 L (9.50%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹44.4 L+₹10.0 L (29.1%)Rejected-Finance SHOP NO 6 BENGALI CLUB MIDDLE POINT SRI VIJAYA PURAM 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | 3 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
29 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pankaj Vyas, IDSE, Commander Works Engineer N
Commander Works Engineers No. 2, Brichgunj, Port Blair - 744 103
Provision of AED Electric Supply to ROS at CGDHQ-9, Diglipur
2022_MES_527393_1
80245 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Port Blair
Class D
Category b ii
9 documents required · 9 mandatory
₹500
Garrison Engineer South, Diglipur
₹76,000
Yes
24 Aug 2022
30 May 2022
6 Jul 2022
30 May 2022
29 Jun 2022
13 Jun 2022
30 May 2022 - 6 Jun 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Soft / Loose soil for laying Pipes / Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class HV, Type 1, Flat, of size 300mm x 180mm x 40mm complete all as specified and as directed.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying, laying and testing HT UG Cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [heavy duty] suitable for Earthed System with aluminium conductor of size 3 Core, 95 Sq.mm conforming to IS – 7098 [Part – II] laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Outdoor type, suitable for 11 kV Grade, 3 Core, 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Indoor type, suitable for 11 kV Grade, 3 Core, 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
M & L for Straight Through Joint, Heat Shrinkable type, suitable for 11 kV Grade, 3 Core, 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable Aluminium Conductor and testing after jointing complete all as specified and as directed.
Supply, install, testing & commissioning of Factory Made, Outdoor type, Floor mounted 12 KV, 3 Phase, 3 Wire, 50 Hz, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, 3 Way RMU [Manual Compact Switchgear] Comprising of 02 Nos of 11 kV, 400 Amps, SF6 Insulated Load Break Switches [Outgoing] and 01 Nos, 12 kV, 400 Amps, SF6 Insulated VCB [Incoming] suitable for installations in 12 kV, 3 Phase, 3 Wire, 50 Hz effectively earthed system, including independent manual charged spring mechanism and fully rated earth switch with provision for earth and testing of cable including Air Insulated Cable Boxes with gland plates suitable for bottom entry 3 Core, XLPE, 11 kV, underground cable up to 120 Sq.mm with provision for earthing of cable including set of hooks for lifting during installation complete all as specified and as directed and shall comprise of the following: Make: BHEL / ABB / Areva T & D / Siemens / Andrew Yule / Schneider.
RMU shall be 11 KV, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, Manual / Motorised, Outdoor, 3 Way, Both side Extensible with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations near coastal area and at 40ºC Ambient Temperature without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2mm thick AISI 441 Grade] filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. Ring Main Unit shall comprise of the following:
[A] Vacuum Circuit Breaker [VCB], comprising of the following: [i] 11 KV, 400 Amps, 21 kA / 3 Sec, 3 Pole VCB with Manual / Motorised Spring Assisted Mechanism and Series Trip Coil with 3 Pole Manual Disconnector, 3 Pole Manual Earth Switch, Low energy Trip Coil, Mechanical Emergency Push Button & Counter– 1 Nos [ii] Built-In Earth Switch – 2 Nos [iii] Position Indicator through clear front mimic in line with IEC 62271-103 – 1 Nos [iv] Self Powered Relay with O/C, S/C, E/F Protection – 1 Nos [v] CT Ratio 200-100/1-1A for Incoming, 100-50/1-1A for Outgoing and, Class - 1.0, 2.5VA for Metering and Class 10P10, 2.5 VA for Protection – 1 Set [vi] Live Cable Indicator with indication at the Front and Three Inlets to check the Synchronization of Phases – 1 Nos [vii] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 120 Sq.mm, XLPE Cable – 1 Set [viii] Cable Termination Cover Boots [Push on type] – 1 Set [ix] Fault Passage Indicator [FPI]. [x] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations, 100 Electrical Operations at rated current and 5 Nos Operations at Rated Short Circuit Current.
[B] Load Break Switches, each comprising of the following: [i] 11 kV, 21 kA / 3 Sec, 3 Pole, Manual, Load Break Switch – 1 Nos [ii] Multi Function Meter [MFM] – 1 Nos [iii] Counter – 1 Nos [iv] Fault Passage Indicator [FPI] with Current Sensors [CBCT] for Earth Fault – 1 Nos
Notes for Serial Item No. 11: [a] An operator situated in front, lateral and rear [A-FLR 21kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switchboard during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU. [b] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable. [c] The rate quoted is also deemed to be including the cost of connection of HT Cables up to 3 Core, 120 Sq.mm from 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed. [d] End termination joints shall be measured and paid separately. [e] CONSTRUCTION OF PLINTH / FOUNDATION FOR 11 kV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and nothing shall be paid extra on this account. The foundation shall consists of Two Parallel Block Masonry Walls built in Cement Mortar 1:6 of length 2.10m, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation of pit size 2.10 X 1.20 X 0.60 Metres complete all as per manufacturer’s recommendations, drawings, as specified and as directed.
Incoming: [a] MCCB, 160 Amps, TPN, 36 KA with thermal magnetic release with rotary handle. [b] CBCT [c] Earth Leakage Relay [d] Over Voltage and Under Voltage Relay [e] Phase Indicating LED Lamps. [RYB] [f] Control Fuse Base with 2 Amps HRC Link [g] 5 Stage APFC Relay [h] Timer [i] Aux Contractor [j] Exhaust Fan Outgoing: [a] Capacitor Bank Delta Connected, APP type: 50 KVAR [1 X 25 + 1 X 15 + 1 X 5 + 1 X 3 + 1 X 2 - 05 Nos] [b] MCCB, 160 Amps, TPN, 36 KA [c] Suitable KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts. [d] Suitable KVAR Capacitor Duty Contactor [e] Indicating LED Lamp. [ON/OFF] [f] Push Button. [Start/ Stop] [g] Control Fuse Base with 2 Amps HRC Link. [h] 5 Step APFC Controller - 1 Nos.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and connecting complete all as specified and as directed.
Supplying & Erecting Two Pole Structure consisting of 2 Nos. of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified of type 410 SP–55, 11.00m long complete all as specified and as directed and comprising of the following: [a] Anti-Climbing device, spikes type fabricated out of M.S. bars [round, square and flat] including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete and inclusive of one primer coat, one under coat and one finishing coat of paint. [b] HT Danger Notice Plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in signal red colour on front side as required and fixed with M.S. clamps, bolts and nuts of approved size complete. [c] MS Angle / Channel Bracings, Cross Arms, Supports, Brackets, Clamps etc. including suitable bolts, nuts & washers. [d] Rate quoted by the contractor is deemed to be inclusive of Earth work Excavation, Return filling, removal of surplus soil, Foundation in PCC, 1:4:8, type D2 using 40mm graded stone aggregate and Coping in PCC, 1:3:6, type C1 using 20mm graded stone aggregate etc. complete as per TD of CE [A & N] Zone. [e] Rate quoted by the contractor is deemed to be inclusive of applying three coats of black bituminous paint through out internally and two coats externally on the portion embedded in concrete and applying two coats of aluminium paint over a coat of zinc chrome primer to the exposed surfaces and writing MES No. of Poles [Number size shall be 25mm and lettering shall be 40mm].
S & F Stay Assembly consisting of 16 mm Dia Stay Rod complete with accessories all as shown in Electrical Plate No. 1 including Loop type Insulator, Stay Clamps, excavation and concrete complete all as specified and as directed.
S & F Lightning Arresters, 11 KV, Expulsion type complete with all fittings, 65 kilo Amps discharge capacity, Transmission Class complete all as specified and as directed.
S & F Air Break Switch, Gang Operated, Outdoor type, mechanically operated, mounted on 9 Nos Insulators and Steel Frame, with operating mechanism working from ground level complete with locking arrangements including pad locks with key of Make Godrej / Harrison, for current rating 400 Amps, 11 kV and insulators suitable for 11 kV Grade, 50 Hz including GI Pipe, Medium Grade and all other materials complete all as specified and as directed.
Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 11 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, Oil immersed, CRGO Core type Naturally cooled, Built-up with class "A" insulation, having Primary Voltage [HT] 11 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 11 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, Level-2 with latest amendment including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed and comprising of the following Specification and Fittings: Continuous Rating : 100 KVA No-Load Voltage Ratio : 11 KV / 433 V Tapping on HV [%] : ± 7.5, ± 5, ± 2.5 Phase & Frequency : 3 Phase & 50 Hz Connection : Delta Star Vector Group : DYN 11 Cooling : ONAN Type : Outdoor
Note for Serial Item No. 18: The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted against respective item is deemed to be included for the same: Terminal Arrangement: [a] HV & LV Side: Cable Box [b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side. [c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil. Transformer Oil shall be got tested by AED. [d] Apart from routine tests mentioned in these tender documents and relevant IS, pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.
Fittings: [a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device. [b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug [c] Undercarriage with four plain rollers [d] Oil filling hole cum air release plug [e] Drain Valve cum Sampling Valve [f] Top Filter Valve with Plug [g] Rating Plate with Diagram Plate [h] Lifting lugs for Transformer [j] Lifting lugs for Core [k] Earthing Terminals [l] Thermometer Pockets [m] Silica Gel Breather [n] Explosion Vent [o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB [p] 150mm size Oil Temperature indicator, dial type with alarm and trip contacts [q] 150mm size Winding Temperature indicator, dial type with alarm and trip contacts [r] Buchholz Relay with 2 Shut-Off Valves [s] Marshalling Box with Double Window [t] OCTC
The rate quoted is deemed to be including the cost of PCC / Brick Masonry Foundation / Platform as per IE Rules and of size not less than 1.50 X 1.50 X 1,50m made of PCC Block Masonry built in Cement Mortar 1:6, over PCC Concrete Bed of 10mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, 100mm thick PCC 1:2:4 Coping, Type B1, using 20mmgraded stone aggregate over top of the Platform / Foundation, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including necessary earthwork excavation, return filling, removal surplus soil complete all as per manufacturer’s recommendations, as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed. Note: The rate quoted deemed to be inclusive of Cable Jointing Kits required for terminations.
Supplying and laying GI pipe, 150mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Prasur Electricals & Engineering Co.
Bharat Udyog
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .