Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.1 LAccepted-AOC | ₹30.1 L | L-1 | Accepted-AOC Being lower bidder |
| 2 | L-2₹31.9 LRejected-AOC | ₹31.9 L | L-2 | Rejected-AOC Other than lower bidder |
| 3 | L-3₹34.3 LRejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | ₹34.3 L | L-3 | Rejected-AOC Other than lower bidder |
| 4 | L-4₹36.2 LRejected-AOC BASTI GOVINDPURA SIMBAL MORH MAKHANPUR GOJRAN JAMMU J K 181101 | JAMMU | JAMMU AND KASHMIR | 181101 | ₹36.2 L | L-4 | Rejected-AOC Other than lower bidder |
| 5 | L-5₹36.8 LRejected-AOC VILLAGE DEORA P O PACHAUR DIST SINGRAULI M P 486886 | SINGRAULI | MADHYA PRADESH | 486886 | ₹36.8 L | L-5 | Rejected-AOC Other than lower bidder |
Updated dates
Tender Value
₹48.1 L
EMD Value
₹96,300
Closing Date
22 Dec 2025, 6:00 pmClosed
Sh Tanuj Bagla IDSE EE GE
GE Kaluchak PIN-900673 C/O 56 APO
SPL REP TO BLDG NO P-81 (CLOTHING STORE) AND P-82 (BARBER SHOP) OF ARMD REGT-II AND SPECIAL REPAIR TO BLDG NO T-155 OF OTM ACCN AND T-193 WASHERMAN SHOP AND PROVN OF PARKING SHED FOR TWO WHEELER NEAR CONTRL ROOM AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2025_MES_741310_1
GE/KC-54/2025-26
Open Tender
Civil Works
180 days
Kaluchak
Please ref tender specifications
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹96,300
Yes
25 Feb 2026
24 Nov 2025
24 Dec 2025
24 Nov 2025
22 Dec 2025
8 Dec 2025
Amount
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc incl ceiling complete all as specified and directed.
Demolition of (un reinforced) cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors etc laid, bedded and painted in any mortar complete all as specified and directed
Demolition of cement concretec any description in ground floors and pavings n exc 15 cm thickness below of above ground complete all as specified & directed..
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Demolition of brick work or stone boulder masonary built in cement mortar complete all as specified & directed.
Dismantling AC corrugated, semi corrugated sheets in roof covering complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type including cover fillets, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Taking down roof trusses, coupled rafters or trussed beams Above 4 metres & upto 8 metres complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
Demolition and breaking up drain pipes any type,any dia any location complete all as specified and directed. .
M&L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:4 on brick work or concrete surfaces of walls mixed with water proofing compound ISI marked @ 3% by weight of cement as per manufacture instructions furnished even in smooth without using extra cement complete all as specified & directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick using CM (1:3) on ceiling surfaces complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer paint and over a layer of Birla white wall care putty complete thickness not less than 3 mm on walls complete all as specified and directed all as specified and directed.
M&L for Preparation of newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer paint complete all as specified and directed all as specified and directed.
Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/ chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ ceiling by filling cracks by Berger Bison Putty/ crack fill paste of Berger Paints or equivalent make and make good smoothen surfae by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 sqm mtrs diluted with water in 1:1 ratio as per manufacture's instruction and all coats incl primer to be applied with fuly automatic airless spray machine of paint appliaction with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surrface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed Make : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'CD' on page no. 101 of tender documents as per Sch 'A' Note No 19 Page No 17).
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5 sqm & n.exc. 4 sqm each all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutter from the frames) n exc 1.50 Sqm each all as specified and as directed.
S&F Flush Shutters, 30mm thick, soild core construction with block board core and both faces covered with decorative face veneers with lipping/frame to match on both side, complete all as specified & directed.
S&F Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing of butt hinges of any size/any number, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
S&F Factory made glazed and skeleton shutters 28 to 30mm thick, of second class hard wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified & directed.
S&F Box type steel windows comprising of tubular frame and shutters made out of 1.25mm thick MS steel tube, factory made, with double side shutters wire gauged shutter and glass glazed shutter (wire and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work, including other fittings, hinges, handles tarred hold fasts PCC blocks including provn of opening for cooler if necesary etc complete all as shown on Drawing No CEPZ/TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed.
S& F Box type steel windows/ Steel ventilator with top hung shutter including hinges , steel peg stay complete all as specified and directed.
Taking down shutter of any description, exceeding 1 square metre and not exceeding 2 square metre each, all as specified and directed.
S &F Aluminium handles cast D type, anodised, 150mm size complete all as specified & directed.
S &F Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy , complete all as specified & directed.
S &F Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified & directed.
S &F Mild steel stove enameled helical door spring 150 mm size fixed to pressed steel frame/MS frame/wooden chowkhats including necessary welding work etc (if required) complete all as specified directed.
S&F Stainless Steel Butt hinges, medium weight, 100mm long, complete all as specified & directed.
S &F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with 2nd class soft wooden / flat iron fillet beadings fixed in doors or windows etc complete all as specified and directed
S &F 3 mm thick figured glass, pin head type and glazing with oil putty or wooden beads, in square n exc. 0.5 Sq m each complete all as specified & directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), terrazzo toping and rubbish off the premises complete all as specified & directed.
M&L for 25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crushed stone agg) as in levelling course of floor etc complete all as specified and directed
M&L for Non - skid joint free Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete, all as specified and directed.
M&L for Coloured Joint free glazed Glazed ceramic tiles in vertical surface exceeding 0.18 sqm but not exceeding 0.38 sqm 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick backing coat of cement mortar 1:3 as in dado, skirting, riser of steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete, all as specified and directed.
M&L for Coloured non skid ceramic joint free tiles 300x300x7to 8 mm thick laid in floor over and including 15mm thick screed bed or bedding layer of cement 1:4 set and jointed in neat cement slurry and pointed in white cement to match the colour of tiles all as specified
M&L for machine cut kota stone slab flooring 18 to 20 mm thick over 15mm thick 1:6 cement mortar screed bed or bedding layer laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incliding rubbing and polishing complete all as specified and directed
M&L for machine cut kota stone slab 18 to 20mm thick in riser of steps, skirting, dado etc laid over 10mm thick cement mortar in 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking down eaves gutters and rainwater ,PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete including disconnecting pipes of any dia all as specified and directed .
S & F 110 dia PVC soil waste , and vent pipe in any length with rubber rings joint fixed to wall/laid in floors complete all as specified & directed.
S & F 75 mm dia PVC soil waste , and vent pipe in any length with rubber rings joint fixed to wall/laid in floors complete all as specified & directed.
S & F in repairs 110 mm dia PVC (SWR) bends, of and radius with access door complete all as specified & directed.
All as per item above above but 75mm dia ditto complete all as specified & directed.
M&L Granite (of any type) stone slab 20 mm thick in floors or on Cills , Jambs , steps or cooking platforms etc, set , jointed pointed with grey cement slurry mixed with pigments to match the shade of the slabs including rubbing & polishing laid over and rounding edges to any similar situations and make good including 15 mm thick screed bed in CM 1: 3 complete complete all as specified & directed..
M&L for Factory made precast concrete designer paver tiles of diferent colour& shape of size 300mm x 300mm x 20mm laid and jointed with grey cement slurry with pigment to match colour of tile ,laid over screed bed or bedding layer. compressive strengfth not less than 250 kg /sqcm complete all as specified and directed. Note :Screed bed /bedding laying shall be measured and paid separately
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified & directed.
M&L for 15mm thick screed bed or bedding layer in 1:6 cement mortar complete all as specified & directed.
M & L for PCC 1:2:4 type B-1 using ( 20 mm graded aggregate ) floor, path , hard standing /paths etc complete 100 mm thick finished even and fair with out using extra cement complete all as specified & directed.
M & L for PCC 1:3:6 (M-10) type C1 using ( 20 mm graded aggregate ) as in sub base to flooring 75 mm thick complete all as specified and as directed.
M&L PCC (1:2:4) type B-0 (12.5 mm graded aggregate) filling back of chowkats complete all as specified and directed..
M&L for PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection, path ( 75 mm thick ) finished even and fair complete all as specified & directed.
M&L Providing, cement concrete 1:2:4 type B1, using 20mm graded stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, as specified complete all as specified & directed.
M&L Brickwork with sub class B bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 as in walls etc. complete all as specified & directed.
M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering 2. Highly elastic upto 350% and crack bridging 3. Excellent adhesion on porous and non-porous substrates 4. Tensile strength > 10 N/mm2 with Geo Textile fleece 5. Soler reflective Index (SRI) more then 109-111 ASTM E 1980-11 System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent) Coverage :0.2kg/m2 (with 50 % dilution of water) Reinforcement : Geotextile 40 gsm Second coat : Home sheildroofkoat (or equivalent) Consumption : 0.5 kg/m2 Third coat : HS PU roofkoat (or equivalent) Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsm For accessible roof, tiles with scred/ adhesive may be fixed thereafter. Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'EF' on page no. 105 of tender documents as per Sch 'A' Note No 19 Page No 17).
Complete removal of existing roof treatment of any description viz. tar felt or membrane surface or roof tiles etc. including grubbing up of tree roots and removing all the debris to a distance n.exc 100m and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as directed:- (a) Applying Ist course of 15 mm thick cement screed in CM 1:4 over concrete surface. (b) Applying 2nd course of bituminious primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (c) Applying 3rd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (d) Applying 4th course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, complete all as specified and directed.
M&L for Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges finished even and smooth without using extra cement complete all as specified & directed.
M&L for capilary rise treatment of walls as following :- Base coat: Berger HS Latex plus (or equivalent) Consumption base coat: 0.3 kg/m2 Second and Third coat: Latex sheild 2K (or equivalent) Consumption top coat: 3 kg/m2 System requirements: density: 2.00 kg/ltr Compressive strength: 0.5 N/mm2 Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'AB' on page no. 97 of tender documents as per Sch 'A' Note No 19 Page No 17).
Supply only Integral water proofing compound complete all as specified & directed.
M&L Reinforced cement concrete (nominal mix) 1:2:4 (using 20 mm graded stone aggregates) as in Beams, linlie, cantilevers, bressummers, and the like complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix) 1:2:4 (using 20 mm graded stone aggregates) as in Chajja ,Parapett and the like complete all as specified and as directed .
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc) shelves and similar articles with plain faces and set in cemnet mortar 1:4 complete all as specified & directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, chajjas shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.. complete all as specified & directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complet all as specified and directed
M&L TMT steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L TMT steel bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
All as per item above here in befor but 5 mm dia and over upto and including 10 mm dia in stirrups dia complt allas specified and directed
Taking down cement plaster or decayed concrete of any description including cutting V grooves in 10 -12 mm deep in patches or fully on RCC surface , roof projection, chajjas ,wall , ceiling, etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound or mixed or PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) after preparation WPC pedicrete/ Dr fixit/URP 301 based Latex water proofing with bonding agent in CM 1:2 as bonding coat for old concrete slab/wall surfaces in two coats and first coat mixed in ratio CM 1.1 for repairs including ,necessary form work, where ever required and finally finishing the surface with 15 mm thick cement plaster in CM 1:3 finishing & CM 1:6 as in wall complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed
M&L for Preparation of old steel surfaces over 10 cm width or girth and applying 0ne coats of synthetic enamel paint all as specified and directed complete all as specified & directed.
M&Lfor preparation of old or untreated surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified & directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in roof covering fixed with self tapping screws or L-type or J-type or cranked hook bolts as specified.
S&F pre painted galvalume aluminium zinc coating GI based profile steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in ridge of roof fixed with self tapping screws or L-type or J-type or cranked hook bolts as specified.
M&L for Structural steel /tubular section work as in Roof trusses ( framed), post,trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections or MS tube pipe) including distance pieces, cleats etc Fe-410W(GdeE-250) quality A including shop coat of primer complete all as specified & directed.
M&L for Plates (plain or chequered)channels, square cut or notched (ordinary and counter sunk)forming holes, without any attachment as in gusset plate, base plate etc complete all as specified and directed
S&F Mild steel bolts.purpose made.with hexagonal orsquare head one end and screwedthe other, orscrewed both ends;each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long (dia of necxk exe 12 but n exe 20 mm) compolete all as specified
S&F 600x600 mm grid frame of galvanised iron powder coated section incl supply and fixing 4 mm thick non asbestos designer E board and comprising of under mentioned section etc for grid frame (a) Suspended GI main runner 32x24 mm bulb Tee section fixed with 4mm dia GI bar @ 1200 c/c level shall be adjusted with fly/bionet screws. (b) Placed in position cross Tee 600 mm long and 24x26 mm bulb Tee section @ 605 mm c/c using shape and bionet fixing arrangement to secure main runners. (c) Ceiling GI 26x24 mm size bulb section installed 605 mm long in between cross Tee. (d) GI coated angle 24x24 mm fixed with PVC rawl plugs and GI screws to secure with walls. (e) All the fixing details shown on drg No CEPZ/STD/809/07 dt 03-11-2007 and as per manufacturer instructions as approved by GE complete all as specified & directed.
S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing all as specfied and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and directed.
S&F Mild steel framed works such as grills, framed guard bars, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F MS peg set of six powder coated as approved by GE complete all as specified and directed.
S&F drapery curtain rod of metalic 20mm dia covered with PVC coating including MS bracket, end ball, rounded block (coated with brown/cherry/golden colour) of approved pattern and shade fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and directed.
M&L for Colored glazed ceramic tiles in vertical surfaces 450 x 300 x 7 mm thick set over 10mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or colored cement to match complete all as specified & directed. .
S&F in repairs Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs and S&F 20 mm bore PTMT Ball valve high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe including dismantling of existing water tank of any description complete all as specified & directed.
S&F Gun-metal globe or gate valves with iron handle quarter turn type, screwed both ends for iron pipe or for unions of 20mm dia bore and fixedin repairs, complete all as specified & directed.
Taking down or up steel/GI water tubing and connections including cleaning for refixing or removal from site for 15 mm bore of pipe complete all as specified.
Taking down or up steel/GI water tubing and connections including cleaning for refixing or removal from site for 20 mm bore of pipe complete all as specified & directed.
Supplying & fixing GI water tubing of 15 mm dia, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc and fixed to walls, ceiling, and laid on floors.
Supplying & fixing GI water tubing of 20 mm dia, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc and fixed to walls, ceiling, and laid on floors.
S&F in repairs bib tap 15mm chromium plated fancy type cast cooper alloy with crutch or butter fly handle, screwed down for iron pipe and fixed complete all as specified & directed.
S&F in repairs Vitreous china Orissa pan of pattern, long pan size 580x440mm , with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe complete all as specified & directed.
S&F in repairs PVC flushing cistern low level 10 ltr capacity with inlet ball valve, float valve and handle including brackets and pipe connecting to WC etc including all fittings and all as specified, including dismantling old flushing cistern any type complete all as specified & directed.
S&F PVC connection 45 cm long fitted with PTMT nut and washer on both ends, fixed to 15 mm bore iron pipes complete all as specified & directed.
S&F in repairs Angle cock fancy type chromium plated with capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed complete, all as specified and directed.
M & L Complete removal of the existing treatment and applying two coat of oil bound distemper on walls over 3 mm wall putty complete all as specified and directed.
M & L Complete removal of the existing treatment and applying one coat of oil bound distemper on ceiling complete all as specified and directed.
M&L Excavating in post holes (or for similar work) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and directed
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete in foundation concrete of posts complete all as specified and directed
M & L PCC 1:4:8 type D2(40 mm graded aggregate) as in sub base 75 mm thick finished even and smooth without using extra cement complete all as specified and directed.
M&L hard core of gauge not exc 63 mm , deposited, spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface with broken stone boulders complete all as specified and directed
E/M Portion
Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete all as specified & directed.
Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site complete all as specified & directed.
Taking down existing unserviceable submain wiring any size and making good the disturbed surface complete all as specified & directed.
Material and labour for point wiring for one light controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface complete all as specified & directed.
All as per item no. 112 above but for one fan point controlled by one piano switchalls as specified and as directed.
All as per item no. 112 above but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and directed.
All as per ser item no. 112 hereinbefore but for one 3 pin socket outlet 5 Amp Same board.complete all as specified & directed.
All as per Item no. 112 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
All as per ser item no.112 here in before but for one 3 pin socket outlet 5 Amp independent board complete all as specified and as directed at site complete all as specified & directed.
M & L for submain wiring with two runs of PVC insulated multistranded,FRLSH copper coductor of size 6 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 6 Sq mm strand cable drawn in existing PVC concelled/surface conduite complete all as specified and as directed.
Supply and fix in repairs of Switch piano flush type single pole, one way 5 Amp , complete all as specified and as directed.
Supply and fix in repairs of Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed at site complete all as specified & directed.
Supply and fix in repairs of Ceiling rose surface bakelite three terminals 240 volts complete, complete all as specified & directed.
Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, all as directed by Engineer in charge.
Supply and fix in replacement of Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed.
Supply and fix in repairs Lamp Holder PVC case body of Bakelite with back plate suitable for batten fittings,complete all as specified & directed.
S&F LED Bulb cool white 10 Watt Elegant design direct fit for easy installation complete all as specified & directed.
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623. complete all as specified & directed.
Supply and fixing in replacement sheet metal enclosure double door for MCB DBs SPN 8 way 240 V, complete flush mounted all as specified and as directed.
M&L for MCB single pole 5 to 40 Amps, 240 volts 10K complete all as specified and directed.
Supply and fix in replacement MCB SP-06 to 32 Amp,10KA, 240 volts complete all as specified.
Supply and fix in replacement of MCB SPN 32 Amp, 240 volts 50Hz AC supply, complete all specified.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed.
M & L in repair for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testing complete all as specified & directed.
Taking down Ceiling/Exhaust fan 1200 mm sweep complete cleaning the grease oil etc spray painting with 2 coats of synthetic emamelled paint over a coat of primer including replacement of bearing, capacitor, cotton pin, rubber coal, MS nuts bolts washer, connector prewired from connector from connector to ceiling rose with twin core flexible copper conductor cable 24/0.02 refixing in position connecting testing etc complete all as specified and directed.
Repair and fixing of ceiling fan complete with blades, and accessories obtained vide with provision of new anti suicide fan rod(Suitable size and length and oiling/greasing of fan with provision of flexiable cable twin core all as reqd at site complete all as specified & directed.
Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with suitable size and length of 1.5 sqmm copper conductor with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed.
M & L for switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
M & L for switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed.
M & L for switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
M & L for switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed.
Taking down ceiling fan of any type including discoonnection electrically complete all as specified & directed.
Supply & Fix in replacement of Lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified and directed
Supply and fix in replacement LED Bulb of 10W with Lumen output 1100 and Colour Temp 6500K pendant type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed.
Supply and fixing of Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed.
Supply & Fix in replacement new generation energy saving and Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-litLED luminaire comprising of high brightness LEDs.complete all as specified and directed.
Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduit including 4 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted complete all as specified & directed.
M&L for Isolator SPN 63 Amps, 240 volts complete all as specified and directed.
M/S Shiv Enterprises (BID ID -3498527)
GENESIS INDIA (BID ID -3498599)
J P TECHNO (BID ID -3501446)
ASHISH CONSTRUCTION COMPANY (BID ID -3498703)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_830081.xls
BOQ • 0.40 MB
TENDER54.pdf
Tender Documents • 1.57 MB
Download all tender documents and submit your bid