Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC NO 07 MOOGAMBIKAI AVENUE BEHIND HOINA HOSTEL KANNADAPALAYAM THIRUNINRAVUR CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.7 L+₹2.7 L (10.5%)Rejected-AOC 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹37.6 L+₹11.7 L (44.8%)Rejected-AOC NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L3 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Mariammal Constructions L3 | pmv.enterprises L2 | SAI SRI HARSHA ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00PART -I - COMPREHENSIVE MAINTENANCE TO CERTAIN BLDG OF MD ACCN & OTM ACCN | ||||||
| 2.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. | 10 | Sqm | 45 ₹450 | 36 ₹360 | 29 ₹290 Lowest |
| 3.00 | M&L for Demolition Cement concrete concrete (unreinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. | 10 | Cum | 500 ₹5,000 | 630 ₹6,300 | 199 ₹1,990 Lowest |
| 4.00 | Taking down plastering in cement or cement-lime mortar up to any height (one side only measured in cases where both sides are plastered) etc complete all as specified and directed. | 100 | Sqm | 50 ₹5,000 | 27 ₹2,700 | 25 ₹2,500 Lowest |
| 5.00 | Taking down chowkhats or frames with shutters and (without taking off shutters from frames) n.exc 1.5 sq. m each all as specified and directed. | 10 | Each | 60 ₹600 Lowest | 180 ₹1,800 | 199 ₹1,990 |
| 6.00 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m eachall as specified and directed. | 10 | Each | 50 ₹500 Lowest | 180 ₹1,800 | 299 ₹2,990 |
| 7.00 | Taking down shutters of any description exc 1 Sqm & nexc 2 Sqm each complete all as specified and as directed . | 10 | Each | 50 ₹500 Lowest | 90 ₹900 | 249 ₹2,490 |
| 8.00 | Dismantling plain or corrugated steel sheeting any guage, thickness including Nainital or similar pattern roof covering, all as specified and directed. | 370 | Sqm | 15 ₹5,550 Lowest | 27 ₹9,990 | 19 ₹7,030 |
| 9.00 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, all as specified and directed. | 100 | Sqm | 15 ₹1,500 Lowest | 27 ₹2,700 | 29 ₹2,900 |
| 10.00 | M &L Rendering 10 mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement (Internal surfaces) all as specified and directed. | 100 | Sqm | 280 ₹28,000 | 225 ₹22,500 | 199 ₹19,900 Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
12 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Avadi
Garrison Engineer , Muthapudupet, Air Force Area, Avadi, Chennai-55
COMPREHENSIVE MAINTENANCE TO CERTAIN BLDG OF MD ACCN AND OTM ACCN IN 23 ED ALONGWITH REPAIRS/REPLACEMENT OF LT PBs BUSBAR CHAMBERS , UG CABLES AND CONNECTED WORKS AT TECH AREA IN AF STN UNDER GE AVADI.
2025_MES_737390_1
8330/E8
Open Tender
Electrical and Maintenance Works
Item Rate
250 days
GE Avadi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹78,000
Yes
22 Jan 2026
28 Oct 2025
14 Nov 2025
28 Oct 2025
12 Nov 2025
7 Nov 2025
28 Oct 2025 - 3 Nov 2025
Amount
PART -I - COMPREHENSIVE MAINTENANCE TO CERTAIN BLDG OF MD ACCN & OTM ACCN
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed.
M&L for Demolition Cement concrete concrete (unreinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
Taking down plastering in cement or cement-lime mortar up to any height (one side only measured in cases where both sides are plastered) etc complete all as specified and directed.
Taking down chowkhats or frames with shutters and (without taking off shutters from frames) n.exc 1.5 sq. m each all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m eachall as specified and directed.
Taking down shutters of any description exc 1 Sqm & nexc 2 Sqm each complete all as specified and as directed .
Dismantling plain or corrugated steel sheeting any guage, thickness including Nainital or similar pattern roof covering, all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, all as specified and directed.
M &L Rendering 10 mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement (Internal surfaces) all as specified and directed.
M&L for Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Green Mexican Grass Lawn : Supply, stacking & development of Green Mexican grass lawn by carrying out the following operations all as specified and directed.:- (a) Uprooting vegetation and weeds by digging the area to a depth of 30cm in any type of soil , removing all weeds, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days and then fine dressing for planting new Mexican grass including disposal of all rubbish with all leads and lifts. (b) Supply & stacking of approved good quality earth and well composted, dried, well screened natural farmward manure free of weeds & debris and suitable for horticulture. (c) Developing the area by spreading mixture of approved good earth and farmward manure in required proportion by ratio of 8:1 (08 parts by volume of good quality earth and 01 part by volume of natural farmward manure). It should be ensured that the soil mixture spreading should not be less than 100mm above the existing ground level. Approval of Engineer-in-Charge should be obtained towards spreading of garden soil before laying Mexican grass. (d) Providing & laying Mexican grass turf over developed surface of ground prepared with proper level and ramming with wooden tools (Dhumos) and then rolling the surface with light roller and make the surface smoothen and light watering. A Sample of One Squaremeter of turf shall be submitted to the Engineer-in-Charge for approval of GE before the turf is brought in for use on site. (e) During maintenance period watering the lawn daily by providing required pipes and adjustable sprinklers. (f) Weekly weeding, cleaning and removing dry leaves from the lawn. g) Protection against and control of insects, pests and diseses by spraying fungicides etc once in every month. (h) Weeding & Mowing of lawn by using mechanical lawn mower with hifh capacity collection bags regularly ( not exceeding 15 days) to maintain the grass height not exceeding 50mm from ground level so as not to allow grass to grow wild. Note : The Contractor shall be responsible for replacing any grass which fails to survive as a result of inadequate maintenance operations ; poor workmanship or poor quality or defective grass prior to completion of maintenance period at contractors own expense.
M&L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
M & L providing & injecting chemical emulsion for post construction ATT along external wall below concrete masonry apron using chemical emulsion @ 2.25 liters per linear meter, including drilling holes and plugging the same with CM 1:2 to match with existing flooring complete all as specified and as directed.
M&L for treatment of soil under existing floors of any description using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L for post construction ATT for voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors finishes all as specified & directed
M & L for post construction ATT at point of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same CM 1:2 to match with existing finishes all as specified & directed
M&L for Non-skid ceramic coloured tiles coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar 1:6 (01 cement : 6 coarse sand) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
M&L for Non-skid ceramic coloured tiles coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, dado etc . set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
M &L for 25mm thick PCC 1:2:4 type B-0 (using 12.50 mm stone aggregate) as in levelling course all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection finishing the exposed surfaces fair and even all as specified and directed.
M & L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of plinth protection surfaces complete all as specified and directed.
S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
S&F 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 2nd class hard wood 35 mm thick plain, framed,panelled shutters(any number ofpanels), withpanels of timberflat on both sides (feather edged), orof veneered particleboard mediumdensity, woodparticle board withcommercial faceveneers: suppliedand fitted to chowkats all as specified and directed.
S&F 2nd class hard wood 30mm thick Glazed and skeleton shutters, open rebated and preparedto receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered orrounded. fitted withcut and mitred beadsor securing glass,etc.; sizes of me-mbersof shutters asspecified in SSR PartI, Section 8, clause8.24 (a); supplied and fitted to chowkats all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
M&L for prepartion of new surfaces of wood and wooden based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F SS Butt hinges, medium weight, cold rolled mild steel, and fixed bright polished and fixed, 100mm size fixed with screws all as specified and directed.
S & F Aluminium handles, cast type, anodisedhandle 150 mm cast type anodized all as specified
S & F Aluminium tower bolt 150 mm size complete all as specified and directed.
S&F 300mm long Aluminium sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed with screws all as specified and directed.
S&F for 300mm, Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Cutting holes in brick walls in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required depth of embedded portion of holdfasts measured from the face of the jamb into the wall exc. half brick but not exc.one brick complete all as specified and directed.
Forming jambs, etc to openings including cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work complete in cement mortar 1:4 all as specified and directed.
M&L for holes filling in pre-painted galvalume plain or corrugated steel sheets in hangars with butyl adhesive aluminium waterproof heavy duty leakage repair flashing tapes of size 40 to 60mm length and width and etc all as specified and directed.
M&L for Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and refixing the same after fixing/ positining of the new valley gutters all as specified and directed.
Supply and fixing in repairs Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
Supply and fixing in repairs Pre-painted galvalume aluminium zinc coating GI based ridge with plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed.
Supply and fixing in repairs Pre-painted galvalume aluminium zinc coating GI based valley gutters plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa fixed with self tapping screws complete all as specified and directed.
S&F in repairs 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall all as specified and directed.
S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium frame work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified & directed .
PART -II - REPAIRS/REPLACEMENT OF OLD UNSERVICEABLE LIGHT FITTINGS, DISTRIBUTION BOARDS, MCCBS, SUB-MAIN WIRING, EARTHING AND CONNECTED INTERNAL ELECTRIFICATION WORKS AT ARMY AREA
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for :-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch and regulator
One Exhaust fan/wall mounted fan point controlled by one switch.
One 3 pin 5 amps socket point on same board
One 3 pin 5 amps socket point on independent board
One bell / buzzer point controlled by one bell push
M & L for point wiring with 4 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified and directed.
M&L for Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly complete all as specified and directed for the following:- (Note : Cost of suitable size/module, Modular terminal box, Modular inner,outer cover plate and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring).
one light point controlled by one switch.
One ceiling fan point controlled by one switch and regulator
One Exhaust fan point controlled by one switch.
One bell / buzzer point controlled by one bell push
One switch socket outlet 3 pin 5 Amps on same board along with other switches
One switch socket outlet 3 pin 5 Amps on independent board.
M&L for Point wiring on stone / brick masonry wall complete with two 4 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 4 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly complete all as specified for one 3/5 pin switch socket outlet, 5/15 Amps complete all as specified. (Note : Cost of suitable size/module, Modular terminal box, Modular inner,outer cover plate and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring).
M&L Pointing wiring in Existing conduit with 1.5 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia conduit including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthin for one light/fan/Bell/5 Amp socket all as specified and directed.
M&L Pointing wiring in Existing conduit with 4 Sqmm (nominal area) PVC insulated,(FRLSH) unsheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia conduit including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing for 15Amps socket all as specified and directed.
M&L for replacement of laminated hylam sheet top cover with brass screws, cup wahser suitable for 03/04 modules (switches,sockets etc.,) concealed box and cutting of grooves for switchs,sockets and regulator etc complete all as specified and directed.(Note: 1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators to be measured and paid separately)
All as per Item No. 51.00 here-in- before but 06 to 10 modules complete all as specified and directed.
All as per Item No. 51.00 here-in- before but 18 to 24 modules complete all as specified and directed.
S&F in replacement of concealed metal GI box 10 to 16 modules (accommodated for switches, sockets,regulators etc.,) having high durability,corrosion resistant,earthing terminal with incl all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note:1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators,bell push to be measured and paid separately)
All as per Item No. 52.00 here-in- before but 06/08 modules complete all as specified and directed.
All as per Item No. 52.00 here-in- before but 03/04 modules complete all as specified and directed.
All as per Item No. 52 here-in- before but 01/02 modules complete all as specified and directed.
S&F Switch piano flush type, single pole,5 Amps complete all specified all as specified and directed.
S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all as specified and directed.
S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all as specified and directed.
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all as specified and directed.
S&F electronic fan regulator, flush type phenolic laminated sheet etc complete all as specified and directed.
S&F Bell push, flush type, single pole, 5 Amps, 240 volts complete all as specified and directed.
S &F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F Bell , ding-dong type , AC, 215 volts, 50 HZ complete all as specified and directed.
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F of LED tube light fitting 20/22 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis including taking down old light complete all as specified and directed.
S&F of LED tube light fitting 9/10 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis including taking down old light complete all as specified.
S&F of LED Bulb 12/15 watt, B-22 base suitable for operation on AC, single phase complete including taking down old bulb complete all as specified and directed.
Supply and fix Decorative ECO bulkhead luminaire capacity 10/12W, environmental friendly ultra modern energy saving surface mounted, LED luminaire comprising of high brightness and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ including taking down fitting complete all as specified and directed.
Supply and fix LED building security light 25W, made up of pressure die cast housing with toughed glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 incuding drivers, connecter block etc complete pre wired & connecting up with suitable twin core flexble copper wire and suitable bracket all as per dirtected including taking down old light complete all as specified and directed.
Supply and fix Emergency energy saving LED Bulb 9 watt with back up up to 3 to 4 hrs, B-22 base suitable for operation on AC, single phase including taking down old bulb complete all as specified and directed.
S&F in replacement of Recess mounting LED backlite panel ceiling light environmental friendly aesthetically designed recess mounting luminaire with high brightness LED luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 30/34 Watt LED (2'X2'), CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed.
S&F in replacement of surface mounting LED backlite panel ceiling light environmental friendly aesthetically designed recess mounting luminaire with high brightness LED luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 30/34 Watt LED (2'X2'), CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed.
S&F in replacement of recess/surface mounting LED down lights aesthetically designed luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 12/15 Watt LED ftg, CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed.
Supply and Fixing of Rigid non-metallic PVC conduit for 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc with suitable TV socket box complete all as specified and directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
S&F in replacement of MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F in replacement of MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F in replacement of MCB DB TPN 4 way, distribution DB double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for TPN MCB 63 Amps as incomer and SP MCBs 40 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCB and Outgoing MCB measured separately relevent items.
S&F in replacement of Vertical Load line DB TP&N 4 way, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
S&F in replacement of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 to 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement of 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN and current carrying capacity 40-100 Amp in the DB complete with connection testing and commissioning completeall as specified and directed.
Supply and fix decorative LED wall light fitting made out of polycarbonate suitable for including B-22 base 10 W LED bulb fixed on the wall incl taking down old light complete all as specified and directed
S&F in replacement of MCCBs 63 Amps 415V,16KA, 4 Pole complete all as specified and directed.
S&F in replacement of MCCBs100 Amps 415V,16KA, 4 Pole complete all as specified and directed.
Rectifying faults by attending faults of point/sub main wiring complaints (excluding fittings and fixtures) any rating/ make/ model/ type in position including testing of serviceability of point wiring, finding of fault/ defect and repairing, jointing of wires/ cables properly with required jointing materials and making wiring functional etc., complete all as specified and directed.; all as specified and directed. Note:- (i) The rate quoted is deemed to be inclusive of cost of the required materials like insulation tape etc where required.(ii) Provn of point/sub main wiring, switch, socket accessories will be paid under relavent items. (iii) Contractor or his accredited Engineer/ representative shall collect the list of daily complaints from Complaint Cell.(iv) Contractor shall submit the daily list of all rectified/ non-rectified complaints to the Engineer-in-charge at the end of the day's work on each working day of unit/ AGE's office.
Taking down,servicing & re fixing carefully the Ceiling fan of any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note:- Spares and Rewinding shall be measured and paid for separately.
Taking down, servicing & re fixing carefully the Exhaust fan of any size/ make after disconnecting the electric connections for necessary servicing and replacing the spares, rewinding etc., all as specified and directed. Note : Servicing, Spares and Rewinding shall be measured and paid for separately.
Material and Labour for painting of ceiling fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces complete including writing SM/MES No. in synthetic enamel paint (Black colour) over the same surface where the existing No. was written etc., all as specified and as directed.
Material and Labour for painting of Exhaust fan of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces complete including writing SM/MES No. in synthetic enamel paint (colour as approved) over the same surface where the existing No. was written etc., all as specified and as directed.
Material and Labour for rewinding of fan motors any type/model with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings, including cleaning of rotor, stator and varnishing, heating and providing fresh insulating materials for Ceiling fan of 1200/1400 mm sweep including dismantling and reassembling of fan motor complete all as specified and directed.
All as per above Item no. 90.00 herein before but for Exhaust fan 200 to 300 mm sweep
All as per above Item No. 90.00 herein before but for Exhaust fan 350 to 450 mm sweep
Supply only ball bearing suitable for ceiling fan of size 1200/1400mm sweep all as specified and directed.
Supply only ball bearing suitable for exhaust fan of any size and make all as specified and directed.
Replacement of old/unserviceable capacitor of capacity 2.5 µfd for the fans in position all as specified and directed.
Replacement of old/unserviceable capacitor of capacity 4 µfd for the fans in position all as specified and directed.
Supply and fix PVC canopy/Ceiling fan cap with fixing screws etc suitable for ceiling fan 1200/1400mm sweep etc., complete all as specified and as directed
Supply and fix ceiling fan blade with fixing accesories etc suitable for ceiling fan 1200/1400mm sweep etc., complete all as specified and as directed
Supply and fix exhaust fan blade (metal body) with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete all as specified and as directed
Supply and fix exhaust fan louver (shutter) metal body with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete all as specified and as directed
Supply and fixing in replacement of 200 mm dia, 900 RPM, fresh air fan with plastic louvers, frame incl necessary alteration for fixing of fan in exist window as per site requirement complete all as specified and directed.
Supply and Fix ceiling fans down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, 'U' clamp bolts, nuts, washers, rubber split pin check nut etc., complete all as specified and as directed.
M&L for making hole for fixing of exhaust/ventilation fan size 200 mm to 380 mm with necessary civil work as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed.
M&L for taking down existing un serviceable and refxing with new check nut and split pin including 'U' clamp bolts, nuts, washers, rubber split pin check nut etc.,complete from ceiling fan 1200/1400 mm sweep etc., all as specified and as directed.
Supply and Fix ceiling fan hook made out of 40 x 6 mm MS flat iron and 10 dia MS round bar bend to shape for hanging ceiling fans including taking down existing unserviceable fan hook complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 3.15mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed
pmv.enterprises (BID ID -3477548)
Mariammal Constructions (BID ID -3476859)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
8330NIT.pdf
Tender Documents • 0.36 MB
BOQ_825657.xls
BOQ • 3.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .