| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.0 L+₹1.1 L (2.73%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.9 L+₹2.9 L (7.52%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹47.1 L+₹8.2 L (21.0%)Rejected-AOC 001 HPS MARKET KANPUR GANDHI CHAURAHA RAEBARELI UTTAR PRADESH 229206 | RAE BARELI | UTTAR PRADESH | 229206 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹51.7 L+₹12.8 L (32.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | chowdeshwariconstructionco L5 | M/S Jaiprakash Electrical and Engineering Works L3 | ARUNOTHAYA TRADERS L1 | Shiva Shakthi Electrical Enterprises L2 | SHREE ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00COMMON ITEMS APPLICABLE FOR 'JOB A' & 'JOB B' | ||||||||
| 1.10 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed. | 422 | Cum | 300 ₹1,26,600 | 300 ₹1,26,600 | 250 ₹1,05,500 Lowest | 261 ₹1,10,142 | 369 ₹1,55,718 |
| 2.00 | Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed. | 252 | Cum | 85 ₹21,420 | 80 ₹20,160 | 50 ₹12,600 | 45 ₹11,340 Lowest | 109 ₹27,468 |
| 3.00 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. | 170 | Cum | 300 ₹51,000 | 150 ₹25,500 | 50 ₹8,500 | 18 ₹3,060 Lowest | 99 ₹16,830 |
| 4.00 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed.
Note- Punned thickness of sand 18 cm shall be considered for measurement purpose. | 126 | Cum | 1,500 ₹1,89,000 | 800 ₹1,00,800 | 700 ₹88,200 | 630 ₹79,380 Lowest | 799 ₹1,00,674 |
| 5.00 | Supplying and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. | 10,400 | Each | 36 ₹3,74,400 | 23 ₹2,39,200 | 15 ₹1,56,000 Lowest | 15 ₹1,56,000 Lowest | 32 ₹3,32,800 |
| 6.00 | Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittings and pipes etc complete all as specified and directed. | 2,600 | RM | 5 ₹13,000 | 3 ₹7,800 Lowest | 15 ₹39,000 | 4 ₹10,400 | 39 ₹1,01,400 |
| 7.00 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed. | 350 | RM | 140 ₹49,000 | 130 ₹45,500 | 125 ₹43,750 | 118 ₹41,300 Lowest | 129 ₹45,150 |
| 8.00 | All as per Sl Item no 7.00 here-in-before but of size 10 sqmm 4 core. | 300 | RM | 140 ₹42,000 Lowest | 150 ₹45,000 | 144 ₹43,200 | 144 ₹43,200 | 169 ₹50,700 |
| 9.00 | S&F in replacement MCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed.
SL NO 18 OF JOB A + SL NO 26 OF JOB B | 14 | Each | 3,800 ₹53,200 | 3,500 ₹49,000 | 2,500 ₹35,000 Lowest | 3,600 ₹50,400 | 4,909 ₹68,726 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
12 Jun 2026, 6:00 pmClosed
GE (AF) BANGALORE
Garrison Engineer (Air Force), Military Engineer Services, HQ Trg Command, IAF Campus, Hebbal, Bangalore - 560006
REPAIR/REPLACEMENT OF FEEDER PILLAR BOX, BUSBAR, LT PANEL, EARTHING AND REPAIR/REPLACEMENT TO SECURITY LIGHTS, STREET LIGHTS, GATE LIGHTS, HIGH MAST AND CONTROLLING PANELS AT OMQ AND GOLF AREAS AT HQTC BANGALORE
2026_MES_767244_1
8508/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹96,000
Yes
31 Jul 2026
22 May 2026
15 Jun 2026
22 May 2026
12 Jun 2026
5 Jun 2026
23 May 2026 - 30 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1COMMON ITEMS APPLICABLE FOR 'JOB A' & 'JOB B' | |||||
| 1.1 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed. | 422 | Cum | - | - |
| 2 | Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed. | 252 | Cum | - | - |
| 3 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. | 170 | Cum | - | - |
| 4 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed.
Note- Punned thickness of sand 18 cm shall be considered for measurement purpose. | 126 | Cum | - | - |
| 5 | Supplying and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. | 10,400 | Each | - | - |
| 6 | Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittings and pipes etc complete all as specified and directed. | 2,600 | RM | - | - |
| 7 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed. | 350 | RM | - | - |
| 8 | All as per Sl Item no 7.00 here-in-before but of size 10 sqmm 4 core. | 300 | RM | - | - |
| 9 | S&F in replacement MCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed.
SL NO 18 OF JOB A + SL NO 26 OF JOB B | 14 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tender_8508.pdf
Tender Documents • 0.45 MB
BOQ_859250.xls
BOQ • 0.59 MB
SOC_8508.pdf
Additional Documents • 0.03 MB
Corrigendum_8508.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .