| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.3 L+₹13,140 (1.82%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹8.0 L+₹77,730 (10.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹10.4 L+₹3.2 L (43.8%)Rejected-Finance 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹10.4 L+₹3.2 L (44.8%)Rejected-Finance 14 ILTIFATGANJ AMBEDKAR NAGAR UTTAR PRADESH 224145 UDYAM UP 04 0036158 | AMBEDKAR NAGAR | UTTAR PRADESH | 224145 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-26/2022-23 REPAIR/CLEANING AND REPLACEMENT TO SEWAGE LINES,SEPTIC TANKS,SOAK WELL IN TECH AREA OF JAMMU AND AFS KALUCHAK UNDER GE (AF) JAMMU
2022_MES_553380_1
CA NO GE/AFJ-26/2022-23
Open Tender
Civil Works
Item Rate
330 days
Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹20,000
Yes
23 Dec 2022
21 Sept 2022
24 Oct 2022
21 Sept 2022
22 Oct 2022
8 Oct 2022
Amount
Cleaning manually of blocked WC seat trap, inside house and gully trap it includes remove/refixing of grating and cleaning of WC's trap,kitchen/bath traps any type/pattern (pedestal/squatt pattern) upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n.exc 50m and burying the same in pits complete all as directed by Engr-in-Charge. (Measurement will be carried out each time depend on blockage)
Cleaning of underground SGSW pipes of size 150mm dia by rodding from manhole to manhole or manhole to septic tank/well including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n. exc 50m and burying the same pit and replacing manhole cover in position after cleaning (measurement will be carried out each time depend on blockage) complete all as specified and directed by Engr-In-Charge.
Cleaning and dewatering of septic tanks, soakage well/pits of any depth incl let and outlet chamber and removing sludge (in solid and semi solid), silt, both organic and in-organic nature including any type of waste matterial after plugging of incomimg sewage line and removing waste material / sludge etc to a distance n. exc 100m and burying the same in pit complete all as specified and directed by Engr-In-Charge.
Removing of Sludge, mud from sewage sumpwell, manhole soakpit, soakage well of any depth inlet and outlet chamber (in solid and semi solid), silt, both organic and in-organic nature including any type of waste material/sludge etc to a distance n. exc 100m and burrying the same in pit complete all as specified and directed by Engr-In-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete including removal all debries exceeding 50m but not exceeding 100m all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,drains etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 mitres where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed and as directed by Engineer-in-Charge.
Excavation in trenches in any type of soil n.exc 1.5m wide and exc 1.50m but not exceeding 3.00m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed and as directed by Engineer-in-Charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
Demolition of cement concrete as in bed to drain pipe 150mm/200mm dia including packing under and haunching against the side of pipe or as in manhole benching/bed including removal of demolished material obtain from demolition of sewage line or PCC etc all as specifed and as directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm bore pipes, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in mass concrete, filling & sub base to floors complete, complete all as specified and as directed by Engr-in-Charge.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150/200mm bore pipes.
Reinforced concrete pipes, 200mm bore, class NP2, laid and jointed in cement mortar 1:2 complete with collars complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Salt glazed stoneware (SGSW) grade 'A' drain pipes 200mm bore laid and jointed on concrete bed, complete including testing etc all as specified and shown on drgs (concrete bed shall be measured and paid for separately).
Material and labour Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 for manhole and external pointed flush in same mortar as the work proceeds. Complete all as specified.
All as per srl item No 19.00 here-in-before but except bricks complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed by Engr-in-Charge.
Extra for forming fair finishing drain or channel 30 cm inner girth in cement concrete , using extra cement including forms, moulds etc complete all as specified and directed by Engineer-in-Charge.
15 mm thick rendering on fair faces of brick masonary surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and as directed, complete all as specified and as directed by Engineer-in-charge.
Precast reinforced cement concrete 1:2:4 (Nominal mix) type B-1, using 20mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified and as directed.
TMT mild steel bars, 6 to 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engineer-in-charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engineer-in-charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for 300 x 250 x 7 mm or 450 x 350 x 7 mm thick glazed ceramic tiles coloured as in dado/skirting and vertical surfaces set&jointed in neat cement slurry and pointed in coloured cement over and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles as directed at site complete all as specified and as directed by Engineer-in-charge.
M&L for joint free coloured non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:4 to match Shade, pattern, laying etc of tiles as directed at site complete all as specified and as directed by Engineer-in-charge.
M&L for joint free coloured non skid ceramic tiles 7 to 8 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:4 to match Shade, pattern, laying etc of tiles as directed at site complete all as specified and as directed by Engineer-in-charge.
M/L Cement concrete 1:3:6 type C2 using 40mm graded stone crushed aggregate in plinth protection, 75mm thick, finished even and smooth using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
Dismantling unserviceable /cracked water tanks and removing from site capacity exc 250 litre and n.exc 500 litre complete all as specified and as directed by Engineer-in charge.
Dismantling unserviceable /cracked water tanks and removing from site capacity 1000 litre complete all as specified and as directed by Engineer-in charge.
S & F for in repair 20mm dia ball valve high pressure of PTMT with PVC float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engineer-in charge.
S & F for 500 ltrs capacity rotational moulded polythene water storage tanks (cylindered vertical closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by Engineer-in charge.
S & F for 1000 ltrs capacity rotational moulded polythene water storage tanks (cylindered vertical closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by Engineer-in charge.
Taking up or down steel tubing for 15mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified.
Re fixing only 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified.
Taking up or down steel tubing for 20mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted.
Re fixing only 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floor complete all as specified and dirceted.
Supply and fixing in repairs Angle valve cast copper alloy chromium Plated (CP) 15mm dia screwed down high pressure with crutch or butter fly handles screwed both and iron pipe or for unions and fixed complete all as specified and dirceted.
15mm bore long nose bib tap, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Health faucet including PVC pipe with brass nuts for EWC as approved by Engr-in-charge complete all as specified
S&F in repair CP Jet spary with one meter CP flexible tube 15mm dia for EWC including all connection complete all as specified and dirceted.
S&F in repairs for CP, brass toilet paper holder, fancy type, with brass Chromium plated screws fixed in repairs complete all as specified and directed.
S&F for 10 ltrs capacity (PVC), valve less, syphonic action type, fluhsing cistern, low level, white, with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe for cistern ete complete fixed in repairs all as specified and directed.
Supply and fixing in repairs 110mm bore Cast Iron (SWR) 'P' or 'S' trap, including fixed with solvent cement complete all as specified and directed.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, including brass CP jet nozzle with 900mm long PVC pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs vitreous china urinal flat back 465 x 355 x 265mm size, including grating and connection to flushing pipe and outgoing pipe complete all as specified and directed.
Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes fixed in repairs complete, all as specified and as directed by Engr-in-Charge.
PVC connections 15 mm size with PTMT nuts of length 450 mm, fixed in repairs, complete all as specified and diected by Engr-in-charge.
Taking down CI/PVC/reinforced drain pipes (any size or pattern) incl fittings such as bends, shoes, head, swan neck etc incl cleaning for refixing or removal from site complete all as directed by Engr-In-Charge.
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, laid in trenches for concrete bed or in floors, complete all as specified and as directed by Engr-in- Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 75mm bore, complete all as specified and as directed by Engineer-in-charge.
Removal of soil/silt, shrubs and other waste from the drains and cleaning the surface throughly for free flow of rain water complete all as specified and as directed by Engineer-in-Charge.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the domestic area of Air Force station. 2) The repair work is to be executed in "foul conditions" and contractor's shall take this aspect into account while quoting the unit rates and nothing extra shall be admissible to the contractor.
M/s Sunny Gupta
JK BUILDERS AND DEVELOPERS
Tawi Constructions
M/S R S CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .