| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC PANDABESWAR PASCHIM BURDWAN 713346 | PANDABESWAR | PASCHIM BURDWAN | WEST BENGAL | 713346 | L1 | Accepted-AOC AS PER TCR | |
| 2 | L2₹14.6 L+₹19,097.56 (1.32%)Rejected-Finance BARDHAMAN BARDHAMAN 713378 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713378 | L2 | Rejected-Finance REJECTED AS PER TCR | |
| 3 | L3₹15.0 L+₹58,349.69 (4.05%)Rejected-Finance LAUDOHA LAUDOHA P S FARIDPUR BARDHAMAN BARDHAMAN WEST BENGAL 713385 | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713385 | L3 | Rejected-Finance REJECTED AS PER TCR |
Tender Value
₹14.4 L
EMD Value
₹18,100
Closing Date
14 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER, JHANJRA AREA
OFFICE OF THE GENERAL MANAGER, JHANJRA AREA, PO-LAUDOHA, BO, DIST. - PASCHIM BARDHAMAN, PIN-713385
Trans, install, fabri, trial run extension of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor along -11D from 76L to 82L for development of trunk heading of sector-F in R-VIIA after dismantling of -13D belt at 3n4 Incline, J.P.C.
2022_ECL_266342_1
ECL/GM/JNR/EnM/e-Tender/ 22-23/A2/65,Dt.30.12.2022
Open Tender
Miscellaneous Works
Item Rate
45 days
JHANJRA UNDERGROUND
please refer tender document
4 documents required · 4 mandatory
₹18,100
9 Mar 2023
3 Jan 2023
16 Jan 2023
3 Jan 2023
14 Jan 2023
4 Jan 2023
3 Jan 2023 - 9 Jan 2023
Amount
Dismantling of complete -13D belt conveyor (1000mm wide, 1X90kW, 550V, 140mtr. long) from 72L/-13D to 75L/-13D at R-VIIA seam.
Dismantling of the 1000mm width, 1x90kW, 550V, single Drive Head unit Complete with Drive Drum, Driven Drum, Gear Box, Motor, Couplings, Bearing Blocks, baseplate, fencing etc. of -13D belt conveyor from 73L/-13D (R-VIIA).
Dismantling of the complete belt discharge unit with strike plate & chute plate of 1000mm width -13D belt conveyor from 72L/-13D (R-VIIA).
Dismantling of the complete belt tail end unit with fencing & dust collector of 1000mm width -13D belt conveyor from 75L/-13D (R-VIIA).
Dismantling of 140mtr. 1000mm width -13D belt conveyor structure complete with stringer, foot stool, top Bracket, top roller, bottom roller, decking plate, scrapper etc from 72L/-13D to 75L/-13D in R-VIIA seam.
Unlapping & pulling out of 280mtr. 1000mm width PVC belting of -13D belt conveyor from 72L/-13D to 75L/-13D in R-VIIA seam; Dismantling of pull cords with cable, communication devices with cable,signaling wire, bobbin insulators etc for a length of 140mtr. belt conveyor of -13D belt from 72L/-13D to 75L/-13D in R-VIIA seam
Transportation & installation of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor for a length of 60mtr from 76L/-11D to 78L/-11D in R-VIIA seam at 3&4 Incline, J.P.Colly
Transportation of the 1000mm width, 1x90kW, 550V Drive Head complete including gear box, motor(90kW/550V), base frame, couplings, bearing blocks, fencing etc from 73L/-13D(R-VIIA) and installation at 77L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plates, scrappers etc from 72L/-13D(R-VIIA) and installation at 76L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Loop Take Up Unit complete with motorized winch from 14XD/62L(R-VIIA) and installation at (76L-77L)/-11D (R-VIIA) with necessary fabrication job.
Transportation of Tail End Unit complete with fencing from 75L/-13D (R-VIIA) and installation at 78L/-11D (R-VIIA) with necessary fabrication job.
Transportation of 60mtr. 1000mm belt conveyor structure complete with stringer, foot stool, top bracket, top & bottom roller etc. from -13Dip, R-VIIA seam to -11D(3rd) belt installation site and installation from 76L/-11D to 77L/-11D in R-VIIA seam.
Loading, transportation and unloading of one breaker(550V/200A), starter(550V/90kW), LS unit from 73L/-13D(R-VIIA) to 76L/-11D(R-VIIA) manually. (Distance- approx. 140mtr.)
Transportation of 150mtr 3.3kV grade 70 sq.mm. PVCDWA cable from -13Dip, R-VIIA to 72L/-11D(R-VIIA) manually. Then laying-hanging this cable from 72L/-11D(R-VIIA) to 76L/-11D(R-VIIA).
Transportation of 130mtr. 1000mm width PVC belting from -13Dip, R-VIIA seam to -11D(3rd) belt installation site manually. (Distance- approx. 140mtr.)
Laying, lapping, jointing & tensioning of this 130mtr. 1000mm width PVC belting in proposed -11D(3rd) belt.
Transportation of 60 mtr belt sequence cable from -13Dip, R-VIIA seam to- 11D(3rd) belt installation site manually, then laying-placing them from 74L/-11D to 76L/-11D in R-VIIA seam.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) from-13Dip, R-VIIA seam to -11D(3rd) belt installation site manually for 60mtr. belt and laying-placing them from 76L/-11D to 78L/-11D in R-VIIA seam.
Testing, trial run, alignment & commissioning of this belt conveyor from 76L/-11D to 78L/-11D in R-VIIA seam.
Five times extension of the proposed -11D(3rd) belt conveyor from 78L/-11D to 82L/-11D for a length of 180 mtr. in R-VIIA seam of 3&4 Incline Unit, JPC.
Five times dismantling of tail end unit complete for five times belt extension of proposed -11D(3rd) belt.
Five times transportation and installation of tail end unit complete for five times belt extension from 78L/-11D (R-VIIA) to 82L/-11D (R-VIIA).
Transportation of 1000mm belt structures (i.e. foot stools, channels, brackets, top and bottom rollers etc.) for a length of 180mtr. from surface to belt extension site by haulages and installation them from 78L/-11D to 82L/-11D in R-VIIA seam during five times belt extension. *Each time belt extension will be for a length of 36 mtr.
Transportation of 360mtr. 1000mm PVC belting from surface through haulages to 16XD/71(R-VIIA).
250 mtrs manual transportation of 360mtr. 1000mm PVC belting from 16XD/71 (R-VIIA) to proposed -11D(3rd) belt extension site.
Laying, Lapping, Jointing & Tensioning of this 360mtr. 1000mm belting from 78L/-11D to 82L/-11D in R-VIIA seam during five times belt extension and trial run.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) for 180 mtr. belt from surface to -11D (3rd) belt extension site.
Laying & fitting pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) from 75L/-11D to 82L/-11D in R-VIIA seam during five times belt extension.
Civil foundation works for installation of 1X90kW, 550V, 1000mm wide belt conveyer drive head, discharge unit, loop take-up unit and platform for ACB, Starter for -11D(3rd) belt conveyor of 3&4 incline, JPC.
Recess cutting in stone.
Cleaning of debris.
Sand filling.
Brickwork with fly ash bricks in foundation & plinth in cement mortar 1:6
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement :2 coarse sand (zone- III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources.
12mm cement plaster of mix1:6
Loading material into tub and unloading at site.
Roof heightening by drilling blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for installation of proposed-11D(3rd) belt conveyor in R-VIIA seam of 3&4 incline under JPC.
Roof heightening by drilling, blasting in stone including dressing, cleaning with cost of drill rod and drill bit.( Excluding cost of explosive & detonator).
Roof bolting including carrying of materials from surface to u/g side, drilling, grouting & cost of drill rod and drill bit.
Supply of Materials
Supply of DA cylinder
Supply of oxygen cylinder
Supply of MS NUT BOLT 5/8”X2”
Supply of HT NUT BOLT of M20X75mm
Supply of HT NUT BOLT of M20X65mm
Total impact of GST for the purpose of CTC
BABLU SINHA
RINA ENTERPRISE
stage.html
html • 0.04 MB
techsummary_275517.pdf
PDF • 2.81 MB
finsummary_275517.pdf
PDF • 2.81 MB
WO65.pdf
PDF • 5.20 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .