Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | ₹14.7 L Quoted ₹15.0 L | L1 | Accepted-AOC ACCEPTANCE |
| 2 | L2₹17.5 L+₹2.5 L (16.9%)Rejected-Finance 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹17.5 L+₹2.5 L (16.9%) | L2 | Rejected-Finance L2 |
| 3 | L3₹17.9 L+₹2.9 L (19.4%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | ₹17.9 L+₹2.9 L (19.4%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical N 11 H PL NO 01 CIDCO NAVNATH NAGAR NAVNATH NAGAR AURANGABAD MAHARASHTRA 431003 INDIA | AURANGABAD | MAHARASHTRA | 431003 | - | - | Rejected-Technical DD EMD AND ALL OTHER DOCS AS PER ENLISTMENT CRITERIA OF E CLASS CONTRACTOR NOT SUBMITTED |
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
5 May 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE OF DG SETS AMF PANEL FIRE ALARM PANEL AND CONNECTED WORKS AT VARUNAPURI NOFRA UWR OF AGE EM II UNDER GE (NW) VASCO
2025_MES_703343_1
85930/E8
Open Tender
Electrical and Maintenance Works
Item Rate
500 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹40,000
Yes
28 Jun 2025
2 Apr 2025
7 May 2025
2 Apr 2025
5 May 2025
16 Apr 2025
Amount
Servicing, cleaning and testing of DG sets of make Kirloskar/Cumins /Greaves /Mahindra /Sudhir by technician /mechanic visiting the installations of DG sets of following capacities at various locations. Checking and testing complete DG sets on load (Including engine, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/ replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements, all as directed, including following jobs and the works as directed :-
(i) Checking and cleaning of diesel filters & oil filters and replacing of defective filters. (ii) Checking of engine oil level and topping up , if any. (iii) Checking, cleaning and servicing including oiling & greasing of moving parts of engine and making list of repairs / replacements required, if any. (iv) Checking, cleaning, watering & general servicing of battery, battery charging system including tightening of nuts, bolts, lugs . (v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any.
(vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop.(vii) Checking, cleaning and general servicing of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/replacements required, if any (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors, meters, etc. and making list of repairs / replacements required, if any.
(x) Tightening / replacement of nut/water /oil leakage from any point and rectify if can be rectified by minor repairs / replacements. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements requirted, if any. (xiii) Checking, cleaning & general servicing of exhaust / silenecer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. else make a list of repairs / replacements required, if any.
(xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. Checking AMF panels , connections, contactors , relays cable connections etc for proper function (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any.
(xvii) (a). Checking output of alternator and adjusting the same to specified values, in case of brush type (b) cleaning & servicing of the alternator, minor repairs & replacements (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers . (xix) Checking, cleaning & servicing of air filter elements Note - Rates quoted by the tenderer are deemed to include the cost of S&F in replacement of minors parts like nuts, bolts, washers, gaskets, wirings ,lugs, etc., supply and applying oil & greasing and minor repairs to DG set. Other spares like Engine oil, filters etc shall be paid under seprate items
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
M&L for preparing old painted surface of DG sets of capacity as under (complete including engine, alternator, body & chases) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and as directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
Supply & fix in repairs lead Acid batterys for DG set of following capacity:-(Maintenance free battery with 2 years warrenty) with battery terminal made of brass :-
88-90 AH,12 Volt complete all as specified and directed.
150 AH,12 Volt complete all as specified and directed.
180 AH,12 Volt complete all as specified and directed.
M&L for servicing and caliberation of FIP (Fuel injection pump) & nozzles including replacement of minor parts like nuts,bolts,washers etcof DG sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
M & L for taking out radiator and connecting parts of DG set 20 KVA to 82.5KVA for repair,welding,brazing,leak testing, descaling & refixing to DG set to its original position and testing on load for DG Sets of complete all as specified and directed.
All as per item 5.00 above but radiator and connecting parts of DG set 100 KVA to 320 KVA complete all as specified and directed.
M&L for repairing to alternator of battery charging complete overhauling & servicing of the alternator incl repair/replacement of unserviceable parts,assembling for DG sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S & F in replacement solonid Switch for 100 to 200 KVA DG set and testing complete for proper functioning for DG sets of complete all as specified and directed.
All as per item 8.00 above but Solonid Switch & Relay card for 20 to 82.5 KVA capacity DG set complete and testing all as directed.
Supply and fix in replacement Relay for AMF panel for capacity 20 KVA to 320 KVA DG sets of complete all as specified and directed.
S & F in repairs power contactor 4 pole 415 V, AC 1 Current rating of 32 Amps suitable for AMF panel complete all as specified and as directed.
S & F in repairs power contactor 4 pole 415 V, AC 1 Current rating of 130 Amps suitable for AMF panel complete all as specified and as directed.
M&L for taking out , transporting to workshop, Repairing & Servicing of self starter of DG set ranging from 20 KVA to 320 KVA including replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc., reassembling and testing complete as directed.
Descaling of water jacket of engine by using chemical descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leaks and recirculating with clear water complete all as directed for following DG sets for DG sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S & F in replacement "V" belt for Radiator fan of any size suitable to DG set of following capacities of Make : Fanner ,
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
Supply and filling up of Engine Oil (20 W 40) for toping up oil tank of DG sets complete all as specified and directed.
Supply & Fil for toping up of pre mix Coolant for DG Set
M & L for cleaning of Diesel Tank of DG Set including painting with one coat of oil paint & painting as "Tank Cleaned on Date………..all as directed .
S & F in repairs Anti vibration pad suitable for 25 to100 KVA DG set all as directed .
S&F in replacement of Diesel filtter suitable for following capacity of DG Sets for DG sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S&F in replacement of Oil filtter suitable for following capacity of DG Sets for DG sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S&F in replacement of Ignition Switch of DG Sets for DG sets of complete all as specified and directed.
S&F in replacement of Hose Pipe Set suitable for any capacity of DG Sets of complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S&F in replacement of AVR suitable for following capacity of DG Sets for DG sets complete all as specified and directed.
DG set 200 KVA at NOFRA & NUWR Pump House- 02 Nos
DG set 125 KVA at NOFRA Pump House & P-404 -02 Nos
DG set 100 KVA at Mangoor & Varunapuri Pump House -02 Nos
DG set 82.50 KVA at NUWR & BMF pump house- 02 Nos
DG set 320 KVA at Keerti Enclave MAP PH II Pump house & VAT site -02 Nos
DG set 25 KVA at Sewage Pump House & DCRA Pump House -02 Nos
DG set 20 KVA at New leading Pump house -01 Nos
S&F in replacement Self Starter 20 to 82.5 KVA DG Set 12 Volt.
S&F in replacement Self Starter 100KVA to 320 KVA DG Set 24 Volt.
S&F in replacement control wiring existing specifications and size of DG Set 20KVA to 82.5 KVA for DG sets of complete all as specified and directed.
All as per item 27 above but for DG Set 100 to 320 KVA of complete all as specified and directed.
S & F in replacement battery charger of capacity 10 Amps for 1x12 Volt Battery complete all as specified and directed
All as peritem 29 above but battery charger of 10 Amps for 2x12 Volt Battery complete all as specified and directed
S & F in repairs Disel Pipe from Filter to Pump Complete for 20 to 82.5 KVA all as directed.
S & F in repairs Disel Pipe from Filter to Tank Complete for 100 to 320 KVA all as directed
S & F in replacement Radiator including connecting parts , hose pipes , fittings/fixtures etc up to 20 KVA to 82.5 KVA DG Set for DG sets of complete all as specified and directed.
All as per item 33.00 above but Radiator of upto capacity 82.5 KVA to 320 KVA DG sets complete and testing all as directed.
S & F in replacement DG Set power controller for capacity up to 20 KVA to 82.5KVA DG Set for DG sets of complete all as specified and directed.
All as per item 35 above but power controller for 82.5 to 125 KVA DG Set .
All as per item 35 above but power controller for 200 to 3200 KVA DG Set .
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having following capacities :-
200 Amps 35 KA 4 Pole complete all as specified and directed.
250 Amps 35 KA 4 Pole complete all as specified and directed.
400 Amps 36 KA 4 Pole complete all as specified and directed.
Repairing to alternator complete overhauling & servicing of the alternator incl repair/replacement of unserviceable parts rewinding with existing size copper wire complete ,Assembling for DG sets of complete all as specified and directed. complete and testing all as directed for following capacity DG sets :-.
DG set of capacity 20 KVA to 82.5 KVA complete all as specified and directed.
DG set of capacity 100 to 320 KVA complete all as specified and directed.
Supply and install, testing ON Load type changeover switch four pole ,AC 415 volts 50 HZ of following capacities with enclosure , side handle operated conforming to IS:13947 including fixing on wall / panel complete all as specified and directed.
Changeover switch of capacity 400 Amps 4 pole complete all as specified and directed.
Changeover switch of capacity 200 Amps 4 pole complete all as specified and directed.
Changeover switch of capacity 63 to 100 Amps 4 pole complete all as specified and directed.
Supply, install, testing & commissioning intelligent addressable fire alarm control panel with one Loop complying with EN 54 standard & LPCB approved and battery back up with the specifications as appended below:- a)Power- AC 230V, 50Hz, 0.5 A b) 235 Devices including detectors, minimum 2 loop, c) Relay- Fire Alarm/ F.P.E/ Fault/ Sounder d) configurable for PC Port- RS-232 interface & communication card e) LCD Display and with battery backup of 24 Hours in non alaram condition and 15 Minutes in alarm condition (Battery type 2 X 12V 14AH, sealed type complete all as specified and directed.
Supply, install, testing & commissioning electronically addressable intelligent combination of heat and photo electric smoke detector with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a)Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current) b) Class A2R , c) Indicator- Red Flashes in normal and illuminates in alarm, d) Ingress Protection IP-22 & Material-ABS
Supply and fixing Remote response indicator annunciating device complete all as specified and directed .
Supply, install, testing & commissioning electronically addressable intelligent Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:- a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hz b) Range-1000 m c) visual indication complete all as specified and as directed.
Supply and fix of Amplifiers suitable 30 Watts, 230 VAC 50 Hz complete all as specified and directed.
Supply and fix Loud speaker 15 watt 230V,50Hz, of sturdy design weather proof type with Re-entrant horn type loud speaker for operating under rough condition complete all asspecified and directed.
SHIVANI ENTERPRISES (BID ID -3290885)
U k Enterprises (BID ID -3290151)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .