Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.7 L+₹2.7 L (8.73%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.2 L+₹4.2 L (13.5%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Not Lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN - 95 OF 2023-2024 SPECIAL REPAIR TO ROOF AND OTHER ALLIED SERVICES TO B/R AND E/M AT BLDG NO 26-27 OF ADV HQ SWAC AND PROVN OF VARIOUS SERVICES RELATED TO B/R AND E/M AT BLDG NO 24 OF ADV HQ SWAC UNDER GE(NORTH) PUNE
2024_MES_640591_1
GE (N) P/TOKEN - 95 OF 2023-2024
Open Tender
Civil Works
Item Rate
240 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹89,000
Yes
4 Apr 2024
3 Feb 2024
7 Mar 2024
3 Feb 2024
29 Feb 2024
17 Feb 2024
5 Feb 2024 - 9 Feb 2024
Amount
Dismantling single layer Mangalore pattern tiles or similar tiles in roofing including necessary fillets and similar items and taking out from the site without disturbing existing false ceiling complete all as directed.
M&L for roof tiles Mangalore pattern interlocking at side joints, laid dry class A-A complete all as specified and as directed.
Fixing only roof tiles Mangalore pattern interlocking at side joints, laid dry complete all as specified and as directed. (Note : Serviceable tiles obtained from dismantled shall be re-used.)
M&L for ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:6) etc complete all as specified and as directed.
Fixing only for ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:6) etc complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting , any gauge, thickness including Nainital or similar pattern roof coverings complete all as directed.
S&F for 0.63mm thick Plain Galvanised mild steel sheeting for mangalore roof, ridges, valley gutters drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 , both sides inclusive complete all as specified and directed.
S&F for 0.63mm thick Corrugated Galvanised mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in mangalore roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed.
Fixing only 0.63mm thick plain/corrugated galvanised mild steel sheeting as in ridge with grade of zinc coating120 gms/ sqm, both sides inclusive complete all as specified and as directed. (Note : Serviceable tiles obtained from dismantled shall be re-used.)
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws with two corrugation side lap complete all as specified and as directed.
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling battens of tiles of any size and description spaced exc. 15cm including tilting fillets complete all as directed.
All as per serial item No.12 here-in-before but except battens complete all as specified and as directed. (Note : Serviceable materials obtained from dismantled shall be re-used.)
S&F for 2nd class hardwood clean sawn tile battens, cross sectional area exc 5 and n.exc 15 Sqcm spaced at 30 cm centres to centres fixed with nails complete all as specified and as directed. (NOTE : Measurements shall be taken overall including both battens and spaces. Deductions shall be made only for openings exceeding 0.4 sqm each).
Dismantling timber in scantling, fillets, rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work in any position complete all as directed.
M&L for 2nd class hard wood, clean sawn, in scantling timber unframed work complete all as specified and as directed.
All as per serial item No.16 here-in-before but except timber complete all as specified and as directed. (Note : Serviceable materials obtained from dismantled shall be re-used.)
Dismantling timber scantling in fillets, rails, rafter, purlins etc, under 40 Sqcm in section, unframed work complete all as directed.
M&L for 2nd class hard wood plain fillets, rectangular in section, clean sawn, bull nosed splayed chamfered or rounded on one edge or face, secured with nails, sectional area exc.13 Sq.cm and not exc. 25 Sq.cm complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 as in batterns for roofs, post, purlin, rafter etc complete all as specified and as directed.
S&F for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe 410-W(Gde-E-250) quality -B complete all as specified and as directed.
S&F for rolled mild steel frame work as in grills, doors or gates of angle or other sectioin with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings also fastenings and fixing etc. conforming Fe 290-W(Gde-E-165) quality -B complete all as specified and as directed.
M&L for mild steel Fe 410-W(Gde-E-250) quality-B in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed.
M&L 2 coats of synthetic enamel paint over a coat of red oxide primer on newly steel surface including preparation complete all as specified and directed.
Dismantling of eaves/ boarding any description and in any position fixed with nails complete all as directed.
M&L for Eaves/ weather boarding with 10mm thick fibre cement board (non asbestos) and fixed with self drilling and tapping screws of CSK head and joints finished with jointing compound and fiber tape as per manufacturer's recommendation complete of approved arch pattern any size and shape including two coat of synthetic enamal paint over one coat of suitable primer complete all as specified and as directed. Make: V-Board (Visaka Industries Ltd)/ Everest/ Charminar/ Ramco
M&L for PCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping on top of wall, bed blocks, lintel band upto 1.5 m. span and the like including weathering, slightly rounded or chamfered angles and throating including use of necessary form work all as specified and as directed.
M&L for preparation of new untreated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old wooden surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling of wall/ceiling board of any description and any thickness including cover fillets etc complete all as directed.
M&L position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600x600mm, with GI frame work main runner 38 x 24 x 3600mm, cross 'T' 25 x 24 x 60mm/25 x 24 x 1200mm and wall angle 24 x 24 x 2540mm (thickness of the material of 0.30mm ), using 8-9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dia GI bar hanger from the purlins of the roof with butterfly clips all as specifed and directed by Engineer- in -charge. Make:-Gyproc/Armstrong.
M&L for preparation of wood surfaces and wood based material new or old of any description and girth not other wise described and treated with one coat of creosote oil complete all as specified and as directed.
M & L for rainwater gutter system of SWR pipe 180 mm nominal dia. half round type alongwith all accessories/ fittings complete all as specified and directed. Make : Prince Model HPR18R or equivalent of Infra, Supreme, Kisan, Astron Plastic, Amogh Plast, Finolex
M & L for rainwater gutter system of SWR pipe 250 mm nominal dia. half round type alongwith all accessories/ fittings complete all as specified and directed. Make : Prince Model HPR18R or equivalent of Infra, Supreme, Kisan, Astron Plastic, Amogh Plast, Finolex
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc in any height of Bldg complete all as directed.
M&L for glazed ceramic coloured tiles of size 450x300x7-8mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick backing coat in CM1:4 complete, all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed
M&L coloured vitrified double charged tiles 8-10mm thick (square/rectangular) area of each tile exc 0.18sqm but not exc 0.36sqm as in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 20mm thick screed bed or bedding layer in CM 1:6 and demolition of existing tiles of any description complete all as specified.
-Ditto- all as per item No 39 here in before, but skirting/dado on vertical surfaces incl 10mm thick backing of cement plaster in CM 1:4 complete all as directed.
Taking down chowkats or frames not exc. 1.5 sq. m each with shutters of any description (without taking off shutters from the frames) complete all as specified and directed
All as per srl item No.41 above but exc. 1.5 sq.m but n exc 4 sqm each complete all as specified and directed
S&F in aluminium powder coated three track sliding window with two glazed shutters with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make complete all as specified and directed. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
S&F fully glazed single/double leaf openable door, using aluminum powder coated sections of doors incl pivots with 5.5mm thick tinted glass in panels fixed with aluminum glazing clips section No 19381 and 19352 and PVC rubber beading all around including with 1" interlock and handle, two lever door lock, sliding wheel etc sections as given below and all as specified and as directed. Top-19528, Middle - 19575, Bottom-19530, Vertical-19526,1" interlock(20339), 1" Handle(20602).
S&F in double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
M&L for Pre-cast cement concrete block masonry with solid blocks type C-1, 1:3:6 (20mm graded agg) exc10cm in width and setting in mortar complete built in CM 1:6 in any description including demolition of old one complete all as specified and directed
M&L for 15mm thick cement plaster in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement with 2% of WPC on cement incl necessary scaffolding etc upto 12 mtr height complete all as directed.(Note:WPC shall be measurned and paid in separatetly) complete all as specified and directed
Supply only integral water proofing compound
M&L for rendering 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement, plaster with two coats of OBD of any tint over a with putty all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of wall including cornices, pillarsters by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing oily and greasy spots etc and applying one coats of OBD complete all as specified and directed
M&L preparation of new plastered of wall surfaces and applying two or more coats of premium Acrylic smooth exterior paint with silicone additives of required shade (Two or more coats applied @ 1.43ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) complete all as specified and directed
-Ditto- all as per item No 51 above, but on old surfaces of wall,chajja, ceiling etc complete all as specified and directed
M&L preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old wooden/wood base surfaces in any description and applying one coat of synthetic enamel paint complete all as specified and directed
Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in Brick/stone masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following
One light / wall / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
One ceiling fan point controlled by one, one way switch 6 Amps and regulator Note : PVC Casing caping / Pipe of size as required at site on surface of ceiling (only for fan point) in lieu of concealed is permitted and is deemed to be included in the unit rate quoated.
One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
Description all as per 55 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed
Supply and fixing Modular Switch - 6 Amps, Single pole one way, one module complete all as specified and as directed.
Supply and fixing Modular Bell push - 6 Amps, Single pole one way, one module complete all as specified and as directed.
Supply and fixing Modular Switch - 16 Amps, Single pole one way, one module complete all as specified and as directed.
S & F Modular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified and as directed.
S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed.
Supply and fixing, Ding Dong bell suitable for operation on AC. 230 volts, single pole complete all as specified and as directed.
Supply and fixing modular fan step regulator, 120W - 2 module suitable for ( 48" & 56" fans) supply complete all as specified and as directed.
S & F Ceiling rose, 3 phase / PVC / polycarbonate, complete all as specified and as directed
Supply and fixing 20/22 Watt Inverter LED Batten aluminium body with Opal Diffuser, IP20, Battery back-up & Functioning as per Product TDS with intregrated electronic driver, connector block, holder, decorative end caps, LED tube light etc complete with all accessories prewired and mounting PVC rectangular block, including provision of flexible copper conductor cable of suitable size from ceiling rose to connector and taking down old unserviceable fitting from existing postion for carrying to store, making good disturbed surfaces complete all as specified and as directed. Make Halonix Cat No LED INVERTER BATTEN HLB-08-22-CW-INV or equivalent in Havells, LHEXACP7FNIW020
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to connector, making good disturbed surfaces complete all as specified and as directed. Make Jaquar cat No -LGLZ01X010XW , Orient Cat No- LBLN-10-C-SQ
Taking down fan, Sealing cable end, dismantling blades and removing fan and blades from site and fixing or Hanging in existing position after proper cleaning , replacing unserviceable fan condenser 2.5 MFD and connecting up including provision of cable from ceiling rose or connector to fan after room plaster, colour complete all as specified and as directed.
S & F for plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers (as per Cat Part No -698502 of Make Indo Asian or equivalent Make- Bajaj Maxima DX/ Usha Crispair )including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed
Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
S & F sheet metal enclosure MCB DB SPN 8 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make - Schneider/Legrand/L&T/ABB.
S & F Vertical TPN Distribution Board in sheet metal enclosure double door 4 Way, 415 volts, 50 Hz, suitable for Flush Mounting and surface Mounting & provision for FP MCCB as incomer up to 125 Amps as I/C ( Frame1) and SP/TP MCB's as outgoing (Modules Optium F1+12) , With -100 Amps Copper insulated Busbar assembly for each phase, isolated Neutral bar, 2 Earthbar and Cable ties for cable management, IP 43 - #IK 09 with metal door including necessary cement work and electrical connections complete all as specified and as directed.
Supplied and fixed Four pole MCCB, Thermal Release Range 63-100 Amps, rupturing Breaking Capacity Icu at 415V AC 50Hz. 30 (kA) complete all as specified and as directed
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 6.0 Sqmm and one single core 6.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed.. Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length).
S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed. Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length).
S & F PVC rigid non-metallic flexible conduit ISI marked of dia 25 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system including where required all as directed by Engineer-in- Charge duly concealed in wall complete all as specified and as directed
S & F PVC rigid non-metallic flexible conduit ISI marked of dia 20 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system including where required all as directed by Engineer-in- Charge duly concealed in wall complete all as specified and as directed
Supply and install hi wall split units indoor/ & outdoor complete inverter type with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum not less than 4 star rating and EER 3.2.of capacity 1.5TR
S&F fabricated/ factory made angle iron stand suitable for fixing/mounting to outdoor unit of split AC, including grouting nut bolts, etc .
Supply and fix MCB Protected SRCD box 4 module 25 Amps with surface mounted PVC enclosure SRCD(socket residual current device) single pole with a three pin socket & top complete with 25 Amps MCB single pole. Make: Havells Cat part No DHDTCSN0251020 OR Equivalent Schneider/Siemens/Legrand.
M & L for copper tubing, confirming to relevant IS, of size 5/8 & 3/8" flare size or nearest size, 3 core 2.5sqmm copper cable, PVC drain pipe and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input between 170V to 250V with output voltage stabilized at 230V with accuracy of +- 2.5 and capacity 5KVA. (Make : V Guard/M Guard).
S & F Smart AC timer with digital temperature controller of size 100mm x 200mm x 100mm working on 220 volt, 50 hz and output of 25A, 230 voltwith diffterent indicator colour for two Acs all as specified and as directed.
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
MANIYA CONSTRUCTION CO
J P ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .