Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹12.1 L
Closing Date
27 Feb 2025, 8:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
RAJKUMAR S BIRADARA
Combined Package for,Work-A)Replacement of 1x12.5MVA, 66/11kV Power Transformer by 1x20MVA, 66/11kV Power Transformer at 66/11kV Bilikere Sub-station in Hunsur Taluk, Mysuru District.Work-B)Replacement of 1x8MVA, 66/11kV Power Transformer by 1x12.5MVA, 66/11kV Power Transformer at 66/11kV Madikeri Sub-station in Madikeri Taluk, Kodagu District.Work-C)Replacement of 1x8MVA, 66/11kV Transformer by 1x12.5MVA, 66/11kV Transformer at 66/11kV Besagarahally Sub-station in Maddur Taluk, Mandya District.Work-D)Replacement of 1x12.5MVA, 66/11kV Power Transformer-2 by 1x20MVA, 66/11kV Power Transformer at 66/11kV Koppa Sub-station in Maddur Taluk, Mandya District.Work-E) Replacement of 1x12.5MVA, 66/11kV Power Transformer by 1x20MVA, 66/11kV Power Transformer at 66/11kV K M Doddi Sub-station in Maddur Taluk, Mandya District on Partial Turnkey Basis, including Supply of all Materials/Equipments(Excluding supply of 11kV Switchgear) and Erection (including dismantling & Civil Works) of all Materials/Equipments, Testing and Commissioning
KPTCL/2024-25/SS/WORK_INDENT1965
KPTCL/2024-25/SS/WORK_INDENT1965
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CGM Tech Corporate Office Bengaluru
4 documents required · 4 mandatory
Documentary proof for clause no.3.2 (b)(i) of ITT, such as P.O, LOI, LOA, DWA, Work done, Performance Certificates issued by the end users not below the rank of Executive or Divisional Engineer.
Documentary proof for cl. no. 3.2 (a) of ITT (Financial Turnover): Audited Financial statements including Balance sheets, P&L statements, Turnover certificates and Auditors Reports of the last five years preceding the date of bid submission of the Bidder duly certified by chartered Accountant.
Documentary proof for Cl. No: 3.3 (b) of ITT (ie., Liquid Assets and /or availability of credit facilities) such Bankers Certificate duly signed by authorized person in the prescribed format as at Annexure XVIII of Section-4 and Details in Sch-5(9 of 5) of Techno-commercial sheets signed by authorized person
Documentary proof for Clause No: 3.6 of ITT: Assessed available tender capacity such as, Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years taking into account the completed as well as works in progress and Statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent as sought in Note of the said clause in the prescribed format as in clause No: 1.5 of Qualification Information.
Self-declaration as sought in Clause No. 3.6 Note (ii) of ITT by the Bidder stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct
Scanned copy of the Bank Guarantee towards EMD as per 13.1 of ITT
Super grade Electrical Contractors License
Power of Attorney in favor of all the persons signing the documents and a certified copy by the Company Secretary/ Authorized Signatory for power of attorney holder shall be attached as evidence for authentication as in Annexure X1 .
Letter of Undertaking for Bid validity as per Annexure-V of Section-4
Certificate of Incorporation of the Individual or any relevant document in respect of Partnership/Proprietorship firms as per the tender document
GST registration, PAN etc., in the State of Karnataka mandatorily at the time of execution of the Contract Agreement of the Tenderer as per clause no. 3.10 (xiii) of ITT .
No Deviation Certificate as per Annexure-I of Section-4
Undertaking to source the supply of equipment/material from KPTCL approved Vendors only .
Certificate is to be uploaded by the Tenderer agreeing to source the equipment material for the work from the Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as per Annexure XVII of Section 4.
Self-declarations in respect of Litigation, dis-qualification/Black listed due to non-performance & Risk & cost, Country which shares a land border with India as per clause no. 2.4 (b), (c), (d) & (e) of ITT.
The Qualification and experience of proposed for carrying out the Work.
Description of the Tools & Plant available with them for execution of the Work
The Tenderer shall upload declarations for Deviations, if any as per Schedule-5 and Schedule-6 of the Techno Commercial sheets
Information on litigations in which the Tenderer is involved as per prescribed format as at 1.12 of Qualification Information
Filled in Techno commercial sheet shall be uploaded along with all other QR documents. Price Offers shall be quoted in the item-wise bid Financial offer, provisioned in the e-procurement portal. In case the Prices are uploaded in/along the Techno commercial Bid, then Bid will be summarily rejected. The Techno-commercial sheets shall be uploaded in KPTCL excel formats only
Proposed methodology and program of construction as per clause No.1.13 of Section-3-Qualification Information
Type test reports as per tender documents / technical specifications
Copies of original documents defining the Constitution or legal status, Place of Registration(upload copy) and Principal place of business of the Bidder, written Power of Attorney of all persons signing subject tender documents (as per Annexure X1 of Section-4) alongwith copy of Resolution passed by Board of Directors/ all the Partners of the Firm
All details as called for in the Technical specifications of all the equipments/ materials of the Tender
Any other required documents as per the qualifying requirements, terms and conditions of the tender, NIT & Technical specifications
Certificate/Self declarations is to be uploaded as in Annexure-XVI & Annexure XVII
All Self-Declarations, legally enforceable deeds, Undertakings as per tender documents
₹7,500
₹12.1 L
19 Feb 2025
19 Feb 2025
28 Feb 2025
19 Feb 2025
19 Feb 2025
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricadin...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/tra...
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) inc...
Providing and fixing ridges, hips with asbestos cement sheet roofing with G.I. J or L hooks, bolts and nuts 8mm. dia G.I.plain and bitumen washers, serrated or plain wings, adjustable ridges, includin...
Providing and laying to required line and slope roofing with semicorrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, includ...
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete....
Removal, stacking and respreading of existing jelly as per the directions of the engineer in charge of the work including all costs labour, loading, unloading, transportation etc., complete and any ot...
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin...
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mm
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint ...
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost ...
Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work ...
Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth w...
Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and runni...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying of feet -PVC Batten with integrated LED tube LED light fitting 1 x 4ft - 36/40 W W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than ...
Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour wit...
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corne...
Providing and laying of bricks for UG cables
POWER TRANSFORMERS:
a) 20MVA, 66/11kV, 3-Ph, 50Hz, Core Type, 2 Winding Delta/Star transformer, vector group DYn11 with OLTC , RTCC Panel, first filling of Oil and 10% spare oil in non-returnable dru...
POWER TRANSFORMERS:
b) 12.5MVA, 66/11kV, 3-Ph, 50Hz, Core Type, 2 Winding Delta/Star transformer, vector group DYn11 with OLTC , RTCC Panel, first filling of Oil and 10% spare oil in non-returnable d...
FIRE FIGHTING EQUIPMENTS:
b) Supply,Erection, Testing & Commissioning of Nitrogen Injection fire extinguishing system as per the recommendation of the supplier of the fire fighting system for Power Tr...
ABC Relay-30,110V DC,4 NO, SR Contact, HR Flag, Type EMR261X3
i) 11 kV isolator, Double Break 400 A, 25 kA capacity with Roaster switch, with rigid bimetallic terminal connector suitable for coyote ACSR.
ii) 11KV isolator Single break 400 A, 25KA capacity with Roster switch with rigid bi-metalic terminal connector suitable for coyote ACSR.
CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor.
11 KV Class, 25KA, NCT of ratio 1200-800/1...
SURGE ARRESTOR : (Procelain/Polymer) metal oxide, gapless type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications..
1) 9kV, 10kA Class with connector and...
2) 60kV, 10kA, Class-II, Normal duty Metal Oxide type
Capacitor Bank :
Design, Engineering, Suppy, Erection (including civil works), Testing & commissioning of 2.9MVAR, 12.1KV capacitor Bank, Star connected, Double bank with internal fuses ternimal conn...
11kV ODS and take off structure
Supplying of Double pole structure with 9Mts. RCC poles,145Kg WL and with provision for fixing 11 kV 400 A Roaster single break isolators & provision for fixing 9kV l...
Total Weight of Mounting Structures, Stree Light Structure fabricated out of Galvanised Mild Steel (excluding Bolts & nuts) as per Technical Specification.
Note:Refer Techno Commercial Sheet for Break...
Total Weight of supply of Bolts & nuts of Mounting Structures, Stree Light Structure as per Technical Specification.
Note:Refer Techno Commercial Sheet for Break-up of Quantities
BUS BAR FORMATION :
ii) Coyote ACSR
1.1kV class PVC insulated copper control cables of following sizes with Lugs/Ferrules/Gland as per technical specifications:
i) 19 Core 2.5 Sq.mm.
ii) 4 Core 6.0 Sq.mm.
iii) 4 Core 2.5 Sq.mm.
vi) 2 Core 2.5 Sq.mm.
v) 2 Core 6 Sq.mm.
Note:Refer Techno Commercial Sheet for Break-up of Quantities
Post insulators- Cylindrical solid core as per 1S5350,Part II & III
66kV Class, 1Unit/Stack
Disc Insulators
Single Tension string of 90 KN. 1 units each 11kV
INSULATOR HARDWARE & CLAMPS as per technical specification:
a) Tension clamp with hardware to suit Coyote ACSR (11kV)
b) C type Wedge connectors(T-type) suitable for Coyote -Coyote
c) C type Wedge connectors suitable for Coyote -Drake
d) Post insulator clamp suitable for Drake ACSR and 66kV
11KV U.G. Cable with the required cable terminations as per technical Specification:
a) 11KV XLPE cable, 1Cx1000Sq. mm. Aluminium cable from 66/11KV transformer LV to 11KV Switchgear.
b) 11KV XLPE cable, 240Sq. mm. Aluminium cable 3 Core to be run from 11KV Switchgear to 11kV take off DP Structure.
c) Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable ( Indoor type )
d)Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable (Out door type)
e)Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable ( Indoor type )
f) Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable (Out door type)
Equipment's required for establishing SCADA Communication as per KPTCL Specification
a) Multi Functional Transducer(MFT)
b) Opto Coupler
c) Contact Multiplier Relay
d) Terminal Blocks (knife) for PT
e) Current Cables - copper core with c/s 4.0sqmm mutlistrand 7 core
f) Voltage Cables- copper core with c/s 2.5sqmm mutlistrand 4 core
g) Signal Cables- armoured copper core with c/s 0.5sqmm mutlistrand 10 core
h) Control Cables -copper core with c/s 1.5sqmm mutlistrand 10 core
Note : 1) Satellite communication required will be arranged by SLDC.
2)The detailed BOM & specification of SCADA equipment shall be...
b) Supply and installation/ Fixing/ Provision of Outdoortype Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shockproof, IP65 (WeatherProof), rustproof, dustproof, waterpr...
c) Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded p...
Erection Portion
POWER TRANSFORMERS:
a) 20MVA, 66/11kV, 3-Ph, 50Hz, Core Type, 2 Winding Delta/Star transformer, vector group DYn11 with OLTC , RTCC Panel, first filling of Oil and 10% spare oil in non-returnable dru...
POWER TRANSFORMERS:
b) 12.5MVA, 66/11kV, 3-Ph, 50Hz, Core Type, 2 Winding Delta/Star transformer, vector group DYn11 with OLTC , RTCC Panel, first filling of Oil and 10% spare oil in non-returnable d...
i) 11 kV isolator, Double break 400 A, 25 kA capacity with Roaster switch, with rigid bimetallic terminal connector suitable for coyote ACSR.
ii) 11KV isolator Single break 400 A, 25KA ...
CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor.
11 KV Class, 25KA, NCT of ratio 1200-800/1...
SURGE ARRESTOR : (Procelain/Polymer) metal oxide, gapless type with rigid bimetallic terminal connectors suitable for Drake ACSR as per technical specifications..
1) 9kV, 10kA Class with connector and...
2) 60kV, 10kA, Class-II, Normal duty Metal Oxide type
11kV ODS and take of structure
Supplying of Double pole structure with 9Mts. RCC poles,145Kg WL and with provision for fixing 11 kV 400 A Roaster single break isolators & provision for fixing 9kV li...
Total Weight of Mounting Structures, Street Light structure fabricated out of Galvanised Mild Steel (including Bolts & nuts) as per Technical Specification.
Refer Techno Commercial Sheet for Break up...
BUS BAR FORMATION :
i) Formation of Main/Cross bus with Single Drake for 66kV or 11kV Side
Bus Bar strengthening :
Supply and Modification for existing MCVCB 11kV switchgear Bus-bar system with RYB common copper Bus-bar for HT feeder panel suitable for 11kV MCVCB 500MVA, 31.5kA, 2000A incom...
1.1kV class PVC insulated copper control cables of following sizes with Lugs/Ferrules/Gland as per technical specifications:
i) 19 Core 2.5 Sq.mm.
ii) 4 Core 6.0 Sq.mm.
iii) 4 Core 2.5 Sq.mm.
Post insulators- Cylindrical solid core as per 1S5350,Part II & III
66kV Class, 1Unit/Stack
11kV,500 MVA, Metal Clad VCB switchgear (1600 A for Incomer and 1250 A for feeders),Out door type, each comprising of 1IC+8F+1BC+1AP3(Remote annunciation cum Control panel) with CTs & PTs and term...
11kV,500 MVA, Metal Clad VCB switchgear (1600 A for Incomer and 1250 A for feeders),Out door type, each comprising of 1IC+2F+1AP+1CB(Remote annunciation cum Control panel) with CTs & PTs and termi...
11 kV PCVCB outdoor type, KIOSK, 350 MVA rupturing capacity, 800 A(1250A for incomer & 800A for feeders) comprising of 2 No Feeder (remote annunciation cum control panel) with CTs & PTs and terminal...
11kV PCVCB Incomer swithgear of 500 MVA,25KA,1600A Panel Suitable for 20 MVA power tranformer with CTs & PTs and terminal connectors suitable for Drake/Coyote ACSR etc.,complete as per technical spec...
11KV U.G. Cable with the required cable terminations as per technical Specification:
a) 11KV XLPE cable, 1Cx1000Sq. mm. Aluminium cable from 66/11KV transformer LV to 11KV Switchgear.
b) 11KV XLPE ...
c) Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable ( Indoor type )
d)Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable (Out door typ...
e)Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable ( Indoor type )
f) Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable (Out door type)
Equipment's required for establishing SCADA Communication as per KPTCL Specification
a) Multi Functional Transducer(MFT)
b) Opto Coupler
c) Integration of RTU, DCU and UPS with field equipments
a) Current Cables - copper core with c/s 4.0sqmm mutlistrand 7 core
b) Voltage Cables- copper core with c/s 2.5sqmm mutlistrand 4 core
c) Signal Cables- armoured copper core with c/s 0.5sqmm mu...
EARTH MAT FORMATION:
a) Supplying and laying MS.Flat 50 x 6 mm flat welding and applying ACB paint to welded portion and covering with soil as per drawing/standards without Sodium Bentonate clay (all...
b) Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting,
drilling of holes and c...
c) Providing 25 mm dia M.S. Rod 1.05 metre long earthmat spikes including heating, bending top 50 mm overlap flattening and making spike edge at one end driving into the earth below the
ground level ...
d) Grounding of equipment by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metre long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron we...
e) Supplying & fixing 450 mm dia 450 mm height 1.5" to 2" thick hume pipe collar (non ressure type) for earth pits including all lead and lifts etc..
DECOMMISSIONING
1a) Dismantling of 12.5 MVA, 66/11 kV, Andrew Yule & Co Ltd.,, /IMP Power/NGEF make Transformer & parts like bushings with inbuilt 66 kV CTs, releasing of oil from Transformer, etc,.c...
b) Moving of Transformer from the plinth to the loading point as per direction of site Engineer.
2) Releasing and re-erection of Equipments:
2a) Releasing and reerection of exisitng 11kV MCVCB
b) Releasing and reerection of existing 11kV class, 25kA, NCT of ratio 800-400/1-1A/11kV Bus coupler CTs
c) Releasing and reerection of existing Lightning Arrestors
d) Releasing and reerection of 11kV NCT structure-0.142t
e) Releasing and reerection of 11kV Cable termination Structure-0.069t
f) Releasing and reerection of High pedestal insulators Mounting structu...
3) Releasing of Equipments:
a) Releasing of exisitng 11kV PCVCB Panel (Incomer/Feeder/Annunciation)
b) Releasing of existing 11kV NCT/CTs
c) Releasing of existing 11kV DP Structure
d) Releasing of existing 11kV DP Isolators
e) Releasing of existing Lightning Arresters
f) Releasing of Coyote Conductor
g)Releasing of Drake Conductor
h) Releasing of existing 11kV feeders DP structure Roaster GOS and11kV double break bus GOS 400A
i) Releasing of existing NCT structure-0.252t
j) Releasing of existing 11kV cable termination structure-0.138t
k) Releasing of existing Lightning Arresters Structure -0.36t
l) Releasing of existing 66...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Pre Bid Meeting Proceedings WI1965.pdf
Others - Pre Bid Meeting Proceedings • 1.48 MB
Technical Spec.zip
Others - Technical Specification • 16.28 MB
Tender Doc WI1965.docx
Tender Document • 0.51 MB
Circulars and Guidelines.zip
Others - Circular and Guidelines • 3.00 MB
Advisory Note to Bidders.pdf
Others - Advisory Note to Bidders • 1.02 MB
Section 11a Techno-Commercial sheet WI 1965.xlsx
Techno-Commercial Worksheet • 0.67 MB
Detailed NIT WI1965.pdf
Others - Detailed NIT • 10.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .