| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Reasonable quote | |
| 2 | L2₹14.7 L+₹41,494.09 (2.90%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 Bidder | |
| 3 | L3₹15.3 L+₹96,675.19 (6.75%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 Bidder |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
27 Aug 2019, 6:00 pmClosed
GE JORHAT
GE Jorhat
CLEANING OF SEWER LINE, SPETIC TANKS,SOAKAGE WELLS, REPAIR/REPLACEMENT OF BROKEN,DAMAGED SEWER LINE, SEPTIC TANK/SOAKAGE WELL,REPAIR TO FOOTHPATH, FENCING,HARDSTANDING AT ROWRIAH,SARAIBARI AND BHALUKMARA UNDER GE JORHAT.
2019_MES_268597_1
8903/B/E8
Open Tender
Civil Works - Others
Item Rate
270 days
JORHAT
AS per NIT
4 documents required · 4 mandatory
₹500
GE JORHAT
₹24,000
Yes
30 Jul 2020
19 Jul 2019
28 Aug 2019
19 Jul 2019
27 Aug 2019
31 Jul 2019
20 Jul 2019 - 21 Jul 2019
Amount
Cleaning of sewage line, manhole of any dia/bore or size by deputing one labour per day for 08 hours (a shift) and by providing/using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage if any and including removing the waste outside MD land complete all as specified and as directed. (i) Total three numbers of unskilled worker shall be detailed per day by the contractor. (ii) The contractor shall pay to his labours in their Bank Account and statement of Bank Account shall be submitted to GE for his verification while claiming interim payment. (iii) The rate quoted below the aggregate of minimum wages and minimum provident fund to be paid thereon by the contractor shall not be considered for acceptance. Minimum wages shall be as applicable for unskilled workers under scheduled employment of [Employment of Sweeping and Cleaning excluding activities prohibited under the Employment of Manual Scavengers and Construction of Dry Latrines (Prohibition) Act, 1993.] published by the Central Government under the schedule.
Material, T&P and labour for cleaning/ desludging of septic tank/ soak well of any capacity and size users using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Demolition of brickwork or stone/boulder masonry, laid dry below ground level complete all as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer in charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for brick work with sub class 'B' brick laid flat as floor, drain bedded & jointed in CM (1:4) and pointed in CM (1:3) completeall as specified and as directed.
M&L for brick work with sub class 'B' brick laid on edge with width equal to lengh of bricks bedded & jointed in CM (1:4) and pointed in CM (1:3) complete all as specified and as directed.
M & L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
Cutting into existing manholes for connecting new drains of pipe of nominal size 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of internal dia 150 mm, set in cement mortar complete all as specified and as directed.
S & F PVC-U, type B as per IS 15328: 2003, socket and spigot ends, SDR 41, pipe series S 20, drain and sewer pipes in any length with elastomeric sealing rings joints, 160 mm dia, laid in trenches or in floors complete all as specified and directed by Engineer- in- charge .
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC branch piece, Wye (45 degree) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge .
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 75 mm, complete all as specified and directed by Engineer in charge.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S&F PVC valve less syphonic action type flushing cistern low level white, dual flush, ISI marked (IS: 7231) with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squat pattern etc , set with concrete and making good to floor including taking down existing complete all as specified & directed.
S&F vitreous china squating pan orissa pattern size 580x440 mm white with integral foot rest complete including Cement concrete (excl flushing cistern and flush pipe )but connecting to flushing pipe , anti symphonage pipe etc with and including lime concrete bedding and demolition of existing one complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Dismantling of RCC jali any description complete all as specified and as directed.
Dismantling of wrought or mild steel work of any description not otherwise described
M & L for precast cement concrete louvers and jallies, 40 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings but excluding frame and fixed in position using cement mortar (1:6) complete all as specified and as directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC.) any section embedded in natural ground, including taking out embedded portion and making good disturbed ground
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for preparation of new surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10 cm in width or girth and applying two coats of black bituminous paint complete all as specified and as directed.
Supply only galvanized steel chain link fence fabric of mesh size 50 mm X 50 mm, made out of 2.50 mm nominal dia of mesh wire.complete all as specified and as directed. (Note: Weight per SqM shall be checked by BOO)
Fixing only galvanized steel chain link fence fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed.
S & F in repairs galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to any type of standards, rails, straining bolts including securing or tying at crossings with and provision of galvanised iron binding wire, GI staples or steel pins, etc. complete all as specified and as directed (two strand of line wire will be measured as one unit).
S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and directed.
M & L for ceramic, unglazed, vitreous, acid resisting tiles as per IS 4457: 2007, 12 mm thick, area exceeding 0.06 sqm not exceeding 0.11 sqm, textured finish including 20 mm thick screed bed or bedding in cement mortar(1:4) set and jointed and pointed in neat white cement slurry with colour pigment to match (equivalent to endura industrial paving tiles of M/s Johnson or equivalent of Kajaria/RAK) complete all as specified and as directed.
Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc; vertical or to batter, work in rough finished curved surfaces of concrete concrete complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size aggregate in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
jawaharlal jaiswal and co
A M CHOUDHURY AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .