Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.9 L+₹2.2 L (5.41%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹43.8 L+₹3.1 L (7.69%)Rejected-AOC C 234 ADG P CHENNAI | L3 | Rejected-AOC Other than L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
10 Dec 2019, 6:00 pmClosed
GE DSSC
GE DSSC WELLINGTON BARRACKS POST, WELLINGTON, THE NILGIRIS, PIN 643 231.
SPECIAL REPAIRS TO GATE AND PILLAR, SERVANT QTRS OF CERTAIN UNITS AND SPL REPAIRS TO DRAINAGE IN BLDG NO 96 AT DSSC WELLINGTON.
2019_MES_299078_1
8080/E8
Open Tender
Civil Works
Item Rate
120 days
WELLINGTON
PLEASE REFER TENDER DOCUMENT AND NIT.
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹83,000
Yes
10 Sept 2020
19 Nov 2019
11 Dec 2019
19 Nov 2019
10 Dec 2019
26 Nov 2019
Amount
B/R PORTION Demolition of brick work or stone / boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc., and removing unserviceable debris off the premises all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and in pavings n.exc 15 cm thickness (below or above ground level) and removing unserviceable debris off the premises all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for such as manholes cover etc ( reinforcement cut as required to facilitate demolition) and removing unserviceable debris off the premises all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section in any position framed or unframed work etc, complete all as specified and as directed.
Dismantling timber scantlings as in fillets, rails, posts rafters, purlins etc., in framed/unframed work, n.exc 40 Sqcm in section in any position, complete all as specified and as directed.
Dismantling of wall and ceiling boards, (fibre, pulp, insulation, etc) or insulation boards /slabs /blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc) sheets in roof, complete all as specified and as directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each, and removing from site, complete all as specified and as directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) exc 1.50 Sqm and n.exc 4.00 Sqm each, and removing from site, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified and directed
M & L for providing PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick with excavated soil all as specified and as directed.
Removal of surplus excavated materials (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.50 m above the starting point all as specified and as directed.
M & L for Reinforced cement concrete (1:2:4) (Nominal mix), type B-1 (using 20mm graded crushed stone aggregate) as in slab, supported on walls, beams and columns in floors, roofs, landings, etc., complete all as specified and directed.
M & L for Plain cement concrete, (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels or drains, bottom of drains /filling of gaps between drain and road etc, all as specified and as directed.
Extra labour for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
M & L for walling of random rubble, uncoursed, well bonded, with best quality locally available harder stones such as granite, trap, basalt stone etc, bedded and solidly hearted built in CM (1:4) including necessary bond stones and pointing the unaccesible dressed surface with same mortar as the work proceeds all as specified and directed.
M & L for half brick thick brick wall with subclass 'B' bricks straight or curved on plan to any radius in built in CM (1:4) all as specified and as directed.
Dismantling of floor hearth or wall tiling including cement mortor bedding (but not backing) removing serviciable tiles to store and rubbish off the premises all as specified and as directed.
M & L for 25mm thick PCC (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) as in sub base of flooring, finished even and smooth without using extra cement all as specified and as directed.
M & L for glazed ceramic coloured tiles 300 mm x 200 mm x 7-8 mm thick as in vertical surfaces such as skirting, dado etc., set and jointed in neat cement slurry, pointed in white or coloured cement to match, laid over and including 10 mm thick rendering in CM (1:4) to receive tiles, complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bed or bedding layer of mortar in CM (1:6) all as specified and as directed.
M & L for use and waste of timber as in form work to sides and soffits of suspended slab, such as roof slab, floor slab, shelves and similar works, rough finished surfaces of concrete flat complete all as specified and as directed.
M & L for mild steel TMT bars 6mm to 8mm dia in reinforcement, as in strirups spaces etc., cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S & F for mild steel framed work such as trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc conforming to Fe 290 (Gde E-165) complete all as specified and directed by Engr-in-Charge.
M & L for 4mm thick Non asbestos fibre cement building boards fixed or laid /inserted to timber /GI /Aluminium /MS Frame work with screws complete all as specified and as directed.
S & F second class hard wood (Sal / Hollock) glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and as directed.
S & F second class hard wood plain, framed, panelled shutters, 35mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face venneers, sizes of members of shutters as specified in SSR Part I, Clause 8.24 (a)supplied, fitted to chowkats, complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ' C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and as directed.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and as directed.
S & F aluminium, anodised, barrel tower bolts of extruded section, 200mm long, complete all as specified and as directed.
S & F 300 mm size aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed.
S & F mild steel cold rolled Butt hinges, medium weight, 100 mm long, complete all as specfied and as directed.
S & F aluminium handles, cast type, anodised of size 150 mm long, complete all as specified and as directed.
S & F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed.
S & F Steel window hollow section (Double leaf, gauge and glazed) with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dove tailed or welded, complete all as specified and as directed.
S & F pressed steel frames of size 125 x 60 mm, 1.25mm thick, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and taring back side of frame, complete all as specified and as directed.
M & L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in filling of steel chowkats or frames complete all as specified and as directed.
S & F mild steel framed work such as grills , gratings etc, with ends of bars shouldered and /or riveted or forged in to spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tank and similar work conforming to Fe290 Gde -E-165 . complete all as specified and directed.
S & F 0.60mm thick galvanised , corrugated mild steel sheeting with two corrugations side lap in roof, walls etc with grade of zinc coating 275 and fixed with L type or J type or cranked hook bolts all as specified and as directed.
S & F Plain galvanished, mild steel sheeting 0.60mm thick, in ridges, hip, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
M & L for Second class Hardwood clean sawn battens exc 15 Sq.cm and n.exc 25 Sq.cm in sectional area, at 30 cm centres, complete all as specified and as directed.
M & L for Second class hardwood plain fillets square, rectangular or traingular in triangular in section, clean sawn, secured with nails or brads exc 13 Sq.cm and n.exc 25 Sq.cm, complete all as specified and as directed.
M & L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and as directed.
M & L Ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in lime mortar (1 :3) or cement mortar (1:6) complete all as specified and as directed.
M & L for providing 75 mm thick cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregate) as in floor/and pavings/ plinth protection, finished fair & even without using extra cement, complete all as specified and as directed.
Taking down cement plaster, any description, on brick or stone walls, etc. including raking out joints hacking for key, scrubbing down with water etc., and removing unserviceable debris off the premises all as specified and directed.
M & L for rendering 15 mm thick CM (1:6), on stone masonry surfaces or other than fair face of brick work or on one side lathing and finished the surface even and smooth without using extra cement all as specified and as directed.
M & L for raised pointing in CM (1:4) to random or polygonal rubble, uncoursed or brought upto courses including raking out joints to the joints of existing or new surfaces complete all as specified and as directed.
M & L for preparation of new plastered or unplastered surfaces of walls and applying two coats of white wash, complete all as specified and as directed.
M & L for peparation of old plastered or unplastered surfaces of walls and applying one coat of white wash, complete all as specified and as directed.
M & L for peparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted, complete all as specified and directed.
M & L for peparation of old or unplastered surfaces of walls and applying one coat of cement base paint white or tinted, complete all as specified and directed.
S & F 3 mm thick sheet glass ordinary quality, and glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and as directed.
S & F 3 mm thick figured glass pin head type and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and as directed.
M & L for prepartion of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed.
M & L for prepartion of old wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Taking up/down 15mm/ 20mm bore steel tubing and connections including cleaning for refixing or removal to store all as specified and as directed.
S & F steel tubes, 15 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specifed and as directed.
S & F steel tubes, 20 mm bore, galvanised, 'medium grade' with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor incl cutting chases for concealed work etc, complete all as specified and as directed.
S & F rotational moulded polyethylene water storage tank 500 litres capacity, ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, complete all as specified and directed.
S & F Bib tap, 15mm bore cast copper alloy, fancy type, screwed down, screwed for iron pipe, complete all as specified and as directed.
S & F 15mm bore Pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and as directed.
S & F 15 mm bore stop valves, cast copper alloy, fancy type, screwed down, high pressure, screwed both ends for iron pipe or union, complete all as specified and as directed.
S & F 20 mm bore stop valves, cast copper alloy, fancy type, screwed down, high pressure, screwed both ends for iron pipe or union complete all as specified and as directed.
S & F 20mm bore ball valves high pressure of PTMT for 20mm bore pipe with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms), complete all as specified and as directed.
S & F PVC connection suitable for 15 mm pipe with PTMT nuts and washers for both ends of length 450 mm long, complete all as specified and as directed.
S & F Sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes coupling , inlcuding bedding in cement mortar to dwarf wall or providing cantilever brackets, PVC waste pipe and connecting union to pipe overall size (915 mm x 460 mm), bowl size (410 mm x 330 mm x 160 mm) complete all as specified and as directed.
S & F Vitreous china squatting pan water closet, orissa pattern, size 580 x 440 mm, white with integral foot rests (excluding flushing cistern and flush pipe) including PVC (SWR) 'S' trap, provision of lime concrete and jointing to flush pipe, complete all as specified and as directed.
S & F 10 litres capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32 mm dia PVC flushing pipe and 15 mm dia 450 mm long PVC connection with PTMT waste coupling, complete all as specified and as directed.
S & F Vitreous china, wash hand basin, (white) of size 550 mm x 400 mm including PTMT waste coupling 32 mm dia with long screwed shank and fly nuts, PVC, medium grade 32 mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15 mm dia, 450 mm long with brass CP nuts and washers at both ends, complete all as specified and as directed.
M & L for Cudappah stone slab 20-25 mm thick any colour/shade machine cut and polished,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone slab including grinding and polishing;rounding, moulding the edges as required laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M & L for rendering 15mm thick in CM (1:4) mixed with WPC as per manufacturer's instruction on fair face of stone/brick surfaces, finished even and smooth without using extra cement all as specified and as directed. Note : WPC shall be measured and paid seperately.
M & L for PCC (1:2:4) type B-1 (using 20mm gradded stone aggregate) as in coping, cills, bands, lintels n.exc 1.5m length, string courses, apex stone, bed plates, kerbs and the like including form work, weathering,slightly rounded or chamfered angles and throating all as specified and directed.
M & L for 75mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of flooring all as specified and as directed.
M & L Chequered cement concrete pre-polished coloured tiles 300 x 300 x 25 mm thick, set jointed in neat cement slurry in floors with grey cement & pigment, laid over and including 15 mm thick screed bed in CM (1:6) all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed.
M & L for RCC (1:2:4) (Nominal Mix) type B-1 (using 20mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs under reamed piles and mass concrete all as specified and as directed.
M & L for RCC (1:2:4) ( Nominal Mix) type B-1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for mild steel TMT bar 10 mm dia and over cut to length, bend to shape required including cranking bending and with and including mild steel wire not less than 0.90 mm dia complete all as specified and directed.
M & L for use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for rough finished surfaces of concrete flat all as specified and directed by Engr-in-Charge.
M & L for use and waste of timber as in formwork to pillars, posts, struts, piers, columns, stanchions for rough finished surfaces of concrete flat all as specified and directed by Engr-in-Charge.
M & L for granite (of any type) 18 to 20mm thick maching cut, as in vertical surfaces of dado, wall and jointed with grey cement slurry and pointed with white cement with admixture of pigment of match to shade of granite stone including grinding and polishing types, laid over and including 10mm thick screed bed in CM (1:3) complete all as specified and directed by Engr -in-charge
M & L for framed work as in doors or gates of angle iron, tubular section, square bars and decorative ornamentals or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering door etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering ,running rails and guides ) and hanging , also fastening and fixing conforming to Fe 290 Gde E 165 all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound all as specified and as directed.
Demolition and breaking up of drain pipes (AC/SWG/RCC ) upto 200mm bore of any description and in any position complete all as specified and as directed.
All as per Item No 88 above, but above 200mm bore and upto 450mm bore complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 300 mm bore all as specified and directed.
M & L for Reinforced concrete pipes, 300mm bore, class NP2, laid in trenches and jointed with collars all as specified and as directed.
M & L for 300 mm dia UPVC (SWR) pipes, type 'B', single socketed, laid in trenches complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 450 mm bore all as specified and directed.
Labour for fixing only old reinforced cement concrete pipes of 450mm bore, class NP2, laid in trenches and jointed with collars all as specified and as directed. Note : Old serviceable RCC pipes obtained from dismantling shall be reused.
M & L for Reinforced concrete pipes, 450mm bore, class NP2, laid in trenches and jointed with collars complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore all as specified and directed.
M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed in cement mortar, complete all as specified and as directed.
M & L for 150 mm dia UPVC (SWR) pipes, type 'B', single socketed, laid in trenches complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore all as specified and directed.
M & L 100 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed in cement mortar, complete all as specified and as directed.
M & L for 100 mm dia UPVC (SWR) pipes, type 'B', single socketed, laid in trenches complete all as specified and as directed.
M&L Precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in cement mortar (1:6) complete all as specified and directed.
M & L for 10 mm thick rendering in CM (1:4 ) on brick /concrete surfaces, finished even and smooth without using extra cement all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, laid bedded and pointed in any mortar all as specified and as directed.
M & L for hard core of gauge exc 63 mm but n.exc 75 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled with power driven road roller 8 - 10 tonnes capacity to required gradient and slope to a true surface all as specified and as directed.
M&L for machine pressed precast concrete rubber moulded coloured interlocking paver block (approved) any shape and size conforming to IS 15658-2006 of 80 mm thickness M-35 Grade , laid over and incl 50mm thick crush Stone sand (M sand) cushioning complete all as specified and directed by Engr-in-Charge.
M & L for Precast cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in CM ( 1:4) complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
Removing excavated material (soils) to a distance exc 250 m but n.exc 500m and depositing where directed at a level 1.5m above the starting point all as specified and directed.
E/M PORTION Taking down old, unserviceable gate light of any type and any size including disconnecting of electric connection and junction box complete all as directed by Engr-in-Charge.
S & F Gate light fitting LED Coral type with spun aluminium landscape luminaire with IP 65 protection with fixing accessories complete all as specified and directed by Engr-in-Charge. Make : Havells, Cat No : CORALPT25WLED 757PSYMTOPC or equivalent of Philips/Luker.
S & F loop in- loop out fuse junction box of internal dimension 200 x140 x 95mm made out of FRP sheet with weather proof conopy and locking screw fitted with and including 6 Amps MCB - 1 No, 50 Amps rated 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing flush to posts/pillars including necessary fixing arrangements & making good the disturbed surface with and including taking down old unserviceable junction box complete all as specified and directed by Engr-in-Charge. Make : Sintex, Cat No: GSJB-2014 or equivalent in Hensel/OBO
Supply and lay Galvanized Iron pipe light Grade of dia 40mm for cable protection in trenches /ducts /floors or fixed on walls / roof / poles etc including suitable fixing accessories complete all as specified and directed by Engr-in-Charge. Make : Tata/Jindal/Prakash Note :- Wherever the protection pipes are to be laid /fixed on poles /walls /other surface the cost of clamping using appropriate size /type of MS clamps, nuts both etc, is deemed to be included in the unit quoted rates.
S & F in replacement PVC insulated flexible multicore round copper conductor cable of size 2 core 6 Sqmm including necessary end connector and taking down unserviceable cable complete all as specified and as directed. Make :Havells, Cat No: WHMFDSKB26X0 or equivalent of Finolex/Polycab.
Taking down old, unserviceable aluminium point wiring (light, fan, socket or power) complete, including fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as directed by Engr-in-Charge.
Taking down old sub-main wiring including fixture & fittings etc., and removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. all as specified and as directed.
Disconnecting /dismantling of old existing unserviceable DB's any way 240 /415 Volts with their old/unserviceable burnt MCB's all as specified and as directed.
M & L for surface point wiring with two single core 1.5 sqmm FRLS PVC Insulated, single core, multi stranded, copper conductor cable, 1100 volts grade, ISI marked in and including Rigid non -metallic (medium grade) PVC casing-caping on wall for one light/fan/call bell point controlled by one switch/buzzer with and including continuous 1.5 Sqmm FRLS PVC insulated single core copper conductor connected to common earth dolly, in and including the pressed steel terminal box of suitable size & thickness with 3mm laminated cover for mounting switch, sockets etc. complete for the following : (a) One Light/fan/call bell point controlled by one switch 5/6 Amps. Make : Havells/Finolex/Polycab Note :- (i) The wiring shall be done in proper color coding using red,yellow, blue for phases, blackfor neutral and green for earth.
(b) One switch socket out let point 5/6 Amps on same board.
(c) One switch socket out let point 5/6 Amps on independent board.
M & L for surface point wiring with two single core 2.5 sqmm FRLS PVC Insulated, single core, multi stranded, copper conductor cable, 1100 volt grade, ISI marked in and including Rigid non -metallic (medium grade) PVC casing-caping on wall for 15/16 Amps switch-socket outlets etc., on independent board complete and including continuous 2.5 Sqmm FRLS PVC insulated single core copper conductor connected to common earth dolly, in and including the pressed steel terminal box of suitable size & thickness with 3mm laminated cover for mounting switch, sockets etc. complete all as specified and directed by Engr-in-Charge. Make : Havells/Finolex/Polycab Note :- (i) The wiring shall be done in proper color coding using red,yellow, blue for phases, blackfor neutral and green for earth.
M & L for surface sub-main wiring alongwith earth wire of size (2 x 4.0) Sq. mm + (1 x 4.0) Sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC casing-caping (medium grade) with all fittings and accessories ISI marked in complete all as specified & as directed. Make : Havells/Finolex/Polycab Note : (i)Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length.
S & F switch socket combination, 5 in 1, 5/6 pin, 15 Amp flush type, 240 volts, ISI marked complete all as specified and as directed. Make : Havells / Anchor/ C & S/ Legrand.
S & F switch piano, flush button, single pole, one way, 5/6 Amp, 240 volt, ISI marked complete all as specified and as directed. Make : Havells / Anchor/ C & S/ Legrand.
S & F switch socket outlet 5 Pin, 5/6 Amp flush type, 240 volts, ISI marked complete all as specified and as directed. Make : Havells / Anchor/ C & S/ Legrand.
S & F socket only 5 pin 5/6 Amp flush type, 240 volts, ISI marked complete all as specified. Make : Havells / Anchor/ C & S/ Legrand.
S & F bell push, flush type, 5/6 Amps complete all as specified and as directed. Make : Havells / Anchor/ C & S/ Legrand.
S & F call Bell, AC, Ding Dong type 230 Volt all as specified and as directed. Make : Anchor Cat No : 8272 or equivalent in Legrand/C&S/Havells.
S & F ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts, ISI marked complete all as specified & as directed. Make: Havells/CG/Anchor
S & F ultra slim elegance LED lighting fixture with extruded AL heat sink, 20 W, 4ft energy efficient and environmental friendly including electric connection with & including flexible hose pipe from ceiling rose to fitting complete all as specified and directed by the Engr-in-charge. Make : Havells, Cat No : ENDURALINEARNEO BS20WLED865SPCWH or equivalent of Luker/Philips.
S & F compact & sturdy LED decorative fixture (10 W) with extruded heat sink, multi purpose lighting in replacement of 2ft FTL fittings including electric connection with & including flexible hose pipe from ceiling rose to fitting complete all as specified and directed. Make : Havells, Cat No: ENDURALINEARNEO BS10WLED865SPCWH or equivalent of Luker/Philips.
S & F wall mounting decorative fixture SS finish with opal glass diffuser with and including 5 W warm white LED lamps of E14 Cap complete all as specified and as directed. Make : Havells, Cat No: LHJE04104499 ( For Fixture) or equivalent in Philips/Luker. Make : Havells, Cat No: LHLDEROEMD9X005 (For Lamps) or equivalent in Philips/Luker.
S & F energy saving new generation 10 W LED, bulk head luminaire with opal diffuser with and including lamp LED 6000K complete all as specified and as directed. Make: Havells, Cat No :RUGBYNEONFT10W LED860SSYMTOPC or equivalent models in Philips/Luker.
S & F LED light fittings of 25 W rating, 6K colour temperature with IP 66 protection fixed to the wall using suitable GI bracket, GI pipe and nut bolts, making connections from ceiling rose etc., including electric connection with & including flexible hose pipe from ceiling rose to fitting complete all as specified and as directed. Make:Havells Cat No: ENDURAPEARLSL25W LED757SASYTOPC or equivalent in Philips/Luker.
S & F exhaust fan ,single phase, 250mm sweep, PVC body with their all accessories fixed properly on window/ stone wall surfaces of thickness not exceeding 50cm including making proper sized exhaust hole of 250 mm dia, Louver Shutter suitable for the same exhaust fan and which shall easily be operated with exhaust air pressure. Any disturbed surfaces of wall shall be made good by cement work/plastering and matching by existing colour white/colour wash including removing of old exhaust fan and connecting/testing complete all as specified and as directed. Make: Havells ,Code:Venti Air-DX White or equivalent in Almonard/ Usha. Note : Old exhaust fans shall be handed over to E/M Store yard.
S & F MCB, DB, TPN, 6 ways, double door type, IP-43, IK-09 with metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. Make: Havells, Cat No: DHDNTHODDW06 or equvalent in Legrand/L&T. Note:The MCCB and MCB's shall be paid separately under relevent items.
S & F MCB TPN, 63 Amps rating, 415 Volts, as ordered by breaking capacity 10 KA, `C' Series all as specified and directed. Make: Havells, Cat No: DHMGCFPF063 or equivalent in Legrand/L&T.
S & F sheet metal enclosure for 6 way DBs double door type 240 volts, 200 Amps rated bus-bar IP-43,IK-09 with metal door, including necessary connection all as specified and as directed. Make: Havells, Cat No :DHDNSHODDW06 or equivalent in L&T/ Legrand.
S & F Sheet metal enclosure for 2 way DBs double door type 240 volts, 200 Amps rated bus-bar IP-43,IK-09 with metal door, including necessary connection all as specified and as directed. Make: Havells, Cat No:DHDNSHODDW04 or equivalent in L&T/ Legrand.
S & F miniature circuit breakers, single pole,C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA all as specified and as directed. Make: Havells,Cat No:DHMGCSPF006-032 or equvalent in L&T/ Legrand.
S & F miniature circuit breakers, SP&N, C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA all as specified and as directed. Make:Havells, Cat No: DHMGCSNF006-032 or equvalent in L&T/Legrand.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth lead of wire strip earthing 32 x 6mm by means of GI bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection (upto 7.5m long) & common salt, charcoal in alternate layers etc. complete all as shown in Electric Plate No 3 of SSR Part 1 and testing on completion including taking down old earthing all as specified and as directed. Note: If necessary earth resistance value not obtained after testing, the conractor should do fresh earthing at free of cost.
Supply and laying in trenches /through pipes or bare in road crossings / paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. UG cable, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4 Core 16 Sqmm , all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab
Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc., UG cable, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 2 Core 10 Sqmm , all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab.
Supply and laying sub class 'B' bricks of size 230 x 115 x 75 mm laid across the cable for cable protection, above sand complete all as specified and directed.
Supply, spreading and compacting of approved river bed sand or M sand in trenches for cable cushion on both top and bottom of cable, including ramming all as specified and as directed by Engineer-in Charge. Note : Punned thickness shall be measured.
Supply, fix and test, in replacement of LED Street light fitting of capacity 60 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous efficacy not less than 100 lumen/watt, 6000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection,phase to phase protection, over voltage protection,surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories and connecting up complete including taking down old unserviceable one and all as specified and directed by Engr-in-Charge. Make: Havells, Cat No: ENDURAPEARLPLUS SL60WLED757SASYTOPC , or equivalent in Philips/Luker. Note :- Test certificates in support of the technical parameters of the light fittings is to be submitted in original to the Engr-in-Charge by the contractor.
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete in the location as specified and directed by Engr-in-Charge. Make :- Jindal/Chennai poles/Natonal Tubing Company. Note: Earth work and PCC shall be measured and paid separtately.
SREERAM
GMS Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .