Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹45.8 LAccepted-AOC | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹53.6 L+₹5.9 L (12.5%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | 2 | Rejected-Finance Being L2 | |
| 3 | 3₹55.5 L+₹7.8 L (16.3%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 3 | Rejected-Finance Being L3 | |
| 4 | 4₹56.6 L+₹9.0 L (18.8%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 4 | Rejected-Finance Being L4 | |
| 5 | 5₹58.1 L+₹10.4 L (21.8%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | 5 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
9 Oct 2023, 6:00 pmClosed
CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
SPECIAL REPAIR AND REPLACEMENT OF LT CABLE TO UG CABLE IN OLD AND NEW KSE AREA AND UNIT AREA UNDER GE NORTH PATIALA
2023_MES_618235_1
CWE/PAT/T-36/2023-24
Open Tender
Electrical and Maintenance Works
Works
180 days
PATIALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE NORTH PATIALA
₹1.4 L
18 Nov 2023
11 Sept 2023
11 Oct 2023
11 Sept 2023
9 Oct 2023
25 Sept 2023
11 Sept 2023 - 24 Sept 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified.
All as per item No. 01 above but exceeding more than 1.5 m and n.exc 3.0m in depth complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Material & Labour for sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
Material & Labour for Un-reinforced precast concrete cable cover class LV, type 2, flat, size 250 mm X 150mm x 40mm complete all as specified and directed.
Taking up or down worn out/ damaged / partly serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors of size 10 sqmm x 4 core,1100 volt grade from duct/pole/wall/roof tops etc, testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable, keeping aside serviceable cable in safe custody for reuse complete all as specified and directed
All as per item No. 7.00 above but of size 16 Sqmm X 4 core
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
All as per item No. 9.00 above but of size 16 Sqmm X 4 core
All as per item No. 9.00 above but of size 25 sqmm X 4 core
All as per item No. 9.00 above but of size 35 sqmm X 3.5 core
All as per item No. 9.00 above but of size 70 sqmm X 3.5 core
All as per item No. 9.00 above but of size 95 sqmm X 3.5 core
All as per item No. 9.00 above but of size 120 sqmm X 3.5 core
All as per item No. 9.00 above but of size 300 sqmm X 3.5 core
Refixing and laying, commissioning and testing or passing through pipe, XLPE insulated armoured electric power UG cable (Heavy Duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension / replacement of the defective cable of nominal cross sectional area 10 Sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and as directed. Note : (i) Old servicable cable of any size obtained from Sr Item No 7.00 shall be reused. (ii) Pipes and Un-reinforced precast concrete cable cover for protection, mild steel clamp nut and bolts, sand cushioning and Earth work shall be measured and paid separately.
Refixing and laying, commissioning and testing or passing through pipe, XLPE insulated armoured electric power UG cable (Heavy Duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension / replacement of the defective cable of nominal cross sectional area 16 Sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and as directed. Note : (i) Old servicable cable of any size obtained from Sr Item No 8.00 shall be reused. (ii) Pipes and Un-reinforced precast concrete cable cover for protection, mild steel clamp nut and bolts, sand cushioning and Earth work shall be measured and paid separately.
Supply and erecting steel tubular swaged pole 9 Mtrs long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31 with relevant IS and painting the pole upto 5 feet from ground level with black and yellow alternate strip of 30 CM each with synthetic enamel paint and providing GI pipe bend to shape 32mm dia , length upto 2 mtr duly fixed with necessary clamp for mounting of LED security light all as specified & directed. Note : Earth work, PCC shall be measured and paid separately.
Supply and fix in repair loop type insulators porclain shackle type vitreous white, brown or green of size 65mm x 90mm overall dimension and 20 mm clearance hole complete all as specified and as directed.
Material & Labour for Stay assembly in replacement with accessories as shown on electrical plate No 1 of SSR Part-I, 2009, complete all as specified and as directed.. NOTE: Stay Wire, loop type Insulator, stay clamps, earthwork and concrete shall be measured and paid for separately.
Supply and fix in replacement of stay wire galvanised iron stranded of size 7/3.15 mm, length of stay wire not exceeding 11 mtrs with each stay and fixed to stay and pole including tightening complete all as specified and as directed.
Material & Labour for Dismantling of ACSR conductors after unbinding from insulators Note:- (i) Total no of conductors in over head line to be taken down shall comprise a maximum of three phase, one neutral ,one street light/security light for measurement length of each conductor shall be taken separately, All as specified and directed by Engineer in Charge.
Supply and fix in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters and conventional skull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washers of size 200mmx 150 mm for LT Note : (Note:-the printing shall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .)
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Material & Labour in replacement or Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing complete all as specified and shown in electric plate No 3 of SSR Part I.
Material & Labour in replacement or Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 25X4mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing complete all as specified and shown in electric plate No 3 of SSR Part I.
Material & Labour in replacement for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI wire 4mm dia by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 15mm dia GI pipe light grade for projection of earth lead, wire mesh and connected to earth point including testing complete all as specified and shown in electric plate No 3 of SSR part I.
Material & Labour for cement concrete type D2, 1:4:8 using 40 mm graded broken stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Material & Labour for cement concrete type B1, 1:2:4 using 20 mm graded broken stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed .
Material and labour for cement concrete type C1, 1:3:6 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement complete all as specified and as directed.
Material and labour for Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed. Note:- Necessary concrete work to be measured and paid separately.
Material and labour for cable route indicator post of size 600mmx200mmx100mm round shape at top made out of pre cast cement concrete 1:2:4 type B1 and grouting the same in ground using PCC 1:3:6 type C1 bock of size 250mmX150mmX150mm including plastering of exposed surface by using CM 1:4 and finished even and smooth without using any extra cement applying two coats of cement based paint on plastered surface including writting/marking letters and conventional skull and bone in postal red color letters like LT 1100 Volts UG cable, MES, all as per direction of Engr-in-Charge.
Material & Labour for cable jointing kit for 1100 Volt grade cable indoor/outdoor heat shrink type joint complete with jointing material and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified and as directed..
Supply,laying,galvanised steel tubing light grade complete with all fitting of size 40 mm dia for cable protection along with pole across road etc. Complete all as specified and as directed.
All as per item No. 35.00 above but size of pipe 50 mm dia.
All as per item No. 35.00 above but size of pipe 80 mm dia.
Supply and fixing street light junction box of size 250 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed.
Supply and fixing in repair PVC insulated round/flat copper cable of size 3 core, 1.5 Sqmm for connection of LED lights from FRP junction box to street light fitting including PVC conduit 20 mm dia complete all as specified and as directed.
Supply and fixing in repair of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2 complete all as specified and as directed.
Supply,Install, Testing and commissioning of self supporting totally enclosed factory fabricated LT feeder pillar box , made out of 3 mm thick MS sheet with projected globe roof for rain water protection ,dust and vermin proof, hinged double door shutters with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip, ventilation louvers, bottom detachable gland plate complete with suitable size zink chromium plated nuts, bolts and washers etc outdoor type cubicle panel board suitable for 3 phase 4 wire ,415 volts 50 hz and 50mm x 50mm x 6 mm angle iron frame ,weather proof ventilated with locking arrangement ,including provision of suitable size PCC pedestal for mounting of panel board and comprising the following of size not less than 1.2 m X 1.5 m X 0.45m and including taking down the existing feeder pillar panel board. :- Note Excavation and PCC for grouting/fixing at a height not less than 0.6 Mtr of Panel is including in the quoted rate. (i)Aluminium Bus Bar 63 A supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with heat shrinkable colour coded PVC sleaving for three phase and neutral -01 Set (ii)MCB TPN 40 A 16 KA 415 Volts 50 Cycles-01 No (as incoming) (iii)MCB TP 10 A 16 KA 415 Volts 50 Cycles-1 Nos(as outgoing) (v)LED Phase Indication Lamp-03 Nos( R,Y,B) with switch control (vi)Contactor set for 3 pole contactor AC-3 phase 40 A 415 Volts (vii)Electro Mechanical Timer Switch 230V ,6 A-01 Nos (viii)The feeder pillar box shall be mounted on PCC pedestal of size 600 mm X400 mm and 700 mm height (02 Nos for each panel board),with cement concrete 1:2:4 type B1 using 20 mm greaded stone aggregate. (ix) The rate quoted shall be demed to include for the above provisions.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and as directed.
R D Bansal
Jawandha Enterprises
SWAMI ENGINEERS
UNITED ENGINEERING CORPORATION
MAHESH KUMAR SINGLA CONTRACTOR
unique power & control system
Leo Air and Power Solution pvt Ltd.
DELTA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .