Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.1 Cr+₹19.7 L (6.81%)Rejected-Finance | ₹3.1 Cr+₹19.7 L (6.81%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹3.3 Cr+₹39.2 L (13.6%)Rejected-Finance | ₹3.3 Cr+₹39.2 L (13.6%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹3.4 Cr+₹51.2 L (17.7%)Rejected-Finance | ₹3.4 Cr+₹51.2 L (17.7%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹3.5 Cr+₹63.3 L (21.9%)Rejected-Finance 3 4 520 TO 526 FLAT NO 303 PRAGATHI PRIDE APARTMENT BARKATHPURA HYDERABAD 500027 | HYDERABAD | TELANGANA | 500027 | ₹3.5 Cr+₹63.3 L (21.9%) | L5 | Rejected-Finance Rejected |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
3 Feb 2020, 3:00 pmClosed
CCE(RND) S
The Chief Construction Engineer (RND), PB No.1569, Akbar Road, Secunderabad 500003
Special Repairs to Married accommodation of Officers and Staff at CCE (RnD) South complex, Secunderabad
2019_DRDO_529991_1
83559/CIV/SEC/Con
Limited
Civil Works
Item Rate
540 days
Secunderabad
As per NIT
2 documents required · 2 mandatory
₹2,000
Yes
CCE(RND) SECUNDERABAD
₹5.2 L
Yes
27 Apr 2020
23 Dec 2019
4 Feb 2020
23 Dec 2019
3 Feb 2020
17 Jan 2020
24 Dec 2019 - 26 Dec 2019
Amount
Supplying chemical emulsion in sealed containers including delivery as specified.
a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST- ONSTRUCTIONAL antitermite treatment (excluding the cost of chemical emulsion) :
a) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
i) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Diluting and injecting chemical
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
i) Size of tile 600x600 mm.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. (Make Kajaria/Somany/Jhonson).
Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. (Items 6 & 8 above)
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (Make Kajaria/Somany/Jhonson).
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Dismantling tile work in floors, walls and roofs laid in cement mortar including stacking material within 50 metres lead.
i) For thickness of tiles 10 mm to 25 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Dismantling brick work in cement mortar.
Credit for the serviceable material obtained out of dismantling at above item.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand).
15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand).
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand).
a) Providing and fixing factory made uPVC sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly inforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length shape & size according to uPVC profile), appropriate imension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
i) Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
ii) Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm).
Supply and fixing of pre painted steel sliding windows - 2.5 track sliding window with mesh shutter - (2-glass shutters and 1 - mesh shutter) fabricated from roll formed sections made of galvanized steel colour coated/powder coated (Base steel as per IS 513 `D' quality, galvanized as per IS 277 with zinc of 120 GM/Sq.mtr) with totoal coated thickness of 0.58mm. Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyster paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyster powder up to 50-60 microns thick. Section for external frame should be of 45 x 95mm. Section for glass shutter should be 36 x 50 mm and mesh shutter should be of 20 x 46 mm. Section for euro groove should be 25 x 24 mm and lap strip should be of 21 x 4 mm (Aluminium) and touch lock for window. Section for external frame of fixed part should be of 60 x 37mm. Section for mullion fixed part should be of 48 x 50mm. Section for fixed part beading should be of 12 x 12mm. Corner bracket for internal and external frame made of glass filled mylon. Gaskets are to be made of Ethyl propylene diamine monomer (EPDM). The sections are to be cut to length, joined and assembled by means of corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding brackets & screws including 10mm square guard bars with 6" pitch (152.4mm).
a) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
i) For fixed portion
a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
i) Powder coated aluminium (minimum thickness of powder coating 50 micron)
a) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
i) With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
b) Providing and fixing fly proof galvanized S.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing hardware fittings ISI marked aluminium.
a) Hinges of size 100x75x4 mm
b) Handles 125mm
c) Tower bolt 200mm
d) Sliding door bolt 200x16mm
(a) Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
(b) Credit for the serviceble material obtained out of dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
a) Area of slab upto 0.50 sqm (Kitchen platforms)
b) Area of slab over 0.50 sqm (Staircases)
White washing with lime to give an even shade, New work (three or more coats)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm).
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (steel surfaces).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
a) Providing and laying UV resistant roof top water proofing systen consisting of : (i) Surface preparation of providing and cleaning the floor surface, to make it free from dirt, dust, loose particles, laitance and other contaminants by grinding etc., as per manufacturer's specifications. (ii) After cleaning the surface cut open the cracks and fill it up with cementaitious poly grout if the width is below 5mm. If the width is above 5mm fill it up with polyurethane sealant. (iii) Then system followed by supply and application of ardex P-51 as primer over the surface. iv) Supply and application of ardex WPM 158 high build, single component, elastomeric polyurethane based waterproofing membrane as a topcoat over the primed surface.
a) Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 110 mm including dismantling of existing broken pipes.
b) Credit for the serviceble material obtained out of dismantling
a) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.including dismantling of existing deterioated tanks.
b) Credit for the serviceble material obtained out of dismantling
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
a) Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws: Kiln seasoned and chemically treated hollock wood.
b) Credit for the serviceble material obtained out of dismantling
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete
a) Single rubber stopper
b) Twin rubber stopper
Providing and fixing stainless steel sliding door bolts of approved make, confirming to grade AISI-304 in 18/8 composition with nuts and screws etc., complete 300x16mm dia
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with nuts and screws etc., complete 300x16mm dia
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary crews etc. complete
Providing and fixing of aluminium hinges 100x63x4 mm.
a) Providing and fixing wire gauge shutters using galvanized S.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :
b) Credit for the serviceble material obtained out of dismantling
a) Dismantling of existing wooden pelmet box.
b) Credit for the serviceble material obtained out of dismantling.
a) Providing and fixing S.S. curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 20 mm diameter.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :
a) Kitchen sink with drain board (Make Anupama/Nirali)
i) 510x1040 mm bowl depth 225 mm
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
Providing and fixing of Health Faucet of quality & make as approved by Engineer in charge.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : a) 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. a) 15mm nominal bore
a) Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter.
b) Credit for the serviceble material obtained out of dismantling.
a) Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
(b) Dismantling of existing of M.S. Railing.
(c) Credit for existing M.S.Railing in falusters, vertical & horizontal.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
a) M.S. tube
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (i) 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (i) 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (i) 15 mm nominal outer dia Pipes
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more
Providing and fixing of cupboard of 600mm deep with 2/3 Nos. openable shutters (width of each shutter not exceeding 500mm), vertical dividers and two shelves made out of 18mm commercial ply wood with 1mm laminate board for exposed external surfaces and 0.6mm for internal exposed surfaces, all exposed edges to have teak wood lipping with spirit polish. Hardware shall include SS tower bots, 100mm long 'C' type SS handles, , SS hanger rod, auto closing hinges, ball catchers and locks, all complete as per directions of engineer-in-charge.
Providing and fixing 300mm deep, 600mm high overhead storage units in kitchen with openable shutters and one shelf inside all made with 18mm thick commercial plywood with approved laminate for top, sides, bottom and for shutters and providing 12mm tick commercial plywood for back, 20x6mm teakwood beading for exposed edges with spirit polish, SS hinges, handles, ball catches etc., all complete as directed by engineer-in-charge (All exposed external surfaces of plywood surfaces to have 1mm thick laminate, internal exposed surfaces to have 0.6mm thick lamination and all other unexposed internal surfaces to have synthetic enamel paint).
Providing and fixing of openable shutters below kitchen platform made out of 25x50mm second class teak wood frame work and 18mm thick plywood with 1mm lamination for shutter, teak wood beading of size 20x6mm to edges and exposed surfaces duly spirit polished hardware fittings like hinges, ball catchers and handles etc complete all as directed by engineer-in-charge (All exposed external surfaces of plywood surfaces to have 1mm thick laminate, internal exposed surfaces to have 0.6mm thick lamination and all other unexposed internal surfaces to have synthetic enamel paint).
Providing and fixing of built in cupboard of 600mm deep with 2/3 Nos. openable shutters (width of each shutter not to exceed 500mm), vertical partitions and two shelves made out of 18mm ply wood with 3.5mm thick teak veneer to all exposed edges to have teak wood lipping with melamine polish and limination to internal surfaces. Hardware shall include SS tower bots, 100mm long 'C' type SS handles, auto closing hinges, ball catchers, SS hanger rod and locks, all complete as per directions of engineer-in-charge (All exposed external surfaces of plywood surfaces to have 3.5mm thick teak veneer with melamine polish, internal exposed surfaces to have 0.6mm thick lamination and all other unexposed internal surfaces to have synthetic enamel paint).
Supplying and fixing of 750x900mm size stainless steel kitchen plate rack of approved make.
E&M Works
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Removal of exisiting GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A odular switch, connections etc. as required.
Removal of exisiting GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A odular switch, connections etc. as required.
Supply and Fixing of light fittings (7W) LED type
Removal of exisiting light fittings (7W) LED type
Supply, Installation, testing and commissioning of 18W LED Tube light with Batton / pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Removal of exisiting Tube light with Batton / pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply, Installation of exhaust fan of 350 mm in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep.
Removal of exisitng exhaust fan in the existing opening, including wiring etc. as required. Upto 450 mm sweep.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Removal of exisitng of call bell/ buzzer suitable for single phase, 230 V, including wiring complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Removable of modular switch/ socket from the existing modular plate & switch box including connections and modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, of 1200 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
RemovaI of exisiting ceiling fan, of 1200 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (i) Group B
Removal of exisiting Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (i) Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Removal of exisiting Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Removal of exisiting Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Details of MCB DB as per Appendix attached.
i) Type M1 - MCB DB - 16A = 4 Nos, 10A = 2 Nos, 32A = 1 No
ii) Removal of exisiting Type M1 - MCB DB - 16A = 4 Nos, 10A = 2 Nos, 32A = 1 No
iii) Type M2 MCB DB - 16A = 4 Nos, 10A = 3 Nos, 32A = 1 No
iv) Removal of exisiting Type M2 MCB DB - 16A = 4 Nos, 10A = 3 Nos, 32A = 1 No
v) Type M3 MCB DB - 16A = 5 Nos, 10A = 4 Nos, 32A = 1 No
vi) Removal of exisiting Type M3 MCB DB - 16A = 5 Nos, 10A = 4 Nos, 32A = 1 No
vii) Type M4 MCB DB - 16A = 5 Nos, 10A = 5 Nos, 32A = 1 No
viii) Removal of exisiting Type M4 MCB DB - 16A = 5 Nos, 10A = 5 Nos, 32A = 1 No
ix) Type M5 MCB DB - 16A = 6 Nos, 10A = 6 Nos, 32A = 1 No
x) Removal of exisiting Type M5 MCB DB - 16A = 6 Nos, 10A = 6 Nos, 32A = 1 No
MV Panels
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK08 to IK-10 Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-6X degree of protection wiith external door. Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 45 degree centrigrade. Adjustable plinth height for better spreading of cables. The plinth has got the height of 100 mm made of 4 corners and side plates. The side plates can be removed to make a path for cable entry. Plinths can be placed on top of each other for better spreading of the cables. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. The PCC shall have at least two spare cubicles. The size of all Panel Mounting Meters shall be 96X96mm.
All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases with Icu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits. Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. In case of 4 pole ACB, neutral rating shall be 100% of phase.ACBs shall have same height & depth for entire range irrespective of frame size. ACBs shall have Icu=Ics=Icw (Icw rating shall be for 1 sec). ACB's shall have ready to close contact. ACB release shall have individual indiaction LEDs for faults (L,S,I,G). ACB release shall be provided with built-in LCD display for
The microprocessor based release should have the following minimum settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.5 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction.
• MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material.
i) Sub : Substation I/C Panel
Incomer:
630A, ATS, 4 Pole ATS with C20 intelligent controller with Auxiliary Contacts(2NO+2NC)
630A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C & E/F Protections (Ics=100%Icu).
Extended Rotary Operating Handle for 630A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 630A MCCB
Metering:
Power quality metering with THD, TDD, voltage, current, power factor, harmonic waveforms and other features.
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-630/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
630/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
250A MCCB Feeder
250A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 250A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 250A MCCB
125A MCCB Feeder
125A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
63A MCCB Feeder
63A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 63A MCCB
63A MCCB with Contactor
63A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
63A 4P Power Contactor, AC1 Duty, Coil: 230V AC
24Hrs Time Switch, Aux. Supply: 230V AC
On/Off Push Button with NO/NC Elements
6A SP MCB 10KA
50KVAR APFC Section Incomer :-
63A 36KA TP MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links-3P (Set of 6 Nos) for 125A MCCB
5-Stage APFC Relay, Single CT Operated type
6A SP MCB 10KA, C-Curve
6A DP MCB 10KA, C-Curve
Exhaust Fan With Filter
Neutral Link
Outgoing:
15KVAR Capacitor Section
32A TP MCB 10KA, C-Curve
15KVAR Capacitor Duty Contactor, Coil: 230V AC
Add On Block (1NO+1NC)
15KVAR Capacitor Bank (440V),Cylindrical type
On/Off Push Button with 1NO/1NC Elements
Indicating Lamps - On/Off, LED
10KVAR Capacitor Section
25A TP MCB 10KA, C-Curve
10KVAR Capacitor Duty Contactor, Coil: 230V AC
Add On Block (1NO+1NC)
10KVAR Capacitor Bank (440V),Cylindrical type
On/Off Push Button with 1NO/1NC Elements
Indicating Lamps - On/Off, LED
5KVAR Capacitor Section
20A TP MCB 10KA, C-Curve
5KVAR Capacitor Duty Contactor, Coil: 230V AC
Add On Block (1NO+1NC)
5KVAR Capacitor Bank (440V),Cylindrical type
On/Off Push Button with 1NO/1NC Elements
Indicating Lamps - On/Off, LED
ii) Removal of Existing Panel : Sub : Substation I/C Panel(Sl.No.139)
iii) Sub : E-Type Panel (Outdoor)
Incomer:
400A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 400A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 400A MCCB
Metering:
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-400/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
400/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
250A MCCB Feeder
250A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 160A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 160A MCCB
125A MCCB Feeder
125A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
63A MCCB Feeder
63A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 63A MCCB
iv) Removal of Existing Panel : Sub : E-Type Panel (Outdoor)(Sl.NO.208)
v) Sub : C-Type Panel (Outdoor)
Incomer:
400A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 400A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 400A MCCB
Metering:
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-400/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
400/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
125A MCCB Feeder
125A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
63A MCCB Feeder
63A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 63A MCCB
vi) Removal of Existing Panel : Sub : C-Type Panel (Outdoor)(Sl.No.234)
vii) Sub : B-Type Panel (Outdoor)
Incomer:
125A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
Metering:
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-125/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
125/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
63A MCCB Feeder
63A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 63A MCCB
32A MCCB Feeder
32A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
viii) Removal of Existing Panel : Sub : B-Type Panel (Outdoor)(Sl.No.256)
ix) Sub : Scientist Hostel (Outdoor)
Incomer:
250A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 250A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 250A MCCB
Metering:
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-250/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
250/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
125A MCCB Feeder
125A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
32A MCCB Feeder
32A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
32A MCCB with Contactor
32A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
24Hrs Time Switch, Aux. Supply: 230V AC
On/Off Push Button with NO/NC Elements
6A SP MCB 10KA
16A MCCB Feeder
16A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 16A MCCB
x) Removal of Existing Panel : Sub : Scientist Hostel (Outdoor)(Sl.NO.277)
xi) Sub : Transit Facility (Outdoor)
Incomer:
250A 36KA 4P MCCB with Microprocessor Based Adjustable O/C, S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 250A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 250A MCCB
Metering:
0-500V Voltmeter Meter (96 x 96Sq.mm), CL:1.0
0-250/5A Ammeter Meter (96 x 96Sq.mm), CL:1.0
250/5A C.T's with 10-VA Burden, C.L-1.0
Indicating Lamps - R, Y & B Phases, 230V AC
6A SP MCB 10KA
Outgoing:
125A MCCB Feeder
125A 25KA 4P MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Spreader Terminal Links -4P( Set of 8 Nos) for 125A MCCB
32A MCCB Feeder
32A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
xii) Removal of Existing Panel : Sub : Transit Facility (Outdoor)(Sl.No.309)
xiii) Sub:- E-Type Meter Panel
Incoming :-
80A 25KA 4P MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 80A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A 4P RCCB 10KA, 100mA
3Ph Kwh Meter (10-60A)
32A TPN Terminal Block
xiv) Removal of Existing Panel :Sub :- E-Type Meter Panel (Sl.No.331)
xv) Sub:- D-Type Meter Panel
Incoming :-
63A 16KA DP MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 63A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xvi) Removal of Existing Panel : Sub:- D-Type Meter Panel (Sl.No.343)
xvii) Sub:- C-Type Meter Panel
Incoming :-
80A 16KA DP MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 80A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xviii) Removal of Existing Panel :Sub:- C-Type Meter Panel (Sl.No.355)
xix) Sub:- A1 to A6 & B1 to B2 Meter Panel
Incoming :-
125A 16KA DP MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 125A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xx) Removal of Existing Panel : Sub:- A1 to A6 & B1 to B2 Meter Panel(Sl.No.367)
xxi) Sub:- C7 to C12 Meter Panel
Incoming :-
80A 16KA DP MCCB with Thermal Magnetic Based Adjustable O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xxii) Removal of Existing Panel : Sub:- C7 to C12 Meter Panel (Sl.No.379)
xxiii) Sub:- B3 to B10 Meter Panel
Incoming :-
125A 16KA DP MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xxiv) Removal of the Existing Panel :Sub:- B3 to B10 Meter Panel (Sl.No.391)
xxv) Sub:- B11 to B18 Meter Panel
Incoming :-
125A 16KA DP MCCB with Thermal Magnetic Based Adjust- able O/C & S/C Protections (Ics=100%Icu)
Extended Rotary Operating Handle for 32A MCCB
Indicating Lamps - R, Y & B, 230V AC
6A SP MCB 10KA
Outgoing:
kWH Meter Feeder :-
40A DP RCCB 10KA, 30mA
1Ph Kwh Meter (10-40A)
32A TPN Terminal Block
xxvi) Removal of the Existing Panel : Sub:- B11 to B18 Meter Panel (Sl.No.403)
xxvii) Sub:- E1 Meter Panel
40A 4P RCCB 10KA, 100mA
3Ph Kwh Meter (10-60A)
40A TPN Terminal Block
xxviii) Removal of the Existing Panel :Sub:- E1 Meter Panel (Sl.No.415)
xxix) Sub:- E2 Meter Panel
40A 4P RCCB 10KA, 100mA
3Ph Kwh Meter (10-60A)
40A TPN Terminal Block
xxx) Removal of the Existing Panel :Sub:- E2 Meter Panel (Sl.No.421)
Credit ofr all the existing items (LT panels, fixtures, wiring, DBs etc.,) with quantity as above.
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
P L Raju Constructions Ltd
SREEKRISHNACONSTRUCTIONS
SAI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .