| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | ₹2.2 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹2.4 L+₹16,912.89 (7.59%)Rejected-Finance | ₹2.4 L+₹16,912.89 (7.59%) | L2 | Rejected-Finance L2 bidder |
| 3 | L3₹2.4 L+₹19,360.17 (8.68%)Rejected-Finance | ₹2.4 L+₹19,360.17 (8.68%) | L3 | Rejected-Finance L3 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Shortfall of documents |
Tender Value
₹2.4 L
EMD Value
₹4,846
Closing Date
30 Jun 2026, 1:00 pmClosed
AE, TESD, PWDte
AE, TESD, PWDte, Tamluk, Purba Medinipur
Renovation of EI work of NDPS Court at Tamluk District Court, Purba Medinipur.
2026_WBPWD_5015549_1
WBPWD/AE/TESD/e-NIT-01 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
Tamluk
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,846
6 Aug 2026
16 Jun 2026
2 Jul 2026
17 Jun 2026
30 Jun 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed](Average run 8 mtr) [PWD/GS, Item No. 5), Page No. E. 15] | 47 | Point | 1,022 | ₹48,034 |
| 2 | S&F 415 V, 16-32A per way, 4 way Horizontal TPN MCBDB with SS enclosure, double door with IP 42/43 protection concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment . (Make -legrand ) [PWD/GS Page No. D-10 Item No.: 4, D-6, Item No.: 7, D-5, It. No 6] Incoming - FP MCB Isolator 63A-1. Outgoing :10 A -32 A SPMCB-12 nos. | 1 | Each | 6,159 | ₹6,159 |
| 3 | Supplying and fixing double-door(2+8 way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - DPIsolator 32A -1, Outgoing 6 A -32 A SPMCB-8 nos (Make -Legrand ) [PWD/GS Page No.: D-9,6 Item No.: 13,7 ] | 3 | Each | 3,421 | ₹10,263 |
| 4 | Supplying & Fixing MS fan clam of two piece type for RC ceiling asper approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991) | 4 | Each | 249 | ₹996 |
| 5 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [PWD/GS Page: C-3 Item: 21/a] | 16 | Each | 68 | ₹1,088 |
| 6 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [PWD/GS Page: C-2 Item: 17] | 19 | Each | 205 | ₹3,895 |
| 7Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) | |||||
| 7.1 | Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification | 10 | Set | 621 | ₹6,210 |
| 7.2 | Twin fittings along with S/F of 2 no. 18-20 W LED lamps as per specification | 9 | Set | 989 | ₹8,901 |
| 8 | Dismaintaling the all old cables & all the old electrical line arrangement as per EIC. | 1 | Job | 1,500 | ₹1,500 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.54 MB
BOQ_5084404.xls
BOQ • 0.32 MB
2911.pdf
Tender Documents • 0.50 MB
Time_corrigendum.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .