Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹41.0 L+₹53,224 (1.31%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended being not enlisted in Category b (i) |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
24 Nov 2021, 6:00 pmClosed
MAJ JP SAHOO
GE 875 EWS, C/O 99 APO
SPECIAL REPAIRS/ REPLACEMENT OF T-5/ HPSV FITTING/ POST TOP LANTERNS WITH LED FITTINGS OF CERTAIN UNITS, SPECIAL REPAIRS TO LT PANELS AND CONNECTED ACCESSORIES OF MRS, PROVN OF ADDL LT STEEL TUBULAR POLE WITH SECURITY LIGHTS ALONG PERIMETER FENCE OF
2021_MES_484643_1
8653/T-53/E8
Open Tender
Miscellaneous Works
Item Rate
183 days
LIKABALI
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE 872 EWS
₹93,000
Yes
17 Dec 2021
28 Oct 2021
25 Nov 2021
28 Oct 2021
24 Nov 2021
12 Nov 2021
28 Oct 2021 - 3 Nov 2021
Amount
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any Size and any description including GI Pipes, Cable Protection Cover/ Bricks, etc. from Trenches, Floors, Poles, Walls or from any Situation, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Taking down Old Unserviceable Security / Street Light Fitting/ Flood Lights of any description from any Height, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole of Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified, applying Two Coats of Aluminium Paint over a Coat of Red Oxide Zinc Chrome Primer on Pole and 5 No. Band/ Strap with Black/ Yellow Colour Paint of 300mm Height from Top of PCC Copping/Block, Writing Number of Pole not less than 75mm Height, Embedded Portion of Pole Painting with One Coat of Black Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and Applying Two Coats of Aluminium Paint over a Coat of Red Oxide Zinc Chrome Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white, brown or green of Size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade, complete all as specified and as directed.
M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement/ as directed.
M&L Stay Assembly complete with all Accessories such as suitable Sise Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.4mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised Steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1800mm long and Galvanised Mild Steel Stay Plate of Size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Danger Notice Plate of size 25x20 Cm for LT, made of 1.6mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Clamps, Bolts & Nuts of appoved Size, complete all as specified and as directed.
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Pole Mounted Junction Box of Size 310x210x120mm, made out of Engineering Plastic One Piece Moulding suitable for Outdoor type, Heavy duty with IP66 Protection, having 4 No. insulated Alunminium Bus-bar of 60 Amp capacity with Metric Knockouts for Cable Entry and Aluminium Lugs of suitable Size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
S&F LED POST TOP Fitting 25 Watt (as approved), New Generation Energy Saving and Enviromental Friendly, Long Life, Electrically connected with and including suitable Size and Length PVC Flexible Twisted Copper Wire, 3 Core including Taking down Unserviceable Post Top Lantern of any description, complete all as specified and as directed.
M&L Street Light Fitting Bracket, made out from GI Pipe 40mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required Shape and Fixing with Electric Poles, etc. with and including Mild Steel Flat Iron 40x5mm Clamps of suitable Size with Mild Steel Bolts, Nuts & Washers, etc., applying Two coats of Aluminium Paint over a Coat of Red Oxide Zinc Chrome Primer to all Mild Steel Works including Taking down Unserviceable Street Light Fitting Bracket of any description from any Height, complete all as specified and as directed.
S&F LED Street Light Fitting 35 Watt (as approved), Energy Saving, Environmental Friendly, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LED as Lighting Source and Lens embedded PC Cover having IP65 Protection and Impact Resistance of IK07 with 10 KV Built-in Surge Protection Device, Electrically connected with and including suitable Size and Length PVC Flexible Twisted Copper Wire, 3 Core, complete all as specified and as directed.
S&F LED Street Light Fitting 45 Watt (as approved), New Generation, Energy Saving and Environmental Friendly, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LED as Lighting Source and Lens embedded PC Cover having TOP Opening, seperate Driver Compartment with IP66 Protection and Impact Resistance of IK07, electrically connected with and including suitable Size and Length PVC Flexible Twisted Copper Wire, 3 Core, complete all as specified and as directed
S&F LED Street Light Fitting 60 Watt (as approved), New Generation, Energy Saving and Environmental Friendly, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LED as Lighting Source and Lens embedded PC Cover having TOP Opening, seperate Driver Compartment with IP66 Protection and Impact Resistance of IK07, electrically connected with and including suitable Size and Length PVC Flexible Twisted Copper Wire, 3 Core, complete all as specified and as directed
S&F LED Flood Light Fitting 1x120 Watt (as approved), Energy Saving, Environmental Friendly, Long Life, Exclusive Innovative Die-cast Aluminium IP66 Protection, suitable for suitable for High Lighting Architectural Facade and General Purpose Lighting, electrically connected with and including suitable Size and Length PVC Flexible Twisted Copper Wire, 3 Core, complete all as specified and as directed
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 50 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Cable Protection Cover/ Bricks, GI Pipe, etc will be Measured and Paid separately under relevent Items
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 95 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Cable Protection Cover/ Bricks, GI Pipe, etc will be Measured and Paid separately under relevent Items
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 185 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Cable Protection Cover/ Bricks, GI Pipe, etc will be Measured and Paid separately under relevent Items
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 240 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Cable Protection Cover/ Bricks, GI Pipe, etc will be Measured and Paid separately under relevent Items
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 100mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L UG Cable Route Indicator, comprising of Mild Steel Round Bar 20mm dia as Leg 600mm long and welded to Mild Steel Plate 5.0mm thick of 100mm dia for Writing 1.1 KV LT UG Cable with Arrow Mark, embedding in and including Cement Concrete 1:2:4 (20mm graded Stone aggregate) Block of Size 300x300x400mm and grouting in Natural Ground along the Cable Route including necessary Earth Works (as per Site requirment), complete all as specified and as directed. NOTE : Cost of necessary Earthworks, Cement Concrete, Formworks, etc. will deem to be include in the Quoted Unit Rate.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I, Testing on Completion, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing (04 Set) of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Earth Strip of size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
S&F Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors in Ground including Taking down Old/ Unserviceable GI Strip of any description, complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
S&F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long Hexagonal Head Screws including Taking down Old/ Unserviceable Test Point Terminal Block of any description, complete all as per specified and as directed.
M/s HALDER ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .