Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
26 Mar 2024, 4:00 pmClosed
SE EWC Gorakhpur
Srirampuram Colony Mohaddipur Gorakhpur
33/11 S/S Railway ABT Meter Work
2024_PVVNV_919340_1
46/EWC(G)/2023-24
Open Tender
Electrical Works
Item Wise
30 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EWC Gorakhpur
₹12,000
Yes
1 Apr 2024
19 Mar 2024
27 Mar 2024
19 Mar 2024
26 Mar 2024
19 Mar 2024
Amount
Part - A Supply of Materials (Provided by Contractor)
33 KV PT ALP Structure
33 KV CT ALP Structure
conduit pipe
Top channel with clamp
M.S. Angle Iron 65x65x6mm bracing with clamps.
Aluminium Paint.
Bolts, Nuts & Washers.
Red Oxide Paint.
Stay Rod 20x1800mm
Stay clamp with nut & bolt
Stay wire 7/8 SWG
PG clamp for Dog
Armoured copper control cable 2 x 2.5 mm2
Armoured copper control cable 4 x 2.5 mm2
3X300 mm² XLPE C/J Kit Outdoor 33 KV
Part - B (Work) Shifting, Loading Carriage & Unloading of following materials from store centre Gorakhpur to work site
33 KV PT (0.2 acc.class)
33 KV C. T (0.2 acc.class)
S.T. Pole 9 M long.
ACSR Dog Conductor
33 KV VCB 800A, 750MVA
33 KV C.T 400/200/1A
Structure for C.T.
Structure for VCB
33 KV Line Isolator
Structure for LSI
33 KV Lightening Arrestor
33 KV Lightening Arrestor Structure
3x300 mm² XLPE Cable 33 KV
Erection of Double pole structure on 11 mtr ST Pole for 33 KV Line, including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth, proper ramming & fitting of all accessories (M.S. bracing angle iron with clamps, top channel 125 x 65 x 3200 mm with clamps, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing etc. complete work) .
Laying of 33 KV 3x300 mm² ‘XLPE’ cable(D/C) by digging pit & making trench in Proper size (1.2M depth x1.2M wide) below ground level by fixing bricks(4½˝) on both side of trench wall and 9˝ brick work at the centre of the trench along the cable. Fixing brick slab on top after filling sand around both the cable including cost of bricks and sand/ as per site requirement HDD mathod can be used.
Jointing charge of 33 KV ‘XLPE’ C/J Kit 3x300 mm² Outdoor
Laying of 33 KV ‘XLPE’ cable in air after providing 6” dia.M.S. pipe 3m long Complete work.
Special Pipe earthing for 33 KV Jointing Kit. (provided by contractor)
Special grouting and earthing for ALP structure.
Charges for making Plinth and foundation of VCB, CT and PT structure with earthing complete.
Painting of Structure complete
Installation of VCB, CT and PT, wiring and earthing complete work
Erection, grouting and earthing of LA & LSI structure.
Installation of LSI and LA and earthing complete work
laying control cable through conduit pipe by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying. (conduit pipe provided by contractor)
Jumpering of all related connection of with ACSR Dog coductor
Grouting of stay rods (20 x 1800) mm including all work of excavation, cement concrete in size (0.60 x 0.60 x 0.30) m in ratio 1:4:8 cement, sand, 40mm brick ballast) as per drg including back filling, proper ramming etc. Fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing.
M/s Electro Shine India
M/s S.B.S. Traders
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .