| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹17.7 L Quoted ₹19.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹22.9 LRejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹22.9 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹23.4 LRejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹23.4 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹35.4 LRejected-Finance HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | ₹35.4 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹37.1 LRejected-Finance SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | ₹37.1 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L1 | Shiv Enterprises L3 | M/S ADHIKARI CONSTRUCTION CO. L2 | S K ENGINEERS AND CONTRACTOR L4 | Haryana EngineerService L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out Complete all as specified and directed by Engr-in-Charge. | 105.8 | Cum | 70 ₹7,406 | 99 ₹10,474.20 | 99 ₹10,474.20 | 110 ₹11,638 | 99 ₹10,474.20 |
| 2.00 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed by Engr-in-Charge. | 61.23 | Cum | 20 ₹1,224.56 | 25 ₹1,530.70 | 19 ₹1,163.33 | 29 ₹1,775.61 | 9 ₹551.05 |
| 3.00 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. | 44.61 | Cum | 20 ₹892.24 | 25 ₹1,115.30 | 29 ₹1,293.75 | 39 ₹1,739.87 | 9 ₹401.51 |
| 4.00 | Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable all as specified and as directed.
Note : Compacted thickness of 18 cm of sand cushioning shall be considered for measurement and payment purpose. | 31.75 | Cum | 300 ₹9,525 | 300 ₹9,525 | 99 ₹3,143.25 | 390 ₹12,382.50 | 499 ₹15,843.25 |
| 5.00 | Supply and Laying precast concrete cover class HV type 1 flat size 300mm x180mm x40mm laid in trenches for cable protection complete all as specified and directed. | 2,175 | Each | 8 ₹17,400 | 8 ₹17,400 | 0.99 ₹2,153.25 | 14 ₹30,450 | 19 ₹41,325 |
| 6.00 | Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 core including taking out old u/s cable complete all as specified and as directed. | 325 | RM | 490 ₹1.6 L | 600 ₹1.9 L | 999 ₹3.2 L | 890 ₹2.9 L | 899 ₹2.9 L |
| 7.00 | Supply and laying in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm 3 core including taking out old u/s cable complete all as specified and as directed. | 165 | RM | 590 ₹97,350 | 800 ₹1.3 L | 1,199 ₹2.0 L | 899 ₹1.5 L | 1,099 ₹1.8 L |
| 8.00 | M&L for 80 mm GI tubing light grade galvanized with all fittings for protection to U/G cable along poles, walls, flows, road crossing including necessary cutting of road and making good in original surface where required incl taking down old u/s existing complete all as specified and as directed. | 60 | RM | 200 ₹12,000 | 150 ₹9,000 | 199 ₹11,940 | 490 ₹29,400 | 299 ₹17,940 |
| 9.00 | Supply & fixing or laying in replacement HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etc as reqd at site and as per direction of Engr-in-Charge. Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates. | 280 | RM | 60 ₹16,800 | 150 ₹42,000 | 299 ₹83,720 | 660 ₹1.8 L | 99 ₹27,720 |
| 10.00 | M&L for cable route indicator/ cable joint indicator solid block of size 75cmx30cmx10cm in arc shape at top above the ground level duly embossed words as per requirement including required necessary excavation , earth work, PCC complete all as specified and directed by Engineer-in-Charge. | 27 | Each Job | 200 ₹5,400 | 100 ₹2,700 | 99 ₹2,673 | 550 ₹14,850 | 399 ₹10,773 |
Updated dates
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
23 Dec 2025, 6:00 pmClosed
Col L Suvarna CWE
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
REPAIR/MAINT OF HT DISTRIBUTION NETWORK, ISOLATORS, 11 KV BUSBAR, PANEL, AVR AND OTHER CONNECTED WORKS AT AF STN FARIDABAD, MCC BASANT NAGAR AND AF STN NARAINA UNDER AOR OF GE (AF) FARIDABAD
2025_MES_741445_1
CWE/GGN/FT-45/2025-26
Open Tender
Electrical and Maintenance Works
180 days
AF Stn Faridabad
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Faridabad
₹76,000
Yes
2 Feb 2026
25 Nov 2025
25 Dec 2025
25 Nov 2025
23 Dec 2025
10 Dec 2025
25 Nov 2025 - 9 Dec 2025
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out Complete all as specified and directed by Engr-in-Charge.
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed by Engr-in-Charge.
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable all as specified and as directed. Note : Compacted thickness of 18 cm of sand cushioning shall be considered for measurement and payment purpose.
Supply and Laying precast concrete cover class HV type 1 flat size 300mm x180mm x40mm laid in trenches for cable protection complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 core including taking out old u/s cable complete all as specified and as directed.
Supply and laying in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm 3 core including taking out old u/s cable complete all as specified and as directed.
M&L for 80 mm GI tubing light grade galvanized with all fittings for protection to U/G cable along poles, walls, flows, road crossing including necessary cutting of road and making good in original surface where required incl taking down old u/s existing complete all as specified and as directed.
M&L for cable route indicator/ cable joint indicator solid block of size 75cmx30cmx10cm in arc shape at top above the ground level duly embossed words as per requirement including required necessary excavation , earth work, PCC complete all as specified and directed by Engineer-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm.
S&F in replacement HT bus bar insulator for HT panel suitable for existing VCB panel at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement spout suitable for exixting VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv housing ( Carrier) of Pole assembly suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of Pole assembly (Vacuum Bottle assembly) complete suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv Strip heaters 80-100 watt , AC 240 volts from HT panel of 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv thermostat from HT panel of 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv TNC switch suitable for Crompton greaves/Siemens VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv digital Ammeter suitable for Crompton greaves/Siemens VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv digital Volt Meter suitable for Crompton greaves/Siemens VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv digital trivector Meter suitable for Crompton greaves/Siemens VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv LED indicator lamp of different colours(red,green,yellow,white etc) suitable for Crompton greaves/Siemens VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of unsv door hinges and locking arrangement of VCB panel at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of Current transformer of ratio 200-100/5-5A, Burden 15 VA, Indoor Epoxy cast type, line voltage 11 kV, class 1.0/5P10, 50 Hz, size and model as suitable as existing CTs installed at 11 KV Substation suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
S&F in replacement of Potential transformer (Draw out type) of ratio 11kV/110V, Burden , 3- Phase, Rated voltage 11 kV, Insulation level, 28/75KV(P) class 1.0, 50 Hz, connection STAR / STAR , size and model as suitable as existing PTs installed at 11 KV Substation suitable for Crompton greaves VCB Incomer at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of shunt closing coil 24 V /110 V DC /AC suitable for exixting VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of Geared motor (EL) 220-250 V AC/DC suitable for exixting VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of tripping coil 24 V / 110 Volt DC/AC suitable for exixting VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of racking mechanism complete suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of tulip contact 08/12 fingers of circuit breaker suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of auxiliary switch with 24/36 pins incl all wiring with sockets suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of operating mechanism suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in replacement of motor cut off switch suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in repair PT Bushing of capacity 11KV suitable to fit on exisitng PTs suitable forexisting VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing in repair PT fuse of capacity 11 KV suitable to fit on exisitng PTs suitable for existing VCB at 11 KV substations complete as per direction of Engr-in-Charge.
Supply and fixing of combined over current and earth fault numerical relay with input current 1A/5A and auxiliary voltage 24 V incl complete installation in 11 kV VCB/RMU panel, complete connections and testing at 11 KV sub stations as per instruction from OEM all as specified and directed by Engr in Charge. Note: (i) Relay will be fixed in existing HT panel incl cutting , welding, drilling or any other suitable means or will be fixed in separate cabinet without any extra cost to department (ii) All type of wires required for proper connection will be provided by contractor without any extra cost to department. (iii) Proper functioning and testing will be carried out without any extra cost to department.
S&F in repairs of electromechanical type earth fault relay (inverse) type, CDG type with range 1.0 to 4.0 Amps in 7 steps suitable for protection/ tripping of HT 11 KV VCBs/OCBs Panel including carry out necessary modification in existing panel complete all as specified and directed by Engr-in-charge.
Supply and fixing of Master tripping relay of auxillery vaoltage 24 V/110V AC/DC incl complete installation in 11 kV VCB/RMU panel, complte connections and testing at 11 KV sub stations as per instruction from OEM all as specified and directed by Engr in Charge. Make: CG, ABB or Siemens. Note :(i) Relay will be fixed in existing HT panel incl cutting , welding, drilling or any other suitable means or will be fixed in separate cabinet without any extra cost to department (ii) All type of wires required for proper connection will be provided by contractor without any extra cost to department. (iii) Proper functioning and testing will be carried out without any extra cost to department.
Supply only Tinned copper fuse wire for HT supply from 8 SWG to 38 SWG all as per direction of Engr-in-Charge.
Supply only in replacement of Blue silica gel 4-6 mesh suitable for transformers breather and protect HT/LT panels from moisture as per site requirement complete, all as specified and as directed.
Material and Labour for preparing surfaces of transformer of capacity up to 250 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed by Engr-in-Charge. Note. (i) Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. (ii) MES No / SM No has to be written with 3" letters on each transformer after painting with white colour on black background without any extra cost.
Material and Labour for preparing surfaces of transformer of capacity 500KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed by Engr-in-Charge. Note. (i) Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. (ii) MES No / SM No has to be written with 3" letters on each transformer after painting with white colour on black background without any extra cost.
Material and Labour for heating, filtration and dehydration of transformer oil as per IS : 10028 (Part-III) 1981, Para 5.2 (obtained from transformer/ servo voltage stablizer with dehydration/ filtration plant to achieve dielectric strength of 40KV at 2.5 mm gap, complete all as specified and as directed by Engr-in-Charge. Note:- Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
Supply and pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified and as directed by Engr-in-Charge. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Repair maintainance of transformer of capacity upto to 250KVA by isolating ,disconnecting of input/output , supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
Repair maintainance of transformer of capacity upto to 250KVA to 400 KVA by isolating ,disconnecting of input/output , supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
Repair maintainance of transformer of capacity 500 KVA by isolating ,disconnecting of input/output , supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
Repair maintainance of transformer of capacity 125 KVA by isolating ,disconnecting of input/output , supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
Repair maintainance of transformer of capacity 630 KVA by isolating ,disconnecting of input/output , supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
Repairing/welding of leaking fins/body of transformer and making the same leak proof by proper welding all as directed by Engineer-in-Charge
Material and labour for checking the existing pressure of SF6 Gas in Gas Chamber of 11 KV , 630 Amps RMU , 2/3/4 way before filling and topping up the SF6 gas in the chamber of RMU including supervision of gas filling/topping up process and checking the pressure of gas after filling complete all as directed at site.
Supply and fixing in replacement for non-metal part HV bushing complete with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV)of capacity upto 250 KVA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA to 400 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 630 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement for non-metal part HV bushing with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA to 400 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA to 400 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 630 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 250 KVA to 400 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 630 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement top cover gasket of suitable size for outdoor/indoor/canopy type of transformer upto 250 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement top cover gasket of suitable size for outdoor/indoor/canopy type of transformer upto 630 KVA complete all as specified and as directed by Engr-in-Charge.
Supply only Synthetic gasket sheet for fixing top cover as per site requirement complete all as specified and as directed by Engr-in-Charge.
Supply only Tempertaure gauge 0-100 degree celcius suitable for distribution transformer 11/.433 KVA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 250 KVA complete all as per specification and direction of Engr-in-Charge.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 630 KVA complete all as per specification and direction of Engr-in-Charge.
M&L for Replacement of unserviceable oil level indicator, including replacing necessary nuts, bolts and gasket complete for transformer of capacity 400 KVA all as per existing and havig level marking 1/4, 1/2, 3/4 and full all as specified and directed
M&L for Replacement of unserviceable oil level indicator, including replacing necessary nuts, bolts and gasket complete for transformer of capacity 250 KVA all as per existing and havig level marking 1/4, 1/2, 3/4 and full all as specified and directed
M&L for Replacement of unserviceable oil level indicator, including replacing necessary nuts, bolts and gasket complete for transformer of capacity 500 KVA all as per existing and havig level marking 1/4, 1/2, 3/4 and full all as specified and directed
M&L for Replacement of unserviceable oil level indicator, including replacing necessary nuts, bolts and gasket complete for transformer of capacity 630 KVA all as per existing and havig level marking 1/4, 1/2, 3/4 and full all as specified and directed
M&L for Replacement of unserviceable oil level indicator, including replacing necessary nuts, bolts and gasket complete for transformer of capacity upto 125KVA all as per existing and havig level marking 1/4, 1/2, 3/4 and full all as specified and directed
M&L for Repair maintainance of oil cooled servo voltage stablizer of capacity upto 160 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
RC Network
Spring loaded finger
Microproccessor Based eletronic control board
M&L for Repair maintainance of oil cooled servo voltage stablizer of capacity upto 400 KVA to 630 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
RC Network
AC Synchronous Motor 10 Kg
Spring loaded finger
Microproccessor Based eletronic control board
Auto Transformer 150 Amp 3 Phase 630 KVA
M&L for Design ,development ,supply commisiong and testing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose T point terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043: 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test report Note :- 1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P 2. Min. resistance for earthing pit shall be less than 1 ohm. 3. Drilling or earth work shall be included in the overall cost quoted by the contractor.
Supply and fixing in replacement of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 32x6 mm copper strip complete all as directed by Engr-in-Charge.
S&F in replacement test point terminal block made of phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to copper strip bracket fixed to porcelain insulator in wall complete all as specified and directed
M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down old unsv GOD complete all as directed by Engr-in-Charge.
M&L danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled white with letters, figures , and conventional skull and bone in signal red colour and fixed with MS clamps bolts approved size for HT 25cm x 20 cm complete all as directed by Engr-in-Charge.
Supply, installing, testing and commissioning of air break gang operated triple switch (GOD) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 60 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed by Engr-in-Charge.
Supply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating incl complete connections in replacement complete all as specified directed.
M&L for Repair maintainance of Package type substation of transformer capcity 630 KVA by isolating , disconnecting of input/output ,supply cable,opening of top of transformer, detecting of fault , including relay setting ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required all as specified and directed. Note:- The replacement spare parts shall be measured and paid separately.
M&L in Replacement MCCB 250 Amp, 4 Pole, adjustable type, 16 KA including under voltage/ over volatge relay, adjustable overload setting and short circuit complete all as specified and directed.
Net Contract Sum will be after deducting Sch of Credit of Rs 1,25,613.50
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3506014)
Shiv Enterprises (BID ID -3499511)
S K ENGINEERS AND CONTRACTOR (BID ID -3499131)
Haryana EngineerService (BID ID -3498845)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_830239.xls
BOQ • 0.36 MB
TDFT45.pdf
Tender Documents • 1.32 MB
Download all tender documents and submit your bid