Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.5 CrAccepted-AOC 47 C MODEL TOWN EXTENSION LUDHIANA PB | LUDHIANA | PUNJAB | 141001 | ₹2.5 Cr | L-1 | Accepted-AOC accept |
| 2 | L-2₹2.7 Cr+₹19.8 L (8.07%)Rejected-AOC GIDDERBAHA PUNJAB | ₹2.7 Cr+₹19.8 L (8.07%) | L-2 | Rejected-AOC reject |
| 3 | L-3₹2.8 Cr+₹32.8 L (13.4%)Rejected-AOC ABOHAR | ₹2.8 Cr+₹32.8 L (13.4%) | L-3 | Rejected-AOC reject |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
10 Jan 2023, 5:00 pmClosed
Executive Engineer, Stage-II Division, Hoshiarpur
Executive Engineer, Stage-II Division, Hoshiarpur
Construction of Control Panel Room, RCC sump, and single family quarter, CT/PT room of Bhaddi lift Irrigation scheme off taking at R.D. 129000 m. L/S of Kandi Canal Stage-II
2022_WR_93815_2
04
Open Tender
Civil Works - Canal
Item Rate
120 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹4.4 L
Yes
12 Apr 2023
5 Jan 2023
11 Jan 2023
5 Jan 2023
10 Jan 2023
5 Jan 2023
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction including disposal of all surplus soil as directed with in a lead of 30 metres.
Earth filling under floor with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead up-to 1000 meters.
Cement Concrete 1:4:8 mixing by mechanical means using concrete mixer volumetric type.
Cement Concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type.
Damp proof course 4 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sq. m. laid hot and sanded.
20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per sq. m. laid hot and sanded.
Reinforced cement Concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in Super Structure.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluding steel reinforcement centering & shuttering in foundation and plinth.
Cement Concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure.
Providing & laying reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering & shuttering in super structure.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
10 mm thick cement plaster 1:3
12.5 mm thick cement plaster 1:3
12.5 mm thick cement plaster 1:5
Cementing pointing 1:2 flush on flat brick flooring
Conglomerate floor 50mm thick cement concrete 1:2:4. On 100 mm thick cement concrete 1:8:16 and 100 mm sand filling using mechanical mixer for mixing of material.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pilasters buttresses etc.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete.
Supplying pressed steel sheet frames (Chowkhats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Terracing consisting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm. top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing and cement pointing 1:2 flush on flat brick flooring.
Providing and fixing cast iron 100mm dia., rain water pipe with screw and wooden plugs fixed on wall-face, including filling joints with spun yarn and cement mortar 1:2 excluding head and shoe etc.
Providing and fixing cast iron head for rain water pipe on wooden plugs fixed on wall-face including filling the joints with spun yarn and cement mortar 1:2.
Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3.
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
White washing (Three coat)
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Glass strips ISI Marked Glass panes ISI Marked at site of work.4mm thick (10.75 kg/sqm)
RECESSED CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia. (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators (two module), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp. 16/20 Amp. Switches etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100 watts,Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-
i) Wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (two module).
ii) Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
iii) Wiring call-bell point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer & powder coated concealed metal box for electronic buzzer).
iv) Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade.
v) Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
vi) Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
vii) Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with double control switches.
(36) Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/14 S.W.G. (7/2.18mm dia.) G.I. wire in 20mm dia. G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 meter below ground level with necessary charcoal & salt mixture etc., up to 13 meter in length (including boring & refilling).
(37) Supply and Erection of earth rod 20 mm dia. for providing earth connections up-to line earth with G.I. Wire No. 8SWG. The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia. shall be drilled on the flattened side for facilitating connection with G.I. wire and thimble etc. The road shall be grouted up-to complete length vertically.
(38) Bonding to earth with G.I. wire No. 8S.W.G. (4mm dia.) in 20mm dia. heavy gauge (1.6 mm thick) welded conduit pipe (on surface) including painting etc.
(39) Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.
(i) Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.
(ii) Miniature circuit breaker double pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply.
(iii) Residual Current Circuit Breaker (RCCB for earth leakage protection) double pole 16/25amp., sensitivity 100mA (as per standard IEC 61008) suitable for 240/415 volts 50 cycles AC supply.
(40) Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
(i) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating FP/ TPN MCB's/ isolators for incoming and DP/ SP & N/ Single Pole MCB's/ RCBO/RCCB's for outgoing 6 way each.
(41) Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part III). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connection on both sides of switch with suitable size of Thimbles as per PWD General Specifications 2010.
(i) 63amp. 415 volts four Pole on load change over switch with advance neutral UNIT in sheet enclosure.
Any Other item
SURINDER SINGH CONTRACTOR
VARSHA CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .