Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.3 LAdmitted-Finance | -38.63% | ₹6.3 L | L1 | Admitted-Finance |
Tender Value
₹10.3 L
EMD Value
₹20,500
Closing Date
17 Aug 2026, 6:00 pmClosed
EE (ELECT-IV) JDA JAIPUR
EE (ELECT-IV) JDA JAIPUR
SITC of Pathway/Tree up lights at statue circle, JDA, Jaipur.
2026_JDAJP_584272_1
EE (ELECT-IV)/06/2026-27
Open Tender
Electrical Works
Percentage
30 days
JDA AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
ONLINE JDA WEBSITE
₹20,500
Yes
3 Sept 2026
8 Aug 2026
20 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 1.01 | 3 x 2.5 sq.mm | - | Mtr. | 188 | - |
| 2P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 2.01 | 50mm x 50mm x 6mm | - | Mtr. | 551 | - |
| 3Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 3.01 | Single pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
| 3.02 | 6A to 32A rating | - | Each | 187 | - |
| 3.03 | Four pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
| 3.04 | 50/63 A rating | - | Each | 1,745 | - |
| 4P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
06TDStatueCircle.pdf
Tender Documents • 10.69 MB
BOQ_1037675.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .