| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC MILITARY ENGINEER SERVICES GARRISON ENGINEER EAST JABALPUR 482 011 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.8 L+₹14,786.40 (0.45%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.0 L+₹3.3 L (9.99%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.2 L+₹5.5 L (16.8%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
17 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO JOINERY, CEILING, ROOF AND CERTAIN MISCELLANEOUS BR REPAIR WORKS IN THE MARRIED OTM ACCOMMODATION BUILDINGS IN THE AOR OF AGE BR MEG UNDER GE NORTH BANGALORE
2020_MES_388835_1
8479
Open Tender
Civil Works - Others
Item Rate
90 days
BANGALORE
Class D
Category a(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹60,000
Yes
26 Nov 2020
22 Oct 2020
19 Nov 2020
22 Oct 2020
17 Nov 2020
5 Nov 2020
23 Oct 2020 - 4 Nov 2020
60 days
Amount
Demolition of cement concrete (Reinforced) as in roofs, floors, beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key and disposing of debris off the premises complete all as specified and directed.
Dismantling of AC Sheets of any description as in roof covering including ridge, wind tie etc., complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles as in roofing complete all as specified and directed.
All as per Sl Item No. 1.005 above but portions bedded in cement mortar.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position in unframed work all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tiling fillets spaced at a distance exc. 15cm all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Rolled Mild steel work as in as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, and similar work conforming to Fe 410-W Gde E-250 all as specified and as directed.
Rolled Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter shunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvaniume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tenisile strenth of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
False ceiling with grid suspended system of size 600 x 600mm with standard sections consisting of main runner 29 x 24.7 x 0.8mm, cross tee 29 x 24.7 x 0.8mm and wall angle 22.2 x 22.2 x0.65mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (main runner, cross tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling including one coat of distemper complete and taking down old existing ceiling of any description complete all as specified and as directed. .
Brick work with sub class 'B' bricks built in CM(1:6), straight or curved on plan exc 6 mtr mean radius, using old size bricks complete all as specified and as directed.
All as per Sl Item No. 1.016 here in before but except bricks.
Plain Cement Concrete, type B0 (1:2:4) using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in chajjas etc complete all as specified and directed.
Reinforced Cement Concrete (nominal mix), type B-1, (1:2:4) using 20mm graded stone aggregate as in slabs supported on wall, beams and columns in floors roofs, landings, balconies, canpoies, deck slabs, shelves and the like complete all as specified and directed. NOTE:- Formwork and reinforcement shall be measured and paid separately under relevent items.
Form work to soffits of suspended slabs such as roof slab n.exc 200 mm thick (horizontal or sloping) complete all as specified and as directed.
TMT steel bars 8mm to 10mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM(1:4) finishing the surfaces even and fair mixed with approved water proofing compound complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Precast cement concrete louvers and jallies type C0, (1:3:6) using 12.5mm graded stone aggregate, 30mm thick (measured solid) set in cement mortar (1:4), including all mouldings etc., complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper over a coat of alkali reistant primer over two coats of wall care puttty on walls finished to smooth surfaces complete all as specified and directed.
Complete removal of existing treatment including preparation of old treated plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper over a coat of alkali reistant primer over two coats of wall care puttty on walls finished to smooth surfaces complete all as specified and directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Supply only approved integral liquid water proofing compound all as specified and as directed.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store all as directed.
20mm dia GI tubing medium grade with allfittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors complete all as specified and as directed.
Dismantling water tanks and cleaning for refixing / removal to store (exc. 250 and not exc. 500 ltr capacity) complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs capacity complete all as specified and as directed.
Fixing only Rotational moulded polythene water storage tank (cylindrical vertical with closed top) of any type , hoisted and fixed in position all as specified in SSR part I capacity of tank 500 ltrs capacity complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete including taking down old gate valve all as specified and as directed.
Taking down chowkat (without taking off shutter from the frame) area not exc. 1.5 sqm each including making good the disturbed surfaces in PCC (1:2:4) type B0 or CM (1:3) all as specified and directed
Box type Mild steel windows/ventilators double side shutters (windows side hung type, ventilators top hung type) pressed steel frames made out CRC Sheet of size 80x60x1.25mm double rebated shutters, box type made out of CRC Sheet of 40x20x1.0mm , windows & ventilator consisting of glass and gauge shutters fixed with box type hinges, aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, telescopic stays, etc complete all as specified including 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) All windows/ventilators design as per CECZ TD drg No 539. (ii) Steel frames, steel shutters and guard bars/grill shall be measured combindly for payment purpose, however unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,telescopic stays, locking arrangements (iv) Sheet glass and stainless steel wire mesh shall be measured and paid separately. (v) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose .
Stainless steel wire cloth 0.56mm nominal dia and average width of aperture 1.18mm and fixed with tinned tack or stainless steel wire staples complete all as specified and as directed.
Sheet glass 4mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane and all as specified.
Figured glass pin head type 4mm thick ordinary quality and glazing with oil putty/beading in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 10 mm thick and PCC 25mm thick and providing screed bed/rendering 10mm thick in CM (1:4) mixed with and including supply of approved liquid water proofing compound as per manufacturers instructions over and including 25mm thick (average) PCC 1:2:4 type B0 using 12.5mm graded stone aggregate by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing 50mm x 50mm coving at the corners with PMC mortar as above, and applying APP modified water prrofing membrane as per IS 1654-2017/IS 16352-2017 mineral finish, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
PRAGATHI BUILDERS
J PUSHPALATHA ENGINEER AND CONTRACTOR
D NAGI REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .