Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification of Cafeteria, at Naseem Bagh Campus
2021_UDJK_152940_1
F(UCD)(Elect. Cafet.S/F/T/C Link Sets )/KU/72/21
Open Tender
Electrical Works
Item Rate
30 days
Naseem Bagh Campus
As per NIT
8 documents required · 8 mandatory
₹100
Registrar University of Kashmir
Exempted
24 Dec 2021
13 Dec 2021
24 Dec 2021
13 Dec 2021
23 Dec 2021
13 Dec 2021
120 days
Amount
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch/modular socket or both, modular plate , suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description for the above mentioned items. Applicable Test Certificates have to be submitted following BIS Standards and ISI Marks wherever necessary (DSR 1.10.1) From switch board to primary light point & it's loop.
Wiring for heating point with 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 16A modular switch, 1 Nos. 16A modular socket, modular plate , suitable GI box and earthing the point with 4 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty/ISI Marked) Note : Rates of Suitable PVC conduit included in above description. Applicable Test Certificates have to be submitted following BIS Standards and ISI Marks wherever necessary. 2 nos Switch&Sockets will have one circuit but will be considered as 2 pts.
Wiring for computer point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 6A modular switch, 2 Nos. 6A modular socket, modular plate , suitable GI box and earthing the point with 2.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description.
Supplying and fixing 20 A, 240 V, Switch/Socket Combined outlet i/c suitable size GI Box, Modular Plates etc. complete for geysers, Applicable BIS Standards and ISI Marks wherever necessary
Circuit Wiring
Wiring for circuit wiring for Lighting/Exhaust/ Ceiling Fans alongwith earth wire with the following sizes of FRLS PVC ISO Certified having Acceptance Tests, Type Tests, Routine Tests, Optional Tests etc. insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required(light point/ fan point/ exhaust fan point/ call bell point) with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire i/c cost of conduit
Wiring for circuit wiring for AC Points alongwith earth wire with the following sizes of FRLS PVC ISO Certified having Acceptance Tests, Type Tests, Routine Tests, Optional Tests etc. insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required(light point/ fan point/ exhaust fan point/ call bell point) with 2 X 4 sq. mm + 1 X 4sq. mm earth wire i/c cost of conduit
Main LT Power Cable : Only XLPE insulated LT cables are to be used
Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) having ISO 9001/14001 marks 1100 Volt grade,3½ core/4 core ISI MARKED with Alu. Stranded /solid conductore.4 CORE ARMOURED 4 core X 50 mm2 Armoured XLPE Aluminum cable Main Cable
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground and refilling the trench etc as required
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required:4 X 50 sq. mm
(DSR 2.5.1 )Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) seperate for heating and lighting 8 way (4+24), TPN, vertical type, MCB DB, double door
Supplying and fixing 5 A to 32 A rating,Single Pole 240/415 V, 10 kA, "C" curve, miniature circuit breaker (Legrand, Hager, ABB,Eaton, Siemens make)suitable for inductive load ofin the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, 240V 10 kA, “C” curve, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. pertaining to IEC 60947-2 standards
Supplying and fixing 32A rating, 240V 10 kA, “C” curve, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. pertaining to IEC 60947-2 standards
Supplying and fixing 100A rating, 240V 16 kA, “C” curve, TPN thermal-magnetic release type MCCB suitable for inductive load of following poles in the existing TPN DB complete with connections, testing and commissioning etc. as required. pertaining to IEC 60947-2 standards, Thermal adjustable from 0.8 to 1 In
Supply, & Laying of 1 ¼ “ dia G I pipe at path/road crossing and at spots wherever required as per site requirement.
Providing and Fixing of 12 Watts LED Panel, round/square type, Slim type color temp: 6500K/4000K, Applicable BIS Standards, Surface/Recessed mounted as per site requirement .Certification: LM79-08, LM80, L70, NABL etc. certificates have to be submitted.
Providing and Fixing of 6 Watts LED Panel, round/square type,applicable BIS Standards color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement. Certification: LM79-08, LM80, L70, NABL etc. certificates have to be submitted
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.3 pin
SITC of approved make Exhaust Fan of 200 mm (8 Inches), plastic body with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
adil ashraf munshi
M/S BRIGHT SPARKS
stage.html
html • 0.02 MB
finance_338378.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .