Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.7 L+₹4.2 L (16.7%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.9 L+₹5.4 L (21.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite cat i.e b(ii) |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engr
HQ 134 Wks Engrs PIN-914134 C/o 56 APO
REPAIR/ MAINT OF 11 KV HT ELECT INSTALLATIONS INCL CONNECTED ITEMS SUCH AS TRANSFORMERS, HT SERVO STABILIZERS, VCBs, CT/PT/ GOD, DO FUSES, CONTROL CABLES ETC AT HAFT CHINAR AND TATTOO GROUND UNDER GE 970 EWS
2022_MES_554039_1
134 WE-47(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
9 documents required · 9 mandatory
₹500
GE 970 EWS
₹62,000
Yes
6 Dec 2022
23 Sept 2022
26 Oct 2022
24 Sept 2022
24 Oct 2022
9 Oct 2022
24 Sept 2022 - 1 Oct 2022
Amount
Excavation in trenches in hard/dense soil, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation of erection of poles, stays, laying of cables etc, complete all as specified and directed.
All as per Ser item No 1.00 above but depth exc 1.5m and not exc 3.0m.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 1.5 mtr above the starting point and deposting where directed at a level, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
M&L for sub class 'B' brick covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
M&L for replacement of 80mm bore GI tubing, light grade, laid in trenches, road crossing, cable protection or fixed to walls with clamps, complete all as specified and directed.
All as per Ser item No 7.00 above but 100mm bore pipe.
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, mass concrete etc including necessary form work, complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in coping etc including necessary form work, complete all as specified and directed.
M&L for 40mm graded coarse aggregate (broken stone or boulders), laying in sub - station yard, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping of pole etc including necessary formwork, complete all as specified and directed.
Dismantling old and unserviceable prestressed concrete / steel poles of any type including breaking cement concrete complete and S&F and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts, nuts and screws and specified type 410-SP-55 (11mtr long) in truly vertical position, 1.5 mtr length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, complete all as specified and directed. Note :- Earth work and PCC shall be measured and paid seperately under respective items of BOQ.
Dismantling of existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor all as specified and directed incl stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes, complete all as specified and directed.
S&F in repairs mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer after prepration the surface, complete all as specified and directed.
M&L for replacement stay assembly complete with 20mm dia stay rod with accessories shown in electric plate No 01 incl stay clamps and galvanised stay wire of size 7/4 mm, complete all as specified and directed. Note :- Loop insulator, stay wire, excavation and concrete work shall be measured and paid seperately under respective items of BOQ.
S&F in replacement disc type insulator, porcelain vitreous, brown or white, suitable for 11 KV HT working pressure of size 150mm height x 150mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous, brown of white insulator, suitable for 11 KV HT of working pressure of size 150mm height x100mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in repairs cable jointing kit for 11KV grade cable for outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
S&F in repairs cable jointing kit for 11KV grade cable for outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
S&F in repairs cable jointing kit for 11KV grade cable for indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
S&F in repairs cable jointing kit for 11KV grade cable for indoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
S&F in repairs cable jointing kit for 11KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
S&F in repairs cable jointing kit for 11KV grade cable for straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for size 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm, complete all as specified and directed. Make :- 3M/Birla/Denson
M&L for painting of VCB/ 11 KV AVR of any description with one coat of synthetic enamel paint of standard colour code by using spray gun over the existing painted surfaces after preparing the old painted surfaces, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core 95 sqmm, laid in trenches/ floor/ duct/ fixed on poles/ through GI tubing, complete all as specified and directed.
All as per Ser item No 26.00 above but cable size 3 core 120 sqmm, complete all as specified and directed.
Restringing only existing HT 11 KV OH line/ Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Note :- Restringing of each wire/span shall be measured as in RM.
S&F in replacement dropout (DO) fuse unit expulsion type, outdoor, three pole, 200 Amp suitable for HT 11 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse, complete all as specified and directed.
S&F in replacement incl testing and commissioning of (GOD) gang operated type air break isolating switch horizontal / vertical type mounting complete, double break and operation rod of suitable length 200 Amps capacity and suitable for 11 KV HT supply, complete all as specified and directed.
Removing of vegitation, grass, scrubs and bushes growing in sub station yard along with fencing by manually/mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Note :- (a) Unit rates quoted deemed to be included to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. (b) Neccesary tools shall be arrange by the contractor without any extra cost to Govt.
M&L for cutting and trimming of tree branches of girth 25mm to 75mm to 3mtr all around of any size, which is obstructing illumination of street light and touching LT/ HT over head line, by using required tools and plants including removing trimmed tree branches, complete all as specified and directed by Engineer-in-Charge. Note :- Each cleaning will be measured and paid.
S&F in replacement of synthetic insulating rubber mat, ISI Marked of size 1mtr x 2mtr x 2.5mm, suitable for 11 KV, complete all as specified and directed
S&F PVC sleeves, suitable for LT /HT ACSR conductor/ jumper in any type, in R Y B colours superior quality, inserted over the existing ACSR, complete all as specified and directed.
Taking down carefully existing 11KV / 433 Volts distribution transformer of capacity 25 KVA to 100 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations (as directed by Engineer-in-Charge) using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/existing position and re-commissioning the same, complete all as specified and directed. Note :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc. will be arranged by the contractor and rates for the same shall be deemed included in the quoted rates.
Taking down carefully existing 11KV / 433 Volts distribution transformer of capacity 160 KVA to 500 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations (as directed by Engineer-in-Charge) using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/existing position and re-commissioning the same, complete all as specified and directed. Note :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc. will be arranged by the contractor and rates for the same shall be deemed included in the quoted rates.
M&L for repair toTransformer step down 11KV / 0.433 KV of any type, of capacity 25 KVA to 100 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection/repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof type using spray gun, marking of MES/SM Number etc, replacement of conservator tank glass, reinstalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc., meggering the LT and HT side of the transformer and testing, complete all as specified and directed. Note :- Winding wire for making of coils and LT/HT bushes will be measured & paid seperately under respective item of BOQ.
M&L for repair toTransformer step down 11KV / 0.433 KV of any type, of capacity 160 KVA to 500 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection/repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof type using spray gun, marking of MES/SM Number etc, replacement of conservator tank glass, reinstalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc., meggering the LT and HT side of the transformer and testing, complete all as specified and directed. Note :- Winding wire for making of coils and LT/HT bushes will be measured & paid seperately under respective item of BOQ.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/ losses due to dehydration in distribution transformer for replacement complete including draining of old unservicable transformer oil, complete all as specified and directed. Make : Poweroil/Castrol/Pure lubes
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers/AVR/CT/PT units, complete all as specified and directed. Note :- The contractor shall be change the filter assy before starting the filtration of powe/ distribution transformer of any capacity in presence of Engineer-in-Charge.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 25 KVA to 63 KVA transformer, complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 1500 KVA transformer, complete all as specified and directed.
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 25 KVA to 500 KVA (Indoor/outdoor type), complete all as specified and directed.
M&L for earthing complete with GI earth plate of size 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc. and connected to earthing test point, complete all as specified, directed and testing after completion.
S&F in replacement off load tap changer for distribution transformer of any make and capacity from 100-500 KVA, complete all as specified and directed.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the LT transformer of any capacity and any make, complete all as specified and directed.
S&F in replacement of bush type insulator white/brown/green, working pressure 11000Volts HT side, complete all as specified and directed.
S&F in replacement of bush type insulator white/brown/green, working pressure 433 Volts LT side, complete all as specified and directed.
M&L for servicing of 11KV VCB / bus coupler by dismantling, cleaning, greasing the complete VCB with attached relays bus bar etc. insulation testing, setting the contact gap by measuring as required re-assembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed. Note :- New spares parts shall be measured and paid separately under respective items of BOQ.
M&L for carrying out primary & secondary injection test of 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed. Note :- PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid and considered as one unit.
Supply only the following spares for indoor VCB 11 KV 650 A 25 KA 350 MVA as approved by GE :-
Closing coil 24/30V DC.
Tripping coil 24/30V DC.
Antipumping device 24/30V DC.
Earth fault and over current relay, L&T any model (As reqd at site)
Digital/ Analogue type power factor indicator meter.
Digital/ Analogue type Voltmeter / Ammeter, 96mm x 96mm size.
LED type indicator lamp assembly.
Spout incoming side.
Spout outgoing side.
Gear system assy complete with handle for charging / discharging of VCBs.
Spring charging motor for VCBs.
Over current protection relay of ERL Model No 8431H32403 18-135V DC.
Metering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items.
Vaccum incapculated bottle
M/S Noor Mohammad Shalla
M/S YATTOO CONTRACTORS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .