| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹1.1 Cr | 1 | Accepted-AOC Being lowest and reasonable rates |
| 2 | 2₹1.1 Cr+₹2.5 L (2.39%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹1.1 Cr+₹2.5 L (2.39%) | 2 | Rejected-Finance Not being a lowest tenderer |
| 3 | 3₹1.1 Cr+₹7.0 L (6.65%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹1.1 Cr+₹7.0 L (6.65%) | 3 | Rejected-Finance Not being a lowest tenderer |
| 4 | 4₹1.2 Cr+₹12.0 L (11.4%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹1.2 Cr+₹12.0 L (11.4%) | 4 | Rejected-Finance Not being a lowest tenderer |
| 5 | 5₹1.3 Cr+₹21.4 L (20.2%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.3 Cr+₹21.4 L (20.2%) | 5 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
29 Dec 2022, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
SPECIAL REPAIR TO E/M WORK AND ALLIED WORKS AT SUBRAMANIAM LINE AND ME LINE (JCOs/OR MD ACCN) AND PROVISION OF TRANSFORMER, HT/LT CABLE, PANEL BOARD IN 15 GRENADIERS, 218 MED REGT, 147 FD WKSP, MOUDE LINE AND ASSOCIATED AREA UNDER GE(U) ELECT SUPPLY,
2022_MES_565553_1
CWE(U)/D-23/2022-23
Open Tender
Civil Works
Item Rate
180 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE(U) ELECT SUPPLY
₹1.8 L
Yes
21 Jan 2023
26 Nov 2022
31 Dec 2022
26 Nov 2022
29 Dec 2022
17 Dec 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface & sides to required slope/size as directed by the Engineer-in-Charge
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by the Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & Labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc including punning down of sand layer all as specified and directed.
Supply & Fixing sub class B bricks of size 230mmx115mmx75mm having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Supply & laying non-reinforced precast concrete cable (PCC) cover class HV type 1 with peak size 300 mm x 180mm x 40mm in trenches for protection to under ground cable complete all as specified.
Material & Labour for HDPE pipe suitable for 5 kgf/cm 2 working pressurewith all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed of following sizes
50 mm dia
110 mm dia
Boring holes of 110mm dia, 2 meter deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 100meters complete
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
185 Sqmm x 3.5 core
150 Sqmm x 3.5 core
120 Sqmm x 3.5 core
35 Sqmm x 3.5 core
50 Sqmm x 3.5 core
630 Sqmm single core
25 Sqmm x 4 core
16 Sqmm x 4 core
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed. Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
95 sqmm 3 core
120 sqmm 3 core
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 120 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 to 120 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed.
Supply, installing, testing and commissioning of outdoor type plinth mounted step down transformer, 11 KV/433 Volts (at no load), Level -II, AC 3 phase 50 Hz, 500 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014 and shall comprise of the following :-
(a) One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 core 120 Sq mm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Airrelease valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 32 x 6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Unidirectional roller wheel. (n) Other accessories as per manufacturer design. (o) Oil temperature indicator, winding temperature indicator, marshling box single window, double flit buchhloz relay with alarm and trip contact. NOTE : Transformer shall be supplied inclusive of initial oil filling to appropriate level of insulation oil with desired dielectric strength. Cost of Provn of plinth for transformer as per OEM drawing shall be deemed to be included in the cost inserted by the bidders
Material & Labour for plate Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level with alternate layer of common salf and charcoal dust mixed & packed 150 mm thick homogeneous layer all around the GI earth plate and connected to galvanized earth strip 32 x 6 mm up to 7.5 Mtr by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate No 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode 20 mm dia pipe for watering all as specified.
Material & Labour for perimeter fencing of size ( LxWxH) 8m x 5m x 2m (as per site condition) having angle iron post 2 m height for parameter fencing of Transformer / Sub stn including chain link fencing fixed to angle iron/pipe including excavation , earth work , brick work , surface excavation and PCC 1:2:4 type B-1 and Necessary steel gate of angle iron of size 75mm x 75mm x 5mm of size 01 m x 2 m including locking arrengment having square bar of size 25mm x 25mm x 3mm including two coat of synthetic enamel paint over a coat of red oxide primer to all steel surfaces complete all as directed .
Supply errection in position & fixing of complete lighiting system using raising and lowering type of high mast tower of 16 Mtr conforming to IS 875 Part III 1987 and suitable for 180 KM/hour wind speed for mounting lantern ring suitable for fixing of 120 watts LED fiood lights fittings 09 Nos(symmetrically fitted, including wiring from ground level to top of the mast, the mast should be motor operated for up and down, double drum carriage, double drum winch 6 mm 316 grade SS having rope of 7/19 with central core SS, construction trailing cable 3 core x 2.5 sqmm 1 No per mast up to heigh, foundation nut and bolt of suitable size hot dipped galvanised from special steel along with nuts and washers, anchor plates and template & circuit wiring with 10 sqmm copper wire, and power tool control, including RCC foundation as per manufacturers design and drawing complete all as specified & directed. NOTE :- The cost of excavation, earth work and PCC for foundation of high Mast is deemed to included in the quoted rate.
Supply & installing prestressed concrete poles (9 mtr long) 102mm x 172mm at top and 102mm x 279mm at bottom (class 10) complete all as per manufacturer's instructions and as specified and as directed by E-in-charge.
Supply and fixing in replacement of Energy saving, environmental friendly, long life, LED street light made up of pressure dia cast aluminium housing with high efficient lighting source with toughened glass having IP66 protection LED street light of capacity 70 Watt complete all as specified.
Supply and fixing Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 LED flood light suitable for high lighiting architectural façade and general purpose lighiting of capacity 120 Watt LED complete all as specified.
Supply & Fixing of street light bracket made out of 32 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 25mm x 5mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/wall complete all as specified and as directed.
Supply & Fixing KIOSK box weather proof made out of PVC, one piece moulded SMC base and out door pole mounted hinged door size 333mm x 233mm x 120 mm out side and 300mm x 200mm x 105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp MCB SP with base for controlling the street light, FI clamps 30mm x 4mm with necessary MS nuts bolts and washers including embossing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed by Engineer-in-Charge.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Supply in fixing automatic light timer switch with nature switch Cat No SWADEEP-03EC12KW3P-DUEL, infra ray sensor with pre down switching off timer 4-8 hrs of maximum load capacity of KW per phase. Degree of protection conforms to IP 65 complete all as specified.
Dismantling of MS channel or Angle iron or flat iron sections from LT poles complete all as specified.
Dismantling of insulators of any type and any size from RCC/PCC poles complete all as specified.
Dismantling carefully Old unserviceble ACSR conductor / jumper from LT Pole complete all as specified.
Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of any size from LT Pole to MCB DB complete all as specified.
Supply, installation, testing and commissioning of transformer step down ,outdoor type double wound core type copper wound 11/.433KV Level-II, 3 phase ,50 Hz AC of rating 250 KVA oil immersed, naturally air, oil natural air natural(ONAN) with external cooling tubes, transformer delta connection on primary side(HV) and star connected on secondary side (LV) in accordance with vector symbol DYn-11 (vector group 4) with neutral brought out on secondary side (LV) with earthing and having tapping range on HV side for constant out put so as to alter/vary secondary voltage by + 7.5% in eaual steps of 2.5% changed by means of manualy operated "Off Load" taps changing gear. The maximum trmperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in V/LV winding when measured by resistance method after continuous full load run on an ambient temp of 45 degree celsius transformer shall be Boltless CORE DESIGN .Transformer shall be double wound core type with low loss ,non ageing ,high permeability prime grade CRGO with m4 grade or better ,perfectly insulated and clamped to minimize nosie and vibrations .The transformer shall be IS/IEC 60076 AS per IS-1180 PART -I OF 2014 marked and shall comprise of the following . (a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level guage.
(b) Silicagel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservatore air tank (pressure release valve). (d) Air release valve plug. (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with copper rodscompelete with nuts and washer ,with cable glands suitable for reception/taking out 3.5 core 400 sqmm LT 1100 volts grade ,XLPE insulated and pvc sheathed heavy duty armoured cables including jointing materials complete (f) Explosive vent. (g) 01 No 100 mm dial type thermometer vapour pressure type having rnage 0-120 degree centigrade with max temp indicator and resetting device incl, max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers. (k) Two Nos earthing terminals marking plate. (l) Rating plate and terminal marking plate (m) Extra bushing for neutral outside the cable box brought on LV side.
(n) First filling of new and unused transformer oil conforming to IS-335 of 1986 marked filtered and tested upto 50 kv dielectric strength at 2.5 mm air gap between testing electrodes ,specific resisatance at 27 degree celsius ohm-om 500 x 10 the 12 ,water content 50 ppm , dielectric disspiation factor (tan Delta at 90 degree celsius ) 0.005 neutralised value mg of KOH/gm of oil 0.03 ,inter facial tension N/M at 27 degree celsius 0.04 ,flash point 140 degree celsius and sluge 0.1% by weight and tested upto 60 KV dielectric strength. (o) Lifting lugs (p) Oil drain valve with plug. (q) One cable box on HV side (Primary) consisting of three nos porcelain bushing with copper rods ,compelete with nuts and washer ,with cable glands suitable for reception/taking out 3 core 150 sqmm HT 11000 volts grade ,XLPE insulated and pvc sheathed heavy duty armoured cables including jointing materials complete (r) Dehydrating breather with first filling of dehydrating agent. (s) Two earthing terminal on tank body to facilitate fixing of 32mm x 6mm GI Strip.
(t) Rating plate with terminal marking plate. (u) Inspection cover. (v) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (w) Hand hole of sufficient size to access interior of tank. Transformer losses shall not exceed the loss mentioned in table 6 of IS :1180 OF 2014 part -I with latest energy Effeciency level -II Note :- (i) The contractor shall arrange factory visit for the EIC or his rep for testing of transformer before despatch. (iii) Any other parts/items not specified above but have been considered essential for smooth and safe functioning shall be included in the items and are covered against the quoted rate.
Supplying, installation, testing and commissioning of 11 KV 630 Amps having short circuit capacity 21 KA for 3 sec, Outdoor (IP54), RMU (Ring main unit) 5 way comprising of 02 Nos motorized operated load breaker and 03 No 630 Amps fixed type motorized spring charging VCB electrolytic grade copper bus bars all inside single, gas filled, robotic welded non-magnetic stainless steel 304 or better grade, IP 67 Degree of Protection tank with min thickness 2.5 mm +/- 0.1mm, min thickness for load bearing/outer sheet 2 mm and 1.6 mm for non-load bearing member, internal arc IAC AFLR classification, 21 KA for 1 sec for gas tank and Cable chambers. The enclosure shall have pad lockable doors as per OEM design, fully covering the front facia and cable boxes, ensure fail safe anti-theft protection. The unit along with Bus connected, fixed type Auxiliary transformer shall include the following along with all necessary accessories and fittings are required at site:- (A) Incoming Load Break Module - Each consisting of following accessories: (i) Each switching – unit is designed as a three position switch. This three function switch combines the function of switch – disconnector an earthing switch
(ii) 11 KV, 630 A Load Breaker Switch with interlocking line -earthing scheme both short circuit current, 21 KA for 3 Sec Making capacity – 50 kAp- 01 No (iii) Auxiliary contacts – 1 NO + 1 NC- 01 No. (iv) Spring assisted motorized mechanism with un-inhabited operating shaft for emergency manual operation with integrated earthing switch – 01 No (v) Cable terminals cable bushing situated not beyond 185 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access of size upto 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination/End Kits Each set of 3 (vi) Right angle boots (push on type) Each set of 3 (vii) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No. (viii) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set (ix) Fault passage indicator – It is to be provided for each incomer Load break unit, FPI with LED / digital display to be added to detection of cable fault – 01 No (x) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No Cable cover standard - 01.
(B) Outgoing VCB Module - Each consisting of following accessories: - (i) Each function – unit consists of a vacuum – circuit breaker in combination with a three position – switch. The three-position switch fulfils the operation of the disconnector and earthing function. (ii) 11 KV, 630 Amps Fixed type VCB module with series disconnector cum earthing switch of short circuit breaking current / withstand, 21 KA for 3 Sec Making Capacity – 50 kAp - 01 No (iii) Auxiliary contacts – 1 NO + 1 NC- 01 No. (iv) Stored – energy motorized high – endurance spring charging mechanism (M1+), with inbuilt spring charging lever and mechanically latched ON/OFF push -buttons to allow handle less and un-inhabited operation – 01 No. (v) Cable terminals cable bushing situated not beyond 185 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access up to 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination Each set of 3 (vi) Right angle boots (push on type) Each set of 3
(vii) 3 O/C + 1 E/F self-powered numerical protection relay with low and high set for over current and Earth Fault. Relay should have facilities to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol – 01 No/per VCB outgoing. (viii) Auxiliary Relay for OTI / WTI – transformer protection – 01 No(ix) Associated ring Core cast- resin insulated CTs Dual Ratio 100/50/1-1 or 81/40/1-1 or 50-25/1-1 Amp as per site reqmt (for metering and protection) 2.5 VA, 10 P 10 Protection – Each set of 3 (x) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No. (xi) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set (xii) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No (xiii) Emergency trip push button – 01 No. (xiv) CB mechanical operation should be min 10000 Nos without any maintenance. (xv) Vacuum Interrupter and VCB must be RMU manufacturer’s own make for better life cycle optimization.
(C) Bus connected, fixed type Potential and Auxiliary transformer with floor mounted compartment of matching height and depth, positioned alongside RMU to provide required aux. supply for spring charging motor and metering, consisting of following accessories:- (i) 1-Ph 11 KV/110V, class 0.5 potential transformer – 03 Nos for metering. (ii) 1-Ph (11 KV/rt3), 230 VAC, 250/500 VA Auxiliary transformer – 01 No for battery charging. (iii) 11 KV Tri vector Energy Meter of Class 0.5 accuracy with RS 485 Communication – 01 No per VCB o/g (iv) 2x12 Volt DC battery – 01 Set (v) 230 VAC/24 VDC Battery charger – 01 No, with indication of status of functioning (vi) HRC fuse links for primary side isolation and AC/DC MCBs for secondary isolation – 01 Set (vii) Voltmeter & RYB LED indications to confirm AC/DC supply availability – 01 Set (viii) Anti condensation space heater with thermostat – 01 No (ix) LED lamp for illumination and 3 pin socket with switch – 01 No
(D) Standard mano meter -01 for each tank, Operating handle - 02, cable clamping provision (standard)-01/for every cable entry, Operation and maintenance manual - 01, installation and commissioning manual - 01, RMU Foundation as per OEM Recommendation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 mtrs from ground level. NOTE:- The above module consisting of Load break Switches and VCBs shall be aligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms cost of provision of plinth for RMU as per OEM drawing shall be deemed to be included in the cost inserted by the bidders.
Material & Labour for construction of Brick Masonry ( Using sub class 'B' Brick) platform of size 2m x 2m x 1 m hight consist of following specification. (i) Necessary excavation and earthwork shall be in soft/loose soil complete all as specified. (ii)100mm thick 60cm wide PCC 1:4:8 type D2 lean concrete in foundation. (iii) 2 Brick thick Brick Masonry in CM (1:4) of 0.90m height above the ground level and 0.6m below the ground level shall be provided. (iv) 15mm thick cement plaster in CM(1:6) on external surface of the brickwork shall be provided. (v) Necessary earthfilling as required shall be carried out. (vi)100mm thick RCC (1:2:4) type B1 reinforced with 10mm dia TMT bars @ 200mmc/c bothways on brickwall/compacted earthfilling shall be provided. (vii)02 Nos ISMC-100,each 2.00 m long shall be embedded in RCC for balancing of transformer. (viii) One brick step 75cm long in CM(1:4) shall be provided.all as specified and directed .
Supply & Fixing cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enemel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item.
Supply & Fixing in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
Supply & Fixing in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed.
Material & Labour Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed .
Material & Labour Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete as specified and directed.
Material & Labour for Demolation of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed.
Material & Labour for providing for road path, drain of cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 50 mm Thick complete all as specified and as directed.
Supply & Labour for cement concrete type B-2, 1:2:4, 75 mm thick (using 40 mm gradded aggregate) for floors and paving etc complete all as specified and directed.
Supply & Fixing equal Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
Material and labour plain cement concrete 1:3:6 mix, type C2 using 40mm graded stone aggregate as in foundations all as specified and directed.
Material and labour plain cement concrete 1:2:4 mix, type B1 using 20mm graded stone aggregate as in coping including necessary form work, exposed surface of concrete shall be finished even and smooth without using extra cement
Supply & Fixing 4 mm thick mild steel wire 50mm x25mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid including one coat of primer and two coat ot synthetic enamel paint complete all as specified and directed.
Material & Labour for 2 coat of synthetic enamel painting over a coat of red oxide to steel surfaces including preparation of newly surface complete all as specified.
Vijay Electricals
mayur enterprises
Ridhi engineers and builders
Leo Network power systems
kailu construction co
Powerlite Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .