| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.8 L+₹22,534.50 (0.52%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹47.7 L+₹4.1 L (9.38%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L3 | Rejected-Finance L3 |
Tender Value
₹49.3 L
EMD Value
₹98,640
Closing Date
22 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SPL REPAIR TO BLDG No P 123 (QTR 01 TO 08) ORs MD ACCN AT DERA BABA NANAK VIHAR OF 11 CORPS ZONE WKSP AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2025_MES_702373_1
GE/JULL/ET-81/2024-25
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹98,640
2 Jun 2025
24 Mar 2025
29 Apr 2025
24 Mar 2025
22 Apr 2025
8 Apr 2025
Amount
Demolition of cement concrete of any description and in any position (as in sunken portion also) and removing surplus spoil out of defence land where directed at a level not exc 1.5 m above the starting point all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified
M&L for 50mm PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth without using extra cement all as specified
M &L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (i) Application of Two component acrylic modified cementitious coating (aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture's published literature should be strictly complied with, including but not limited to the following:- (bb) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required.
(cc) Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO. (dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions. (ee) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet. (ff) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area. (gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (hh) The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces. (jj) It is essential to cure Acrylic modified cementitious coating immediately after application (minimum 6-8hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking.
(kk) A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645. (ll) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP. (mm) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations. (nn) Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer's and approved by GE.
(ii) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealent. (iii) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min 15cm) all around. (iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified.(Paid Seperately) (v) Providing drainage spout pipe GI pipe 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long ) including cutting to existing wall and making good the disturbed surface complete all as specified and directed. (vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified. Note:-Item No 25 (iv) ,(v) &(vi) shall be measured and paid seprately.
M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded brick aggregate) as in sunken flooring complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub floor,sub base ,concrete surface finished surface even & rough to receive topping floor/tiles finish/layer complete all as specified and directed
M&L for non skid ceramic coloured tiles (premium quality) 7 to 8 mm thick area of tiles exc 0.6 sqm but n exc 0.11 sqm of each tiles in floor set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & including screed bed or beading layer of morter 15mm thick in cement morter (1:6) for laying floor finishes , complete all as specified and directed. Make:- Kajaria/Somany/Johnson
All as per item No 07 above but on skirting etc over and including 10 mm thick cement plaster finished even and rough to receive tiles in Cement mortar (1:4) complete all as specified.
M&L for coloured glazed tiles (Premium quality) of size 450x300x7mm thick as in vertical surface i.e. skirting/dado set and jointing in neat cement slury and pointed in white or coloured cement to match the existing surface with & including rendering 10mm thick in cement morter 1:4 finished rough to fix tiles , complete all as specified and directed . Make:- Kajaria/Somany/Johnson
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc
M&L for non skid ceramic coloured tiles (premium quality) of area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm and 6-7 mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. Make:- Kajaria/Somany/Johnson
Ditto all as per item No 11 above but on vertical surfaces such as riser, skirting, dudo, etc over and incl 10mm thick cement plaster in CM 1:4 rough finisher surface to receive tiles
M&L for 20 to 25mm thick machine cut kota stone slab in single peice size in treader & landings of stair cases including rounding to edge,over including brushing neat cement slurry with 3 kg/sqm with pigments to match the shade of slab including cutting, rubbing and mirror/granite finish polished, complete all as specified and directed.
Ditto all as per item No 13 above but on vertical surfaces such as riser, skirting, dudo, etc over and incl 10mm thick cement plaster in CM 1:4 rough finisher surface to receive tiles
Demolition and dismantling of reinforced cement concrete of any description and in postiion not other wise specifically provided for.
M&L for MS TMT bars 10 mm dia and over dia and cut to lenth, bent to shape required incl cranking bending spirally for hooping for column hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia.
M&L for reinforcement cement concreteType B0 1:2:4 (12.5mm graded aggregate) as in slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including form work bottom and sides and the like, complete all as specified
M&L for 15/16 mm thick machine cut green udaipur stone jointed with neat cement slurry mixed with pigment to match the colour of stone incl cutting and polishing and making hole in stone and RCC shelves suitable for gas pipe, with round edges where required and incl 15 mm screed bed with cement mortar 1:6 including dismantling of old stone/ tiles all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 mm above the starting point complete all as specified
M&L 15 mm thick cement plaster in cement mortar 1:6 on internal surface of brick or concrete surface finished even and smooth without using extra cement all as specified
M&L 15mm thick cement plaster in cement mortar 1:4 Mixed with integral water proofing compound in propotion recommended by manufacturer on external surface brick or concrete surface finished even and smooth without using extra cement all as specified (WPC shall be measured and paid separately)
M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified
"Supply only" integral water proofing compound (ISI Marked)
M&L precast ferro cement shelves 25mm thick fixed over angle iron 25x25x5mm frame fixed to wall and necessary groves cutting to wall and making good by cement plaster (1:1) to match the surfaces, including necessary form work and reinforcement etc complete work for shelves, platform , cub board shelves etc all as specified and directed.
S&F in repairs Vitreous china wash down water closet pan (padestal pattern), white (excluding fixing bolts,flushing cistern) incl seat cover and flushung pipe for pedestal pipe etc. Make:- Hindware/Parryware/Cera
S&F chromium plated brass JET including PVC pipe connection fixed to EWC all as specified and directed.
Dismantling and breaking up drain pipe CI/AC/PVC salt glazed ware or reinforcement concrete pipe in event not exceed 150mm dia including all fitting
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per item ser No 28 but 75 mm dia complete
S&F PVC (SWR) bends 110 mm with access door complete all as specified and directed.
All as per item ser No 30 but 75 mm with access door
S&F for 110mm PVC (SWR) vent cowl complete all as specified and directed.
M&L PVC floor trap 75mm dia with grating including jointing to waste pipe fixed in cement contrete type B-1 (1:2:4)
S&F 150 mm dia PVC gully traps setting and jointing with lead joint all as specified and directed
S&F CP grating 125mm dia all as specified and directed by Engr-in-Charge
Taking up of or down steel tubing and connections 15mm bore complete all as specified and directed .
All as per ser item No 36 here in before, but 20mm bore
S&F steel water tubing (ISI Marked) 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc complete all as specified
S&F steel water tubing (ISI Marked) 20 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing complete all as specified
S&F PVC valveless, syphonic action type flushing cistern low level white with inlet ball valve float and handle, 10 ltr capacity including brakets fixed in repairs. Make:- Parryware/Hindware/Cera
S&F Vitreous china wash hand basin , white, flat back 550x400mm including one number brass CP waste coupling ,32mm dia , Pvc waste pipe with connector , brackets 2 nos including cutting for and pinning in ends of brackets complete all as specified. Make:- Parryware/Hindware/Cera
S&F Pillar tap ,brass with capston head , fancy type chromium plated , screwed down high pressure with or without lettered 'Hot' or cold with long screwed for 15mm bore iron pipe and fixed complete all as specified & directed. Make:- Jaguar/Cera/ESS-ESS
S&F PVC connection , reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete
S&F 15mm stop valves, fancy type chromium plated with long shank and cup (conceeled type) screwed down, high pressure with crutch or butter fly handle screwed at two right angles ends for both iron pipe or for unions
S&F 15mm Angle/stop valves, fancy type chromium plated with long shank and cup screwed down, high pressure with crutch or butter fly handle screwed at two right angles ends for both iron pipe or for unions and fixed in repairs. Make:- Jaguar/Cera/ESS-ESS
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen with plugs, washers and waste coupling and waste pipe over all size 915 mm x 460 mm bowl size 410 mm x 330 x 160 mm including bedding in CM on dwarf wall or incl fitting contilever brackets and conection union to pipe. Make:- Nirali/Jayna/Blue Star
S&F Bib tap , chromium plated suitable for 15mm bore iron pipe with long body fancy type complete fixed in repairs. Make:-Cera,Jaguar, ESS-ESS
S&F brass chromium plated shower rose of 125mm size, with or without swivel joints including fixing to steel pipe or union in repairs Make:-Jaguar/Cera/ESS-ESS
S&F brass chromium plated tubular towel rail 20 mm dia , D type 60 cm long between CP flanges all as specified. Make:- Jaguar/Cera
S&F for Stainless steel plate rack of superior quality size 33" x 36" x10" and not less than 8 kg all as specified and directed. Make:- Nirali/Jayna/Blue Star
S&F Acrylic corner set of 3 pieces as per sample approved by Engr -in-charge all as specifed and directed
S&F Acraylic WHB Shelf 600 mm long and 125 mm wide as per sample approved by Engr -in-charge complete all as specifed and directed fixed in repair
M&L for mild steel pipe 25 mm dia curtain road with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade as approved by GE all as specified. Fixed in repair
S & F 20mm dia curtain rails , mild steel , chromium plated fixing in cup board with brackets, stops, rollers etc, all as specified
Taking down chowkats or frame not exc. 1.5 sq m each with shutters (without taking off shutters from the fames)
Taking down chowkats or frame exc. 1.5 sq m but n.exc 4 sq m each with shutters (without taking off shutters from the fames)
M&L for MS work as in hold fast and similar small articles complete all as specified.
M&L for pressed steel frame of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges,lock strike plate etc complete all as specified and directed
M&L for pressed steel frame of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges,lock strike plate etc complete all as specified and directed
S&F structural steel framed work as in doors frame or gates of angle or other section with gusset plates, rails, braces etc. Cutting, drilling and welding complete, drilled for fixing of steel sheeting or other covering. Doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete all as specified and directed.
S&F Flush shutters 40 mm thick , Solid core construction, with block board core and plywood face panels, commercial type on both sides with decorative face veneer on one Side, complete all as specified and directed
S&F 35mm thick IInd class hard wood plain framed factory made, panelled shutter with (2 panel) of 9 mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F for 2nd class hard wood 35 mm thick glazed and skeleton shutters, factory made, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, section 8, clause 8.20 (a), complete all as specified.
S&F butt hinges medium weight, cold rolled mild steel 100 mm size, complete all as specified.
S&F 300 mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified.
S&F 250 mm long aluminium alloy, anodised sliding door bolts with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded sections complete all as specified and directed.
S&F Mild steel pressed handles oval type stove enamelled black 150 mm size
S&F Mild steel barrel tower bolts, 200mm long, stove enamelled black, with bright bolt.
S&F Aluminum floor door stopper 63 mm with two rubber legged all as specified and directed
S&F magic eye brass best quality fixed in main door shutter approved by Engineer in charge complete all as specified and directed
S&F ordinary rat tail rod 300mm mild steel helical door spring with roller and plate complete all as specified and directed
S&F PVC solid door frame of size 50mm x 47mm made out of 5 mm plain/colour PVC sheet to be matched with shutter, reinforced with MS square tube, as per specification and drawing in SSR Part-II
S&F factory made solid panel pvc Door 30mm thick (style) consisiting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour 10mm thick PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 10 mm thick PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing.
S & F 30mm thick factory made PVC Flush Cup board shutter one sided decorated consisting of panel of hollow section thickness . Consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm inserted inside the hollow section of stiles. top and bottom rails and two 19mm x 19mm MS tubes inserted horizontaly inside the hallow profile section at an equal distance from top and bottom of door and fixed with hallow profile section using 5mm thick PVC sheet using screws Hollow PVC profile shall be lipped with 10 mm ( 5mmx 2) thick x 20mm width on stiles and rails using solvent cement . The inner panel shall be laminated with 5mm thick thick termite proof . water proof and fire retardant Prelam PVC sheet using solvent cement on both the sides of the panel etc. Complete all as specified as per direction of Engineer-in -charge.
S&F butt hinges medium weight, Stainless steel , bright polished 100 mm size for fixing PVC Door Shutter
S&F 150 mm aluminium anodised barel tower bolt, of extruded section and fixed complete all as specified
S&F 100 mm aluminium alloy handles, cast type, anodised complete all as specified
S & F Hasp & Staple aluminium 100 mm , including bolt to hinge plate and fixed with screws with Cup Board shutter, All as Specified
M&L Anodized aluminium window/ ventilator shutter side hung having 75 mm x 44 mm x2.85 mm thick stiles bottom rail and top rail including necessary ftting joinery cleat glasing packing snap beading 10 mm x 10 mm , 2 nos of anodixed aluminium handle 150 mm size, 2 nos of chromium pated butt hinges 75 mm size and 2 nos of 100 mm long Alu tower bolt etc inlcuding frame of section 100 mm x 44 mm x 2.85 mm and including 5.00 mm thick tinted glass and including aluminium grill and fixing including taking down of existing Chowkat with Shutter complete all as specified & directed by Engineer-in-Charge. Make of aluminium section Hindalco/Jindal
S & F framed work such as grills, gratings, etc .with ends of bars shouldered and/ or riveted , or forget into spikes ; framed guard bars barallel iron doors and similar work conforming to Fe.290.Gde-E-165
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks.
Hacking out old broken glass (any thickness, size quality or description) from wooden or steel frame glazed with putty or fixed with beads complete all as specified and directed .
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty wooden beads in square mtr n.exc 0.50 sqm each pane complete all as specified and directed .
M&L for 3 mm thick plain figure glass, pin headed type and fixing and glazing with in oil putty in sqaure n exc .5 sqm in each pane.complete all as specified and directed .
S&F 500 ltr cap rotational moulded polythylene water storage tank (Cylindrical vertical with closed top) white triple layer hosted and fixed in position incl dismantling of existing tank of any description complete all as specified.ISI marked. Make:- Sintex (Pure)/Sheetal/Rotex
S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight-210gms.)
S&F 20 mm stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed in repairs .
M&L for repairing of RCC projections, chajjas , roofs, facia etc. by necessary preparation i.e. scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, sufaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced with welded mesh of weight exc 2kg per sqmtr but n.exc 3kg/sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in patches are n.exc 70mm including applying two coats of finishes to match with the existing surfaces in at any height complete all as specified. Note:- Cost of formwork and welded mesh shall be deemed to be included in unit rate quoted by the contractor.
Dismantling of brick tiles single layer as in roof covering complete all as directed.
Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part thereof) all as directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges.complete all as specified and directed.
M&L 12 mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by water etc all as specified and directed by Engr in charge
Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V groove filled with repairs mortar/ microconcrate / general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight. Make: STP/Asian Paints/Sikka
Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold appliId of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator ” of given. Make: STP/Asian Paints/Sikka Note:- Contractor will provide certificate from authorised applicator.
M&L Cutting out cracks to V-section in existing RCC roof slabs or terracing , cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed
M&L for preparing new plastered or unplastered wall surfaces and applied two coat of cement base paint complete all as specified and directed by Engr-in-charge.
M & L for Complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and applied two coat of cement base paint complete all as specified and directed by Engr-in-charge.
M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of oil bound distemper over a coat of birla white putty complete all as specified.
M&L for three coats of white wash on newly plastered surfaces of wall including preparation of wall surfaces complete all as specified
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of ceiling surfaces complete all as specified and directed by Engr -in-charge.
M&L for prepration of old surfaces of ceilling including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc( Plastered or un plastered surfaces) and applying two coat of white (lime) wash on ceiling complete all as specified and directed by Engr -in-charge.
M & L complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and stooping of distempered and painted surfaces and applying two coat of oil bound distemper over a coat of birla white putty complete all as specified and directed by Engr -in-charge.
M&L for prepration of old surfaces of wall including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc ( Plastered or un plastered surfaces) and applying two coats of white (lime) wash on wall complete all as specified and directed by Engr -in-charge.
M&L for preparation of new wood or wood based surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr -in-charge.
M&L for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of red oxidezinc chrome primer complete all as specified and directed by Engr -in-charge.
M&L for preparation of old wood or wood based surfaces of any description, not otherwise described over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and directed
M&L for preparation of old steel surfaces of any description, not otherwise described over 10cm width or girth and applied one coat of synthetic enamel paint complete all as specified and directed by Engr -in-charge.
S&F in repair 18mm thick factory made PVC celuka ply for kitchen cupboard as in partation, shelves, wall,drawer ,shutter, etc of required colour and size consisting of pannels .The visible edge of celuka ply to be lipped by 18mm width X 2mm thick PVC cladding sheet of required colour and fixed with adhasive etc complete as per manufacturer instruction and directed.
S&F stainless steel self closing hinge of 75 mm size for PVC door shutter complete as specified and directed.
S&F 50 X 15 mm size magnet door catcher for closing for PVC door shutter complete as specified and directed.
S&F 100 mm size MS mat / glossy finish handle complete as specified and dirceted.
S&F stainless steel soap dish any type fixed to plugs with chromium plated brass screw complete all as specified and directed
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excludding precast concrete articles all as specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified.
S&F 60 mm thick precast cement concrete M-35 machine pressed inter locking tiles with grey cement and pigments (SI 15658:2006) all as specified
M&L for cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate ) as in sub base complete all as specified and directed
M&L for sand cusioning with layer of fine sand 25mm thick over PCC for laying of interlocking paver block complete all as specified and directed
Dismantling of asbestos cement (Corrugated, Semi-corrugated or plain) sheet as in roof coverings complete all as specified and directed.
Supply and fixing pre-painted galvalume aluminium zinc coating (AZ-150) GI based corrugated steel roof sheet 0.50 mm thick having tensile strength of 550mpa fixed with self drilling screwsas specified
S&F Rolled mild steel work in roof trusses (framed),trussed, purlins, rafters,crane gantries and heavy brackets framing (beams,tee,angle,channel or flat section) including MS plates, nutt bolts etc complete conforming to Fe 410-W(Gde, E-250) Quality A complete all as specified and directed.
Supplying and fixing steel windows 1.25 mm thick Box type (primer coated) ERW hollow 'P' section of size 60 mm x 25 mm single rebated comprises of glazed sutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf conisting two Nos sash bar of 'T' section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWR bot 'T' section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1, four Nos for each window including following fittings welded to failed shutter:- (a) Holdfasts 150 mm long 12mm x 3 mm made to shape- 4 Nos per window (b) Handle of Z sec 20 mm x 25 mm, 100 mm long - 1 nos per leaf. (c) MS tower bolt 150 mm long - 2 Nos per leaf. (d) 'Z' sec 20 mm x 25 mm , 100 long stopper-01 Nos per leaf, (e) Cleat 55mm long of hollow square 15 mm x 20 mm x 63 mm welded to hinges - 1 Nos per leaf (f) MS pintal hinges of size 75 mm x 12 mm - 2 Nos per leaf. (g) fabriction and fixing arrangement complete. Note:- Grill / guard war , glass pane shall be measured and Paid saperately.
All as per description of serial item No. 125 above but in gauged shutters without sash bars all as specified and directed
All as per description of serial item No. 125 above but in ventilators fixed type .
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS bosy of capacity 25 liters, BEE approved 5 star rating, heating element 2KW 230V, single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure asper latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 450mm long heavy duty suitable for Hot and cold water three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, B curve 240 Volts, AC supply complete all as specified and directed by Engr-in-Charge. Make of Sr item No. 127 to 128:- ABB/Schneider/Legrand
S&F MCB 'B' Curve suitable for 230 volts AC supply, 05 to 32 Amps, SP with over load and short cirsuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and directed by Engr-in-Charge.
M&L for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2.5 Sqmm single core (03 run i.e. 2 runs for main phase and netural, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volts drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangment i. e. PVC clamp, Rawl plug, Screw, PVC junction box, tee, bend etc.and including cutting of chases in wall and marking good disturbed surfaces of walls as per original complete all as specified and as directed by Engr-in-Chrage. Note:- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
S&F 15 mm bore steel water tubing, medium grade galvanized with all fittings and laid under floors or on walls and in ceilings in chases complete all as secified and directed.
S&F 15 mm bore stop valves/angle valve, cast copperalloy chromium plated fancy type, screwed down, high pressure with capstan heads, screwed for iron pipe or for union and fixed complete all as secified.
S&F 15 mm bore Bip taps, cast copper alloy chromium platedwith crutch or butterfly handle, screwed for iron pipe and fixed complete all as directed.
M&L for cutting existing steel tubing galvanized, screwing (each end) of size 15 mm bore for alterations or additions in existing pipeline complete all as specified and directed.
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for unsv light, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light, accessories for taking credit of unserviceable light and accessories as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and directed.
M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engr-in-Charge.
All as per srl item No.135 here in before but for one fan point controlled by one switch complete all as specified
All as per srl item No. 135 here in before but for one socket outlet 5 Amps on independent board complete all as specified.
All as per srl item No. 135 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
All as per srl item No. 135 here in before but for one bell point controlled by one bell push complete all as specified.
All as per srl item No.135 here in before but for one light point controlled by two way switches complete all as specified.
All as per srl item No. 135 here in before but with 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type, 6 Amps single pole, one way complete all as specified.
S&F switch piano flush type 16 Amps single pole, one way complete all as specified.
S&F socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
S&F Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 16 Amps, flush type complete all as specified.
S&F in replacement switch piano flush type, 5 Amps, AC single pole, two way, complete all as specified.
S&F ceiling rose surface type PVC/ polycarbonate 65mm x 50mm three terminal, complete all as specified.
M&L in replacement Bell electric AC (Ding Dong) 240 volt SP, complete all as specified.
S&F in replacement bell push switch flush type 5 Amps, single pole complete all as specified and directed.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with matching colour back plate all as specified and directed.
S&F five step fan regulator, electronic type, single phase, including connection complete all as specified.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including making good to disturbed surface complete all as specified and directed. Make:- Bajaj/Havells/Crompton
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 230m sweep with, blades, and frame and louvers making good to disturbed surface complete all as specified and directed. Make:- Bajaj/Havells/Crompton
Cutting holes for exhaust fan of size 300mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built inline mortar for inserting holdfasts and making good dismantled portion in cement mortar 1.3 or cement concrete 1:2:4 Type B-1 as required.
Cutting holes for exhaust fan of size 230mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built inline mortar for inserting holdfasts and making good dismantled portion in cement mortar 1.3 or cement concrete 1:2:4 Type B-1 as required.
S&F in repair Decorative wall mounting light fitting suitable for 09 watt LED lamp complete with glass shade/ polycarbonate cover including 1 x 09 watt LED lamp complete all as specified and directed by Engr-in-Charge. Make:- Bajaj/Havells/ Philips
Supply and fixing LED lights fitting 1x 20 Watt, 220V AC decorative box type frame with holder including LED tube rod 20 watt connecting up single/ double connections with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make:- Bajaj/Havells/ Philips
Supply and fixing LED light fitting mirror type with high out put diffuser 9/10 watt 220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete. Make:- Bajaj/Havells/ Philips
S & F LED light fitting 1 x 9/10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Bajaj/Havells/ Philips
S & F energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED bldg security lights with high efficiency electronic driver BIS approved, having IP-66 protection, surge protection operative on AC supply 140 volts to 270 volts pre-wired complete with GI pipe of 25mm bore of suitable length and MS clamp duly painted with two coat Aloxide paint all as specified and directed.
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6.0 Sqmm drawn through in and including new PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit.
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4.0 Sqmm drawn through in and including new PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 4.0 sqmm wire and one run of 4.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit.
M&L in replacement for sheet metal DB for MCBs, SPN, 8 ways, double door,single phase, with bus bar, neutral bar/ connectors suitable copper thimbles, lugs etc complete all as specified. Make: ABB/Legrand/Schnider
S&F MCB SP 6 to 32 Amps, 10 KA, B curve complete all as specified and directed by Engr-in-charge. Make:- ABB/Legrand/Schnider
S&F MCB SPN 32 Amps 240 V, 10 KA, B curve complete all as specified and directed by Engr-in-charge. Make:- ABB/Legrand/Schnider
M& L for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5 meter wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in hard / dense soil all as specified and as directed
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
Supply and laying old size sub class 'B' bricks laid flat in trenchs over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge.
M&L Sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and as directed
M&L for GI tube light grade 50mm bore laid in trenches or fixed on wall/floor for protection of UG cable complete all as specified and directed.
Taking down carefully of ceiling fan of any sweep or make with dismantling blades all as specified and directed by Engineer-in Charge.
Hanging of ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed by engineer in-charge
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, 5 star, BLDC type complete all as specified and directed. Make:- Havells/Bajaj/Philips
M&L for GI pipe heavy duty 40mm bore laid in trenches or fixed on wall/floor for fixing of ceiling fan complete all as specified and directed.
M&L for fan hook for fixing of ceiling fan suitable for 40mm dia GI pipe complete all as specified and directed.
Supply and fixing powder coated sheet metal enclosure indoor type(size width 1200mm,height 1400mm, depth 250mm) made out of 2mm thick CRCA sheet having independent compartments suitable for single phase energy meters- 08 Nos and MCB’s provided with front hinged shutters with locking arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment; duly prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 08 Nos duly crimped with copper thimbles, duly powder coated having one number cable gland for suitable size of LT XLPE/ PVC cable entry at bottom complete all as specified and directed and consisting with the following:- (a) Bus bar for 3 phase 4 wire system of 4 x 100 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front open able shutter - One Set.
Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and directed.
M&L for point wiring for one light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor single core of size 1.5 Sqmm cable, drawn through in and including non metallic concealed rigid PVC conduit medium grade (ISI marked) not less than 20mm dia with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible counduit etc and modular metal flush mounting box with white cover plate with frame of suitable number of module as requiredat site, brass/ cadmium plated steel screws including cutting chases on wall for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engr-in-Charge.
All as per srl item No. 182 here in before but for one socket outlet 5 Amps on independent board complete all as specified.
All as per srl item No.182 here in before but for one socket outlet 5 Amps on the same board controlled complete all as specified.
All as per srl item No. 182 here in before but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board and 20 Amp points for geyser including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F modular switch 1 way 6 Amps single pole, one module complete all as specified.
S&F modular switch 1 way 16 Amps single pole, one module complete all as specified.
S&F modular socket 6 Amps, 2-in-1, 5 pin combined 2 module complete all as specified.
S&F modular Socket outlet multi purpose 6/16 Amps, 2-in-1 5/6 pin combined 2 module complete all as specified.
S&F ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified.
M&L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
S&F 2 Module five step fan regulator, electronic type, single phase, including connection complete all as specified.
Supply and fixing in replacement LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily).
Supply and fixing in replacement LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 01, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
Supply & Fix in replacement MCB SP (in existing DB) 6 to 32 Amps 240 V, 10 KA, B curve complete all as specified and directed by Engr-in-charge. Make:- ABB/Legrand/Schnider
Supply & fix wall mounting fan 230 volts single phase 400 mm sweep, 3 speed, suitable for wall mounting type complete all specified and directed.
Taking down carefully of ceiling fan of any sweep or make with dismantling blades all as specified and directed by Engineer-in Charge.
M&L for hanging of ceiling fan of any sweep connecting all electric connections and testing complete all as specified and directed.
M& L in replacement for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete laid in trenches passing through pipes/culverts/ under roades/ along wall all as specified and directed by Engineer-in-charge.
M& L in replacement for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete laid in trenches passing through pipes/culverts all as specified and directed by Engineer-in-charge.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site.
M & L in replacement Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
M/S Vinod Kumar (BID ID -3281493)
NATIONAL BUILDERS (BID ID -3285712)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .