Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 CrAccepted-AOC F 31 INDUSTRIAL AREA PHASE VIII SAS NAGAR MOHALI 160071 | S A S NAGAR | PUNJAB | 160071 | ₹29.6 Cr Quoted ₹29.8 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹29.9 CrRejected-AOC 02 AB ADGAONKAR PLAZA NEAR ABB CIRCLE MAHATMA NAGAR NASHIK 422 007 MAHARASHTRA | NASHIK | MAHARASHTRA | 422007 | ₹29.9 Cr | L2 | Rejected-AOC Not being lowest bidder |
| 3 | L3₹39.9 CrRejected-AOC | ₹39.9 Cr | L3 | Rejected-AOC Not being lowest bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected due to not fulfilling the eligiblity criteria of PQC as per NIT |
| 5 | Rejected-Technical K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | - | - | Rejected-Technical Rejected due to not fulfilling the eligiblity criteria of PQC as per NIT |
| Sl No | Description | Qty | Unit | P L ADKE L2 | Hydrotech Paryavaran India Pvt. Ltd. L1 | Krushi Infras India Private Limited L3 |
|---|---|---|---|---|---|---|
| .50SCHEDULE 'A' PART - I | ||||||
| 1.00 | Design and Construction of Living Accn for Pump Operator with toilet (03 Nos) with permanent specification having Plinth Area of 25.90sqm each with RCC framed construction using M-25 (Design Mix) in foundation, footings, plinth beam, Columns, lintel, roof beam, roof slab, PCC Solid Block walling, pre-constructional ATT, 10mm thick Internal plastering in CM 1:6 & 15mm thick External plastering in CM 1:4, 5mm thick ceiling plastering in CM 1:3, finishing internal surface with 3 coats of white wash & external surface with 2 coats of cement based , WPT to roof with elastomeric membrane treatment, Rolling Shutter, Pressed steel door frame with flush shutter, glazed skelton door shutter, fly proof box type steel windows with MS guard bars, PVC door, 7 to 9mm non-skid rectified ceramic tiles flooring set and jointed in cement slurry over 20mm thick screed in CM 1:4 over 20mm thick PCC 1:2:4 type Bo over 75mm thick PCC 1:4:8 type D2 as sub-base, sanitary fittings & taps in toilets, plinth protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete at following locations all as specified and as directed :- | 1 | EACH JOB | 14,40,000 ₹14.4 L | 9,00,000 ₹9 L | 49,84,184.51 ₹49.8 L |
| 1.50protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete at following locations all as specified and as directed :- i) Zone I - 01 Block ii) Zone IA - 01 Block iii) Zone III - 0 1 Block ------------ Total - 03 Blocks ------------ Note : All Valves, pumps, pipelines, and items of internal electrification shall be measured under items at respective schedules. | ||||||
| 2.00 | Design and Construction of Living Accn for Pump Operator with Toilet including Labaratory (01 No) with permanent specification having Plinth Area of 37.00sqm each with RCC framed construction using M-25 (Design Mix) in foundation, footings, plinth beam, columns, lintel, roof beam & roof slab, PCC Solid Block walling, pre-constructional ATT, 10mm thick internal plastering in CM 1:6 & 15mm thick external plastering in CM 1:4, 5mm thick ceiling plastering in CM 1:3, finishing internal surface with 3 coats of white wash & external surface with 2 coats of cement based, WPT to roof with elastomeric membrane treatment, Rolling Shutter, | 1 | EACH JOB | 13,95,000 ₹13.9 L | 12,50,000 ₹12.5 L | 23,88,720 ₹23.9 L |
| 2.50Pressed steel door frame with flush shutter, glazed skelton door shutter, fly proof box type steel windows with MS guard bars, PVC door, 7 to 9mm non-skid rectified ceramic tiles flooring set and jointed in cement slurry over 20mm thick screed in CM 1:4 over 20mm thick PCC 1:2:4 type Bo over PCC 1:4:8 type D2 as sub-base, sanitary fittings & taps in toilets, plinth protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete all as specified and as directed. Note : All Valves, pumps, pipelines and internal water supply & electrification shall be measured under items at respective schedules. | ||||||
| 3.00 | Design (hydraulically, structurally and aesthetically) and construction of RCC Sump (Lift Well No.1 at Zone I) of size 3.0m inner dia and 3.3m overall depth with M-30 design mix concrete in foundation, sump walls, bottom & top slab, top slab with CI manhole cover, plastering, water proofing as per zonal specification, epoxy paint inside, Superstructure of pump room with PCC Solid Block walling, Internal & External plastering, finishing, RCC roof slab, Roof Treatment, Anti termite treatment all as per Zonal Specification, Floor tiling, PVC door, Flooring, etc., all as per zonal specification including necessary excavation in any type of strata, refilling of earth and disposal of surplus earth within 500m lead, all pipe connections, valves, MS ladder, ventilation shaft, complete including test for water tightness and hydraulic functioning complete all as shown on drawings as specified and as directed. | 1 | EACH JOB | 9,50,000 ₹9.5 L | 9,00,000 ₹9 L | 27,09,310.35 ₹27.1 L |
| 4.00 | All as per Item No.3 above but RCC Sump (Lift Well No.2 at Zone I) of size 3.50m inner dia and 4.70m overall depth | 1 | EACH JOB | 11,59,724.8 ₹11.6 L | 12,00,000 ₹12 L | 34,69,651.15 ₹34.7 L |
| 5.00 | All as per Item No.3 above but RCC Sump (Lift Well No.1 at Zone III) of size 3.50m inner dia and 4.05m overall depth) | 1 | EACH JOB | 10,31,148.8 ₹10.3 L | 11,15,000 ₹11.2 L | 33,43,448.86 ₹33.4 L |
| 6.00 | All as per Item No.3 above but RCC Sump (Lift Well No.2 at Zone III) of size 2.00m inner dia and 3.81m overall depth | 1 | EACH JOB | 5,51,054 ₹5.5 L | 6,50,000 ₹6.5 L | 17,02,855.95 ₹17.0 L |
| 7.00 | All as per Item 3 above, but RCC Sump (Lift Well No.3 at Zone III) of size 2.00m inner dia and 2.19m overall depth | 1 | EACH JOB | 4,16,430 ₹4.2 L | 5,50,000 ₹5.5 L | 17,38,244.13 ₹17.4 L |
Tender Value
₹30 Cr
EMD Value
₹15 L
Closing Date
22 Jul 2025, 6:00 pmClosed
Chief Engineer Chennai Zone
CChief Engineer Chennai Zone, Island Grounds, Chennai - 600009
PROVN OF SEWAGE TREATMENT PLANT AT AOC CENTRE SECUNDERABAD
2025_MES_698417_2
89090/E8
Open Tender
Civil Works
790 days
Secunderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
Yes
Garrison Engineer (Utility) Secunderabad
₹15 L
Yes
16 Sept 2025
24 Jun 2025
28 Jul 2025
24 Jun 2025
22 Jul 2025
8 Jul 2025
Amount
SCHEDULE 'A' PART - I
Design and Construction of Living Accn for Pump Operator with toilet (03 Nos) with permanent specification having Plinth Area of 25.90sqm each with RCC framed construction using M-25 (Design Mix) in foundation, footings, plinth beam, Columns, lintel, roof beam, roof slab, PCC Solid Block walling, pre-constructional ATT, 10mm thick Internal plastering in CM 1:6 & 15mm thick External plastering in CM 1:4, 5mm thick ceiling plastering in CM 1:3, finishing internal surface with 3 coats of white wash & external surface with 2 coats of cement based , WPT to roof with elastomeric membrane treatment, Rolling Shutter, Pressed steel door frame with flush shutter, glazed skelton door shutter, fly proof box type steel windows with MS guard bars, PVC door, 7 to 9mm non-skid rectified ceramic tiles flooring set and jointed in cement slurry over 20mm thick screed in CM 1:4 over 20mm thick PCC 1:2:4 type Bo over 75mm thick PCC 1:4:8 type D2 as sub-base, sanitary fittings & taps in toilets, plinth protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete at following locations all as specified and as directed :-
protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete at following locations all as specified and as directed :- i) Zone I - 01 Block ii) Zone IA - 01 Block iii) Zone III - 0 1 Block ------------ Total - 03 Blocks ------------ Note : All Valves, pumps, pipelines, and items of internal electrification shall be measured under items at respective schedules.
Design and Construction of Living Accn for Pump Operator with Toilet including Labaratory (01 No) with permanent specification having Plinth Area of 37.00sqm each with RCC framed construction using M-25 (Design Mix) in foundation, footings, plinth beam, columns, lintel, roof beam & roof slab, PCC Solid Block walling, pre-constructional ATT, 10mm thick internal plastering in CM 1:6 & 15mm thick external plastering in CM 1:4, 5mm thick ceiling plastering in CM 1:3, finishing internal surface with 3 coats of white wash & external surface with 2 coats of cement based, WPT to roof with elastomeric membrane treatment, Rolling Shutter,
Pressed steel door frame with flush shutter, glazed skelton door shutter, fly proof box type steel windows with MS guard bars, PVC door, 7 to 9mm non-skid rectified ceramic tiles flooring set and jointed in cement slurry over 20mm thick screed in CM 1:4 over 20mm thick PCC 1:2:4 type Bo over PCC 1:4:8 type D2 as sub-base, sanitary fittings & taps in toilets, plinth protection necessary excavation in all types of strata, refilling of earth and disposal of surplus earth within 500m lead, all soil waste pipe up to first manhole, etc., complete all as specified and as directed. Note : All Valves, pumps, pipelines and internal water supply & electrification shall be measured under items at respective schedules.
Design (hydraulically, structurally and aesthetically) and construction of RCC Sump (Lift Well No.1 at Zone I) of size 3.0m inner dia and 3.3m overall depth with M-30 design mix concrete in foundation, sump walls, bottom & top slab, top slab with CI manhole cover, plastering, water proofing as per zonal specification, epoxy paint inside, Superstructure of pump room with PCC Solid Block walling, Internal & External plastering, finishing, RCC roof slab, Roof Treatment, Anti termite treatment all as per Zonal Specification, Floor tiling, PVC door, Flooring, etc., all as per zonal specification including necessary excavation in any type of strata, refilling of earth and disposal of surplus earth within 500m lead, all pipe connections, valves, MS ladder, ventilation shaft, complete including test for water tightness and hydraulic functioning complete all as shown on drawings as specified and as directed.
All as per Item No.3 above but RCC Sump (Lift Well No.2 at Zone I) of size 3.50m inner dia and 4.70m overall depth
All as per Item No.3 above but RCC Sump (Lift Well No.1 at Zone III) of size 3.50m inner dia and 4.05m overall depth)
All as per Item No.3 above but RCC Sump (Lift Well No.2 at Zone III) of size 2.00m inner dia and 3.81m overall depth
All as per Item 3 above, but RCC Sump (Lift Well No.3 at Zone III) of size 2.00m inner dia and 2.19m overall depth
All as per Item 3 above, but RCC Sump (Lift Well No.4 at Zone III) of size 2.00m inner dia and 2.75m overall depth
All as per Item 3 above, but RCC Sump (Lift Well No.5 at Zone III) of size 2.00m inner dia and 3.96m overall depth
All as per Item 3 above, but RCC Sump (Lift Well No.1 at Zone IV) of size 2.00m inner dia and 1.68m overall depth
All as per Item No.3 above but RCC Sump (Lift Well No.2 at Zone IV) of size 3.00m inner dia and 2.75m overall depth
GENERAL SUMMARY NOTE : Schedule ‘A’ Part II to XII are under Ser No. 12.00 to 22.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for ROAD/ PATH as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for COMPOUND WALL & GATE as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY/ TREATED WATER SUPPLY as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for PRESSURIZED SEWAGE (E/M) as listed in Schedule ‘A’ Part-XII
SCHEDULE `A' PART - XIII to XVII are not prepriced by MES and prepriced rates indicating 0.00 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.
SCHEDULE 'A' PART XIII - STAND BY DG SET
Supply, installation, testing and commissioning of 160KVA silent Diesel engine Generating Set (The capacity of Generator Set shall be net after all due derating factors as per relevant lSI standard), 415Volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS:10001/ 10002 comprising of 160 KVA or equivalent, developing suitably derated of Minimum BHP @ 1500 RPM, Liquid Cooled, electric start coupled to alternator as per IS:13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, integral fuel tank with battery and leads and accessories complete in all respect with emission control device to control the PM within range as prescribed by latest NGT/ norms published vide GSR 804 (E) dt 03 Nov 2022 of GoI & updated till date on procurement of CPCB and CPCB approved acoustic enclosure suitable for ambient condition at Secunderabad including required PCC foundation as per manufacturers specification and confrrming to conditions under IS:10004722/1460, BS:5514/ 2613/ 5000, ISO:8526/3046 with following provisions :-
(A) Alternator : Standard design alternator rated at 160KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 phase, 4 wire, 415Volts, 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP:23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS:2613/5000 and shall be inposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS:2613/50001, IS:4722 and as per the following provisions :- Make: KIRLOSKAR/ JYOTI / STAMFORD/CATERPILLAR
(B) Diesel Engine : Adquate capacity Diesel engine suitably derated of Matching BHP for 160 KVA coupled drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS:5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- Make : KIRLOSKAR/ CUMMINS/ CATERPILLAR (GEMCO)
(a) Fly wheel with housing (b) Cooling system : Mounted radiator with fan & belts. (c) Cooling pump : Centrifugal type belt driven. (d) Exhaust System : Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade upto and away two meters height from top of enclosure incluing necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminium sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. The design should be as per latest exhaust emission limits for DG sets confirming to as set by MoEF & CC Gazette Notification No. GSR 804 (E) dt 03 Nov 2022 (amended up to dated, if any) complete all as specified and directed. Exhaust gas turbo charger type Exhaust manifold Silencer : Residential type Bellows
(C) Fuel System : Fuel injection system with fuel injectors, fuel injection solenoid switch/ nozzles/ governer electronic type capable for 1 % speed/ frequency regulation. (i) Fuel filters (ii) Fuel hoses (iii) Lub oil System :- (iv) Lubricating oil filter (v) Lubricating oil pump (vi) Air Intake System :- (a) Air intake Manifold (b) Air cleanler dry type
(D) Governer : Mechanical Governer (a) Starting System : Electric Self starter with maintenace free batteries including battery charging alternator. (b) Batteries : Required capacity and size Battery complete with copper conductor multistrnded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified. Make : EXIDE/ AMRON/ Produced by original DG set manufacturers
(i) Starter gear ring (ii) Start and stop push button (iii) Ignition key/ Switch (iv) Handling and operation : Salient features of accessories shall be as under :- (a) Radiator with blower fan (b) Corrosion inhibitor coolant (c) Paper element filters for fuel, lub oil and by pass. (d) Eelctronic governer controlled direct fuel injection system (e) Fly wheel housing and fly wheel.
(E) Generator Monitoring Panel : Comprising of following :- (a) Microprocessor based integrator generator set monitories, metering, protection and control system with built torque matched Volts/ H3 over load control. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (d) Relay drivers for remote annuciations (e) Cyclic cranking (f) Auto/ manual start stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0-50°C and humidity upto 95% (j) Remote monitoring capabilty through separate interface modules.
(k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed (rpm), run hours, DC voltage, 3 phase Volts and 3 phase amperes, frequency, KW, KVA, power factor (l) Safety Controls : Engine low lube oil pressure, high water temparature and over speeding of engine. (m) Coupling arrngement : Flexible coupling, fly wheel to suit flexiable coupling fly wheel housing. (n) Accessories : A VM Pads built or separtely mounted to manufacturer base frames. (p) Base Frame : Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (q) Fuel Tank : Daily service fuel tank of capacity suitable for 12 Hours consumption on full load (Inbuilt) made out of 3mm thick (Heat Retradant) sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in bulit inside the accoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design. (r) Deliverables : Confirms the norms established by CPCB.
(F) AMF PANEL : (a) Auto Main Failure (AMF) panel made out of minimum 2mm thick CRCA sheet, powder coated of conforming to IS:8623 totally enclosed dust and vermin proof with front and rear openings of 415Volts, 3 Phase, 4 Wire, AC, 50 Hz having aluminium bus bar capacity required to carry current at 100% load of DG set with three phase and half neutral colour coded, prewired with copper flexible cable, all as specified and directed with the following accessories, control cable from Gen set to AMF panel :-
(i) 4 pole contactor of suitable capacty - 2 Nos. (ii) MCCB, 4 Pole as per OEM design -2 Nos (One for Alternator and one for Commercial Supply) with suitable fuse links. (iv) CTs suitable rating for both the supplies. (v) DC Ammeter. (vi) DC Voltmeter. (vii) Push buttons. (viii) Indication Lamps. (xvi) Six window anunciator for fault indications. (xvii) Electro magnetic relays. (xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains : A, V, Hz.
(G) Acoustic enclosure : CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type, which shall consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features :-
(a) Custom built product for various equipments, with ensure the optimum performance without duration. (b) Rugged in construction maintenance free and modular designs which facilitate easy at site. (c) 16 SWG (1.6mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS:8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (d) Sheet metal components of the enclosure should undergo various stages of surfacetreatment prior to painting which leads to be better life of the enclosure against weathering action.
(e) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (h) Working space is to be provided around tbe equipment for easy maintenance/ repairs. (j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per tbe requirement.
(e) Special paint treatment with pure polyester powder/ epoxy to be provided for better weather resistance. (f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic/ weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (h) Working space is to be provided around tbe equipment for easy maintenance/ repairs. (j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per tbe requirement. Make for AMF PANEL : DG SET OEM Make for ACCOUSTIC PANEL : DG SET OEM
All as per Item No. 23 above but DG Set capacity of 100 KVA
All as per Item No.23 above but DG Set capacity of 82.5KVA
All as per Item No.23 above but DG Set capacity of 10KVA
SCHEDULE 'A' PART XIV- SEWAGE TREATMENT PLANT
Design, Supply, Construction, Installation and Testing & Commissioning of Sewage Treatment Plants (STP) based on principle of aerobic attached growth non-clogging randomly Moving Bed Bio-reactor Technology (MBBR) as per the given specifications and drawings having the capacities given below including all civil works, mechanical works, pumps, blowers, chemical dozers & piping works, electrical works, LT Panel, cabling & instrumentation works, fabrication works, Human intervention free automation of pumping at various stages & SCADA including On line Continuous Effluent Monitoring System (OCEMS) for monitoring of treated water parameters, all types of instrumentation & Data cabling and all other allies works so as to achieve the required parameters in accordance with the latest engineering practice complete all as specified and
as directed and the detailed scope of work under this item along with specifications from the collection sump to various stages of STP up to storage of treated water & final treatment of sludge including automation & SCADA so as to achieve the required parameters b ased on Design Datas all as specified in Particular Specification Clause 29 of tender documents and main scope of work covered in the item is as under :- (a) 26 KLD STP (Package Type) – 01 Number (b) 250 KLD STP – 01 Number (c) 500 KLD STP – 01 Number (d) 850 KLD STP – 01 Number (e) OCEMS – 01 Number at each STP (f) SCADA System for all above STPs with local server (no cloud hosting is permissible) – 01 Number with two display monitors at GE and AGE Office.
SCHEDULE 'A' PART XV- LABORATORY ITEMS
Supply, install, testing and commisioning of Lab Stirrer complete all as specified and as directed.
Supply, install, testing and commisioning of centrifuge complete all as specified and as directed.
Supply, install, testing and commisioning of PH Meter complete all as specified and as directed.
Supply, install, testing and commisioning of Turbidity Meter complete all as specified and as directed.
Supply, install, testing and commisioning of Titration complete all as specified and as directed.
Supply, install, testing and commisioning of Colorimeter complete all as specified and as directed.
Supply, install, testing and commisioning of Autoclave complete all as specified and as directed.
Supply, install, testing and commisioning of Analytical balance complete all as specified and as directed.
Supply, install, testing and commisioning of Desiccators complete all as specified and as directed.
Supply, install, testing and commisioning of Hot air oven complete all as specified and as directed.
Supply, install, testing and commisioning of Water Bath complete all as specified and as directed.
Supply, install, testing and commisioning of Samples complete all as specified and as directed.
Supply, install, testing and commisioning of Frost free Refrigerator, electric driven 230Volts, 50 Hz, working on R-134(a) or superior environment refrigerant, puff insulated body, BEE 5 star rated having nominal storage capacity not less than 200 Ltrs complete all as specified and as directed.
Supply, install, testing and commisioning of COD Sensor/ Probe complete all as specified and as directed.
Supply, install, testing and commisioning of DO Sensor/ Probe complete all as specified and as directed.
SCHEDULE 'A' PART XVI- FIRE FIGHTING ITEMS
S&F non-skid rubber mat 16mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for LT Panels complete all as specified and as directed.
S&F fire bucket painted red and duly filled with sand conforming to IS: 2546-1974 complete all as specified and as directed.
&F MS stand suitable for supporting two buckets (Pedestal type) complete all as specified and as directed.
S&F of MS stand suitable for supporting four buckets (Pedestal type) complete all as specified and as directed.
S&F shock restoration chart written in English and Hindi duly framed in as required complete all as specified and as directed.
S&F 4.5Kg, CO2 Type Fire Extinguisher Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg, Empty Weight 14.6 Kg, Can Height 860MM, Diameter 140MM, Discharge time minimum 13 Secs, Controllable discharge mechanism, Range minimum 2 Meters, Applicable on Class B,C & electrically started Fire, B Rating 13B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal complete all as specified and as directed.
S&F first aid box as approved complete with standard kit as prescribed by Indian Red Cross complete all as directed and specified.
S&F Medium Voltage (MV) Danger Notice Plate of 200mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required complete all as directed and specified.
SCHEDULE 'A' PART XVII- MISCELLANEOUS ITEMS
INTERNAL ELECTRIC SUPPLY
One light/ fan point controlled by one switch.
One 3 Pin modular socket 5/6 Amps outlet on independent board
One 3 Pin modular socket 5/6 Amps outlet on same board
All as per Item No. 51 above but Point Wiring with 4 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, Copper conductor FRLSH cable of 1100Volts grade including provn of 4sqmm PVC insulated unsheathed Copper conductor cable of green colour for earth continuity and connecting to common earth dolly, etc., for one 3 pin switch socket outlet (plug point) 15Amps switch socket combination on independent board incl continuous earth wire connecting to common earth and earth dolly complete all as specified and directed.
Supply, install, testing & commissioning of Exhaust Fan, metal body with automatic back shutter louvers 250mm sweep, single phase, 240 Volts, AC, 50 Hz all as per Cat No. Ventil Air - DS of Havells or techno-commercially equivalent of other specified makes including cutting hole in to the wall and making good the disturbed surfaces and connecting up complete and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose, etc., complete all as specified and as directed. Note : The unit rate quoted shall be deemed to include the cost any framework/cement work/wood work/ welding work, etc., required for proper fixing of the exhaust fan and matching to the existing surface.
S&F 20 Watts surface/ wall mounted LED batten having PC diffuser, luminous efficacy of minimum 100 lumen/ W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS:15885 (Part-2/Sec-13) - 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP:20 protection, input voltage range : 140-270 Volts, input frequency 50-60 Hz including electrical connection with 3 core flexible Copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
All as per Item No 54.00 above but 10 Watts
S&F LED Bulb, 9 Watts, B22, BEE star rated with minimum 3 star rating complete all as specified and as directed.
S&F 35 Watts security light fitting having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 110 lumen/ Watt, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13)-2012, IP:66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, wall mounting with bracket arm OD 35mm to 42mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5m long bracket, having 40mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed.
SEWAGE DISPOSAL
S&F for HDPE DWC Pipe 150mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.
S&F for HDPE DWC Pipe 200mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.
S&F for HDPE DWC Pipe 250mm ID SN-8 (IS:16098 II) 6.0m length laid in trenches and jointed in collars complete all as specified and as directed.
M&L for fixing PVC coated MS Rungs (with 12mm dia TMT bar) for septic tank and manhole complete all as specified and as directed.
M&L for construction of Flush Tank of size 01mtr x 01mtr x 01mtr with PCC block masonry walls including PCC bed, CI manhole cover, plastering, PVC coated MS Rungs, inlet & outlet, necessary earth work, excavation, etc., complete all as shown on drawings and as specified.
EXTERNAL WATER SUPPLY/ TREATED WATER SUPPLY
S&F PP-R gate valves (brass insert) of size 90mm bore complete all as specified and as directed.
M&L for construction of valve chamber of 90x90x 90cm inner dimensions, brick masonary in CM 1:4 including PCC 1:3:6 of 75mm thick in bed, plastering 15cm thick in CM 1:4 in inner walls, coping, MS cover 3mm thick fabricated with Iron frame using 40x40x6 mm size angle iron with hinges and locking arrangements duly painted, excavation, earth work, etc., complete all as specified and as directed.
M&L for construction of valve chamber of 60x60x 60cm inner dimensions, brick masonary in CM 1:4 including PCC 1:3:6 of 75mm thick in bed, plastering 15cm thick in CM 1:4 in inner walls, coping, MS cover 3mm thick fabricated with Iron frame using 40x40x6 mm size angle iron with hinges and locking arrangements duly painted, excavation, earth work, etc., complete all as specified and as directed.
S&F full circle metal impact sprinkler, corrosion proof I beam construction for added strength, Stainless Steel spindle, fulcrum pin and spring well balanced gun metal swing arm to ensure smooth and uniform rotation, Brass nozzles with hydro dynamically designed inner profile for precise jet and longer radius of throw 360 degree angle view complete set all as specified and as directed.
Supply, install, test and commissioning of Centrifugal self priming monoblock pump set capable of pumping 28.2LPS at 18 Mtr head of minimum 10HP capacity, electrically driven 3 phase, 50Hz, 415Volts energy efficient with IE2 motor efficiency with cast iron impeller & motor body and SS pump shaft, squirrel cage TEFC induction motor 3 phase, 415Volts, AC, 50 Hz, IP:55 protection, Class F insulation, suction & delivery pipe of 100mm x 80mm size coupled on common base chanel including necessary PCC foundation works, nuts & bolts, suitable size copper cable from starter to motor through PVC flexible pipe, suitable size of suction pipe not less than 20 feet or as requiredd at site, air release valve, foot valve on suction side, etc., complete all as directed and specified. Make : Kirloskar Model KDI 1030 EE2 or equivalent
All as per Item No.67 above but Centrifugal self priming monoblock pump set capable of pumping 18.2LPS at 18 Mtr head of minimum 7.5HP capacity with suction & delivery pipe of size 65mm x 50mm. Make : Kirloskar Model KDI 830 EE2 or equivalent
All as per Item No.67 above but Centrifugal self priming monoblock pump set capable of pumping 9.2LPS at 16 Mtr head of minimum 3 HP capacity with suction & delivery pipe of size 65mm x 50mm Make : Kirloskar Model KDI 318 EE2 or equivalent
All as per Item No.67 above but Centrifugal self priming monoblock pump set capable of pumping 1.8LPS at 16 Mtr head of minimum 3HP capacity with Carbon Steel pump shaft and suction & delivery pipe of size 65mm x 50mm Make : Kirloskar Model : GMC-128 or equivalent
Cutting the existing road of any kind straight by manual, depth and width not less than 30cm for pipes up to 100mm dia for pipes and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
M&L for shifting of the any make of transformer rating 100 KVA mounted on plinth/ pole from existing location to new location including removing and reconnections of HT/LT side, jumper/ cable connection, control cable connection of transformers including testing complete all as directed. Note : The rate quoted shall be deemed to be inclusive of necessary crane/ vehicle charges for shifting and installation of the transformer.
M&L for concrete foundation suitable for 160KVA Transformer as per OEM recommendation of minimum size 1.80m x 1.50m x 1.50m (above GL) and 2.20mx 1.90mx1.0m (below GL) inlcuding excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete, RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick PCC coping including RFR, removal of surplus soil and three coats of white wash, etc., complete all as specified and directed.
Supply, installation, testing and commissioning of LT feeder pillar box, factory made, CPRI type approved, outdoor type floor mounting with channel iron pedestal frame made out of 3mm thick CRCA sheet steel for outer body and 2mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 Volts, 3 phase, 50 Hz, AC supply, vermin proof, front and rear opening, hinged doors, etc., powder coated as per seven tank process with IP:65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts, bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, Digital Ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears :- Location : STP P/H Panel (Zone-IA) (a) 125 Amps MCCB FP 25 KA - 01 No (Incoming) (b) MCCB FP 100Amps 25 KA - 1 No (STP Panel) (c) MCCB FP 20Amps 16 KA - 3 Nos (P/H-01, SL-01 & Spare). (d) MCCB FP 20Amps 16 KA - 3 Nos (Treated water) (e) Digital Voltmeter 0 to 415 Volts
(f) Digital Amp meter 0 to 200 Amps with CT (g) DOL starter suitable for 5 HP Pump Set (Treated Water) - 02 Nos (h) Street Light timer switch with contactor SPN - 01 No
All as per Item No 74 above but comprising of the following switch gears :- (a) 40 Amps MCCB FP 16 KA - 01 No (Incoming) (b) MCCB FP 25 Amps 16 KA - 01 No (STP Panel) (c) MCCB FP 16 Amps 16 KA - 3 Nos (Treated-02 Nos). (d) Digital Voltmeter 0 to 415 Volts (e) Digital Amp meter 0 to 200 Amps with CT (f) DOL starter suitable for 1 HP Pump Set (Treated Water)- 02 Nos Location : STP P/H Panel (Zone-IB)
All as per Item No 74 above but comprising of the following switch gears :- (a) 200 Amps MCCB FP 36KA - 01 No (Incoming) (b) MCCB FP 160 Amps 25 KA - 2 Nos (STP Panel+ Spare) (c) MCCB FP 63 Amps 16 KA - 1 No (APFC panel) (d) Digital Voltmeter 0 to 415 Volts (e) Digital Amp meter 0 - 200 Amps with CT (f) Street light timer switch with contactor 4P - 01 No Location : Zone-III (Main LT Panel near Transformer)
All as per Item No 74 above but comprising of the following switch gears :- (a) MCCB FP 160 Amps 35 KA - 1 No (Incoming) (b) MCCB FP 100 Amps 25 KA - 1 No (out going for STP) (c) MCCB FP 25 Amps 16 KA - 1 No (d) MCCB FP 20Amps 16 KA - 05 Nos (out going for LW1, LW3, TW Pumps-2, PH-1) Location : Zone-III (STP P/H Panel)
All as per Item No 74 above but comprising of the following switch gears :- (a) MCCB FP 315 Amps 35 KA - 1 No (Incoming) (b) MCCB FP 250 Amps 25 KA - 1 No (out going) (c) MCCB FP 100 Amps 25 KA - 1 No (out going) (d) Street light timer switch with contactor & MCB 16A TPN - 01 No Location : Zone - IV & V (Main LT Panel near Transformer)
All as per Item No 74 above but comprising of the following switch gears :- (a) MCCB FP 250 Amps 36 KA - 1 No (Incoming). (b) MCCB FP 160 Amps 36 KA - 1 No (STP) (c) MCCB FP 40 Amps 25 KA - 02 Nos (PH & STP) (d) MCCB FP 32Amps 25 KA - 02 Nos (Treated) (e) MCCB FP 20 Amps 25 KA - 01 No (ILW-1) (f) Star Delta starter suitable for 12.5 HP Pump Set (Treated Water)- 02 Nos Location : Zone - IV & V (STP P/H Panel)
Notes for Item Nos.74 to 79 : The rate quoted shall be deemed to be included for all out going/ incoming cable connection marking including digging out loop, writing of feeder names with white paint in capital letters, suitable size of glands & lugs to be provided for cable, etc., complete.
S&F hot press moulded SMC junction/ terminal box of size with internal diamensions of 200x140x95mm with hinged door including provision of 2 way connector 415Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3mm including dismantling of old unserviceable all as specified and as directed. Make : Hensel/Syntex/C&S
Design, manufacture, supply, install, test and commission Automatic Power Factor control panel 50KVAR capacitor bank in 4 steps as indicated below with microprocessor best controller units suitable for operation on AC 415Volts, 50 Hz ,supply, suitable for installation outdoor wheatherproof type, front with hinge type door and locking arrengement bottom with detachable sheets for cable entry/ exit, top with sloping canopy fabricated with 3mm thick MS sheets suitable size to install following switchgears/ items, powder coated both inside and outside, complete panel board install on suitable PCC pillar with bolts and nuts grouted to pilars and comprising following switchgear/ capacitors control gear, etc., all as specified and as directed. Location : Zone IV & V
(a) Incomer MCCB TPN 100 Amps 25 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Aluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitor 25 KVAR super heavy duty long life for industrial load - 01 No (e) Capacitor 15 KVAR super heavy duty long life for industrial load - 01 No (f) Capacitor 5 KVAR super heavy duty long life for industrial load - 02 Nos including suitable capacities contactors, MCBs, Fuses, Relays, Digital type indicating meterss for voltage, current, PF, etc., complete internally prewired with copper conductor.
All as per Item No.81 above, but Automatic Power Factor control panel 30 KVAR rating and comprising the following : Location : Zone III (a) Incomer MCCB TPN 63 Amps 16 KA - 01 No (b) Current Transformer 100/5 Amps - 03 Nos (c) Aluminium bus bar insulated TPN 200 Amps - 01 set (d) Capacitor 15 KVAR super heavy duty long life for industrial load - 01 No (e) Capacitor 5 KVAR super heavy duty long life for industrial load - 03 Nos including suitable capacities contactors, MCBs, Fuses, Relays, Digital type indicating meterss for voltage, current, PF, etc., complete internally prewired with copper conductor.
M&L for spreading riddled earth (obtained and prepared from excavated earth) for sand cushioning of cable laid in trenches/ duct complete all as specified and directed by Engineer-in-Charge. Note : Punned thickness 18cm (6.25cm below cable and 11.75 cm above cable) shall be measured for payment purpose. The unit rate quoted shall deemed to be inclusive of all arrangement as mentioned.
Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable, HDPE pipe medium duty of size 100 mm dia and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20mm graded aggregate stone complete all as specified and directed.
PRESSURIZED SEWAGE (E/M)
195 LPM at 15mtr head (For LW No.1 at Zone-I)
350 LPM at 15mtr head (For LW No.2 at Zone-I)
325 LPM at 15mtr head (For LW No.1 at Zone-III)
60 LPM at 15mtr head (For LW No.2 at Zone-III)
80 LPM at 15mtr head (For LW No.3 at Zone-III)
35 LPM at 15mtr head (For LW No.4 at Zone-III)
25 LPM at 15mtr head (For LW No.5 at Zone-III)
30 LPM at 15mtr head (For LW No.1 at Zone-IV)
410 LPM at 15mtr head (For LW No.2 at Zone-IV)
Supply, Installation, testing and commissioning of LT feeder pillar box (PLC/RTU Panel), factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3mm thick CRCA sheet steel for outer body and 2mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440Volts, 3 phase, 50 Hz, AC supply, vermin proof, front and rear opening, hinged doors, etc., powder coated as per seven tank process and IP-65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm, 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps, PCC works, etc., complete all as specified/ directed and shall also consist the following:-
(a) Programmable logic controller (PLC) or Remote Terminal unit (RTU) for automatic human intervention free operation of pumps as per scope of work & automation logic as given in Particular Specification Clause 29 of tender documents mainly comprising Ultrasonic liquid level sensor/ transmitter, Data transmission equipments required for integrating with SCADA, any associated instrumentation, cabling requirement for panel internal wiring, communication, networking, etc,.
(b) MCCB FP 32 Amps 16 KA - 1 No (Incoming) (c) MCCB FP 25 Amps 16 KA - 3 Nos (Outgoing) (d) MCB SPN, 10 Amps, 10 KA - 01 No (e) Starter suitable for up to 3 HP Submersible Pump - 03 Nos (f) Relays, contactor & any other balance of item to make the Panel fully functional, compatible with the SCADA and the pumpsets. (g) Rain Shed using coloured Galvalume sheet and of adequate size over each Panel to avoid any direct rain fall on the panel. The Panel shall also have suitable IP rating to avoid ingress of moisture leading to malfunctioning of sensitive electronic components. Note : One Panel is to be installed at each intermediate Lift Well as given under BOQ Item No.85
S&F Ductile Iron pressure pipes, class K7, centrifugally cast with spigot and socket ends 100mm dia conforming to IS:8329/ 2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including all jointing materials and making good for disturbed surfaces of roads, path ways, etc., while laying the pipe line at site, site clearance for the route of pipe line, welding, etc., complete all as specified and as directed.
(d) Civil road croossing wherever required shall be done by the contractor. Necessary permission for crossing road/ laying of pipe form GHMC/ Cantt Board/ any other civil department including necessary fee if any applicable is the responsibility of the contractor. No Claim in this regard will be entertained during execution stage. Department only shall assit for obtaining approval. (e) Contractor should visit the site to understand the site condition before quoting the rates. No claim regarding site condition will be entertained during execution stage.
S&F DI specials such as bends (any type, radius or angle) tapers any type (straight, bend, increase, decrease or double socket, etc.,) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs, etc., up to 150mm bore complete all as specified and directed.
Cutting the existing road of any kind straight by manual, depth and width not less than 30cm for pipes up to 100mm dia for pipes and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate complete all as specified and directed.
EARTHING
M&L for Earthing complete with 6.0mm thick galvanized steel earth plate electrode of size 600mm x 600mm, burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical Plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB all as specified including testing on completion with and including 15mm bore medium grade GI protection pipe upto 7.5 meter long for GI earth wire including PCC 1:3:6, type C-1 pit with 40mm thick precast RCC 1:2:4, type B-1 cover reinforced with 8mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
SCHEDULE 'A' PART XVIII - MANNING AND OPERATION OF STP - PHASE III (DURING DEFECTS LIABILITY PERIOD OF 2 YEARS)
Manning & Operation of Sewage Treatment Plants along with automation & SCADA system of capacities 850 KLD, 500 KLD, 250 KLD & 26 KLD at different locations of AOC Centre Secunderabad installed under BOQ Item No. 27.00 during first year of defect liability period of 02 years for the duration of 24 hours round the clock, starting from next day of certified date of physical completion complete inclusive of all consumables, daily, weekly, monthly, quarterly, Half yearly & Yearly maintenance of equipment and complete all as per scope of work along with terms & conditions given in Particular Specification Clause 29.14 to 29.14.5 of tender documents. Note : (i) Sewage water for the STPs & electricity required for operation of STPs shall be provided free of cost. (ii) Treated Sewage water will be utilized by MES and user units as per their requirement and surplus water will be drained to nearby nallah. Required pumps and valves for the purpose at STPs are also to be operated & maintained by the contractor. (iii) De-watered sludge will be the property of the contractor for further disposal to any location outside defense land under his own arrangement.
All as per Item No.92 above but for second year of defect liability period
SCHEDULE 'A' PART XIX - COMPREHENSICVE OPERATION AND MAINTENANCE OF STP - PHASE IV (8 YEARS AFTER DEFECTS LIABILITY PERIOD)
Comprehensive Operation and Maintenance of Sewage Treatment Plants along with automation & SCADA system of capacities 850 KLD, 500 KLD, 250 KLD & 26 KLD at different locations of AOC Centre Secunderabad installed under BOQ Item No. 27.00 during first year of defect liability period of 02 years for the duration of 24 hours round the clock, starting from next day of certified date of physical completion complete inclusive of all consumables, daily, weekly, monthly, quarterly, Half yearly & Yearly maintenance of equipment and complete all as per scope of work along with terms & conditions given in Particular Specification Clause 29.14 to 29.14.5 of tender documents. Note : (i) Sewage water for the STPs & electricity required for operation of STPs shall be provided free of cost. (ii) Treated Sewage water will be utilized by MES and user units as per their requirement and surplus water will be drained to nearby nallah. Required pumps and valves for the purpose at STPs are also to be operated & maintained by the contractor. (iii) De-watered sludge will be the property of the contractor for further disposal to any location outside defense land under his own arrangement.
All as per Item No.92 above but for 2nd year after defect liability period
All as per Item No.92 above but for 3rd year after defect liability period
All as per Item No.92 above but for 4th year after defect liability period
All as per Item No.92 above but for 5th year after defect liability period
All as per Item No.92 above but for 6th year after defect liability period
All as per Item No.92 above but for 7th year after defect liability period
All as per Item No.92 above but for 8th year after defect liability period
P L ADKE (BID ID -3351914)
Krushi Infras India Private Limited (BID ID -3357782)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid