| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.4 L+₹4.3 L (21.7%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹24.5 L+₹4.4 L (22.1%)Rejected-Finance PO PS JANG DISTRICT TAWANG ARUNACHAL PRADESH 790104 | JANG | TAWANG | ARUNACHAL PRADESH | 790104 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹25.0 L+₹4.9 L (24.7%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹28.5 L+₹8.5 L (42.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹27.7 L
EMD Value
₹55,500
Closing Date
12 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR / REPLACEMENT OF OH LINE / GODS IN TO RMUs AT CENTRAL POWER HOUSE UNDER GE (UTILITIES) UDHAMPUR
2024_MES_638182_1
CWE/U(U)-95/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Udhampur
As per NIT
6 documents required · 6 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹55,500
10 May 2024
19 Jan 2024
19 Feb 2024
19 Jan 2024
12 Feb 2024
6 Feb 2024
19 Jan 2024 - 31 Jan 2024
Amount
Dismantling/Taking down the unserviceable HT 11KV Pole structures from the Central Power House Substation Removing away from the site and depositing in MES storeyard, all as specified and directed by Engineer-in-charge.
Supply, install, testing and commissioning of 11KV 630 Amps 21KA for 3 sec SF6 insulated. One side extensible outdoor duty Manual Eight (8) way Ring main unit in combination of 1 Nos Load Break SWITCH modules and 7 Nos VCB Modules consisting of copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer fixed with series trip self-powered microprocessor based numerical over current relay (IDMTL+ Inst) in each VCB feeder, Suitable CT for protection to be provided with each VCB Feeder. The HV switchgear and control gear should be confirming to IEC-62271-1 100/200. The RMU should be internal arc tested for 21 KA for Second with IAC-AFLR classification for gas tank & cable box. The complete RMU front along cable chamber to be covered by an seperate outdoor door to have ingress protection of minimum IP54 The RMU design should support site replaceable HT cable bushing and VI of VCB should be RMU Manufacturer's own make. Each feeder of should have voltage presence indicator.
(Srl item No 2 Contd) All the type test certificated as per IEC from Third party lab to be submitted RMU should have followings:- (i) 1 No microprocessor based self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder (ii) 3 Nos Protection CT shail be of Burden 2.5 VA ratio 100-50/1A Class of Accuracy class 5P10 for O/C and E/F protection for (4 outgoing) and 75-50/1A for (4 outgoing) (iii) VCB should confirm operating saquence O-0 3Sec - CO-3min-CO and 10000 mechanical operation (iv) 1 No Manometer for each tank (v) 1 No Voltage Passage indicator for each feeder (vi) 1 Nos fault passage indicator for each RMU (vii) Right angle boots for all the feeder Modules Make of RMU: ABB/ SIEMENS/ SCHNEIDER INFRA (No System house/ fanchise license partner is approved)
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3.15mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanized iron earth strip 25x4 mm size by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 4 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 03 Contd … (e) 40 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
SACHDEVA BUILDERS
N K BUILDERS
MOHAN LAL AND SONS
M/S BHARAT LIGHT ELECRIC.CO
PROACH ASSOCIATES BUILDERS & ENGINEERS
FANGALIA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .