Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC AT PRATAP BAGAN LANE NO 07 P O BANKURA DIST BANKURA PIN 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹2.1 L+₹6,824 (3.43%)Rejected-Finance 334 SCHOOLDANGA BANKURA BANKURA PIN 722101 WEST BENGAL | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹2.1 L+₹11,540 (5.80%)Rejected-Finance AB 253 SALT LAKE KOLKATA 700064 | KOLKATA | KOLKATA | WEST BENGAL | 700064 | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹5,004
Closing Date
31 Jul 2024, 12:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Requirement of AC machine in Library room in the Dept of G and O at G and O Building, BSMCH, Bankura.
2024_WBPWD_722132_1
WBPWDTE/ AE /BMCESD /NIQ-15/ Q of 2024-25_2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,004
Yes
22 Aug 2025
26 Jul 2024
2 Aug 2024
26 Jul 2024
31 Jul 2024
26 Jul 2024
Amount
Supply & Fixing of 250V 50 HZ OLP- 30A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supplying and fixing of 250 V AC timers fixed on wall with flat iron frame as per direction of EIC and the Box shuld be comprising with the following accessorise --- i) Double-door SPN MCB Distribution Board with IP-42/43 protection 10 / 12 way Enclosureas reqd . ( Make - Legrand / L & T ) – 1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no iii) 250 V, 50 Hz , 40 Amp DP Conctractor with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no iv) 250 V, 50 HZ , 40 Amp , DP MCB Isolator ( Make - Legrand / L & T ) – 1 no v) Auto / Manual By pass Toggle Switch arrangement – 1 no. vi) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T ) – 1 no vii) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power . viii) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / Crabtree )
Supply & Delivery of 230V, 50Hz 3 Star rated 2 ton capacity Split Air-conditioner machine fitted with Hyper Tropical Rotary compressors suitable for Refrigerant-R410A, Standrad Colling Capacity 6450 W Power Consumption Capacity 1870W Moisture Removal 2.3 I/H Air Flow 1060 Cu.Mt/Hr. (Make- Hitachi Model- Kashikoi 5100X 2.0TR - RMOG422HDXA) or equvalent model of O-General/Daikin/ PWD Appvd ) with Remote etc . to complete with 25 Amp suitable plug top (North West/appvd) as per direction of EIC) (01 st june'2022)
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Swarnendu Sarkar
SUBHRA ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .