Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 CrAccepted-AOC 44 TARUN NAGAR GUWAHHATI P O CHRISTIAN BASTI PS BHANGAGARH KAMRUP METRO PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹24.3 Cr | L1 | Accepted-AOC Being lowest evaluated responsive bidder |
| 2 | Rejected-Technical HOUSE NO 108 SADILPUR P O PANDU P S JALUKBARI DIST KAMRUP M ASSAM PIN 781012 | KAMRUP METRO | ASSAM | 781012 | - | - | Rejected-Technical Technically Rejected |
| 3 | Rejected-Technical 4B TOWN SQUARE CHINAR PARK RAJARHAT KOLKATA 700 136 | - | - | Rejected-Technical Technically Rejected |
| Sl No | Description | Qty | Unit | VERSHA TECHNOTRADE PVT LTD L1 |
|---|---|---|---|---|
| 1.00Financial Bid | ||||
| 1.01 | MAIN BLOCK CIVIL WORKS 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil" | 1,000 | cum | 1,000 ₹10 L |
| 1.02 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 1,674 | cum | 1,000 ₹16.7 L |
| 1.03 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 326.25 | cum | 3,000 ₹9.8 L |
| 1.04 | 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.5.3.1With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 1,050 | sqm | 300 ₹3.1 L |
| 1.05 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 147 | cum | 9,000 ₹13.2 L |
| 1.06 | 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). | 105 | sqm | 800 ₹84,000 |
| 1.07 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 240 | sqm | 1,000 ₹2.4 L |
| 1.08 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 693.34 | cum | 12,000 ₹83.2 L |
| 1.09 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 1,395.77 | cum | 11,000 ₹1.5 Cr |
Tender Value
₹23.2 Cr
EMD Value
₹46.4 L
Closing Date
25 Jul 2025, 3:00 pmClosed
Registrar, Assam Skill University
ASU Office, 3rd Floor, DECT Building, Rehabari, Guwahati-08
CONSTRUCTION OF NORTH EAST SKILL CENTRE BUILDING AT ITI GUWAHATI CAMPUS, GOPINATH NAGAR, BIRUBARI, GUWAHATI 781016
2025_SEEDE_45203_1
ASU/ASUP/291/2025/407
Open Tender
Civil Works
540 days
Birubari, Guwahati
Please refer Tender documents.
3 documents required · 3 mandatory
₹46,500
₹46.4 L
ASU Office, 3rd Floor, DECT Building, Rehabari, Gu
28 Jan 2026
27 Jun 2025
25 Jul 2025
27 Jun 2025
25 Jul 2025
22 Jul 2025
27 Jun 2025 - 2 Jul 2025
2 Jul 2025
Amount
Financial Bid
MAIN BLOCK CIVIL WORKS 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil"
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.5.3.1With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 Stairs, (excluding landings) except spiral-staircases
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22 A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.(ii)Super Ductile (SD) TMT reinforcement bars
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2Cement mortar 1:4 (1 cement :4 coarse sand)
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
8.32 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated,with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon.e sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
9.20 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.72.1 Providing and fixing bright finished brass butt hinges with necessar screws etc. complete : 125x85x5.5 mm (heavy type)
9.72.3 100x85x5.5 mm (heavy type)
9.72.5 75x65x4 mm (heavy type)
9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 200x10 mm
9.75.1 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
9.76 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
10.14 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.2 Profile C 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S tube
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.4 Ordinary cement without any pigment
11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 11.23.2 Raj Nagar plain
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size. 11.41A.1.1 Size of Tile 600 x 600 mm
11.41A.1.5Size of Tile 1000x1000 mm
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 Size of Tile 600 x 600 mm
11.56 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2110 mm diameter
12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.1 Coupler 12.42.1.2110 mm diameter
12.42.3 Single tee with door 12.42.3.2 110x110x110 mm
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board.
12.47 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.47.2 2 mm thick flat
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)
13.1.2 1:6 (1 cement: 6 fine sand)
13.2 15 mm cement plaster on rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement: 4 fine sand)
13.2.2 1:6 (1 cement: 6 fine sand)
13.41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1New work (two or more coats) over and including water thinnable priming coat with cement primer
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. 13.42.1Two or more coats on new work
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface 13.43.1 Water thinnable cement primer
13.44 Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.45 Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
20.2 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 20.2.2 500 mm dia piles
21.01 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
9.133 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 9.133.1 Tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/ sq.cm, Bending strength 100 kg/sq.cm. 9.133.1.1 10mm thick
9.166 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 9.166.1 18 mm thick
16.6 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). 16.60.1 Overhead informatory road signage
21.03 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement@ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26.86.7 Frame size 65 x 150 mm
26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30mm thick
SANITARY WORKS 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1 W.C . pan with ISI marked white solid plastic seat and lid
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includin painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
17.7.5 White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap.
17.7.6 White Vitreous China Angle back wash basin size 400 x400 mm with single 15 mm C.P. brass pillar tap
17.7.7 White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap
17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. 17.32.3 oval shape 450x350mm(outer dimensions)
17.34 Providing and fixing toilet paper holder: 17.34.1 C.P brass
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.22.1 100 mm diameter
17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
18.54 Providing and fixing PTMT bib cock of approved quality and colour. 18.54.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms
18.54.2 15 mm nominal bore, 122mm long, weighing not less than 99 gms
18.55 Providing and fixing PTMT stop cock of approved quality and colour. 18.55.1 15 mm nominal bore, 86 mm long, weighing not less than 88 gms
18.56 Providing and fixing PTMT pillar cock of approved quality and colour 18.56.1 15 mm nominal bore, 107 mm long, weighing not less than 110 gms
18.58 Providing and fixing PTMT grating of approved quality and colour. 18.52.2 Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating
17.10 Providing and fixing stainless steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets ,cuttings and making good the walls wherver required. 17.10.1 kitchen sink with drain board 17.10.1.1 510 X 1040 mm bowl depth 250mm
17.10.2 kitchen sink with out drain board 17.10.2.1 610 X 510mm bowl depth 200mm
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.1.1 32 mm dia
17.28.1.2 40 mm dia
17.28.2.1 32 mm dia
17.28.2.1 40 mm dia
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.35.1 15mm nominal bore
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.1 15 mm nominal dia Pipes
18.7.2 20 mm nominal dia Pipes
18.7.3 25 mm nominal dia Pipes
18.7.4 30 mm nominal dia Pipes
18.7.5 40 mm nominal dia Pipes
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes
18.8.2 20 mm nominal dia Pipes
18.8.3 25 mm nominal dia Pipes
18.8.4 32 mm nominal dia Pipes
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. (i) 110 mm dia
(ii) 160mm dia
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 18.17.2 32mm nominal dia pipe
18.17.4 50mm nominal dia pipe
18.17.5 65mm nominal dia pipe
18.17.6 80mm nominal dia pipe
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 18.18.2 20mm nominal dia pipe
18.18.3 25mm nominal dia pipe
18.53.A Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.19.1 25 mm nominal bore 18.19.1.1 Horizontal
18.19.1.2 Vertical
18.19.2 32 mm nominal bore 18.19.2.1 Horizontal
18.19.2.2 Vertical
18.19.3 40 mm nominal bore 18.19.3.1 Horizontal
18.19.3.2 Vertical
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 19.4.1 100x100 mm size P type 19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular)bricks of class designation 7.5
19.30 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
17.37.1 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement: 2 coarse: 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc. . a) for 100mm dia pipe.
17.38.1.2 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. a) 100mm
17.43.1.2 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100mm
17.47.1.2 Providing and fixing single unequal junction of required degree with access door, Insertion rubber washer 3 mm thick, bolts and nuts complete: 100x100x75mm
17.52.1.2 Providing and fixing single unequal plain invert branch of required degree: 100x100x75mm
17.55.1.2 Providing and fixing door plece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.) . a) 100mm
17.56.1.2 Providing and fixing cast iron terminal guard. . 100 mm
19.2.1 . Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
12.43 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.43.2 110 mm
18.10 Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal works) 18.10.1. 15mm dia nominal bore
18.10.2. 20mm dia nominal bore
18.10.3. 25mm dia nominal bore
18.10.4. 32mm dia nominal bore
18.10.5. 40mm dia nominal bore
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
32 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
65 mm nominal dia Pipes
80 mm nominal dia Pipes
100 mm nominal dia Pipes
150 mm nominal dia Pipes
17.2.6 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required
17.2.9 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required
17.2.16 Supplying, installation, testing & commissioning of addressable strobe complete as required
17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
18.1 (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 18.1.2 2850 lmp at 70 m HEAD
18.3 (A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump) (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520. (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS: 325. (D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads 18.3.1 180 lpm at 70m Head
18.4 (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520 (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 18.4.2 450 lpm at 35 m Head
18.7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings ike elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 18.7.1 25 mm dia
18.7.2 32mm dia
18.7.3 40mm dia
18.7.4 50mm dia
18.7.5 65mm dia
18.7.6 80mm dia
18.7.7 100mm dia
18.7.8 150mm dia
18.9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: 18.9.1 Single headed Gunmetal
18.11 Supplying, fixing, testing and commissioning of butterfly valve of PN1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 18.11.4 80 mm dia
18.11.5 100 mm dia
18.11.6 150 mm dia
18.11.7 200 mm dia
18.11.8 250 mm dia
18.11.9 300 mm dia
18.14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: 18.14.4 80 mm dia
18.14.5 100mm dia
18.14.6 125 mm dia
18.14.7 150mm dia
18.14.8 200mm dia
18.14.9 250mm dia
18.14.10 300mm dia
18.16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc, conforming to IS 636 (type-A) as required: 18.16.1 Gun Metal
18.17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 18.17.1 30m
18.18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe. coupling as required: 18.18.1 Gun Metal
18.19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 18.19.1 2 way-100 mm dia M.S. Pipe
18.20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
18.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
16.8 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
17.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required
18.23 Providing & fixing flow switch in following sizes M.S pipe including connection etc. as required. 18.23.2 150mm dia
18.21 Supplying, installation, testing & commissioning of 15mm dia quartzoid buld type sprinklers of rating 68 degree centigrade with required accessories: 18.21.1 pendent sprinkler
18.25 supplying ,installation,testing & commissioning of sprinkler pipe(UL LISTED) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 175 psi test pressure of 875 PSI (burst) with branch line (inlet) 25mm NPT male thread with reducer ,nipple,2 side brackets,center brackets stock bar of following sizes complete as required. 18.25.1 1000mm
Providing and fixing stored pressure ABC Fire Extinguisher consisting of welded M.S. cylinderical body, squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension braket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.(Make: Ceasefire /Steelage) Capacity 6 Kg
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal dischargetube,30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.(Make: Ceasefire /Steelage) Capacity 4.5 kg.
Providing and fixing mechanical foam type fire extingushers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose , discharge nozzle ,suspension brakcet, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.(Make: Ceasefire /Steelage) Capacity 9 kg (Pump Room & DG set)
Providing and fixing SS/ Brass ball valve full bore type tested for 20 kg/cm2 with lever and screwed female ends. (Make: Kitz / Zolloto) 25 mm dia full bore type
Supplying, installation, testing & commissioning of foor valve for all fittings 100mm
Supplying, installation, of beam detector (make honeywell /morley)
INTERNAL ELECTRICAL 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required 1.10.3 Group C
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.7 TV antenna socket outlet
1.24.8 Bell push
1.25 Supplying and fixing 2 module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27 Supplying and fixing following size/modules G.I box along with modular base & cover plate for modular switches in recess etc. as required. 1.27.1 1 or 2 module (75mm X 75mm)
1.28 Supplying and fixing following modular base & cover plate on existing modular metal boxes etc.as required 1.28.1 1 or 2 module
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep
1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.55.3 Group C
2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4 + 12), Double door
2.5.2 8 way (4 + 24), Double door
2.5.3 12 way Double door
2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.2 Double Pole
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as 2.14.1 25 A
1.8 Telephone wire Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18.1 2 Pair
2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1 100 A, 16 kA,TPMCCB
2.2.2 125 A, 16 kA,TPMCCB
14.14.1 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia
14.14.2 150 mm dia
14.14.3 250 mm dia
9.1.30 Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:- 3.5 x 300 sq.mm
9.1.29 3.5 x 240 sq.mm
9.1.27 3.5 x 185 sq.mm
9.1.26 3.5 x 150 sq.mm
9.1.25 3.5 x 120 sq.mm
9.1.24 3.5 x 95 sq.mm
9.1.23 3.5 x 70 sq.mm
9.1.22 3.5 x 50 sq.mm
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 7.1.1 Upto 35 sq. mm
7.1.2 Above 35 sq. mm and upto 95 sq. mm
7.1.3 Above 95 sq. mm and upto 185 sq. mm
7.1.4 Above 185 sq. mm and upto 400 sq. mm
7.6 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct or tray as required. 7.6.1 Upto 35 sq. mm
7.6.2 Above 35 sq. mm and upto 95 sq. mm
7.6.3 Above 95 sq. mm and upto 185 sq. mm
7.6.4 Above 185 sq. mm and upto 400 sq. mm
4.1.8 Supply and fixing of perforated 2mm thick CRCA sheet steel power coated cable tray of following sizes complete with bend/tee joints, coupling plate & nuts bolts etc. including providing and fixing of M.S. painted hanger etc. as required. 300mm wide 62.5mm depth
4.1.10 450mm wide 62.5mm depth
4.1.11 600mm wide 75mm depth
4.1.15 900mm wide 75mm depth
2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 2.15.1 25 amps
1.18 Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18.1 coaxial TV
1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.2 25mm
2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.7 TV antena Socket Outlet
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
6.8 Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. ( For vertical run )
5.2 Earthing with GI earth pipe 4-5 meterlong, 40 mm dia including accessories and providind masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required.
6.2 Providing and fixing of lightning conductor finials made of 25 mm dia 300 mm long, GI tube, having single point at the top with 85 mm dia 6 mm thick GI base plate including holes etc complete as required.
6.12 Providing and fixing testing joint, made of 20 mm x 3 mm thick GI strip, 125 mm long with 4 nos. of GI bolts, nuts, and spring washers etc as required.
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. Mm
1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in PVC conduit 1.17.11 2x2.5 sq.mm
1.17.12 4x6 sq.mm
Supply, installation, Testing & Commissioning of building Main L. T. Panel as per following technical specification and consultants drawings as per requirement and as directed by the consultant: All ACB Shall be 65kA (for incoming) & 50kA (for outgoing) with Ics=Icu=Icw=1sec. Microprocessor based for O/L, S/C, E/F with release of MTX 2.5G of 'U' Power Omega of L&T or Equivalent. All MCCB Shall be 50kA with Ics=Icu for 1 Sec. with Microprocessor Based Release for O/L, S/C & E/F with front Operated Rotary Handle Mechanism. Incoming feeders - 1 nos Bus Bar-1 Set Outgoing Feeders as follows: 1 No- ON Indicating Lamp All ACB/MCCB feeder will have microprocessor based O/L, S/C & E/F release, rotary operating handle 11 Nos - 63A 25kA FP MCCB 5Nos - 40A 10kA TP MCB 2Nos - 25A 10kA TP MCB
Supply, installation, Testing & Commissioning of Main L. T. Panel (near transformer) , suitable for installation in the outdoor, as per following technical specification and consultants drawings as per requirement and as directed by the consultant: All ACB Shall be 65kA (for incoming) & 50kA (for outgoing) with Ics=Icu=Icw=1sec. Microprocessor based for O/L, S/C, E/F with release of MTX 2.5G of 'U' Power Omega of L&T or Equivalent. All MCCB Shall be 50kA with Ics=Icu for 1 Sec. with Microprocessor Based Release for O/L, S/C & E/F with front Operated Rotary Handle Mechanism. Incoming feeders - 1 nos Bus Bar-1 Set 1 No- ON Indicating Lamp All ACB/MCCB feeder will have microprocessor based O/L, S/C & E/F release, rotary operating handle 2 Nos - 325A 36kA FP MCCB 1 Nos - 200A 36kA FP MCCB 1 Nos - 250A 36kA FP MCCB 5 Nos - 40A FP MCB 3 Nos - 63A 36kA FP MCCB
D.G. SETS Design, supply at site, installation, testing & commissioning of 3-phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 250 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure , day tank, with PCC Panel with AMF Panel,Adopter box with AL extended bus bar, battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator, pcc based auto start & synchronization set, safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722.Genset should be capable to take an average loading of minimum 85%. net output shall be designed @ 50 degree ambient .Synchronisation should be based on No Master Logic for system reliability . Any genset reaching rated RPM should automatically become master .AVR should be digital type AVR to provide fast response with respect to change in load , it should provide digital governing with digital isochronous synchronisation. To improve the reliability of the System , the synchronizing module should be part of Engine Controller . No external controller should be used for synchronising and shall not be accepted.Genset controller should have Weak Battery Monitoring system . The control system should test the battery each time the genset is signalled to start and indicate a warning if the battery is weak KVA- PHASE- Approx size- Approx Wt - COOLING 250kva DG
Supplying, assembling, fixing, testing and commissioning of following luminaires with all fixing accessories complete with necessary starters, copper wound chokes, electronic ballasts, capacitors, drivers, lamps, fitting clamps/down rods/etc, of suitable length etc. as required complete in al respect and as directed by the engineer in charge/consultant:(MAKE-Kolors or equivalent) 36 WATT LED 2X2 PANEL LIGHT
10W MIRROR LIGHT
12W LED PANEL RECESSED ROUND LIGHT
150W FLOOD LIGHT
72W STREET LIGHT
18W RECESS ROUND LIGHT
Supply, installation, testing & commissioning of 40 kVA online sine wave UPS with SMF Battery for atleast 30 Minutes Power Backup as per drawings and as required by the consultant.
Lift with Power Operated Centre Opening Doors and AC variable Voltage and Variable Frequency Controls (13-Passenger Lift )MAKE-kone or equivalent
Roof Top Solar Online grid Sytem Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
HVAC WORKS Supply of Voltas or equivalent make Variable Refigerant Flow (VRF) air- conditioning system cooling only with higly efficient DC inverter driven compressors complete with indoor and outdoor units with individual controllers and with fittings etc, as per quantity given below. The VRF can operate stably in a wide ambient temperature range: from -5°C to 55°C in cooling mode. The units are precharged with R-410A refrigerant gas, complete with duly powder coated etc as required. The outdoor unit heat exchangers have innovatively designed inner grooved type copper piping to enhance heat exchange and increase the subcooling of refrigerant to reduce system resistance and improve reliablility.The heat exchangers are specially designed for corrosion resistance with blue fin treatment. 20 HP
34 HP (22HP +12HP)
86 HP (22HP+22HP+22HP+20HP)
Supply of 4-Way Circular Air Flow Cassette Unit with 360°direction air flow , high efficient DC fan motor with seamless airflow with auto swing louver, dx copper coil, prefilter, fan section, electronic expansion valve, corded remotes etc. Minimum capacities of each Evaporative units are as follows: 0.8 TR
Supply of Refnets
ITC of Voltas or equivalent make Variable Refigerant Flow (VRF) air- conditioning system cooling only with higly efficient DC inverter driven compressors complete with indoor and outdoor units with individual controllers and with fittings etc, as per quantity given below. The VRF can operate stably in a wide ambient temperature range: from -5°C to 55°C in cooling mode. The units are precharged with R-410A refrigerant gas, complete with duly powder coated etc as required. The outdoor unit heat exchangers have innovatively designed inner grooved type copper piping to enhance heat exchange and increase the subcooling of refrigerant to reduce system resistance and improve reliablility.The heat exchangers are specially designed for corrosion resistance with blue fin treatment. 20 HP
34 HP (22HP +12HP)
96 HP (22HP+22HP+22HP+30HP)
ITC of 4-Way Circular Air Flow Cassette Unit with 360°direction air flow , high efficient DC fan motor with seamless airflow with auto swing louver, dx copper coil, prefilter, fan section, electronic expansion valve, corded remotes etc. Minimum capacities of each Evaporative units are as follows: 0.8 TR
ITC of Refnets
Lifting & Shifting of ODU from Ground Level to terrace Level or as per site requirement
Refrigerant piping and piping accessories. Supply, Installation and Testing of Hard/soft Copper refrigerant piping of required sizes for suction & liquid, with Superlon/Accoflex insulation material for the gas/liquid line. All the copper piping covered with Insulation as per specifications
Control cabling Supply, Installation and Testing of Control cabling with copper conductor min. 2 core x 1.5 sq.mm. cable with end termination for Indoor units enclosed in PVC Conduit
Drain Piping Supply, Installation and Testing of Drain piping in hard cPVC with all fittings, properly insulated with nitrile rubber, supports and clamps, including drilling hole in wall to route the drain pipe
Refrigerant Gas Top-up required Supply and Charging of extra Gas required for all the above units as per Copper Piping length and the Indoor unit capacity (With R410A Gas)
Supply, installation, testing and comissioning of wall Louvers with damper suitable for Fresh Air 350x300 mm
SITC of Inline fans ( with necessory supports arrangement) complete with 1Ph/3 Ph motor, frame for fixing, impeller, outlet cowl piece with protective wire mesh etc. . Power cabling from this switch socket to fans shall be included in the unit rates.Capacities shall be as under. CAPACITY-1100 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-600 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-370 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-300 CFM (Fresh Air Fan ) ESP-25mmwc
CAPACITY-250 CFM (Fresh Air Fan ) ESP-25mmwc
SITC of Flexible Duct
Site Development 2.25(a)Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. Internal work - Exposed on wall
16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
16.9 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
16.38 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
MAIN GATE 2.80 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. (ii)Super Ductile (SD) TMT reinforcement bars
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
13.1 12 mm cement plaster of mix :
13.2 15 mm cement plaster on rough side of single or half brick wall of mix: 13.2.2 1:6 (1 cement: 6 fine sand)
13.3.4. Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
LANDSCAPING 2.57 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) 2.57.1 Trees Plant
2.57.2 Shrubs Plant
2.57.3 Hedge Plant /Ground cover
4.4 Providing and Displaying Marigold(Tagetes) inca hybrid different colour having 30 cm and above ht., with 6 to 8 flowers in bloom & blooming condition, well developed pot should be fully covered with fresh and healthy, foliage and flowers in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
7.5 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
9.4 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring,Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, PeruvianaOdissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge
Septic Tank (100 users) 2.80 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
5.9 Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 5.9.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
5.9.3 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6.4.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side (b) In cement mortar 1:4
5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15mm thick
COMPOUND WALL 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil
2.25 (a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. (ii)Super Ductile (SD) TMT reinforcement bars
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
13.1 12 mm cement plaster of mix : 13.1.2 1:6 (1 cement: 6 fine sand)
13.2 15 mm cement plaster on rough side of single or half brick wall of mix: 13.2.2 1:6 (1 cement: 6 fine sand)
13.3.4 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
16.15.1 R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-incharge (cost of earth works in excavation, concrete works in foundation to be paid separately).
16.15.2 Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamelpaint of approved shade over a coat of primer (Priming &Painting to be paid for separately).
16.19 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
(N/S)FURNITURE FOR LECTURE HALL (300 NO'S) Make: Featherlite or equivalent as approved by Department
(N/S)ACOUSTICS, SOUND SYSTEM, & VIDEO SYSTEM Underdeck Insulation:- Supply and installation of Underdeck Insulation as follows:- Layer 1:- 75mm X 75mm GI Wire Mesh tied to the Purlin by using 18G GI Binding Wire. Layer 2:- Single layer Bubble sheet with both side high resistance aluminium foel. Bubble Sheet Thickness:- 4MM, Reflectivity:- 97%, R Value 3.10 MK, Fire Rating:- as per Standard Class 1 BS 476, Flame Spread Classification and Smoke Density:- Class A (UL 723, NFPA No. 255, UBC No. 8-1) Layer 3:- 1 layer of 50MM thick 48KG Density Glass fiber Wool to be used as Noise barrier and thermal insulation. The Insulation to be completed including taping/stapling the joints of Glass Fiber Wools to provide a vapour barrier against condensation and to be in close contact with metal roofing. The entire work shall be done as per drawings and directions.
Wall Upper Portion:- Supply and installation of Fabric Covered wood wool panel of size 1200 x 600 x 20mm mounted on supplied G I Frame work consisting of basic profile, main profile & edge profile. Frame work consists of 25mm thick GI wall channels with fully knurled surface of 0.55mm thick 80mm width, having two equal flanges of 26mm. A GI wall channel is fixed to the walls in horizontal direction with the help of suitable fastners at 600mm C/C then an another 25mm thick GI wall channel is fixed vertically over the horizontlly laid wall channel at 600mm C/C . The frame work shall wood wool panel will be back lined by using 50MM polyester wool having a density of 1000 GSM and 50mm thick.
Wall Lower Portion:- Supply and Installation of Wooden Slats made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated slats L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centers), backlined with Soundtexblack acoustical fleece, tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128x2440x16mm, volume density of base board 800Kg/m3, weight 8Kgs/m2 (L16), 10.5Kgs/m2 (L32), to be backined by using 1000 gsm 50 mm thick polyester fibre Wool.
Stage Side & Rear Wall:- Supply and installation of Fine wood wool panel ,factory painted of size 600 x 600 x 15mm mounted on proprietory supplied G I Frame work consisting of basic profile, main profile,edge profile and spacer. The Woodwool panels are backlined with 50mm thick 1000GSM Polyester Wool and Painted with approved colour.
Micro Perforated Gypsum Ceiling:- Supply and installation of 12.5 mm thick Micro perforated Gypsum Plaster Board of 3.5 mm square perforations (minimum 13% of perforated area) backed with 50mm thick approved 1000 GSM polyester wool. Framework shall consists of GI perimeter channels (having one flange and another flange) fixed along with perimeter of the beam or walls with the help of nylon sleeves and screws at 600mm c/c. Final finishing is done with two coats of acrylic emulsion paint of approved colour as directed by the Engineer-in-charge.
Stage Flooring:- Providing and fixing of 8MM Wooden Laminate Flooring of approved shade or texture, or combination thereof) as required at all levels in floors, risers and treads backlined with 2MM Foam to be fixed on surface of the Stage Floor
FOH Array Speaker Supply, Installation, Testing and Commissoning of Powered, digitally steerable multi-channel, column array loudspeaker; Frequency Range 130 Hz - 20 kHz; Maximum SPL @ 100 ft (30 m)*; Sample Rate 96 kHz. (Make:- Tannoy/ Renkus Heinz/ Turbosound)
Supply, Installation, Testing and Commissoning of USB RS232 rack- mountable interface for connecting a Windows PC running VNET Software to any VNET loudspeaker network, allowing full control, tuning and diagnostics of the devices in the network (Make: Tannoy/ Renkus Heinz/ Turbosound)
Subwoofer System Supply, Installation, Testing and Commissoning of 1,000 Watts continuous, 4,000 Watts peak power;18" Direct Radiating Passive Subwoofer; Frequency Response (-3 dB) (1) 40 Hz - 3 kHz; Rated Maximum SPL (2) Average: 129 dB; Nominal Impedance 8 Ohms (Make:- Tannoy/ Renkus Heinz/ Turbosound)
Supply, Installation, Testing and Commissoning of 7,000 Watt 2-Channel Amplifier with NomadLink Network Monitoring and Dedicated Control; 2 x 3,500 Watts into 2 Ohms, 2 x 2,800 Watts into 4 Ohms, 2 x 1,450 Watts into 8 Ohms, 2 x 730 Watts into 16 Ohms (Make:- Labgruppen/ Powersoft/ Procella)
Supply, Installation, Testing and Commissoning of 6" Dual Concentric Surface-Mount Loudspeaker, 80 W @ 16 Ohms, 70 V/100 V: 60 W / 30 W / 15 W,IP65 rating ,Yoke bracket included (Make:- Tannoy/ Renkus Heinz/ Turbosound)
Supply, Installation, Testing and Commissoning of Compact 2 x 60 Watt Amplifier. (Make:- Labgruppen/ Powersoft/ Procella)
Supply, Installation, Testing and Commissoning of 1100 Watt 2 Way 15" Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology;1" High Temperature Dome Compression Driver With Extended High Frequency Reproduction (Make:- Tannoy/ Renkus Heinz/ Turbosound)
Supply, Installation, Testing and Commissioning of 32-channel Audio Mixing Console. Precision equalization circuitry, True 7-bus architecture, 2 stereo inputs 2 stereo returns, Channel direct outputs, 6 aux sends, 4 of which are pre/post switchable, Integral universal voltage, switched-mode PSU for light weight Talkback facility, 100mm faders, +48 phantom power (Make:- Behringer/ Yamaha/ Soundcraft)
Supply and Installation of Reverb Interface (Make:- Behringer/ Yamaha/ Soundcraft)
Supply and Installation of Delay Interface (Make:- Behringer/ Yamaha/ Soundcraft)
Supply, Installation, Testing and Commissoning of Gooseneck Microphone With Cardioid Directivity Microphone Capsule and Table top Base for Gooseneck Microphone. (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissoning of Wireless Vocal Hand Held Microphone Set With Dynamic Cardioid Microphone Capsule; Enhanced Frequency Bank System With Up To 12 Compatible Frequencies; Frequency Response 80Hz - 180KHz; AF Sensitivity 2,5 mV/Pa. (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissoning of Wired,Dynamic Super- cardioid Microphone For Speech And Vocals With Noiseless On/Off Switch. (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissoning of Cardioid Dynamic Instrument Microphone Specifically Designed For Drum Applications. Featuring A Very Short Body With Integrated Stand Mount And A Aniversal Rim Clip; Frequency Response 40Kz - 18KHz. (Make:- Sennheiser/ Audio Technica/ Shure)
Supply, Installation, Testing and Commissoning of Long Microphone Stand (Make:- MX/ Ahuja/ Softline)
Supply and Laying of High Flexible Speaker Cable For Power Amplifiers Up To 4000 Watts. 224 Strands Of 0.15 mm Bare Cupper Wires. (Make:- Belden/ Gotham/ Klotz)
Supply and Laying of High flexible Speaker cable for power amplifiers upto minimum 500 Watt , Jacket - PVC, ø 0.32 in, black Conductor - Stranded bare copper wires, 140x35 AWG (13AWG) , (Make:- Belden/ Gotham/ Klotz)
Supply and Laying of Audio Signal Cable;Balanced microphone cable with single shield, high flexible, velvet faint PVC-Jacket , Conductor: Stranded bare copper wires 28 x 0.10 mm (0.22mm²) , Jacket: PVC, 6.0 mm max. Ø (Make:- Belden/ Gotham/ Klotz)
Supply and Installation of Stage Box With 8 x XLR Connector (Make:- Neutrik/ Amphenol/ MX)
Supply and Laying of 8 Channel Snake Cable (Make:- Belden/ Gotham/ Klotz)
Supply and Laying of CAT6 Cable (Make: Dlink/ Molex/ Netgear)
Supply and Installation of XLR connectors Male (Make:- Neutrik/ Amphneol/ Gotham)
Supply and Installation of XLR connectors Female (Make:- Neutrik/ Amphneol/ Gotham)
Supply and Installation of 1/8" (3.5mm) Balanced Phono Plug (Make:- Neutrik/ Amphneol/ Gotham)
Supply and Installation of 1/4"Unbalanced Phono Plug (Make:- Neutrik/ Amphneol/ Gotham)
Supply and Installation of Speakon connectors (Make:- Neutrik/ Amphneol/ Gotham)
Supply and Installation of 24 U Equipment Rack (Make:- Valrack/ Nettrack/ LinkEu)
Supply, Installation, Testing and Commissioning of Active LED Wall ,Pixel Pitch : 2.5mm, Proposed Size (WxH) : 3.84 x 2.16 m, Cabinet Size (WxH) : 960 x 270 mm, Total Cabinet (WxH) :4 x 8 = 32 , Module (WxH) : 4 x 1= 4, Diagonal Size Inches : 173, Brightness : 800 Cd/m2, Accessibility : Front Access, Total Resolution : 1536x864 , with inbuilt controller, Wall mount bracket and installation included. It is inclusive of Wooden Background. (Make:- Panasonic/ Christie/ Barco)
Supplying installation, testing, programming and commissioning of Video equipment HDMI HDBaseT Extender (4K@100m) (HDBaseT Class A): Video Input Interfaces 1 x HDMI Type A Female (Black), Max. Distance 1.8 m, Video Output Interfaces 1 x HDMI Type A Female (Black), Video Max. Data Rate 10.2 Gbps (3.4 Gbps Per Lane) 10.2 Gbps (3.4 Gbps Per Lane), Max. Pixel Clock Up to 340 MHz Up to 340 MHz, Compliance HDMI (3D, Deep Color, 4K) HDCP Compatible, Max. Resolutions / Distance Up to 4K@70m (Cat 5e/6) / 100m (Cat 6a), 1080p@100m, 4K supported: 4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0), 4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4) (Make:- Kramer/ Purelink/ Atlona)
Supplying installation, testing, programming and commissioning of Video equipment 4-Port 4K HDMI Switch (Make:- Kramer/ Purelink/ Atlona)
Supply, Installation, Testing and Commissioning of AI Auto-Tracking Camera. AI-Powered Human Detection 3 Tracking modes and 2 Framing modes Mount upright or inverted HDMI, Ethernet, 3G-SDI and USB simultaneous output 1080p 60fps with 20x Optical Zoom (Make: Lumens/ Sony/ Vaddio)
Supply, Installation, Testing and Commissioning of 2CH HD Recorder and Streaming Media Processor. 2-Channel AV Source Processing Simultaneous Recording and Streaming HDMI, SDI, RTSP, USB source inputs XLR with Phantom power supported Built-in 2TB HDD storage* (Make: Lumens/ Sony/ Vaddio
Supply, Installation, Testing and Commissioning of E Podium having Monitor Size:- 21.5", Resolution:- 1080p, Brightness:- 250 cd/m2. (Make:- Peoplelink/ Aha/ Uni)
Supply and Installation of HDMI Wall Plates (Make:- Kramer/ Purelink/ Atlona)
Supply and Installation of HDMi to HDMI Cables of Length 1 Mtr (Make:- Kramer/ Purelink/ Atlona)
Supply and Installation of HDMi to HDMI Cables of Length 15 Mtr (Make:- Kramer/ Purelink/ Atlona)
Supply of Led par Light source:54PCS 3W LEDs(R12 G12 B12 W18) 2. Lens angle: 25°(30°, 45°, 60°optional) 3. Channel mode:3 / 4 / 6 / 7 / 9DMX channel mode 4. 0-100% linear dimmer 5. Function: color mix, automatic color change, built-in program and strobe effect with adjustable speed. 6. Sound controlled via built-in microphone 7. Adjustable sound sensitivity 8. LED Display, easy to control 9. Control: auto, sound active, DMX512, software(connect to computer) 10. Overheating protection 11. Voltage:100- 220V,50/60hz 12. Power:180W13. IP rating:IP20 (DLMS/ PLS/ Effectron)
Supply of Indoor LED par 54 LED Par 200w, voltage-110v-250v/50- 60HZ,lamp-TX high power LEDS; 3w x54 LED, 4 in 1 LED working position; any safe working position LED display,channel-4/5/7 CHS,Beam Angle- 15/25/45/600 ,IP Grad-IP20,control mode- master/slave synchronization, DMX-512 control and auto matic run funcation,construcation-Aluminium and plastic body,silver,white and black optional (DLMC/ETC/CANARA)
Supply of Profile spot 750W 19º, 26º, 36º, 50º field angles Faceted reflector removes 90% of IR heat from its beam Four stainless-steel shutter blades assembly Rugged and graceful die-cast aluminum construction Power : 220v/50Hz Lamp : 220v HPL750w G9.5 Color temperature : 3200k Weight: 6kg (DLMC/ETC/Canara
Supply of LED Blinder 400w Supply of LED blinder Specification Model : 4 Eyes Blinder COB Matrix blinder audience cob LED light, 4* 100W 3200K party event equipment 1.Light Source : 4 pcs 100/100W warm white or cool white or cool white + warm white 2in 1 or white + yellow 2 in 1.Voltage : AC90V - 245V Frequency : 50-60Hz Power Consumption : 450W Light Color : White or warm White LED Control : Individual Controllable Lifetime : 60,000 hours DMX Channel : 6/12/2CH Color Temp : 2500K /3200K / 6500K Warm White : 5600K - 6400K Cool White : 2800K - 3200K Dimmer :0~100% Linear Adjustable Beam Angle : 38 Degree Working Temperature : -30°C~50°C Control Mode : DMX512, Master / Salve, Auto Run, Stand alone,Sound Active Strobe Effect : Variable Speed (1-30Hz) House Material : Matel House Color : Black IP Grade : IP20 Weight : 5.5 kg (PLS led blinder 4way)
Supply of Light Controller Computer Light Controller,Product Model:Mini Pearl Voltage 100 to 240 V Frequency 50/60 Hz Mating number of Fixtures 96 The Number of Scenes That Can be Saved 60 The Number of Scenes That Can Run Simultaneously 10 The Total Number of Steps in a Multi Step Scenario 600 Scene Time Control Fade In, Fade Out LTP Sliding Graphics Can be Stored for Each Scene 5 Fader Scenes/Dimming Size 485 x 420 x 105 cmProduct Description Leveraging the skills of our qualified team of professionals, we are instrumental in offering a wide range of Mini Pearl 1024 Lighting Controller. (PLS- MINI PEARL-1024)
Supply of 1.5sqmm 3 core shilded wire (National/Incol/Polycab)
Supply of Cable Tray 40 x100 x16swg painted.(Customised)
Supply of Light socket box 4"x4" with 15 Amp multi socket (Anchor/Dimond (Customised)
Supply of Side Light Ladder of 25mm x 50mm M.S.tube size (6'x2') cusrtomised
Supply of 50mm OD G I Pipe B.Class for lighting grid & lighting bar to be hang from top with support of 40x40x5mm M.S.Angle. (Make:-JINDAL/TATA/)
Supply of DMX Splitter 1 in 10 out The XLR connectors are mounted directly on the board.2. Connectors can be on the front or on the back. 3. Daisy chain of the input signal.4. Switch for DMX line termination.5. In 1 to 10 unit, (MAKE PLS-SPL-10)/ETC/Canara
Supply of DMX cable 20/0.12BC+PE1.8, for stage to control room (PLS/FBT/TASKER)
Supply of customised MCB box with 16 Amp 18nos MCB & 1 Nos 4 pole Isolater 125amp having facility to connect the 18 nos,light point, (customised)
Supply of DMX point box (customised) Tasker/Neutrik/PLS
Supply and Installation of 20KVA Online UPS System with isolation transformer, Battery Bank for 30 Min Back up and Interconnectos
FLOORING FOR FACILITY TRAINING ROOM 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 11.23.2 Raj Nagar plain
11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
11.33 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : 11.33.2 Second class deodar wood
(N/S) CARPET FLOORING
(N/S) VINYL FLOORING
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid