| Sl No | Description | Qty | Unit | Swarnendu Sarkar L2 | APU ELECTRIC L3 | TITHI ELECTRONICS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of 230V, 50Hz 2.0 ton capacity(minimum); Minimun ISEER rating: 3 or above, split A.C. machine fitted with fixed speed rotary compressors with copper made cooling coil, Material for body of indoor unit ABS, nominal cooling capacity: (KCAL/Hr.) : 7020, Min. guaranteed cooling capacity (KCAL/Hr.) :6500, Moisture removal capacity, Minimum room discharge Air Flow (CUM/Hr.) : 700, with Remote etc . Model No-ASGA24BUTA-B (R32), ( Make: O General / Mitshubisi Electric/ Daikin ) (as per direction of EIC)
(price includes supply of standard complete set of installation kit (OEM make only) for 3 mtr. running distance and all type of interconnection) (Machine Warranty 1 year and compressor & PCB warrenty min 5 years ) | 2 | Each | 79,800 ₹1,59,600 | 79,850 ₹1,59,700 | 79,700 ₹1,59,400 Lowest |
| 2.00 | Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC. | 2 | Each | 2,330 ₹4,660 | 2,335 ₹4,670 | 2,320 ₹4,640 Lowest |
| 3.00 | S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam both for suction & discharge pipe and mending good the holes & damages as directed by EIC.
(extra length for distance of ODU & IDU exceed 3 mtr.) | 30 | Mtr | 635 ₹19,050 | 635 ₹19,050 | 625 ₹18,750 Lowest |
| 4.00 | S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) | 30 | Mtr | 400 ₹12,000 | 410 ₹12,300 | 390 ₹11,700 Lowest |
| 5.00 | S & F of flexible PVC high quality water carrying pipe of 180 mm dia size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. | 20 | Mtr | 120 ₹2,400 | 115 ₹2,300 | 100 ₹2,000 Lowest |
| 6.00 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schindler/ ABB ] 100 A FP | 1 | No | 1,159 ₹1,159 Lowest | 1,159 ₹1,159 Lowest | 1,159 ₹1,159 Lowest |
| 7.00 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/ Schindler/ABB] 6-32 SP | 2 | No | 240 ₹480 | 238 ₹476 Lowest | 238 ₹476 Lowest |
| 8.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required as per GS 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 20 | Mtr | 200 ₹4,000 | 195 ₹3,900 | 180 ₹3,600 Lowest |
| 9.00 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per GS | 1 | Each | 985 ₹985 | 980 ₹980 Lowest | 980 ₹980 Lowest |
| 10.00 | S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S. | 1 | Each | 710 ₹710 | 700 ₹700 Lowest | 700 ₹700 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,080
Closing Date
3 Jul 2026, 12:30 pmClosed
AE/BESD
OFFICE OF THE ASSISTANT ENGINEER Bishnupur Electrical Sub-Division, PWDte P.O - Bishnupur, Dist.- Bankura , Pin-722122
SITC of split AC machine including necessary Electrical Installation work at the Bill Section of the Bishnupur Division office and office establishment of the Bishnupur Sub Division Office, PWD.
2026_WBPWD_5015885_1
WBPWDTE/AE/BESD/e-NIQ 03 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Bishnupur
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,080
21 Sept 2026
23 Jun 2026
6 Jul 2026
23 Jun 2026
3 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Delivery of 230V, 50Hz 2.0 ton capacity(minimum); Minimun ISEER rating: 3 or above, split A.C. machine fitted with fixed speed rotary compressors with copper made cooling coil, Material for body of indoor unit ABS, nominal cooling capacity: (KCAL/Hr.) : 7020, Min. guaranteed cooling capacity (KCAL/Hr.) :6500, Moisture removal capacity, Minimum room discharge Air Flow (CUM/Hr.) : 700, with Remote etc . Model No-ASGA24BUTA-B (R32), ( Make: O General / Mitshubisi Electric/ Daikin ) (as per direction of EIC)
(price includes supply of standard complete set of installation kit (OEM make only) for 3 mtr. running distance and all type of interconnection) (Machine Warranty 1 year and compressor & PCB warrenty min 5 years ) | 2 | Each | - | - |
| 2 | Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC. | 2 | Each | - | - |
| 3 | S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam both for suction & discharge pipe and mending good the holes & damages as directed by EIC.
(extra length for distance of ODU & IDU exceed 3 mtr.) | 30 | Mtr | - | - |
| 4 | S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) | 30 | Mtr | - | - |
| 5 | S & F of flexible PVC high quality water carrying pipe of 180 mm dia size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. | 20 | Mtr | - | - |
| 6 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schindler/ ABB ] 100 A FP | 1 | No | - | - |
| 7 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/ Schindler/ABB] 6-32 SP | 2 | No | - | - |
| 8 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required as per GS 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 20 | Mtr | - | - |
| 9 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per GS | 1 | Each | - | - |
| 10 | S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S. | 1 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
NIQ03.pdf
Tender Documents • 0.96 MB
2911.pdf
Other Document • 0.53 MB
BOQ_5084935.xls
BOQ • 0.28 MB
OID.pdf
Additional Documents • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .