Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC ALIPURDUAR ALIPURDUAR WEST BENGAL | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹7.4 L+₹1.0 L (16.3%)Rejected-Finance BELTALA ALIPURDUAR | ALIPURDUAR | COOCH BEHAR | WEST BENGAL | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹9.2 L+₹2.8 L (44.7%)Rejected-Finance COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L3 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹15,720
Closing Date
4 Mar 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Construction of Proposed Nursing Training School G.N.M at Alipurduar District Hospital Internal and External Electrical Installation Work S.I.T.C of Compound Illumination and additional Fittings Fixtures
2021_WBPWD_328284_1
WBPWD/SENBEC/NIT-64/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Alipurduar District Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,720
6 Sept 2021
22 Feb 2021
8 Mar 2021
22 Feb 2021
4 Mar 2021
26 Feb 2021
120 days
Amount
SUB-HEAD 1--DISTRIBUTION WIRING
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 19mm bore 3mm thick polythin pipe complete with all accessories embeded in wall to to light/fan/call bell points with Modular type switch fixed on Modular GI switch board with top cover plate flushed in wall flushed in wall incl mending good damages. [ As per approved list of Material ]
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
(a) 13 mm dia 3 mm thick polythene pipe without earth continuity wire.
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
(a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
(a) 3x(1.5 sqmm) [ for 6 A seperate plug ]
(b) 2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug, Computer Board ]
(c) 2x(4 sqmm)+1x (2.5 sqmm)[ For RAC ]
SUB-HEAD 2--BDB,PDB,VTPN ETC
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
(a) 2+12 Way [ Legrand ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
(a) 6 Way (Legrand)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
(a) 40 A DP (Legrand)
(b) 63 A FP (Legrand)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
(a) 6-32 SP (Legrand)
SUB-HEAD 3 - SUPPLY & FIXING OF LIGHT FITTINGS
Supply & Delivery Single LED T8 T/L fittings (Philips TMC 501 P 1xT-LED 22W P3241) incl. 1x MAS LED tube 1200mm 18W865 T8 I--2100lm) or Equivalent product of Crompton /Wipro having similar specification in all respect
Supply& Delivery Twin LED T8 T/L fittings( Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LEDtube 1200mm 18W865 T8 I --2100 lm.) or Equivalent product of Crompton /Wipro having similar specification in all respect
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing of road lighting luminaire (IP 66) with Single Die ceramic base high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and Initial luminous flux - 15000 Lm , Maximum Initial input power - 120 W, Minimum Initial LED luminaire efficiency - 125 lm/w , CCT- 5000-6000 K suitable for use with 230 Volt 50 Hz AC supply etc as required. (Make - Philips-BRP 340 LED 150 CW HO SLC S2 PSU GR or Equivalent product of Crompton /Wipro having similar specification in all respect
SUB-HEAD 4 -- FIXING OF FANS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
SUB-HEAD 5 -- SUPPLY OF FANS
Supply & delivery of 250 volt. 56" (1400 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make - Crompton HB+ or HS+/Orient Energy star/Usha Striker/Make of Similar specification As per Approved Make List]
SUB-HEAD 6 -- SUPPLY & LAYING OF CABLE
Supply & Delivery of XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984/ 3975:1970 /8130:1984/ 3961:1967/10418:1982/ 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith: [Nicco / Gloster/Polycab/Havells/RR Kabel/Crystal]
(a) 4 Core 10 Sq.mm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
(a) 4 Core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
SUB-HEAD 7 -- EARTHING
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS
For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
(a) TATA-Medium GI pipe (for 10 Nos Pole & others)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (a) solid GI wire
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
SUB-HEAD 8 -- SUPPLY & ERECTION OF POLE
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- ( Make : Bajaj/ Philips/ Valmont/ CG/ Transrail/Bansal/ Utkarsh ).
(i) 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -130 mm ] Base Plate Size : 220 mm x 220mm x 12 mm..
Errection of the above Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth.
(i) 7 Mtr Long [ Founation size - 500 mm X 500 mm X 1400 mm, J Bolt Size - Dia 20mm Length 700mm ]
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 1 M length complete with all fixing arrangements as required including painting
Single Arm
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
DAS ELECTRICAL ENGINEERING CO
DIAMOND ELECTRICAL WORKS
stage.html
html • 0.05 MB
technical_624926.pdf
PDF • 0.07 MB
techsummary_624926.pdf
PDF • 0.09 MB
finance_624926.pdf
PDF • 0.06 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_624926.pdf
PDF • 0.08 MB
AOC64.pdf
PDF • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .