Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | Admitted-Finance |
| 3 | Admitted-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | Admitted-Finance |
Tender Value
₹26 L
EMD Value
₹26,000
Closing Date
23 Dec 2023, 5:20 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MEERUT
130 D PAARESHAN BHAWAN VICTORIA PARK MEERUT
WORK TENDER
2023_UPTCL_871951_1
T-32/23-24/ETC/MT
Open Tender
Electrical Works
Item Rate
90 days
MEERUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
SE ETC MEERUT
₹26,000
16 Jan 2024
18 Dec 2023
23 Dec 2023
18 Dec 2023
23 Dec 2023
18 Dec 2023
Amount
Work Portion: -
Dismantalling of Main Structure of 63 MVA T/F - II jack bus reuired for modification in existing Jack Bus at Sub-station for adding 40 MVA Transformer.
Installation & Extension of 132 KV Main & Transfer Bays
Erection of Main & Auxiliary Sub-Station Structure for 40 MVA Transformer Bay and Extension of 132 KV Main & Transfer Bays
Erection of Main & Auxiliary structure lattice type ATM, ABL, BCT, ALP, BPL etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of isolator, CTs, PTs, LA etc. erection of structure as per drawing with the help of GI nuts & Bolts flat spring washer matching the hole, cutting and matching the member if required include cost of all men and T & P excluding GI structure nut and bolts to complete the work erection of main & auxiliary structure lattice type ATM, BTM, AXM, ABL, CCM,CGM, EKR, BBR, BCT, ALP, BPL, BTI etc. upon foundation and its proper tightening.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
145 KV Circuit Breaker
36 KV Vacuum Circuit Breaker
145 KV Current Transformer
36 KV Current Transformer
145 KV CT junction box.
36 KV CT junction box.
145 KV Bus Isolator
145 KV Tandom Isolator without earth switch (Non-Motorized)
145 KV Bus Post Insulator
36 KV Bus Isolator
120 KV Lighting Arrestors
30 KV Lighting Arrestors(3 Nos for T/F and 6 Nos for Bus)
36 KV PT (For 33 KV Bus)
36 KV PT junction box.
Erection of following control and relay Panels as per instruction manual and technical specification including shifting of panel from store to erection site including all other associated works to complete the job satisfactorily.
132 KV control relay panel for 40 MVA Transformer.
40 MVA RTCC Panel.
Jumpering of 132 KV & 33 KV Equipment with Main /Transfer / jack Bus bar of ACSR Zebra /Panther conductor. The work Includes cutting of conductor. Bending in proper shape .clamping with the help of clamp and all other associated work to complete job.
40 MVA Transformer Bay 132 KV side with Panther Conductor
33 KV side Transformer bay Twin Moose
Laying of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
Control cable of size 2 core x 2.5 mm2
Control cable of size 4 core x 2.5 mm2
Control cable of size 6 core x 2.5 mm2
Termination of cable laid as as per cable schedule including making necessary hole in laid plates or box wherever required, fixing cable glands of appropriate size and ferruling of each core and other associated work to complete the job satisfactroly. Rates of termination of control cables including the all cores of cable and one end with lugs.
Erection of 40 MVA Transformer
Shifting of main tank of 40 MVA Transformer from unloading point to the plinth up to 30 Mtr distance including turning of tank if required including all T & P and labour required to complete the job satisfactorily.
Complete erection of 40 MVA 132/33 KV Transformer by erection of radiator, conservator t ank all bushing oil pipe lines, cooling fans etc. to complete the job satisfactorily.
Replacement of Gasket of radiator/Bushing/ Pipe line only open part except top cover of Transformer by providing and fixing of new gasket as per existing size made of rubberized cork sheet Kotika/Turborze brand grade.
Circulation of complete Transformer oil in Transformer tank through centrifuging machine, centrifuging machine shall be provided by the contractor, oil capacity (Approx 20 KL)
Ring Earthing of Lightening Arrester with 3.0 Mtr long 06 Nos. electrodes of 40 mm M.S. Round Bar having 150 mm long conical shape placing these inside the ground in rectangular shape and connected the electrodes with 75x10 M.S Flats including all associated works.Work includes fabrication of 06 nos. 3 mtr long electrodes with 40 mm dia MS Rod bar having 150 mm long conical shape. Notes :- MS Round Bar & M.S. Flat Shall be provided by Department.
120 KV Lighetening Arrester
30 KV Lighetening Arrester
Delta earthig of HV & LV side neutrals of 40 MVA Transformers by 3 Nos., 3.0 Mtr long electrode of 40 mm M.S. Round Bar having 150 mm long conical shape, placing inside the ground in triangular shape and connection all 3 Nos electrodes with 75x10/50x6mm MS flats then connect this triangle shape with X & Y of main earth mat of Sub-Station as per drawing. Notes :- MS Round Bar & M.S. Flat Shall be provided by Department.
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling including painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work All other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Extension of existing earthmat for earthing of main and auxiliary structure for extention of 132 Main and Transfer bus and for construction of HV bay of additional 40 MVA Trafo work includes insertion of 40 mm MS electrodes as per requirement .
Laying 40 mm MS Round 1 Bar meter below ground level including cutting straightening welding painting of joints excavation of treanch its back filling and all other associated work to complete the job .
Fabrication of 3 Meter long electrodes with following MS Rod having 150 mm long conical shape and then its placing vertically inside the ground with 700mm below ground level including cutting turning and machining of electrode.
Making cross joint of above laid 40mm dia MS Round bar 700mm below the ground level by due welding at all 4 corners including welding of suitable size 2 Nos MS angle Pieces on opposite corner of the cross joint,
Making of end joint of above laid 40 mm dia MS round bar with top of the already vertically pierced MS electrode 700 mm below the ground level by due welding.
Making of the 300 mm long lap joint of above already laid round bar to connecting existing earth mat of the substation.
Strengthening of 132 KV Main and Transfer Bus
Opening of existing Jumpers from 132 KV Main Bus Bar and from 132 KV Bus Isolator clamps of all 132 KV Bays
Opening of existing Jumpers from 132 KV Jack Bus and Bushing of 63 MVA Transformer-II and 132 KV LA
Dismantling of 132 KV old main bus bar section (R, Y & B phase) Zebra conductor and lowering down of conductor from sub-station gantry to complete dismantling works including dismantling of all associated tension clamps, fittings & disc insulators etc. (03 Phase of one section= 01 Job) of 1x1Z of 36 Mtrs & 1x1Z of 12 Mtrs
1x1Z of 36 Mtrs
1X1Z of 12 Mtrs
Stringing of 132 KV Twin moose main bus with all 3 phases. The work includes cutting & bending of conductor, fixing of bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification. (03 Phase of one section= 01 Job)
1x2M of 36 Mtrs
1X2M of 12 Mtrs
Stringing of 132 KV Single moose for extension of 132 KV Transfer Bus with all 3 phases. The work includes cutting & bending of conductor, fixing of bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification. (03 Phase of one section= 01 Job)
1x1M of 12 Mtrs
Stringing of 132 KV Single panther jack bus with all 3 phases. The work includes cutting & bending of conductor, fixing of bolted type tension/suspension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification. (03 Phase of one section= 01 Job)
1x1P of 12 Mtrs
1x1P of 18Mtrs
1x1P of 24 Mtrs
1x1P of 36 Mtrs
Jumpering of 132 KV Equipment, jumper from main bus/Transfer to 132 KV switchgear with Twin Panther.
Jumpering of 132 KV Equipment, jumper from Transfer bus to 132 KV switchgear/Isolator, with panther conductor
Jumpering of 132 KV Equipment, jumper from Jack bus of 63 MVA transformer-II to HV Bushing of Transformer and 120 KV LA with panther conductor
Strenthening of 33 KV Main Bus
Dismantling of 33 KV Old/ Damaged Main bus bar Sections (R, Y, & B) of Single Tarantula conductor and lowering down of conductor from sub-station gantry to complete dismantling work including dismantling of all associated Tension clamps, fittings & Disc insulators etc. (03 Phase of one section= 01 Job) 2x1T of 24 Mtrs & 1x1T of 12 mtrs
1x1T of 24 Mtrs
1x1T of 12 Mtrs
Opening/Dismantling of Jumpers of 33 KV Equipment, jumper from main bus to 33 KV switchgear, Moose/Panther conductor.
Dismantling of Jumpering of 33 KV Equipment, jumper from Main bus to Section Isolator, Moose/Zebra conductor.
Stringing and proper sagging of new 33 KV Main bus bar Sections (R, Y & B) by Twin Tarantula conductor the work includes fitting of tension clamps, Hoisting of 70 KN Disc, tension fittings, Spacers PG Clamps etc. and cutting of conductor as required. (03 Phase of one section= 01 Job) 2x2T of 24 Mtrs & 1x2T of 12 mtrs
1x2T of 24 Mtrs
1x2T of 12 Mtrs
Jumpering of 33 KV Equipment, jumper from main bus/Line Isolator to 33 KV switchgear with Twin Panther.
Jumpering of 33 KV Equipment, jumper from main to Section Isolator with Twin Tarantula Conductor.
Periphery and switchyard lighting
Providing and fixing of half round GI pipe OD-50mm for mounting the 120 Watt LED light upon gantry mounting of 2 No GI bracket up on gantry and fixing GI pipe complete with nut bolt and washer as per technical specification.
Providing and fixing of junction box on gantry structure with 1 No MS flat 40x5 mm of size 200x200x150 mm made of MS sheet of 16 gauge dully powder coated inside mounting 1 No 6 Amp MCB 1 No TB of 4 terminal & 1 No Kit Kat 16 Amp fixed upon mica sheet and back side mounting a flat 40x5 mm with 1 No 16mm dia hole and mounting PVC pipe from ground level to box as per technical specification.
Supply & fixing of new generation energy saving and environment friendly long life versatile pressure die cost aluminum out door high been flood light 120 Watt LED as light source and exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V input supply for ISI make CGL/Hevells/ Surya/ Philips/Bajaj of equivalent etc. including electrical connection also to be done by the contractor.
Supply Portion: -
Bolted type single Tension fitting for Twin Moose conductor suitable for 1 x10 No Disc insulators with turn buckle and hardware set as per technical specification.
Bolted type single Tension fitting for Twin Moose conductor suitable for 1 x10 No Disc insulators without turn buckle and hardware set as per technical specification.
Bolted type single Tension fitting for Single Moose conductor suitable for 1 x10 No Disc insulators with hardware fitting set as per technical specification.
Bolted type single Tension fitting for Single Panther conductor suitable for 1 x10 No Disc insulators with hardware fitting set as per technical specification.
Bolted type single Suspension fitting for Single Moose conductor suitable for 1 x10 No Disc with hardware set as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Tarantula conductor 1x4 No disc insulator with turn buckle complete with hardware fitting d-shackle, d-socket, Ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Tarantula conductor 1x4 No disc insulator without turn buckle complete with hardware fitting d-shackle, d-socket, Ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
132 KV Isolator clamp suitable for Twin Panther conductor one side connecting the Panther conductor and another side provision for rotating head as per technical specification.
33 KV LA Clamp for ACSR Panther Conductor Complete with HDG nuts & bolts and washer as per technical specification.
33 KV PT Clamp for ACSR Panther Conductor Complete with HDG nuts & bolts and washer as per technical specification.
33 KV Isolator clamp suitable for Twin Panther conductor one side connecting the Panther conductor and another side a plate with 04 Nos. 12mm dia hole as per technical specification.
Bimetalic 33 KV Isolator clamp suitable for single Panther conductor one side connecting the Panther conductor and another side a plate with 04 Nos. 12mm dia hole as per technical specification.
33 KV Section Isolator clamp suitable for Twin Tarantula conductor one side connecting the Tarantula conductor and another side a plate with 04 Nos . 12mm dia. hole as per technical specification.
4 Bolted Type PG clamp suitable for Moose-to-Panther conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG clamp suitable for Moose-to-Moose conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG clamp suitable for Moose-to-Zebra conductor Complete with HDG nut bolt & washer as per technical specification.
03 bolted type PG clamp made of aluminum alloy LM -6 with 01 Nut, bolts and washer suitable for Panther to Panther conductor as per technical specification.
4 bolted type PG clamp made of aluminum alloy LM -6 with GI Nut, bolts and washer suitable for Tarantula to Panther conductor as per technical specification.
4 bolted type PG clamp made of aluminum alloy LM -6 with GI Nut, bolts and washer suitable for Tarantula to Zebra conductor as per technical specification.
4 bolted type PG clamp made of aluminum alloy LM -6 with GI Nut, bolts and washer suitable for Zebra to Zebra conductor as per technical specification.
Spacer for 250 mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for 100 mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for 60 mm spacing suitable for Twin Panther conductor 01 bolted made of aluminum alloy LM-06 complete with hot dip galvanized nut bolt and washer as per technical specification.
Hi-tech power transmission
Technocrat Electrical
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .