Loading…
Loading…
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
25 Mar 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 3 needing a document upload
NA: as advertised cost is less than Rs 50 Lac.
NA: as advertised cost is less than Rs 50 Lac.
NA: as advertised cost is less than Rs 50 Lac.
23 conditions · 13 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Care In Submission of Tender : (In terms of Railway Board letter NO : 2017/CE-I/CT/4/GST dated : 23.06.2017)
(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/Integrated Goods and Services Tax Act, 2017 (IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderer will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under CGST/IGST/UGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UGST/SGST Act to railway immediately after the award of contract without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority
In case the successful tenderer is not liable to be registered under CGST/IGST/UGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority
Supply of telecom equipment along with testing and commissioning and other associated telecom works at Delhi Shahdara & Subzi Mandi stations of Delhi Division of Northern Railway
Project_DLI_SNT_05
Project_DLI_SNT_05
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹97,000
25 Mar 2026
3 Mar 2026
11 Mar 2026
97 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 48,51,524.99 | ||
| — | 2.00 | — | — | ||
| SSupply, installation, testing & commissioning of 240 watts Audio Amplifier working on 230V AC/24VDC as per technical specifications given below:The model should be Philips/Bosch LBD 1916 or similar. (a) Power Source-230V AC & 24Volts battery. (b) Power out put - 240Watts r.m.s. (c ) Input - 4 balanced input/3 stereo line .(d) Frequency response - 50 Hz to 18 KHz(+1/-3db) (e) Distortion - <1%(at rated output power at 1 KHz) (f) Speaker of matching - 8 ohms & 70V/100V line. (g) Sensitivity - 1.0mV(mic input) (h) S/N - 75 db (i) Phantom power - Yes (on mic input 1). Inspection : Consignee | — | — | — | 58,788.04 | |
| — | 2.00 | — | — | ||
| Supply and installation of mettalic rack(front paneI)IockabIe and removabIe)to house the above amplifier com cassette player and 2 sets of 12V/80AH lead acid maintenance free battery and battery charger as per specification. Inspection : Consignee | — | — | — | 26,956.94 | |
| — | 2.00 | — | — | ||
| Supply and installation of 24V/20A battery charger suitable to charge two sets of 12V/80AH lead acid maintenance free battery in series. Inspection : RDSO | — | — | — | 18,258.44 | |
| — | 10.00 | — | — | ||
| Supply and installation of unit horn combination speakers(25Watts) & 100V line with LMT taps of 15W,10W and 5W. Inspection : Consignee | — | — | — | 19,926.3 | |
| — | 10.00 | — | — | ||
| Supply &instaIIation of 20 watt coloumn speakers with 10 watt taping with matching transformer and drive unit as per model no.LBD 8373 of Philips make or SCM-30T of Ahuja make or SHORE make. Inspection: Consignee | — | — | — | 25,268.6 | |
| — | 4.00 | — | — | ||
| Supply and installation of Dynamic microphone with flexible goose neck and ON/OFF swithc provided with 6 metres mic lead along with suitable connectors. Inspection : Consignee | — | — | — | 10,334.92 | |
| — | 4.00 | — | — | ||
| Supply and fixing of slotted angle iron with clamps and nut bolts of appropriate size on the poles/masts in the open parking area and installation of speakers on it. Inspection : Consignee | — | — | — | 1,018.56 | |
| — | 900.00 | — | — | ||
| Supply and laying screened wire twin core(24/76 copper conductors) PVC insulated cable for connecting loudspeakers with GI support wire for connecting loud speakers (PVC channels / PVC conduit pipews/GI wire required for carrying the screened PVC cable shall be supplied and fixed by the contractor, however GI pipe for road crossing shall be supplied by the railway, if required any where. Inspection : Consignee | — | — | — | 86,949 | |
| — | 4.00 | — | — | ||
| "Supply of 4-Wire DTMF base way station eqpt. consisting of the following : i) Supply of 4 wire way station equipment as per IRS - TC -60 / 2007 of latest complete with 4 wire control telephone as per IR S- TC - 38 / 97 with latest amend ment suitable to work on 4/6 quads- ii) Supply of Battery charger/power supply unit 230VAC/12VDC with battery back up of 12V/7AH as per IRS-TC- 72/97 or latest-1 no. Inspection : Consignee " | — | — | — | 34,827.28 | |
| — | 4.00 | — | — | ||
| Installation wiring & commissioning of 4 - wire way station eqpt.Item required for installation such as wires, wiring materials, connectors, battery rack runway, hardware etc. to be supplied by contractor. (job = Per way stn. eqpt.). Inspection : Site Engineer | — | — | — | 15,720.2 | |
| — | 4.00 | — | — | ||
| Supply and Installation of 10 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP boxes & termination of cables as per specifications, drawing and stipulations of tender documents. . This includes fixing of the same on 1" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /waII . All materials required for fixing & termination including salwood/hylum board and the ware required for fixing will be supplied by ontractor. Inspection : Site Engineer | — | — | — | 4,388.64 | |
| — | 4.00 | — | — | ||
| "Supply and Installation of 20 pair DP box made of cast Aluminium with in built locking system and water proof should have double outlet with leadig in brass nozzle.The main tag block plate is mounted on the inner aluminium chamber with brass terminal studded in back lite sheet. DP boxes & termination of cables as per specifications, drawing and stipulations of tender documents. . This includes fixing of the same on 1"" thick board of size as pesr directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /waII . All materials required for fixing & termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. Inspection : Site Engineer" | — | — | — | 6,338.28 | |
| — | 2.00 | — | — | ||
| Installation of Master VHF set 25W on ASM's table and wiring of the same with power supply wiring with 120AH VRLA batt. The 230VAC from IPS to be extended to the Power supply unit of the VHF & provision of power socket. This includes foundation (500x500x1000mm) and erection of the S0mm GI pipe on roof top and fixing of Antenna with GI pipe ( mini. 6 mtr )& wiring from Antenna to the VHF set with provision of guy wires for support of the GI pipe. All the materials cement, sand, GI pipe, guy wires, power wire with socket etc. (VHF set, Antenna & 120AH VRLA batt. to be supplied by the Railway). Inspection : Site Engineer | — | — | — | 14,352.52 | |
| — | 3.00 | — | — | ||
| Supply & installation of Annunciator (Multiway phone Exchange) 10 lines as per RDSO Drg No A-3352 (Adv.) or latest. Inspection : Consignee | — | — | — | 28,149.06 | |
| — | 1.00 | — | — | ||
| "Supply of cable fault locator for underground cable as per model no. Telscout TS- 90(Test signal output 1/2 Sine, Pulse width Snsec to 2500 nsec, Max range: 1500m, Filter cut off frequency :150 Khz (High Pass Filter), Gain : 0 to 63db), Stanlay or similar branded make as per specification . Inspection : RDSO" | — | — | — | 3,10,445.53 | |
| — | 1.00 | — | — | ||
| "Supply of electronic Cable Route Locator / Tracer equipment of C-scope / stanlay make or similar (i) Cable avoidance tool DXL2 digital under ground cable & pipe locating receiver and cable avoidance tool, (ii) SGV2 signal generator, (iii) Signal lamp accessories ST-SC. (iv) Carry bag ST-CB and as per technical specification . Inspection : RDSO" | — | — | — | 2,91,628.33 | |
| — | 200.00 | — | — | ||
| Supply of PVC channel 1"with fixing accessories. Inspection : Consignee Engineer | — | — | — | 3,916 | |
| — | 240.00 | — | — | ||
| "Supply of PVC channel 2""with fixing accessories. Inspection : Consignee" | — | — | — | 17,539.2 | |
| — | 200.00 | — | — | ||
| Supply of PVC conduit pipe 1" dia with fixing accessories. Inspection : Consignee | — | — | — | 6,422 | |
| — | 200.00 | — | — | ||
| Fixing of 1"/2" PVC channel/conduit pipe 1" dia on proper clamps and screws and indoor cable laying. Inspection : Site Engineer | — | — | — | 2,444 | |
| — | 600.00 | — | — | ||
| "Cutting of passenger plateform wall 150mm X 150mm deep to provide 25mm GI dia pipe inside the groove & repairing plateform wall by 50mm thick, CC flooring (1:2: 4} & 100mm thick (1: 4:8) & disposal of rubbish as per direction of site Engineer of railway as a complete job. This item includes all materials required to be supplied by contractor. Inspection : Site Engineer" | — | — | — | 28,092 | |
| — | 12.00 | — | — | ||
| "Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection : Consignee" | — | — | — | 87,642.84 | |
| — | 10.00 | — | — | ||
| "Supply & Installation of Thermoshrink jointing kit for 6-Quad cable and PI3F cable for Derivation/ Termination joints at LC Gates/Pump House/different locations as decided by the site Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 & 2 or latest. This includes all materials required for joints. Inspection : Consignee" | — | — | — | 83,684.4 | |
| — | 10.00 | — | — | ||
| Supply & Installation of U link Panel with 32 Nos of U link. Inspection : Consignee | — | — | — | 24,701.5 | |
| — | 2.00 | — | — | ||
| "Supply ,Wiring and Installation of Managed Expandable rack type STM-1 long haul ADM 51.1 equipped with 21E-1 as per technical spec. no.TEC GR No.GR/SDH -04/02 March 02 with latest amendment 1,2,3 & 4 or latest with 2xSTM agreegate interface 21 Els & 4 Nos of 10/100 base T Ethernet port order wire, power supply unit, sub racks. Installation material & accessories, manual etc. The equipment should be fully wired for its ultimate capacity & provide redundancy for power- supply & synchronization and other details. Inspection : RDSO" | — | — | — | 4,27,349.52 | |
| — | 2.00 | — | — | ||
| "Supply of closed racks complete ( 545mm x 564mm x 2090mm) with all fittings for housing SDH equipments, primary Mux, FDF, DDF, MDF using krone module and other equipments like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender documents. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. Inspection : Site Engineer" | — | — | — | 98,222.9 | |
| — | 2.00 | — | — | ||
| """Supply of 2 MB programmable primary digital drop multiplexer with conference facility and with all common cards like processor card, power supply unit, remote control supervision etc.fitted in sub rack wired for 30 channels along with all other accessories and installation materials and all instruction manuals as per RDSO specn. no IRS TC- 68/04 or latest inspection by RDSO. (i) 2W/4W E&f 1/VF Interface Card (min 4Ckt per card) x 4 Nos (ii) Exchange Loop Interface Card (min 4 Ckts per card) x 1Nos (Total 4 Ckts) (iii) Subscriber/Hotline Interface Card (min 4 Ckts per card} x 1 No(Total 4 Ckts (iv) 64 Kbps G.703 Data Interface card (min 4 Ckts per card) x 1 No (Total 4 Ckts)"" Inspection by RDSO" | — | — | — | 2,53,473.9 | |
| — | 2.00 | — | — | ||
| "Installation , wiring and commissioning of 2 MB programmable drop /insert MUX with conference facility fully wired for 30 channels along with power supply and equipped for various types of interface cards as per site requirements. This includes shifitng and installation of existing MUX. All materials required for the work shall be supplied by contractor. Inspection : Site Engineer" | — | — | — | 27,114.22 | |
| — | 2.00 | — | — | ||
| Supply of 48VDC (2VDC, 200AH x 24) VRLA maintenance free battery as per RDSO spec no.IRS- S-93/96(A) or latest. Inspection : RDSO | — | — | — | 1,30,520.54 | |
| — | 2.00 | — | — | ||
| Supply & installation of SMPS based FCBC charger for system rating 25Amp 48VDC (N+1) configuration i.e. using 2 module of 25Amp with automatic switching between the modules as per RDSO/SPN/TL/23/99 or latest. Inspection : RDSO | — | — | — | 2,13,034.44 | |
| — | 2.00 | — | — | ||
| Supply of power supply unit SMPS 12V DC 15 amp suitable for 25 W VHF specification : Input voltage 100-264V, 50/60 HZ, ouput voltage 12V DC. Ouput type DC, shell material case/aluminium base ouput current 15A max-180W. Inspection : Consignee | — | — | — | 3,201.3 | |
| — | 2.00 | — | — | ||
| Supply of stationery valve regulated lead acid battery 12V/100AH. Spec RDSO IRS:S93/96 with amdt 1. Inspection : Consignee | — | — | — | 16,611 | |
| — | 4000.00 | — | — | ||
| Excavating and refilling of cable trench of 300 mm wide and 1200 mm deep for all type of soil , back filling after laying of teleocm cable/OFC in DWC/HDPE pipes, ramming of soil and consolidation of soil. This inclused clearing of roots trees and bushes & temporary obstruction in selected areas. Where digging of trench of 1200 mm depth or 300 mm width or both is not possible as per site condition & same can be reduced as accepted by site engineer , the payment shall be reduced propotionally acocrding to volume. It shall confirm to safe distnace and cabel route plan. Inspection ; site engineer | — | — | — | 3,23,080 | |
| — | 32000.00 | — | — | ||
| "Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1- 1/97A as per instructions of the site Engineer. Inspection: Site Engineer." | — | — | — | 2,68,480 | |
| — | 100.00 | — | — | ||
| """Supply and installation of RFID electronic marker for S&T underground cable with progammble memory for saving the user specific data inside the RFID electronic marker memory chip,Iater recordable by electronic marker locator during locating(10 cm diameter with floating coil to keep detection circuit always Horizontal for better detection) which can be buded to depth of 5ft in trench. Inspection : RITES " | — | — | — | 1,92,044 | |
| — | 1.00 | — | — | ||
| "Supply of TEC approved electronic cable marker locator for locating quad / signalling cable as per Tec Spec. no G/TIE-07/01 jun 98 along with latest amendment. Inspection by RITES" | — | — | — | 3,07,160.59 | |
| — | 200.00 | — | — | ||
| "All work of horizontal boring and trenchless cabling along with suppIy,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection : RITES for DWC pipe." | — | — | — | 4,08,042 | |
| — | 10000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer. | — | — | — | 89,200 | |
| — | 3.00 | — | — | ||
| "Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site Engineer. It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends . (RDSO specs No. RDSO/SPN/TC/45/2013 revi 2.0) Inspection : Rites for supply portion" | — | — | — | 2,08,491.21 | |
| — | 20.00 | — | — | ||
| End plug for above item. Inspection : Consignee | — | — | — | 629.6 | |
| — | 20.00 | — | — | ||
| Cable sealing plug for above item. Inspection : Consignee | — | — | — | 795.2 | |
| — | 20.00 | — | — | ||
| Plastic Coupler- Slip fit/ Push fit type for above item- Inspection : Consignee | — | — | — | 1,623 | |
| — | 3.00 | — | — | ||
| Blowing/ Drawing of OFC cable in the HDPE duct by mechanical system. . Inspection : Site Engineer | — | — | — | 32,907.81 | |
| — | 5.00 | — | — | ||
| Supply and installation of optical fibre cable joint enclosure as per TEC spec no. GR/O3C-02/01/March 99 with latest amendment and splicing of optical fiber cables (24 fibers and testing) . This includes provision of joint pit (RCC/Prefabricated) as detailed in the technical specifications and as advised by Engineer at site. Inspection : Consignee | — | — | — | 89,414.75 | |
| — | 2.00 | — | — | ||
| Supply and installation of Fibre management system 19" with all installation material, splicing , termination and testing of 2*24 fibre of cable that is 48 fibre with all connectors material as per the instruction of site engineer. Inspection : Consignee | — | — | — | 43,748.98 | |
| — | 1.00 | — | — | ||
| Optical Fiber Splicing Machine conforming to TEC ecs No. G/OSM-01/03, APRIL,2005. Inspection DSO | — | — | — | 4,97,620.45 | |
| — | 10.00 | — | — | ||
| Supply of OFC jumper (patch cards) (10 mtr. long) with FC/PC & SC or suitable connector at both end as per IRS:TC/81-2000 with latest amendments. Inspection : consignee | — | — | — | 6,272 | |
| — | 10.00 | — | — | ||
| "Supply of OFC jumper (pigtails) (10 mtr. long) with FC/PC & SC or suitable connector at both ends as per IRS:TC/81-2000 with latest amendments. Inspection : consignee" | — | — | — | 4,695 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
Tender_docuement_SNT_05_to_publish.pdf Tender document
ATTACHMENT
Tender_docuement_SNT_05_to_publish.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].