Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.5 L+₹85,896.45 (11.2%)Rejected-Finance | L2 | Rejected-Finance BEINF L2 | |
| 3 | L3₹9.0 L+₹1.3 L (17.1%)Rejected-Finance NO 29 CANTONMENT NEAR ANJALI CINEMA HALL SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹9.8 L+₹2.1 L (27.5%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹11.5 L+₹3.8 L (50.3%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHILLONG
GE SHILLONG SHILLONG DIVISION 793002
MISC REPAIR WORKS OF B/R AND E/M INCLUDING PERIODICAL SERVICES TO CERTAIN BLDGS OF DAD COMPLEX AND AAO SHILLONG UNDER GE SHILLONG.
2020_MES_377483_2
GE / SHL / 36 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
SHILLONG
Pl refer tender details
6 documents required · 6 mandatory
₹500
Yes
GE SHILLONG
₹20,000
Yes
30 Jan 2021
20 Oct 2020
5 Nov 2020
21 Oct 2020
4 Nov 2020
23 Oct 2020
60 days
Amount
M&L for Acrylic distemper, one coat over old treated wall or vertical surfaces including necessary preparation of old surfaces complete all as specified and as directed.
M&L for 1mm thick chalk white wall care putty on new or previously untreated surfaces of any description including necessary preparation to make the surface fair and even etc complete all as specified and as directed.
M&L for Acrylic emulsion distemper, two coats over a coat of alkali resistant primer including complete removal of existing treatment of wall and necessary preparation complete all as specified and as directed.
M&L for Acrylic distemper, one coat over old treated ceiling surfaces including necessary preparation of old surfaces complete all as specified and as directed.
M&L for cement base paint , one coat over old treated wall surfaces including necessary preparation of old surfaces complete all as specified and as directed.
M&L for White wash, one coat over old treated ceiling surfaces including cornices , plasters and necessary preparation of old surfaces complete all as specified and as directed.
M&L for White wash, two coats over old treated wall surfaces including complete removal of existing treatment on wall and necessary preparation of surfaces etc complete all as specified and as directed.
M&L for Synthetic enamel paint, one coat, on old treated wooden surfaces over 10 Cm width or girth including necessary preparation of old treated wooden surfaces complete all as specified and as directed.
M&L, Synthetic enamel paint, one coat, on old treated wooden surfaces n.exc 10 Cm width or girth including necessary preparation of old treated wooden surfaces complete all as specified and as directed.
M&L for Synthetic enamel paint, one coat, on old treated steel surfaces over 10 Cm width or girth including necessary preparation of old treated wooden surfaces complete all as specified and as directed.
M&L for Synthetic enamel paint, one coat, on old treated steel surfaces n.exc 10 Cm width or girth including necessary preparation of old treated wooden surfaces complete all as specified and as directed.
M&L for Exterior emulsion paint ( weather coat), two coats over a coat of alkali resistant primer including complete removal of existing treatment of wall and necessary preparation complete all as specified and as directed.
Taking down cement plaster including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site complete all as specified and directed
M&L for Rendering, 15 mm thick plaster in cement sand mortar ( 1:4), in two layers, top 5 mm thick with approved Water proofing compound @ 3% by the weight of cement or as per manufacturers instructions over a layer of 10 mm thick base coat including finishing the surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-Charge. Note WPC shall be measured and paid separately.
M&L for Rendering 10 mm thick in cement sand mortar (1:6) on fair faces of concrete surfaces finished even and smooth without using extra cement etc complete all as specified and as directed.
M&L for Rendering 5 mm thick in cement sand mortar (1:3) on fair faces of concrete surfaces of ceiling finished even and smooth without using extra cement etc complete all as specified and as directed.
Supply only integral water proofing compound, ISI marked.complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer etc complete all as specified and as directed.
M&L for White wash, three coats over new plastered ceiling surfaces including necessary preparation of surfaces complete all as specified and as directed.
M&L for Exterior emulsion paint ( weather coat), two coats over a coat of alkali resistant primer over new plastered surfaces of wall including necessary preparation of new plastered surfaces of wall etc complete all as specified and directed.
M&L for Anti corrosive synthetic enamel roof paint, one coat over old painted surfaces of CGI sheet roof including necessary preparation of surfaces complete all as specified and as directed.
Removing existing roots / trees / plants upto 75mm dia girth and making good to the disturbed surface with cement sand mortar 1:4 etc complete all as specified and as directed.
E&M WORKS Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, lamp holders, regulators, switch, socket outlets, bell push, ceiling rose etc , removing material to store for keeping in safe custody for reuse at site and making good to disturbed surfaces of walls with cement sand mortar (1:6) and white/colour wash to match with existing surfaces etc complete all as directed by Engineer -in -Charge .
M&L Point wiring with single runs PVC insulated FRLSH grade, 1100V grade cable with multistranded copper conductor of size 1.5 Sqmm (Nominal area) (ISI Marked) drawn in and including PVC Casing capping of suitable size with all fittings and accessories including PVC rectangular board of suitable size and drawing continuous earth wire of PVC insulated FRLSH grade, unsheathed stranded copper conductor of size 1.5 Sqmm (ISI Marked) as continuous earth wire terminated in and including sunken box for following type of point wiring including making good disturbed of wall complete all as specified in SSR Part-I, 2009 and Part-II, 2010 and as directed by Engineer-in- Charge for one light point / one fan point etc on independent board controlled by one, one way switch etc complete all as specified and as directed.
All as per item No 24.00 above but for one 2/3 pin socket outlet 5/6 Amps point on independent board etc complete all as directed by Engineer -in -Charge .
All as per item No 24.00 above but for one 2/3 pin socket outlet 5/6 Amps point on same board etc complete all as directed by Engineer -in -Charge .
All as per Item No. 24.00 here-in-before but with FRLSH grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 4.0 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLSH grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 4.0 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per item No 24.00 above but for one call bell point controlled by one 6 amps bell push switch etc complete all as directed by Engineer -in -Charge .
Supply and fix Bell push, piano type, 5/6 Amps, single pole, 230 V (ISI mark) completed all as specified and directed.
Supply and fixing ,Call bell, ding dong, AC, 230 V, Single pole (ISI marked) completed all as specified and directed.
Supply and fix, Switch piano (ISI marked) Single pole 240 volts, flush type, one way 5 Amps complete all as specified and directed.
Supply and fix socket outlet (ISI marked), 2/3 pin and 5 Amps, 240 volts, complete all as specified and directed.
Supply and fix Switch socket combination (ISI marked), 2/3 pin and 5/6 Amps, flush type, 240 volts complete all as specified and as directed.
Supply and fix Switch socket combination (ISI marked), 2/3 pin and 15/16 Amps, flush type, 240 volts complete all as specified and as directed.
Supply and fixing in repair LED batten fittings 1x18 Watt complete pre wired fixed to wall with 2 nos PVC block of suitable size etc complete all as specified and as directed. Make Bajaj Cat Part No BCLSB 18 WH or Crompton cat part no LCTL- CDL-18 or Philips cat part no. DX18 UJJWAL .
S & F in repair wall mounted LED batten fittings with all accessories 1 X 10 Watt LED 6000K , extruded polycarbonate, integrated electronic driver and fixed to wall with 2 Nos PVC block suitable size complete all as specified and as directed .Make Bajaj Cat Part No BCLSB 10 NW or Havells cat part no. LHEXACP7IN1W010 or Crompton cat part no. LCTL-10-CDL.
S&F lamp holder, insulated body, with back plate for batten fitting complete all as specified and as directed.
S&F Ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
Supply and fix in repair MCCB Distribution board, VTP&N , loadline , double door,sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. Make: Havells Cat part No DHDLVDRWGOF004 or equivalent in Schnieder/GE/C&S.
Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW12 or equivalent in Schnieder/GE/C&S.
Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW08 or equivalent in Schnieder/GE/C&S.
Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW04 or equivalent in Schnieder/GE/C&S.
Supply and fix in repair MCCB four pole , 415 Volt, 63 Amps,10 KA , adjustable thermal & fixed magnetic setting complete all as specified and directed.Make: Havells Cat part No - IHLGSF0063 or equivalent in Schnieder/GE/C&S.
Supply and fix MCB SPN, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series, AC , complete all as specified and directed iIncluding taking down old one. Make: Havells Cat part No - DHMGCSNF006-032 or equivalent in Schnieder/GE/C&S.
Supply and fix MCB SPN, 240 Volt, 40 Amps, 10 kA rupturing capacity 'C' series , AC, complete all as specified and directed iIncluding taking down old one. Make: Havells Cat part No - DHMGCSNF040 or equivalent in Schnieder/GE/C&S.
Supply and fix MCB TPN, 240 Volt, 63 Amps, 10 kA rupturing capacity 'C' series , AC, complete all as specified and directed iIncluding taking down old one. Make: Havells Cat part No - DHMGCTNF063 or equivalent in Schnieder/GE/C&S.
Supply and fix MCB SP, 240 Volt, 06-32 Amps, 10 kA rupturing capacity 'C' series AC , complete all as specified and directed iIncluding taking down old one. Make: Havells Cat part No - DHMGCSPF006-032 or equivalent in Schnieder/GE/C&S.
Material and labour for sub main wiring with two single core 6.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 6.0 sqmm green colour as earth lead including PVC casing capping of suitable size complete all as specified and directed, including taking down unservicable one.(Note: two run of 6.0 sqmm cable , one run of earth wire of 6.0 sqmm and one run of PVC casing capping shall be measured as one length).Make- Cable- Finolex/RR kabel/Havells/KEI, PVC Casing Capping- Presto plast/Finolex/Kalinga.
Material and labour for sub main wiring with two single core 4.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 4.0 sqmm green colour as earth lead including PVC casing capping of suitable size complete all as specified and directed, including taking down unservicable one.(Note: two run of 4.0 sqmm cable , one run of earth wire of 4.0 sqmm and one run of PVC casing capping shall be measured as one length).Make- Cable- Finolex/RR kabel/Havells/KEI, PVC Casing Capping- Presto plast/Finolex/Kalinga.
Supply and fix in repairs LED lamp 7Watt B22 etc complete all as as specified and as directed. Make Havell's Cat part No LHLDEUEEML8X007 or equivalent make of Bajaj / Philips / Wipro
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including taking down old unserviceable one etc complete all as specified and as directed.
M/S Mani Construction
M/S Surendra Prasad and Associates
Kshir Furnishers and Builders
M/S U.K ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .