Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAdmitted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹6.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.4 Cr+₹98.3 L (15.2%)Admitted-Finance MECHATRONICS HOUSE MUMBAI BANGALORE BYPASS HIGHWAY WARJE PUNE MAHARASHTRA 411058 | PUNE | MAHARASHTRA | 411058 | ₹7.4 Cr+₹98.3 L (15.2%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Rejected-Technical Non reponsive |
| 4 | Rejected-Technical 1 6 GOKHLE MARG 1ST FLOOR NEAR RED HILL SCHOOL LUCKNOW LUCKNOW | - | - | Rejected-Technical Non reponsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non reponsive |
| Sl No | Description | Qty | Unit | YOKOGAWA INDIA LIMITED L1 | Mechatronics Systems Pvt Ltd L2 |
|---|---|---|---|---|---|
| 1.00Part A-Supply Discharge Measurement System | |||||
| 1.10 | Supply of Automated Water Level transmitter non-contact Ultrasonic type having 10 m range for measuring upstream level and downstream discharge of canal including all necessary cabling with suitable conduits and electrical fitting and mast complete as per technical specification.(including all taxes) | 71 | Nos. | - | - |
| 2.00 | Supply of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of canal gates,including cabling and integration with PLC/ RTU/ Data logger complete as per technical specification (including all taxes) | 97 | Nos. | - | - |
| 3.00 | Supply of Side looking ADVM(Acoustic doppler Velocity meter) for downstream discharge measurement in head /cross regulators including integration with PLC/RTU/datalogger complete as per technical specifications.) | 9 | Nos. | - | - |
| 4.00 | Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs and GPRS/ GSM modem. Suitable 24V DC power supply to power up PLC/RTU panel, including suitable switch mode power supply (SMPS) with 1 KVA UPS for power back up of minium 2 hours, 8 " HMI display and Industrial type electrical fitting and cabling with suitable conduits complete for all related field instruments, as per technical specification. (including all taxes) | 24 | Nos. | - | - |
| 5.00 | Supply of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cable for providing uninterrupted power supply to PLC/ RTU system installed as per technical specifications. | 24 | Nos. | - | - |
| 6.00 | Level Measurement System in distributaries of Gang Canal for Locations having discharge (1 to 5Cumec) Supply of non contract Battery operated Ultrasonic/RADAR type water level transmitter with GPRS/GSM (internal/external type) comunnication system for canals having 06 metter range with all necessary hardware as per technical specification. | 4 | Nos. | - | - |
| 7.00 | Supply of Aacoustic Doppler Current Profiler(ADCP) with associated peripherals, laptop along with software and with all accessories for discharge measurement of canals Bhakra and Gangcanal system required attachement at site, complete as per technical specification including all taxes | 1 | Nos. | - | - |
| 8.00 | SCADA Control Room Equipment’s for Bhakra & Gang Canal System
Supply, engineering and development of customized SCADA software for complete bhakra and gang canal system automation with life time licensed version as per technical specifications. (including of all taxes) | 2 | Nos. | - | - |
| 9.00 | Supply of master controller server which includes server with server rack and Industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete for Bhakra & Gang Canal System, as per technical specifications.(including of all taxes) | 4 | Nos. | - | - |
Tender Value
₹7.5 Cr
EMD Value
₹15.0 L
Closing Date
29 Jun 2020, 11:00 amClosed
Chief Engineer
OFFICE OF THE CHIEF ENGINEER, WATER RESOURCES (NORTH) HANUMANGARH
Supply, Installation, Testing, Commissioning, Operation and Maintenance of SCADA Based Canal Monitoring for Bhakra and Gang Canal System of Water Resources Department Rajasthan under National Hydrology Project (NHP)
2020_WRDAS_183231_1
NIB_01_2020-21
Open Tender
Civil Works
Item Rate
365 days
Hanumangarh
As per bid documents
3 documents required · 3 mandatory
₹5,000
Executive Engineer Bhakra Sidhmukh Regulation Div.
₹15.0 L
Hanumangarh
4 Aug 2020
9 May 2020
29 Jun 2020
9 May 2020
29 Jun 2020
9 May 2020
9 May 2020 - 26 May 2020
22 May 2020
Amount
Part A-Supply Discharge Measurement System
Supply of Automated Water Level transmitter non-contact Ultrasonic type having 10 m range for measuring upstream level and downstream discharge of canal including all necessary cabling with suitable conduits and electrical fitting and mast complete as per technical specification.(including all taxes)
Supply of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of canal gates,including cabling and integration with PLC/ RTU/ Data logger complete as per technical specification (including all taxes)
Supply of Side looking ADVM(Acoustic doppler Velocity meter) for downstream discharge measurement in head /cross regulators including integration with PLC/RTU/datalogger complete as per technical specifications.)
Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs and GPRS/ GSM modem. Suitable 24V DC power supply to power up PLC/RTU panel, including suitable switch mode power supply (SMPS) with 1 KVA UPS for power back up of minium 2 hours, 8 " HMI display and Industrial type electrical fitting and cabling with suitable conduits complete for all related field instruments, as per technical specification. (including all taxes)
Supply of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cable for providing uninterrupted power supply to PLC/ RTU system installed as per technical specifications.
Level Measurement System in distributaries of Gang Canal for Locations having discharge (1 to 5Cumec) Supply of non contract Battery operated Ultrasonic/RADAR type water level transmitter with GPRS/GSM (internal/external type) comunnication system for canals having 06 metter range with all necessary hardware as per technical specification.
Supply of Aacoustic Doppler Current Profiler(ADCP) with associated peripherals, laptop along with software and with all accessories for discharge measurement of canals Bhakra and Gangcanal system required attachement at site, complete as per technical specification including all taxes
SCADA Control Room Equipment’s for Bhakra & Gang Canal System Supply, engineering and development of customized SCADA software for complete bhakra and gang canal system automation with life time licensed version as per technical specifications. (including of all taxes)
Supply of master controller server which includes server with server rack and Industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete for Bhakra & Gang Canal System, as per technical specifications.(including of all taxes)
Supply of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 color printer as per technical specifications.
Supply of LCD Screen (Technnology LED backlit,Screen type, touch screen size 203 cm Resolution 1920x1080 full HD Aspact ratio 16:9, Brightness minimum-350 nits contrast ratio 5000:1 pixels, Duty cycle 16x7 on site OEM warranty 3 Years)
Online 3 KVA UPS with Battery system for power back up of bhakra and gang canal control room equipment’s as per the technical specifications. (including of all taxes)
Supply of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing and all associtated accessories at bhakra and gang canal control room as per technical specifications. (including of all taxes)
Supply of Laptop & 4G/3G internet dongles along with licenced version of SCADA software for remote viewing for monitor as per technical specifications.
Supply of chairs type 2 ( castors without,type of seat and backrest - seat made of polyurethane foam and backrest made of mesh, chair type with arms, type -cantilever inclusive all taxes
Supply of workstation (overall height of work station partition-1200 mm, size of drawer unit (widthxdepthxheight) - 390x440x147 (mm), Depth of table top - 750 mm, Length of table top- 1200 mm ) inclusive all taxes
Supply of Almirah (Thickness of sides in mm - 30mm, Height in mm - 1350, Depth in mm - 450, width in mm - 760 ) inclusive all taxes
Table Type 1 (Length of table top-1800 mm, Depth-900 mm, Height-750mm, Storage unit both sides) (inclusive all taxes)
Table Type 2 (No. of storage unit-double storage, storage provided both side, Length of table top-2100 mm, Height- of table top-750mm, Depth of table-1100 mm, Table top material and thickness-25mm) (inclusive all taxes)
Table Type 3 (Storage provided one side, Depth of table-600 mm, Length of table top-1200mm) (inclusive all taxes)
Table Type 5 (Seating Capacity-8 seater, Width in mm-1200, Length in mm-2400, Shape of table top-Rectangular, Height in mm-750 mm) (inclusive all taxes)
Chair Type 1 (Mesh Back Type-push back, Arm with, Chair Type-central tilt synchronic) (inclusive all taxes)
Chair Type 3 (Frame Type-Cantilever, Type of seat and Backrest-padded with polyurethane Foam, Castors-without) (inclusive all taxes)
Chair Type 4 (Chair Type-with Arms, Frame Type-4 Legs, Castors-without) (inclusive all taxes)
Chair Type 5 (Overall Depth in mm-640, Overall Length in mm- 1655, overall Height in mm-835) (Inclusive all Taxes)
Chair Type 7 (Revolving chair medium back, support backrest symmetrical lumber support, Back cover mesh fabric) (Inclusive all Taxes)
Sofa Set (Frame covering- Fully Upholstered, Total number of seats in the sofa set(Nos)-4, Covering material for seat and backrest-Leatherite) (Inclusive all Taxes)
Centre Table (Size - 3x1.5 ft Wooden centre Table) (Inclusive all Taxes)
Part B. Related Services
Discharge Measurement System in Bhakra & Gang Canal Installation, Testing and commissioning of Automated Water Level transmitter non-contact Ultrasonic type having 10 m range for measuring upstream level and downstream discharge of bhakra and gang canal system including all necessary , cabling, with suitable conduits, industrial type electrical fitting and mast complete as per technical specification. (including of all taxes)
Installation, Testing and commissioning of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of canal gates, including cabling and integration with PLC/RTU as per technical specifications.
Installation, Testing and commissioning of Side looking ADVM( acoustic doppler velocity meter) for downstream discharge measurement in head /cross regulators including integration with PLC/RTU complete as per technical specifications.
Installation, Testing and commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs and GPRS/ GSM modem. Suitable 24 V DC power supply to power up PLC/RTU panel, including suitable switch mode power supply(SMPS) with 1KVA UPS for power backup of minimum 2 hours, 8" HMI display and Industrial type electrical fitting and cabling with suitable conduits complete for all related field instruments, as per technical specification. (including of all taxes)
Installation, Testing and commissioning of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cable for providing uninterrupted power supply to PCL/ RTU system installed at bhakra and gang canal system as per technical specifications.
Level Measurement System in distributaries of Gang Canal for Locations having discharge (1 to 5 Cumec) Installation, testing & Commissioning of Non Contact of Battery operated Ultrasonic/RADAR type water level transmitter with GPRS (Internal/external type) communication system for canals having 6m rangewith all necesary hardware (mast/cantilever) and associated civil works for mounting the instrument as per technical specification.
Installation, testing & Commissioning of Acoutic Doppler Current Profiler (ADCP) with associated perispherals, Laptop alongwith Software and with all accessories for discharge measurement of Bhakra & Gangcanal System required attachment at site complete as per technical specificaiton with two year warranty period.
SCADA Control Room Equipment’s for Bhakra & Gang Canal System Installation, Testing and commissioning of Customized SCADA software for complete automation with life time licenced version as per technical specifications. (Including all taxes)
Installation, Testing and commissioning of Master Controller server with SCADA software which includes Server with server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications including of all taxes.
Installation, Testing and commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 colour printer as per technical specifications.
Charges for High-speed synchronous internet connection (min. 8Mbps upload and download speed) and Static IP for five years.
Installation, Testing and commissioning of Online 3 KVA UPS with Battery system for power back up of Bhakra and Gang Canal system control room equipment’s as per the technical specifications.
Installation, Testing and commissioning of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing, starter pannel, energy meter and cabling complete in all respects as per technical specification including of all taxes.
Charges for 4G/3G internet dongles for five years which is to be provided along with laptop having lifetime licenced version of client SCADA software for remote viewing & monitoring of Canal automation as per technical specifications.
Operation & Maintenance Four Years Operation & Maintenance and Comprehensive Warranty for Canal automation system along with accessories, installed at designated locations within Gang & Bhakra canal system Rajasthan after final acceptance of Canal automation system. This includes replacement of material and consumable (batteries) as and when required at bidders’ cost. The cost of communication for GSM & GPRS (SIM and internet charges) for data transmission shall be borne by bidder. Minimum one service engineer shall be placed at each SCADA Control Room for Operation of Canal SCADA system for entire warranty of period four years.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU and SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment& SCADA configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies Nos. of days and participants are mentioned in Sec-VII clause 4.6 of bid document.
Part C. Civil works - Scada office cum control room and conference hall
Earth work in excavation by mechanical means (hydraulic excavator ) manual means in foundaton trenches or drains (not exceeding 1.5 m in width or 10 sum on plan ) including dressing of sides and ramming of bottoms ,lift upto 1.5m including taking out the watering & ramming and disposal of surplus excavted soil as directed with in a lead of 50meter.
Provinding and laying in position cement concrete including curing , compaction etc. complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level M-10 grade nominal mix 1:3:6(1cement :3coarse sand :6 graded stone aggregate 20mm nominal size .
Brick work with common burrent clay F.P.S. (Non modular) bricks of class designation 75 in foundation and plinth level in : Cement mortar 1:6 ( 1 Cement : 6 coarse).
Brick work with common burrent clay F.P.S. (Non modular) bricks of class designation 75 in superstrtucture above plinth level upto floor level in all shapes and size in : Cement mortar 1:4( 1 Cement : 4 coarse) .
Provinding and laying damp -proof course with cement concrete grade M-15(1:2:4) prepared with 1% solution of water-proof compound complete as per specification . 50mm thick .
Centring and shuttering with plywood or steel sheets including strutting propping bracing both ways and removal of formwork for foundation ,footings,strap beam , raft ,bases of columns .
Providing and fabricating reinforcement for R.C.C. Work including straighteninng , cutting,bending,placing in position and binding (including cost of binding wire) all complete up to floor five level, Theremo mechanically treated bars (conforming of relevent IS code)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix .
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :12mm thick .
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with water proofing cement paint of required shade including all scaffolding. : New work (Two or more coats applied @ 3.84 kg/10 sqm).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.
P & F 1st quality Vitrified tiles on floor, skirting and steps etc. in different sizes ( thickness to be specified by manufactuer ) with water absorption less than 0.08 % and confirming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grouting the joints with white cement and matching pigment etc complete. size 600 mm x 600 mm.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. size 600 mm X 600 mm.
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Black/South 1501 Cm2 to 3600 Cm2 Tiles .
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : profile A&B B-9.6.1
Providing and fixing external grade board solid core single/ Double leaf flush door shutters IS: 2202(Part-II)1996 marked using Phenol formal dehyderesin in glue both sides with approved stainless steel fittings complete as per annexure 'A' commercial venner both side .
Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable.
Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
Providing and fixing 14 mm thick Acoustical with fine fissured tiles/ Mineral fibre high density tiles with butt edges false ceiling tiles of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. (The tiles should of 90 % RH avg. NCR 0.55 light reflectance> 80% thermal conductiveity K = 0.052-0.057 w/m K colour white. Fire performance class 0/class I(BS 476) with warranty against sag) .
Providing and fixing of wall paneling on grid made out of PVC profile section of size 21x17mm with a wall thickness of 1.5mm+/-0.2mm,fixed on the existing wall with wood screw of size 50mm X 8mm with rowel plug at a spacing of 900mm center.uPVC profile section of size 150mm X 10mm with a wall thickness of 1.0mm+/-0.2mm to be fixed on the grid by self tapping screw of size 19mm X 6mm. Necessary cutouts for electrical connection to be provided at required places. The edge and periphery, finally to be covered by extruded PVC beading section of size 28mm X 12mm with a wall thickness of 1.0mm+/-0.2mm complete as per manufacture’s specification and direction of Engineer-in-charge.
P&F rigid PVC Pipe (IS:4985 mark) class II (4 Kg /Cm2) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110 mm dia .
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 15mm nominal outer dia pipes .
25mm nominal outer dia pipes.
P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor .
P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, syphon with copper tube, C.I. brackets complete including cutting and making good the wall. PVC Automatic flushing cistern - 10 Litre Capacity.
P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. WVC Flat Back size 430x260x350 mm./ Wall corner 340x410x265 type liped front.
P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, PVC waste pipe with PVC nut 32mm complete including cutting & making good the wall :Size 450 mm x 300 mm.
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:Brass 400 grm,15mm nominal bore.
P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including placing on terrace (at all floors), making connection etc. complete of approved design.1000 Litre capacity.
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked).
construction of septic tank in all types of soil with 345 mm thick brick mesonary in CM 1:6,15CM thick C.C. bed of 1:5:10 ,M-15 Grade CC flooring & over stone slab covering , 80 mm thick slab ,joiting of slab in CM 1:3 ralthal ,kharanja , 50mm thick stone partition walls, 20mm thick plaster in CM1:6 finished with neat floating cement ,4 nos CI foot rests of approved design , two no 450 mm dia each cement concrete cover with frame , earth work etc. complete as per appoved drawing including disposal of surplus earth within a lead of 50 mtr : size 200*100*130cm(for 10users).
Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 60 Cm & 10 to 12 Mtr deep.
P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type.
Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Size 600 x 450mm x 4 mm thick .
P & F Soap Dish or Tray of approved quality/make C.P. brass .
Making of hole in wall of required size for housing exhaust fan and same with cement plaster as required of following size more than 457mm &upto 610.
P & F of ventilating fans, capacitor start, single phase with impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
P & F of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. Power Consumption of ≤ 7W/ 10W / 15W / 18W with ~ 500 / 750 / 1100 / 1250 lumens, System Lumen efficacy of 70 lm / watt output suitable to replace 1x18W / 2x18W / 2x 26W CFL Downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance.Recessed Mounting LED Downlight 9/10W .
P&F of decorative round/square shape surface mounting ceiling fitting complete with horder ,aluminium anodized back plate glass globe of appoved desing,prewired terminal block making connection ,testing etc .as required as approved by engineer in charge E192001 150mm
P& f Star rated double ball bearing capacitor start , aluminium body &blade ceiling fan with down rod up to 30 cm with 3*1.5 sqm pvc insulated flexible copper conductor making connectin testing etc as required 1200mm sweeo 5 star rated .
P&F of IP 20 led tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-8/T-12 tube light integral driver 2000 luman with 5% tolerance system luman efficiency of 100 Lm / watt minimum expected life time of 25000 burning houres , CCT 5700 K, ANSI ,CRI 80 , driver efficincy > 85% , life expectancy of driver min 30000 hrs PF 0.95 at full load / 230volt AC.
Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, round tles, moulded PVC Modular box with earth terminal, 6 A two way Modular switch, Modular plate with grid plate, screws, making connections, testing etc. as required. short point(up to 3 m)
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Single pole MCB 6 A to 32 A rating
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Single pole MCB 6 A to 32 A rating
SITC of Air Cooled split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 4 Mtr (IDU to ODU), R-22/R-410 Refrigerant, Remote, suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / reciprocating / rotary compressor as specified.1.5 TR with 5 star rating of BEE .
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) PVC casing capping & it's accessories, round tiles, Moulded PVC Modular Box with , 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required.E010500 short point(up to 3 m)
Medium point( up to 6 m)
long point( up to 10 m)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 8 mm thickness .
SITC of self contained drinking water cooler with energy efficient hermetic sealed type compressor ,non CFC refrigerant suitable for operation 0n 230V/1pH/50Hz as supply, fullnstainless steel{S304}Body and tank ,stainless steel water tray , minimum two nos faucets and suitable drainage system complete in all respect with 300mm height ms fabricated and painted plateform .complete in all respect of the following capacity. cooling capacity 80ltr/Hr and storage capacity120ltr
SITC of reverse osmosis water purification system (RO system) compatible for water cooler with ABS construction fully automatic operation with auto start and auto off capacity ,equipped with standard filtration stage/ cartridge (sediment filter, activated carbon filter .UF ,sediment,filing composite RO mebrane),input power supply 100-250V AC 1 PH. system voltage 24vDC, percentage reduction in TDS 90% or better .the job includes installation at site with existing water supply line with requterly service(and also as & when required) of above RO system during warranty period including requied consumable items. Production capacity -15LPH , WATER Storage capacity 8ltr .
supply installation testing and commisioning of1.8 KVA pure sinewave home UPS/ INVERTER WITH 2 numbers 150AH tubuler battery for backup. With following specification:- specification rating 1.8KVA technology- DSP Pure sinewave technology -DSP pure sinewaval/ PV - 120-280VAC(inverter mode).180V-250VAC(UPS mode) O/P voltage -220VACVoltage regulation :-+/-5%(on batt. mode) technology -DSP Pure sinewavel/P V- 120-280VAC(inverter mode ),180V-250VAC(UPS MODE)O/P voltage regulation :-+/-5%(on batt. mode)O/P frequency :-50Hz+/-Hz(battry mode) over load capacity:-110% for 5min. on mains mode efficiency:- better than 92% charging current :-7A/10A/12A/15A/20A/25A (programmble) D.C. voltage :-24AH capacity:-3600VAH indicatioms:- mains on,inverter on,O/L, low battery,battery charging protections :-rev phase,S Ckt, over temp. O/L, battery loose relative humidity :-95%RH Non-condensing operating temprature :-0-50 deg.c safety standard:-IEC/EN60950EMC Std:-IEC-EN62040-1, EN62040-2,EN62040-3,EN61000-4,EN60146 Certificates:-ISO 9001,ISO 14001,ISO18001,ROHS &CE .
Providing and fixing 1.0mm thick Stainless Steel AISI 304 (18/8) kitchen sink & IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Stainlees steel kitchen sink - with drain board 510 x 1040mm bowl depth 200 mm.
P & F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required.400 mm sweep(Oscillating type)
P & F of IP20 LED ceiling / recessed / suspended mounting light fixture made from CRCA sheet steel housing, high purity / transmisivity diffuser for uniform light distribution. High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards (Integral with light fixture). Power Consumption of 40W / 50W / 60W ~ 3000/3300/4200 lumens, System lumen efficacy of 70 - 80 lm/Watt output suitable for 2x36WFTL / 2x36W CFL / 3x36W CFL light fixtures, life time of 50,000 burning hours with 70% initial lumens maintained. CCT 3000°K, 4000°K & 6000°K. Fixtures shall be CE compliance.36W LED light fixture 2'x2' with acrylic / prismatic front cover.
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.On board .
UPVC SOIL WASTE & RAIN WATER (SWR ) PIPESProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes.Type A 110 mm diameter.
P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Bend 87.50 110mm dia.
Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required.
Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 75mm x 72mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work.
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.2 x 2.5 sq.mm
Part D. Civil works - Construction of 12 no. Gauge huts with toilet unit at various head/X-Regulator
Earth work in excavation by machanical means( Hydraulic excavator) /manual means in foundation trenches or drains ( not exceeding 1.5mtr in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 Mtr. Including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr. all kinds of soil.
P & L in cement concrete including curing compaction etc. complete in retaining wall, return walls,walls (any thickness)including attached plasters, columns piers, abutments pillars posts struts,butterness, string or lacing courses, parapets coping bed blocks anchor blocks plain window sills, fillets, leveling course etc. upto floor five level excluding the cost of centering and shuttering , M10 grade 1:3:6 ( 1 cement : 3 coarse sand : 6 Graded stone aggregate 20 mm nominal size).
Brick masonary with common burnt clay FPS (Non Modular) bricks of class designation 7.5 in ,:foundation and plinth with Cement mortar 1:6 ( 1 Cement : 6 Coarse sand).
Brick work with common burnt clay FP.S (Non modular) bricks of class designation 7.5 in superstructure above pliinth level upto floor five level in all shapes and size in . Cement mortar ( 1 Cement : 6 Coarse sand).
Centering and Shuttering with plywood or steel sheets including strutting , propping , bracing both ways with steel props and removal of formwork for up to floor five level for suspended floors, roofs,landings staircases, balconies, girders, cantilevers, bandks coping be plates achor blocks, sills chharjjas, lintel, beam plinth beam etc.
Providing and fabricating reinforcement for R.C.C. Work including straighteninng , cutting,bending,placing in position and binding (including cost of binding wire) all complete up to floor five level, Theremo mechanically treated bars (conforming of relevent IS code)
P & L in position specified grade of cement concrete for RCC structure elements upto floor five level including curing compaction finishing with rendenring in cement sand mortar 1:3 ( 1-Cement : 3-Coarse sand ) and making good the joints and cost of plastizers (if required) excluding the cost of , shuttering and reinforcement for beam, suspended floors roofs, griders having slopes upto 15 digree landings , balconies, shelves chajjas lintels banks, plain windows sills staircases and spiral staircases etc. M 20 grade Nominal mix/ deisng mix.
Plaster on new surface on walls in cement sand mortar 1 : 4 including raking of joints etc. complete fine finish: 12 mm thick.
P & F ms sheet single leaf door shutters in angle iron frame 35×35×5 mm suitably diagonally braced with 25×3 mm flat ironabove and below lock rail of size 50×5 mm beading extra including all fittings , as per direction of engg. In charge but excluding cost of chokhats including two coats of anti corrosive red oxide primer paint. MS sheet 20 SWG. Add extra for double leaf shutters.
Painting with synthetic enamel paint of approved brand and manufacture to give an envebn shade Two or more coats on new work .
Costruction of soakage well in all type of soil with 345 mm thick dry masonary, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab,jointing of slab in CM 1:3,Rathal,Kharanja,40mm thick M-15 grade c.c flooring,earth work complete as per approved drawing including disposal of earth with in a lead of 50 Mtr. Size 240 cm dai outside & 240 cm depth
P&F Squatting Pan (Indian type) white glazed vitreous china first quality W.C Pan (IS : 2556 Mark ) with 100 mm vitreous china P or S trape incuding cutting and making good the wall and floor (excludind the pair of foot rest) Size 580 mm .
P& F Low level Flushing Cistern of 10 litres capacity (IS :2556 Mark). Of approved make with complete fittings C.I brackets duly painted , brass wall cock with ball, (IS :1703 Mark ) complete including cutting and making good the wall with PVC with bend as per IS:7231.
providing and fixing Chlorinated polyvinyl Chloride (CPVC) pipes , having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings, this including jointing of pipes and fittings with one step CPVC solvent cement , trenching refilling and testing of joints complete as per direction of Engineer incharge (External work) 40 mm nomimal outer dia pies .
P&F PVC storage tank (IS:12701Marked indicating the BIS license No.) approved make with cover ,25 mm dia 1 m long G.I overflow pipe and 25 cm .long wash out pipe with plug and socket ,including placing on terrace (at all floors), making connection etc.complete of approved design 300 litre capacity
P & L water proofing treatment to vertical and horzontal surfaces of depressed portions of W.C. kitchen and the like consisting of :i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conformin to IS 2645 in recommended proportions includingh rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3(1 cement 3 coarse sand ) mixed with water proofing compoound in recommended proportion including rounding off juntion of vertical and horizonal surface. iii) IIIrd course of applying blown or residual bitumen aspplied hot at 1.7 kg per sqm of area.iv) IVTH course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100 mm wide and paster to each other with bitumen @ 1.7kg/sqm)
Precast terrazzo tiles of approved make, 22mm thick with marble chips of size upto 12 mm laid in floors, and landing, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete on 20 mm thick bed of cement sand mortar 1:4. Dark shade using ordinary cement.
P&F steel glazed doors, windows and ventilators shutters of standard rolled steel section joint mitred and welded with steel 13×3 mm lugs 10 cm. long embedded in cement concrete blocks 15×10×10 cm of 1:3:6 ( 1- Cement : 3- coarse sand : 6 - graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and fittings except neccessary hinges of pivots steel handles and peg stay etc. as required. Windows side hung. /Ventilators top or centre hung (openable)
P & F Squre bars or other flat welded to window , ventilators etc.
Part E. Civil works - Construction of 7 Gauge Well at various head/X-Regulator
Earth work in excavation by machanical means( Hydraulic excavator) /manual means in foundation trenches or drains ( not exceeding 1.5mtr in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 Mtr. Including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr. all kinds of soil.
P & L in cement concrete including curing compaction etc. complete in retaining wall, return walls,walls (any thickness)including attached plasters, columns piers, abutments pillars posts struts,butterness, string or lacing courses, parapets coping bed blocks anchor blocks plain window sills, fillets, leveling course etc. upto floor five level excluding the cost of centering and shuttering , M10 grade 1:3:6 ( 1 cement : 3 coarse sand : 6 Graded stone aggregate 20 mm nominal size).
Brick masonary with common burnt clay FPS (Non Modular) bricks of class designation 7.5 in ,:foundation and plinth with Cement mortar 1:6 ( 1 Cement : 6 Coarse sand).
Plaster on new surface on walls in cement sand mortar 1 : 4 including raking of joints etc. complete fine finish: 12 mm thick.
providing and fixing Chlorinated polyvinyl Chloride (CPVC) pipes , having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings, this including jointing of pipes and fittings with one step CPVC solvent cement , trenching refilling and testing of joints complete as per direction of Engineer incharge (External work) 40 mm nomimal outer dia pies .
Providing and fabricating reinforcement for R.C.C. Work including straighteninng , cutting, bending, placing in position and binding(including cost of binding wire) all complete up to floor five level, Theremo mechanically treated bars (conforming of relevent IS code)
Mechatronics Systems Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
Gang_Bhakra_SCADA.pdf
Tender Documents • 3.80 MB
BOQ_323613.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .