SITC of Water Coolers with Fountains, Bottling Stations and Filtration etc at New Integrated Terminal Building of VSI Airport, Port Blair
2022_AAI_106197_1
AAI/PB/ENGG(E)/NITB/DWF
Open Tender
Electrical Works
Item Rate
120 days
Port Blair
As per NIT
23 documents required · 23 mandatory
₹1,120
₹1.1 L
1 Nov 2022
17 Feb 2022
17 Mar 2022
18 Feb 2022
15 Mar 2022
18 Feb 2022
18 Feb 2022 - 7 Mar 2022
Amount
Supply installation, testing and commissioning of recessed bi level drinking water fountain coolers, with double ss finish bubbler and one bottel filling station Drinking water fountain with 60 LPH cooling capacity, stainless steel body-304, Suitable size Recipients, SS bubbler guard operated between 50 to 120 PSI, chilling unit suitable for R134a refigerant, adjustable thermostat, with Touchless, sensor-activation + mechanical activation at all point with non flamable foam used in the chiller, designed for easy use With MDCU29 antimicrobial, with normal and cold Option , supply complete with all accessories suitable to operate on single phase 230 V + 10%, AC 50HZ, Power Supply. The unit shall comply with GRIHA Certified(Green Rating for Integrated Habitat Assessment), TUV-SUD Certified, ANSI/NSF 61 and NSF/ANSI 372 ,UL Certified. (Model M8CRSBF, Make- Oasis or equivalent in / filtrin/ murdock/ Sunroc).The job is also inclusive of SS- 304 Sheet frame work to cover the balance front space up to the height of fountain for the opening size mentioned in the Technical specification to make look good aestheticaly as per engineer in charge.
Supply installation, testing and commissioning of recessed single level drinking water fountain coolers, with single SS finish bubbler Drinking water fountain with stainless steel body-304, Suitable size Recipients, SS bubbler guard operated between 50 to 120 PSI, with Touchless, sensor-activation + Mechanical activation at all point, designed for easy use With MDCU29, With normal and cold Option , supply complete with all accessories suitable to operate on single phase 230 V + 10%, AC 50HZ, Power Supply. The unit shall comply with GRIHA Certified(Green Rating for Integrated Habitat Assessment), TUV-SUD Certified, ANSI/NSF 61 and NSF/ANSI 372,UL Certified.. (Model M8WR Make- Oasis or equivalent in / filtrin/ murdock /Sunroc ).The job is also inclusive of SS- 304 Sheet frame work to cover the balance front space up to the height of fountain for the opening size mentioned in the Technical specification to make look good aestheticaly as per engineer in charge.
Supply, Installation and commissioning of 50 LPH 4 stage purification system with UV(alfa UV mini light flow rate 50 LPH, UV Lamp and length 475mm, 11 wattage ,along with sediment filter, carbon filter and pre filter, with 300 GPD Pump, with 60 LTR HTP pressure tank of food grade to generate 2-3 Kg inlet water pressure with high pressure switch. All the system will be enclosed open skid hanging arrangement. Make- Oasis/ Eureka forbes/ Kent or Equivalent in approved makes.
SITC of Storage type water cooler with inbuilt UV purfication with cooling / storage capacity of 80/120 LPH with SS 304 grade outer and inner body with 3 stage filtration such as sediment filtration, Carbon filtration & UV filtration of Model SWCNST80120UVE of Blue star Make or equivalent in other approved makes like Oasis/ Voltas/Sidwal as per technical specification as required.
Providing and fixing of 6mm thick annealed SGG Planilaque Evolution ( Premium GRIHA Rated lacquered glass fro Saint -Gabain or equivalent) as approved by engineer in charge fixed with SGG ultrafix or approved equivalent on a preferably leveled 12 mm thck BWP marine plywood on the MS Steel frame work or suitable structure . Lacqured glass must be made industrially ( via curtain coating process), opaque , coated with PU lacquer(50 micron thick) coour consistency, highly durable , humid resitant , environmentally freindly all complete as required to cover / wall panelling for the left out portion of drinking water faclity area ( above the drinking water units) . The wall panel shall be theme based . The theme shall be prepared and submitted for approval from AAI prior to preparation of wall paneling work. The Quote shall be inclusive of all related works for the panelling like , MS fabrication, painting , finishing etc nothing etra shall be paid for any works need to carried out at site for this job.
WACORP HYUNDAI INDIA LTD.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .