Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.2 L+₹30,670 (2.20%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹14.3 L+₹32,017 (2.30%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹15.3 L+₹1.4 L (10.1%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹15.5 L+₹1.6 L (11.2%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jan 2020, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR TO SEWAGE SYSTEM, SEPTIC TANK, WATER TANK AND OTHER BR REPAIR WORKS AT PRATAP ENCLAVE AND NIRMAN VIHAR AT JAIPUR MIL STN UNDER GE JAIPUR
2020_MES_311454_1
GE_J_55_2019_20
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE JAIPUR
Class E cat a(ii)
8 documents required · 8 mandatory
₹500
GE JAIPUR
₹40,000
Yes
5 Feb 2020
3 Jan 2020
29 Jan 2020
3 Jan 2020
27 Jan 2020
16 Jan 2020
3 Jan 2020 - 15 Jan 2020
Amount
Cleaning and disludging of existing septic tank of any capacity / sump well of any dia and depth including taking out sludge in any form and other foreign materials etc viz sediment sand ash, grease, fibre roots or vegetation etc by manually or by mechanically equipment or by way of any other suitable means and removing the sludge out side MOD land by any means all as specified and directed by Engineer-in-Charge Note :- The spetic tank / sump well shall be dewatered first and cubic contents of remaining sludge shall only be measured. however , rate quoted by tenderer shall deem to be included in this rate
Excavation in trenches not exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shaft , wells, cesspits, manholes, pier holes, etc n. exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/ loose soil.
All as per item No 2 above but exc 1.5m but not exc 3m depth
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/ loose soil.
Removing excavated material n.exc 50m & depositing where directed at a level n.exc 1.50m above the starting point in soil.
M&L concrete bed to dain pipes 150mm dia cement concrete 1:3:6, type C-2 including packing under, and haunching against the sides of pipes after they are laid and tested in all as specified
M&L concrete bed to dain pipes 200mm dia cement concrete 1:3:6, type C-2 including packing under, and haunching against the sides of pipes after they are laid and tested in all as specified
M&L reinforced cement concrete pipes 150mm bore of pipe, class NP-2, laid in trenches and jointed complete with collars
M&L reinforced cement concrete pipes 200mm bore of pipe, class NP-2, laid in trenches and jointed complete with collars
M&L salt glazed stoneware drain pipe 150mm internal diameter laid in trenches and jointed as specified
M&L salt glazed stoneware drain pipe 200mm internal diameter laid in trenches and jointed as specified
Cleaning of existing sewage lines ( beyond 1st manhole) dia of pipe line 150mm from manhole to manhole by manual rodding and remove all sludge, waste , debris etc from line.
De sludging and cleaning of existing manholes ( excluding Ist manhole) of any size and shape exc 0.50 mtr but not exc 1.0 mtr depth by removing all sludge, waste, debris etc from man holes and cleaning with water incl disposing off all sludge, waste , debris etc outside MD land all as specified
De sludging and cleaning of existing manholes ( excluding Ist manhole) of any size and shape exc 1.00 mtr but not exc 2.0 mtr depth by removing all sludge, waste, debris etc from man holes and cleaning with water incl disposing off all sludge, waste , debris etc outside MD land all as specified
De sludging and cleaning of existing manholes ( excluding Ist manhole) of any size and shape exc 2.00 mtr but not exc 3.0 mtr depth by removing all sludge, waste, debris etc from man holes and cleaning with water incl disposing off all sludge, waste , debris etc outside MD land all as specified
De sludging and cleaning of existing manholes ( excluding Ist manhole) of any size and shape exc 3.00 mtr but not exc 4.5 mtr depth by removing all sludge, waste, debris etc from man holes and cleaning with water incl disposing off all sludge, waste , debris etc outside MD land all as specified
Cleaning of existing sewage lines ( beyond 1st manhole) dia of pipe line 200 to 300mm and over from manhole to manhole by mechanical rodding by jet pressure rodding sets mounted on sewage cleaning tractor / trucks including removing sludge, waste and debris from manhole which stagnat in manhole due to line cleaning (The contractor himself arrange Jaipur municipal corporation truck i.e equiped with pressure jetting machine with 5000 ltr water tank)
M&L making arrangement for bypass to nearest manhole or line to keep sewage flow continuous providing required necessary T&P such as protable pump set, flexible hose pipe etc all as required at pump set, flexible hose pipe beyond upto 60 meter distance distance. ( Each Job i.e 24 hours )
Demolition of stone or brick masonry built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles
M & L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6
M&L walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in CM 1:4 all as specified
All as per item No 21 above but except in stone
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM 1:4 finished even and smooth without using extra cement.
M&L rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces , finished even other than fair faces all complete all as specified
M & L plain Cement Concrete1:4:8 type D-2 (40mm graded aggregate) in foundation filling and mass concrete
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in coping including necessary form work complete all as specified
M&L PCC 1:2:4 type B-2, using 20mm graded stone aggregate as in surface channels and drains and cenching including finishing the top of benching even and smooth with using extra cement
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc.
M&L precast factory made RCC 1:2:4 type B-1, using 20mm graded stone aggregate for manhole cover including placing over manhole all as specified including demolition of old RCC manhole covers. Manhole cover will be bonded by flat iron border all around all as specified Note :- Reinforcement and flat iron border shall be measured and paid separately.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 30 above but 6mm to 8mm dia
S&F framed bracket of flat iron around manhole cover of any size , cut to shape welded, riveted etc complete all as specified
Cutting into existing manholes/ septic tank for connecting new drains making good to pipe and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1, smooth finished and reforming benching as required for 150mm bore pipe
_dittio_ all as per item No 33 above but 200 mm bore pipe
Cleaning of SOAK WELL 2.4m dia, 4.5m depth ( overall depth) using mechanical pumps diesel driven with fuel, operator and necessary excavation on half buried soil and disposed off soak well water etc in pits including necessary excavation and earth work for pits etc in soft/ loose soil complete all as specified
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for
M&L PCC 1:5:10 type E-2 using 40mm graded stone aggregate in foundations, filling and mass concrete in sunken floor
M&L applying hot bitumen blown type 85/25 grade two coat on concrete/plaster surfaces at the rate of 1.5Kg per Sqm per coat in suken floor
M&L rendering 15mm thick on fair faces of brick work or concrete surface in two layers ( 5mm thick in CM 1:4 over 10mm thick in CM 1:6) finished even and smooth without using extra cement mixed with water proofing compound @ 3 % of cement by weight on top layers. Note :- WPC will measured and paid separately.
Supply only intergal water proofing compound ISI marked
S&F cast iron floor trap of 75mm bore, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified & as directed.
Dismantling of cast iron drain pipe of 100mm bore, jointed in CM and taking out of in trenches. Note :- Excavation & earth work shall be measured and paid separately.
Dismantling of cast iron drain pipe of 75mm bore, jointed in CM and taking out of in trenches. Note :- Excavation & earth work shall be measured and paid separately.
S&F 75mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches complete all as specified and directed.
S&F 100mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches complete all as specified and directed.
S&F 100mm bore cast iron, sand cast soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed on walls complete all as specified and directed.
S & F cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall, 75mm bore sand cast pipe
S&F as in repair 100mm bore cast iron branch piece, single ( equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door
S&F in repair CI cowl 100mm bore fixed to CI pipe complete all as specified and directed.
S&F in repair SGSW gully trap square or round mouthed type 'P' of size 150mm x 150mm with CI grating including raising upto plinth protection with PCC 1:2:4 type B-1, and covered with stone slab complete
S&F as in repair vitreous china squatting pan (Orissa pattern) water closet (white) size 580mm x 440mm with integral foot rests ( excluding flushing cistern and flush pipe ) complete including connection to trap and flushing pipe antisyphonage pipe etc (Demolition of sunken floor treatment is included in this item.)
S & F in repair PVC valveless, syphonic action type flushing cistern 10 liters capacity, low level, white with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density or PVC, 32mm dia suitable for low level cistern,
Demolition and breaking up drain pipes ( Salt glazed ware, AC or reinforced concrete 150mm dia
All as per item No 53 above but 200mm dia
Dismantling old unserviceable RCC / PVC water tank & removal from site complete all as directed capacity exceedind 250 ltr and not exc 500 ltrs
S & F 500 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe pipe etc complete all as specified in SSR Part I, Make - Sintex or eqivalent
S & F as in repair Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm dia (minimum weight 210 gms) complete
S&F in repairs PVC water storage tank cover for capacity exc 250 ltr but not exc 500 ltr including driling holes for nut and bolts all as specified
Taking down cement plaster or cement lime plaster/ tiles of any descrption on PCC/ stone surface/ brick surfaces of wall or ceiling including raking outs joints, hacking for key scrubbing down with water etc
M&L loose filling with broken stone or boulders with aggregate of gauge 80 to 150 mm in soakage pits, soakage well old manholes and similar etc all as specified
M&L for cleaning and removing all scale and dirt etc from tanks capacity exc 250 but not exc 500 ltr and from mouths of circulating pipes etc by using biliching powder and during cleaning damage any fittings ( flaot valve, tank nipple, gate valve ) will be replace without any extra cost all as specified
M&L for cleaning of blockage of 150mm dia of pipe between two manhole by breaking/ pucher of SWG pipe and replaced one to two new pipe including jointed , execavation in any depth , returning filling and removing excess soil all as specified
All as per item No 62 above but 200mm dia of pipe
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint fixed to walls all as specified
All as per item No 64 above but 75mm bore
S&F in repairs PVC (SWR) pipes 110mm fittings such as bend, Tee,socket etc all as specified
S&F in repairs PVC (SWR) pipes 75mm fittings such as bend, Tee,socket etc all as specified
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubbish off the premises
Non skid cermic coloured tiles 6 to 7mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match & including laid over 15mm thick screed bed in CM 1:6
M & L glazed coloured ceramic tiles 300x200x7 mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4 complete.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in cement mortar
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement laid over and including 25mm thick sand cushion layer complete all as directed.
M & L Machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement laid over and including 25mm thick sand cushion layer complete all as directed.
All as per item No 73 above but except tiles
M&L chequered cement concrete tiles 20cm x 20cm x 20mm thick , set , jointed and pointed in neat cement slurry in floors with grey cement and pigment over 20mm thick screed bed in CM 1:6
All as per item No 75 above but except tiles
S&F in repair vitreous china water closet Indian type 580mm long pan white with 'P' or 'S' trap front or back inlet footrest including provn of cement concrete bedding including connections to flushing cistern / pipe and making good disturbed portion to match with existing surface complete all as directed.
Schedule of Credit (Anticipated)
M/S ROHIT CONSTRUCTION
S.R.Enterprises
J.J.ENGINEERING
M/S M.K.Constructions
UNIVERSAL INFRAPROJECT PVT LTD
Sh Manoj Nagar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .