Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC MAHANANDA PARA GOVT SAW MILL ROAD P O SILIGURI DIST JALPAIGURI WB | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.6 L+₹3.6 L (9.77%)Rejected-Finance RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹44.9 L+₹7.9 L (21.4%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹48.3 L+₹11.4 L (30.7%)Rejected-Finance EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹48.6 L+₹11.7 L (31.5%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR/ MAINTENANCE OF LT ELECTRIC SUPPLY DISTRIBUTION INSTALLATIONS WITH ALLIED WKS AT TRHS, 12 PARA (SF), 1840 RKT AREA ETC IN SUKNA MIL STN UNDER GE SUKNA.
2023_MES_599885_1
GE Sukna/8548
Open Tender
Civil Works
Works
270 days
Sukna
As PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
28 Jun 2023
31 May 2023
23 Jun 2023
31 May 2023
21 Jun 2023
15 Jun 2023
1 Jun 2023 - 21 Jun 2023
Amount
S&F in repairs Steel rolling shutters of laths thicknes 1.25 mm, with out ball bearing, as specified incluidng top cover, anchrong rod, hasp and staple and one shop coat of primer; errected in position as indicated, complete; gear operated type with bevel gear box and crank handle etc. all as directed and specified by Engr-in-Charge.
Taking down by unfastening all part of steel rolling shutter of any size viz hood cover, curtain of steel lathe etc and oiling, greasing the pully, shaft incl adjusting the spring, V-clamp, bracket plate and manual operated box along with pipe ends arrangement and refixing the same in same opening for making operative complete all as specified and as directed
M&L preparation of new plastered ceiling surface and inlcuding applying three coats of white wash complete all as specified and directed. Make :- Rajasthan / Apple / Surya
M&L for prepration of new plastered surfaces of wall /ceilingapplying two coat of oil emulsion distemper over a coat of primer over a thin layer of wall care putty to obtained smoothness of plastered surfaces complete all as specified and directed. Make of oil bound distemper :- Apcolite Premium Emulsion (Asian Paints ltd)/ Rangoli (Berger) / No. 1 Premium Acrylic Distemper(Shalimar) Make of primer/ wall care putty:- Asian Paints/ Berger / Shalimar Paints
M&L Preparation of wall surfaces and applying two coats of Cement base paint over one coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge. Make of cement base paint: Durocem Neo(Berger)/ Utsavcem (Asian Paints Ltd)/ Cemkote plus water proof cement paint(Shalimar) Make of primer/ wall care putty:- Asian Paints/ Berger / Shalimar Paints
Preparation of old decorated steel surfaces of any description, not otherwise description over 10cm width or girth and applying one coat of synthetic enamelled paint complete all as specified and directed. Make of synthetic enamel paint:- Apcolite Premium Gloss Enamel (Asian) / Luxol High Gloss Enamel (Berger) / Superlac Premium High Glass Enamel (Shalimar Paints Ltd)
Taking down of LT cable XLPE insulated UG cable of sizes 10 Sqmm to 150 sqmm size complete all as specified and directed. Note:- Excavation, returning filling, removing paid seperately under relevent item complete all as specified and directed.
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Supply,laying testing and commissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm 3.5 core complete all as specified and directed. Make Havells/ Polycab/KEI/ RR Kabels
Re-routing /re-laying of servicible LT UG cable off sizes in trenches with necessary connection and disconnection for re-distribution of load complete in all respects as specified and directed. Note:- Excavation, returning filling, removing, sand, bricks will be measured and paid seperately under relevent items.
Excavation in trenches in any type of soil (soft/loose soil) not exceeding 1.5 metre wide and not exceeding 1.5m in depth LT under ground cables/GI pipes for trenches, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading watering and well ramming in layers not exc 25cm in layers, complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L sand coushioning to UG cables (8cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers NOTE:- punned thickness of 18cm only will be considered for payment purpose complete all as specified and directed.
Supply and fix sub class 'B' bricks of standard size for cable protection in trenches complete all as specified and directed.
Supply and fixing GI tubing light grade 15 mm dia for protection pipe including taking down old unsv ones complete all as specified and directed. Make Jindal steel/ Tata or equivalent.
Supply and fixing GI tubing light grade 40 mm dia for protection pipe including taking down old unsv ones complete all as specified and directed. Make Jindal steel/ Tata or equivalent.
Supply and fixing GI tubing light grade 80 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete incliding taking out if required all as specified and directed. Make Jindal steel/ Tata or equivalent.
Boring/Drilling (horizontally) manually upto 2m depth in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore and getting out and disposal of soil to a dist n.exc 50 meter complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in foundation of poles including necessary form work, finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C2 (using 40 mm graded aggregate) as in foundation of poles including necessary form work, finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B2 (using 20 mm graded aggregate) as in coping/stay of poles including necessary form work, finishing the surface even and smooth without using extra cement complete all as specified and as directed.
S&F street light junction box made from CPRI approved factory having size 200 (Width) x 150 (Depth) x 250 (Height) mm (minimum dimensions) made out of 2.00 mm thick CRCA sheet, duly powder coated of approved shade over a coat of red oxide primer both internally and externally, with rain shed all side except back side, comprising of 02 nos copper bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators, necessary cable entry / exit holes for upto 35 sqmm cables, nut-bolts, MS clamps of suitable size for fixing including dismantling complete all as specified & as directed. Make - Havells/L&T/Hager/Crompton
S&F in repairs 6 KW, three phase, automatic street light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable 24 hour switch, 32A, TP power contactor, 40A SPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd
M&L in repairs PVC Insulated Weather proof multicore FRLS PVC sheathed multistranded cables with bright annealed copper conductor of size 1.5 sqmm 3 core for connection of light to pole box completed all as specified and directed .Make Havells/ Gloster/Finolex/PolyCab
S&F in repair LED street light 70 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V, Make of LED - Cree/Nichia/Osram/Agilent/Lumileds etc and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Note :Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates. Make :- Havells/ Crompton/Philips/HPL/Surya/Orient or equivalent
S&F in repair LED street light 90 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V Make of LED - Cree/Nichia/Osram/Agilent/Lumileds and including fixing arrangement made out of 40 mm bore GI pipe light grade of length not less than 1.2 m, bent to shape, fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Note : 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates.. Make :- Havells/ Crompton/ Philips/HPL/Surya/Orient or equivalent
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 120 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including fixing arrangement fixed with two pairs of 40 x 5 mm MS flat iron clamps, nuts, bolts & washers to fix the fitting with pole complete all as specified and directed. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates. Make :- Havells/ Crompton/Philips/HPL/Surya/Orient or equivalent
M&L for 400W LED flood light complete with aluminum die cast housing with LED, Heat sink, toughtened glass and individual LEDs with secondary lens optics with IP 66 ingress protection, 4 KV built in and 10 KV external surge protection, minimum efficiency 120 lm/w including necessary driver. Make :- Havells/ Crompton/Philips/HPL/Surya/Orient or equivalent
S & F in repair LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP66, IK10, 3.5kV inbuilt surge protection, PF ≥0.95, total System Lumens 1100 lm, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed. Make- Havells, Cat No - RUGBYGENXFTS10WLED865SSYMBOPC or Crompton/ Philips/ HPL/Orient
S & F in repair LED Bldg Security Light ,30 watt made up of pressure die cast aluminiun housing with highly efficient LEDs and PC cover with integrated lens with IP66, IK07, System Lumen Efficasy ≥120 Lm/W, having unique air vent technology which keeps temperature low, 5 kV Surge Voltage Protection,Operating Voltage range 140 V - 270 V and including bracket suitable for street light made out of GI pipe light grade of 25 mm bore & 0.75 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed. Make : Havells Cat No - VILUMINASL30WLED75PASYBOPC or equivalent Crompton/ Philips/ HPL/Surya/Orient
S & F in repair Recess Mounted Round LED Downlighter 15 watt having slim edge with die cast aluminium housing finished in premium white powder coating & PC Opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens Efficiency not less than 110 lm/W and color temp 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed. Make : Havells Cat No - GLOWDLR15WLED830S or equivalent Crompton/ Philips/ HPL/Surya/Orient
S & F in repair Surface Mounted Round LED Downlighter 15 watt having slim edge with die cast aluminium housing finished in premium white powder coating & PC Opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens Efficiency not less than 120 lm/W and color temp 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed. Make : Havells Cat No - GLOWDLS15WLED830S or equivalent Crompton/ Philips/ HPL/Surya/Orient
S&F Recessed Mounted Square (2'x2') LED Panel light 36 watt suitable for mounting with Armstrong/Grid ceiling with CRCA powder coated housing & high transmittance Opal diffuser for glare free with Electronic LED Driver. IP20, PF ≥0.95, System Lumens ≥120 lm/W, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V.complete all as specified and directed. Make- Havells Cat No- PLANO2X2PLR36WLED840S or equivalent Crompton/ Philips/ HPL/Surya/Orient
S&F in repairs 20 watt LED post top lantern, IP-65, die cast aluminium housing, opal diffuser, electronic driver fixing arrangement etc complete all as specified and directed. Make:- Havells / Crompton/ Philips/ HPL/Surya/Orient
S&F 1 x 9/10 watt LED bollard light fitting, IP-65, including 1 metre hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting & taking down complete all as specified and directed. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates. Make:- Havells / Crompton/ Philips/ HPL/Surya/Orient
S&F 50 Watt , 3 meter long LED Tri Colour Light Column with die-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usaseand IP-65 protection with Tricolour and tratic white output switch, driver, all fixing arrangement etc. including electrically connecting & taking down complete all as specified and directed. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates. Make:- Bajaj, Cat- BLSLC 50W LED TRI 3M or eqivalent Havells / Crompton/ Philips/ HPL/Surya/Orient
S&F Solar All in One system 30 W Smart Integrated Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4 ) 12.8V 24Ah Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K Suitable LED efficacy to have system efficacy of not less than 125 Lumen/Watt and Life of LED light fitting Not less than 50000 burning hours including fixing accessories like clamps of suitable size at existing pole and dismentaling out old unsv ones complete all as specified and as directed. Note: 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Contractor will undertaking about warranty certificate of 50000 hr burning life. 3. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates. Make:- Havells / Crompton/ Philips/ Bajaj
S & F in repair 8 Watt Suspended Spot Light , having black powder coated aluminium housingand pressure die castheat sink having high efficiency opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens Efficiency not less than 110 lm/W and color temp 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed. Make : Havells Cat No- UNECOPENDDLP8WLED830S24BLK or equivalent Crompton/ Philips/ HPL/Surya/Orient
S & F in repair Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.95, Efficiency not less than 110 lm/W color temp 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and as directed. Make : Crompton / Philips / Havells/ Bajaj/Surya/Orient
M&L preparation of 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and including applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per existing colour code complete all as specified and directed.
M&L repairs to existing LT panel / bus bar chamber / feeder pillar box of any size by excavation of all loops and removing damaged UG cable, connecting new thimbles / lugs / cable glands and fixing of new neoprene rubber gasket to make it completely dust and vermin proof, fixing of new locking arragement and replacement of LT panel wiring with appropriate size of copper conductor, repairing of rusted parts of panel frame and shutter with necessary welding works including preparation and applying one coat of synthetic enamel paint on both internal and external surface of panel, PCC (1:3:6) type C2 (using 40mm crushed stone aggregate) work in foundation complete all as specified and directed. Note:-The unit rate quoted is deemed to include cost of earth work, PCC in foundation, new thimbles / lugs / cable glands, neoprene rubber gaskets, locking arrangement, Wiring, welding works, painting.
S & F in replacement of RCC pole with Steel Tubular Poles complete with and including cast iron base plate , finial taper plug, bolts , nuts & screws, type 410 SP-31(9 Mtr long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, including taking down of old damaged RCC pole complete all as specified and as directed, Make JINDAL STEEL/NATIONAL TUBING CO/BOMBAY TUBE & STORE/CALCUTTA POLES & TUBE) Note:- Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately.
Blank
Blank
Blank
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, OEM own factory made, supplied by OEM, floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Note: (1) The OEM’s specified cannot authorize to any other partner/sub vendor to manufacturing the panel ontheir behalf. (2) The LT panel will manufactured by OEM own factory only will be accepted & factory acceptance test(FAT) will be carried out at OEM plant only. (3) Panel maker should be CPRI approved with 10tank process & IK10. Make of Panel and Accessories: ABB / Seimens / Schneider / BCH
INCOMING:-
(a) MCCB 4 pole 415 volts 35 KA breaking capacity rating 250 Amps, Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories :- 01 No
BUSBAR:-
(b) Aluminium busbar suitable for 400 Amp including insulator with nuts & bolts - 04 Nos
OUTGOING:-
(c) MCCB 4 pole 415 volts 25 KA breaking capacity rating 100 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No
(d) MCCB 4 pole 415 volts 16 KA breaking capacity rating 63 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 02 No
(e) MCB TPN 40 Amps,10 KA, 'C' curve 240 volts - 01 Nos
(f) MCB SPN 32 Amps, 10 KA, 'C' curve 240 volts - 02 Nos
(g) Lexic indicator lamp with holder = 03 nos
(j) CT of ratio 250/5
(k)Time switches 250 V single Phase of 20 Amp rating with contactor
Supply only electronic driver for LED light of following specifications: -
For 9 to 12 W LED light indoor type. Make as per existing.
For 12 to 15 W LED light indoor type. Make as per existing.
For 34 to 36 W LED light indoor type. Make as per existing.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unsv ones complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing GI strip 32x6 mm with necessary nut and bolt etc for connection with existing Earting pit and electrical equipment including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
S&F 4 mm dia GI wire for earth continuity conductor for making connection from earth test point to main DB including taking down old unsv one all as specified and directed by Engr-in-Charge
ENGINEERING AND CONSTRUCTION CO.
MS ORIENT ENGINEERING WORKS
PS ENTERPRISE
M/s TALCO
Shri U K Ghosh
SHRI N.DAS
M/s T K Das
D K SARKAR
DEBABROTA ROY CHOWDHURY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .