Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC MS Raj Construction is lowest and accepted | |
| 2 | L2₹42.3 L+₹3.5 L (8.88%)Rejected-Finance 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹43.6 L+₹4.8 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹43.8 L+₹5.0 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | Rejected-Technical MAGADH COLONY ROAD NO 6 SHERGHATI ROAD GAYA BIHAR 823001 | GAYA | GAYA | BIHAR | 823001 | - | Rejected-Technical Not Qualified |
Tender Value
₹35.7 L
EMD Value
₹71,500
Closing Date
23 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Y K Gour
HQ CWE Ranchi, MES, Dipatoli Cantt
COMPREHENSIVE MAINT OF HT TRIPPING AND DISTRIBUTION NETWORK AT NAMKUM LPH AREA AND HT DISTRIBUTION SYSTEM INCL REPAIR OF GANG OPERATING DEVICES AT NAMKUM AND KHOJATOLI AREA UNDER GE RANCHI
2023_MES_598360_1
80599/1476/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Ranchi
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Ranchi
₹71,500
Yes
HQ CWE Ranchi
31 Jul 2023
26 May 2023
30 Jun 2023
26 May 2023
23 Jun 2023
9 Jun 2023
26 May 2023 - 2 Jun 2023
2 Jun 2023
Amount
M & L for Servicing / Calibration to 33 KV HT VCB panel ( Incomer panel No : 1) complete including the following : switching off electric supply, Checking of mechanical system for proper functioning, replacing closing buffer, triping buffer (VMX type), V I connection gap check, motor coil resistance check, closing coil resistance check, spring charging cut off switch check, aux switch check, NO-NC states check, trip coil resistance check, testing details, timing test, oil value test, breaker timing test, connector resistance test, IR value test, HV test, mechanical and electrical mechanism check, counter reading check, shock observer check, pre close/ post close circuit check, test and service position limit switch check, breaker drive screw operation check, trip coil assemble operation check, mechanical latch . Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete including replacement of following spares all as directed, Unit rate include two preventive maintenance and one break down during the entire period of work complete all as directed. (a) Control Fuse with link 32 A, - 12 Nos (b) Trip Netural close switch, - 01 No (c) Hooter 30 V DC - 01 No (d) Multifunction energy meter with KHW, KVAH, PF, HZ, KW etc loding - 01 No (e) Indicating LED lamp - 03 Nos Note:- (i) Maitenance of all HT VCB will be carried out as per maintenance schedule (ii) Testing of above job to be carried out by engineers of authorised dealer/service centre. (iii) Test report must be submitted by contractor before placing of RAR / Final bill.
M&L for servicing of oil type transformer 3.15 MVA 33/11 KV out door type of any make by disconnecting of HT bus bar connection,opening of doors etc complete cleaning of the inside compartment ,core and coils by vacuum cleaner including lead supports,tap changer terminal boards,bushing and other insulated surface be wiped clean with dry cloth and all connections must be checked for tightening after cleaning up to the satisfaction of Engr-in- Charge the transformer must be meggred and connecting all connection and necessary testing complete with under mentioned scope of work. (i) Cleaning of transformer. (ii) Testing the transformer for IR values (iii) Checking/servicing/calibration of WTI (iv) Magnetic balance test (v) IR Value check before and after the work (vi) Voltage ratio test at 440 V. (vii) DC logic test (viii) Commissioning of transformer after completion of work. Note :- (i) Test results obtained shall be recorded and produced to the Engr-in- Charge. (ii) All measuring equipments and T&P required shall be arranged by the contractor. (iii) Any item/activity not listed/covered here above and required during/completing the overhauling work will have to be arranged by contractor himself without any extra cost. (iv) The rate quoted by the tenderer shall be deemed to include for disconnection of transformer HV/LV terminations for testing work and re-connections after completion of repair work. (v) Test report must be submitted by contractor before placing RAR / Final bills.
Supply & fix for replacement of Outdoor type current Transformer , CT : Ratio : 100-50/ 5-5A. CORE - 1 :15 VA CLASS : 1. CORE- 2 :36VA CLASS 5P10. STC : 13:1KA 1 Sec. ILV : 12KV/28/75 KVP. SYSTEM VOLTAGE : 33KV. TYPE ; Oil typeAs Per IS -2705 .IEC- 60044 , connecting with electric system such as Control Panel Complete all as directed . Make:- CG/ Kappa/ Laxmi/L&T/ Schneider/ABB/Siemens
Supply & fix for replacement of Potential Transformer , PT : Ratio : 33000/110 Volt 1 phase. CORE - 1 :15 VA CLASS : 1. CORE- 2 :15VA CLASS 5P10. STC : 13:1KA 1 Sec. ILV : 33KV/28/75 KVP. SYSTEM VOLTAGE : 33KV. TYPE ; oil type As Per IS -2705 .IEC- 60044 , suitable for Outdoor VCB including proper Connection to BusBar and connecting with electric system such as Control Panel Complete all as directed. Make:- CG/ Kappa/ Laxmi/L&T/ Schneider/ABB/Siemens
ON LINE dehydration/filtration with machine (not small filtration portable machine) complete all as directed of transformer pole mounted or platform mounted of any capacity complete all as directed.
OFF LINE dehydration/filtration with Ultra High Vaccum machine (not small filtration portable machine) complete all as directed transformer platform mounted of 33/11KV transformer 3.15 MVA capacity after filtration dielectric strength not less than 60 KV at 2.5 complete all as directed.
M & L for Servicing / Calibration to 11 KV HT VCB panel complete including the following : switching off electric supply, Checking of mechanical system for proper functioning, replacing closing buffer, triping buffer (VMX type), V I connection gap check, motor coil resistance check, closing coil resistance check, spring charging cut off switch check, aux switch check, NO-NC states check, trip coil resistance check, testing details, timing test, oil value test, breaker timing test, connector resistance test, IR value test, HV test, mechanical and electrical mechanism check, counter reading check, shock observer check, pre close/ post close circuit check, test and service position limit switch check, breaker drive screw operation check, trip coil assemble operation check, mechanical latch . Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete including replacement of following spares all as directed, Unit rate include two preventive maintenance and one break down during the entire period of work complete all as directed. (a) Control Fuse with link 32 A, - 12 Nos (b) Trip Netural close switch, - 01 No (c) Hooter 30 V DC - 01 No (d) Multifunction energy meter with KHW, KVAH, PF, HZ, KW etc - 01 No (e) Indicating LED lamp - 03 Nos Note:- (i) Maitenance of all HT VCB will be carried out as per maintenance schedule (ii) Testing of above job to be carried out by engineers of authorised dealer/service centre. (iii) Test report must be submitted by Contractor before placing of RAR/ final bills.
Supply and Fix Battery bank panel of 2.0 mm thick sheet with powder coated of 30 volt for relay operation of VCB having 16 nos battery wet type of each capacity 2 Volts 100 Ah including compatible floot cum boost charging unit upto 32 amps charging complete all as directed.
Supply & fix for replacement of current Transformer , CT : Ratio : 200-100/ 5-5A. CORE - 1 :15 VA CLASS : 1. CORE- 2 :15VA CLASS 5P10. STC : 13:1KA 1 Sec. ILV : 12KV/28/75 KVP. SYSTEM VOLTAGE : 12KV. TYPE ; EPOXY RESIN CAST As Per IS -2705 .IEC- 60044 , suitable for Indoor VCB including proper Connection to BusBar and connecting with electric system such as Control Panel Complete all as directed . Make:- CG/ Kappa/ Laxmi/L&T/ Schneider/ABB/Siemens
Supply & fix for replacement of Potential Transformer , PT : Ratio : 11000/110 Volt 3 phase. CORE - 1 :15 VA CLASS : 1. CORE- 2 :15VA CLASS 5P10. STC : 13:1KA 1 Sec. ILV : 12KV/28/75 KVP. SYSTEM VOLTAGE : 12KV. TYPE ; oil type As Per IS -2705 .IEC- 60044 , suitable for Indoor VCB including proper Connection to BusBar and connecting with electric system such as Control Panel Complete all as directed. Make:-CG/Kappa/Laximi/L&T/Schneider/ABB/Siemens.
Supplying, installing, in replacement HRC fuses 16 Amps capacity complete all as directed. Make:- HPL/ AE//L&T/ Havells.
Supplying, installing, in replacement of HV rectifire operating Aux 30/110 volt AC/DC with NO NC complete all as directed. Make:- AREVA(Model No ERC-A-AOODC.OO) or equivalent of Schneider/L&T/C&S.
Supplying and installing in replacement, testing and commissioning plug in trip circuit supervision relay suitable for operation on 110 volts, as per sample complete all as directed.
Supplying, installing, in replacement of 220 Volt AC/ DC Motor 500 Watt complete all as directed. Make:- AREVA(Model No MVU00157-02/03) or equivalent of Schneider/L&T/C&S.
Supplying, installing, in replacement of Hooter complete all as directed. Make: L&T /ABB/ Schneider.
Supplying, installing, in replacement of VG 2R (Replacement of V207 for VCB Rating up to 1250A) complete all as directed. Make:- AREVA(Model No DRCVG2002-01) or equivalent of BE/BHEL
Supplying, installing, in replacement of -Phase Circuit Spout for 800A/1250A Panel - R/Y/B Phase sutable for 11 kV indoor VCB complete all as directed. Make: AREVA(Model No MEP-39-32187) or equivalent of L&T/C&S.
Supplying, installing, in replacement of TNC switch complete all as directed. Make: Secure/ AE/L&T/HPL
Supplying, installing, in replacement of Digital Volt Meter 33/11 KV Aux supply 110 Volt complete all as directed. Make: Secure/ AE/L&T
Supplying, installing, in replacement of support Post insulator 12 KV complete all as directed. Make: Secure(Model No MVIB00172-01) or equivalent of AE/L&T/ABB.
Supplying, installing, in replacement of Aux connector complete all as directed. Make: Secure(Model No MVIE00114-02) or equivalent of AE/L&T/ABB.
Supplying, installing, in replacement of LED indicator lamp 30 Volt AC/DC complete all as directed. Make: HPL/ AE/L&T
Supplying, installing, in replacement of closing coil CN1346 30 Volt complete all as directed. Make: AREVA(Model No ECO39SN133900FN) or equivalent of L&T/Schneider
Supplying, installing, in replacement of connector complete all as directed. Make: HPL/Schneider/L&T
Supplying, installing, in replacement of space heater with thermostate complete all as directed. Make: AREVA/ Schneider/ L&T/ ABB
Supplying, installing, in replacement of earth leakage relay with percent setting along with adaptive coil accuracy 97 % complete all as directed. Make: Schneider/ L&T/C&S
S&F in replacement of Feeder protection relay with 3 Over current and one earth fault protection type with indications of trip, alarm, Warning and Healthy with setting of 1-99%, complete all as directed. Make : Schnider(Model No P111) or equivalant L&T, C&S
Supply laying testing & commissioning in replacement of XLPE cable insulated screen PVC bedded galvnazied steel strip on wire armoured electric power cables heavy duty with copper conductor 1.1 KV earthed system cross sectional area 2.5 SqmmX 12 core laid in trenches or passing through pipe or fixed to wall complete all as directed.
Supply and fill up transformer oil as in topping up/refilling of transformer having dielectric strength not less than 60 KV at 2.5 mm gap conforming to IS-335 by heating up and after filtration complete all as directed.
Supply, installation, fitting and fixing of maintenance free tripod earthing system for ESE technology lightening conductor of range 107 mtr radius (3 Nos chemical earthing , per set) of 17mmx3 mtr steel high tensile EN-8D Grade Rod with copper bonding of minimum 250 microns, having pre-welded copper bonded connection clamp at top and M17 threaded at bottom for coupler attachments clamp head assembly, prewelded and copper bonded connection clamp, with lightening stroke chamber 6 digit non-re-settable electromechanical display and connecter base having provision to connect external copper cables of 50 sq mm 15 Rm & strips back fill compound (BFC) 50 Kg highly conductive resistivity lowering ground enhancement compound tested & certified by National Test House (Govt of India Lab) as per IEC 62561-7 and ASTM G57-06 for a resistivity of 0.244 ohms- mtr with advanced heavy duty polyplastic earth inspection pit cover having unique desingn and lockable made of high grade polypropylene complete all as directed. Note:-Test report must be submitted by contractor before placing of RAR / Final bill. Make:- LEESAS GROUP/ Indelec/ ABB/ True Power
Excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for laying under ground cables/erection of pole and getting out in hard/dense soil, complete all as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as directed.
Removal of excavated surplus material (Soil) to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as directed.
Sand filling in cable trenches for cable protection with clean dry sand unwashed including gently put in trences complete all as directed.
S&F for old size brick well burnt, laid flat, for cable protection complete all as directed.
S&F cable jointing kit for 11 KV grade cable for end termination heat shrink type jointing complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as directed.
S&F cable jointing kit for 11 KV grade cable for straight through heat shrink type jointing complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as directed.
Supply and install HT 11 KV outdoor type polymer gang operated air break switch suitable for horzontal or vertical mounting fixed type complete with 9 insulators of rating upto 400Amps complete all as directed.
Hiring of cable fault detector to detect exact position of fault for XLPE, HT cable, 11KV grade heavy duty aluminium conductor upto 95 sqmm 3 core including and for transporting chagres etc complete all as directed.
Attending any breakdown immiediately of 63 kVA to 500 kVA transformer by OEM service engineer to check and repair /replace any spares related break down and make the power transformer serviceable with in 24 Hours complete all as directed at site. Note : (i) Spares will be paid separately under relative items. (ii) Checking of all electrical connection for its proper tightness. (iii) Proper care shall be taken to isolate the supply and it shall be ensured that repairs are carried out on No LIVE switch gears. (iv) Each switch gear/Load break switch/breaker shall be counted as a separate unit for the purpose of measurement. (v) A sum of Rs.500.00/Hr will be recovered from contractor in case of not attending the break down by service engineer and not rectified defect with in 24 Hrs.
Disconnecting and opening transformer 63 KVA to 100 KVA, 11 KV/433 volts indoor /outdoor type of any make after unscrewing nuts /bolts, screws and connected accessories such as breather conservator tank, temperature gauge for replacement of defective HT /LT coils ,defective parts (payment of defective parts to be replaced shall be measured and paid separately), reassembling after replacing the defective coils /defective parts and replacing the top gasket sheet and other insulating packing materials and testing including taking out, handling of distribution transformer of any size any capacity to workshop & back to the installation complete all as directed. Note :- (i) The reassembling element covers the assembling of parts not to be changed whereas for the rest it shall be the part of the item being replaced. (ii) Cost of transportation of transformer is deemed to be included in quoted rate. (iii) Test report must be submitted by contractor before placing RAR/final bills.
All as per item no 41 here-in-before but 150 KVA to 500 KVA complete all as directed.
M&L for rewinding of transformer of any capacity LT coils using the same gauge of super enameled copper winding wire including replacing the old paper tape insulation, necessary insulation packing’s/ paper insulation etc with replacement of crap tape, prosen sheet, silphase brazing rod, HT block, LT block etc complete all as directed. Note –(i) The coil replaced shall have same number of turns, gauge, insulation value matching as per manufacture’s design. Measurement shall be made of winding wire consumed. (ii) Test report must be submitted by contractor before placing RAR/final bills.
M&L for rewinding of transformer of any capacity HT coils using the same gauge of super enameled copper winding wire including replacing the old paper tape insulation, necessary insulation packing’s/ paper insulation etc with replacement of crap tape, prosen sheet, silphase brazing rod, HT block, LT block etc complete all as directed. Note –(i) The coil replaced shall have same number of turns, gauge, insulation value matching as per manufacture’s design. Measurement shall be made of winding wire consumed. (ii) Test report must be submitted by contractor before placing RAR/final bills.
S&F lightening arrestor non linear, pole type MCOV 11 KV discharge capacity 65 KA, with all fittings suitable for 11 KV electric working pressure including strap, bolts, nuts and washers etc complete all as directed. Make: BHEL / Jaipuria / Rashtriya/ Racycan
Earthing complete including taking down of old one with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts, check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No-3 of SSR- Part-1 connected to earth strip all as specifed or indicated including testing on completion and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm diia meduim grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer complete all as directed.
Supply laying testing and commissioning in replacement XLPE cable insulated screen PVC bedded galvnazied steel strip on wire armoured electric power cables heavy duty with aluminium conductor 11 KV earthed system cross sectional area 95 SqmmX3 core laid in trenches or passing through pipe or fixed to wallcomplete all as and directed.
Excel Enterprises
Associated Engineers
M/S Akash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .