Sh Rakesh Jha, IDSE, SE, CWE
HQ CWE Bikaner Bikaner Mil Stn
Repair/Maintenance of VCB, RMU and allied works at Mil Stn Kanasar under GE (N) Bikaner
2026_MES_794016_1
CA No CWE BKN-Token No 70/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Kanasar
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (N) Bikaner
₹50,000
Yes
15 Oct 2026
15 Oct 2026
12 Nov 2026
15 Oct 2026
5 Nov 2026
29 Oct 2026
15 Oct 2026 - 22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for preventive maintenance / repairing by opening and taking out the Vacuum Circuit Breaker (VCB) 11KV 630 Amp, type VMX from panel and carry out the general maintenance such as oiling & greasing the mechanical parts, motor, gear, lever spring, operating rod, cleaning the female contacts, tightening of nuts and bolts, cleaning the male and female contact of panel, oiling the bus bar shutter, checking the AC/DC wiring, circuit including control fuses and circuit jack, on/off push button, indicating lamp, voltmeter, ammeter, PF meter, replacement of minor parts (where required) and testing after re-inserting the VCB in panel complete all as specified and as directed by Engr-in-charge. The new replaced parts shall be measured and paid separately under appropriate item (i.e. 2 to 25) of Sch 'A' as supply only. | 28 | Each Job | 101 | ₹2,828 |
| 2 | Supply only Electromechanical Master trip relay Hand reset type Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220V complete all as specified and as directed by Engr-in-charge. | 4 | Each | 104 | ₹416 |
| 3 | Supply only Over current and earth fault relay Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220V with breaking capacity 2KVA complete all as specified and as directed by Engr-in-charge. | 5 | Each | 104 | ₹520 |
| 4 | Supply only Numerical control over current earth fault IDMT relay CGI-14No crompton or equivalent, suitable for the existing VCBs complete all as specified and as directed by Engr-in-charge. | 2 | Each | 120 | ₹240 |
| 5 | Supply only Anti Pumping Relay for vaccum circuit breaker as per existing make & model and should not be plug in type & should have suffcient number of contact complete all as specified and as directed by Engr-in-charge. | 4 | Each | 123 | ₹492 |
| 6 | Supply only Tripping coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt , Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed by Engr-in-charge. | 6 | Each | 123 | ₹738 |
| 7 | Supply only Closing coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt,, Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed by Engr-in-charge. | 6 | Each | 132 | ₹792 |
| 8 | Supply only Resin cast/Dry type Potential transformer having 3 phase,Ratio 11000/√3V / 110√3V,vector group Star/Star with neutral earthed, burden/class: 100VA/0.5, Fixed type with HRC fuse protection, with IS: 3156-1992 complete all as specified and as directed by Engr-in-charge. | 1 | Each | 133 | ₹133 |
| 9 | Supply only Resin cast, Dual ratio,Indoor type Current Transformer for breakers having ratio 100-50/5-5A, Burden value 15VA both for protection & metering core, Short-time circuting rating 25kA for 3 sec , Protection Core 5P10 complete all as specified and as directed by Engr-in-charge. | 1 | Each | 133 | ₹133 |
| 10 | Supply only HT vaccum interrupted assembly bottle with flex connection suitable for VMX type VCB 630 Amps capacity for RYB phases complete all as specified and as directed by Engr-in-charge. | 3 | Each | 133 | ₹399 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender70.pdf
Tender Documents • 1.33 MB
BOQ_890503.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .