| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.9 LAccepted-AOC RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹22.6 L+₹1.9 L (9.36%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹22.8 L+₹2.2 L (10.5%)Rejected-Finance | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹24.4 L+₹3.8 L (18.2%)Rejected-Finance | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹24.9 L+₹4.3 L (21.0%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Sept 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR AND MAINTENANCE OF STREET LIGHTS LT CABLE POLE BOX ASSEMBLY TIMER PANELS AT KABUL LINE BAIRD PLACE KOTWALI LINE CEDZ OFFICE CDA ARMY AND ASSOCIATED AREA UNDER AGE SLDC ES AND REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION REWI
2024_MES_669622_1
GE ELECT/D-20/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER NIT
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹90,000
Yes
28 Nov 2024
2 Sept 2024
24 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil for foundation of poles, stays, laying of cables, etc complete all as specified and as directed by the Engg-in-Charge.
Returning filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and as directed by the Engg-in-Charge.
Removing excavated surplus hard/dense soil to a distance not exceeding 50 m and depsoiting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by the Engg-in-Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc complete all as specified and as directed by the Engg-in-Charge.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as specified and as directed by the Engg-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm, 2 core nominal cross section in service connections complete all as specified and as directed by the Engg-in-Charge after removing the old/damage cable.
Supply and laying XLPE insulated heavy duty electric, un-armoured cables 16 sqmm 4 core with aluminium conductor, 1100 volts grade for necessary connection with suitable lugs & fixing arrangement with necessary clamps & cable glands etc complete all as specified and as directed by the Engg-in-Charge after removing the old/damaged cable.
S&F in replacement KIOSK Box weather proof made up of one piece mounted on SMC base and door pole mounted hinged door of size 333x233x120 mm outside and 300x200x105 mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp fuse grip with base for controlling the steet light fitting and FL clamps 30x4mm with necessary MS nuts bolts and washers and including applying two coasts of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface and including embassing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and as directed by the Engg-in-Charge.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 mm bore and making good both ends complete all as specified and as directed by the Engg-in-Charge.
Supply and laying in replacement 40 mm dia galvanized iron mild steel tubing, light grade including all fitting for cable protection etc laid in floor/trenches or fixed to poles with clamps etc complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement LED street light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement New Generation Energy saving LED flood light 100 watt powder coated PDC aluminium body with toughened glass visor, equipped with secondary optical PC lence Efficacy >110 Lm/w, available in 5700K CCT, IP66 protection complete all as specified and as directed by the Engg-in-Charge.
M&L in replacement for bracket made out of GI pipe 40 mm dia medium grade, 1.2 meter long bent to shape fixed with 40x 6 mm thick MS flat irom clamps, nuts bolts complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement of 3 pole power contactor ML-6 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement of 3 pole power contactor MNX-110 mounted on any type/ description LT panel/feeder pillar/wall after taking down old existing un-serviceable contactor complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement Analog Time switch, 240 Volt AC, 50 Hz, mounted on any type/ description LT panel/feeder pillar/wall after taking down old existing un-serviceable timer switch complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement Driver suitable for LED Street light 45-60 watt of any make complete all as specified and directed by Engr In charge.
All as per item No 17 but of Capacity 60-120 watt LED Flood Light complete all as specified and as directed by the Engg-in-Charge.
Pruning/trimming the branches of trees if any along LT overhead line/ street light pole, 3 mtr on all side below/above/sides of LT overhead line and removing the same upto 150 mtr away each span not exceeding 50 mtr complete all as specified and directed by Engineer-in-Charge. Note:-The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
Preparation of old painted surfaces of Steel tubular LT poles, any height including cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting of complete poles with one coat of aluminium paint from 2.1 m above ground level to top of pole including cross arms and protection pipe and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and as directed by the Engg-in-Charge.
Preparation of old painted surfaces of LT PCC poles for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminium paint and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws confirming 410 SP-22 (8.5 metres long) incl complete all as specified and as directed by the Engg-in-Charge.
M&L for PCC Type D-2, 1:4:8 (using 40mm graded aggregate) as in foudation or mass concrete complete all as specified and as directed by the Engg-in-Charge.
M&L for plain cement concrete type B1, 1:2:4 (20 mm graded crushed trap stone aggregate) in coping and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including use of form work complete all as specified and as directed by the Engg-in-Charge.
M&L for cement concrete type B-1, 1:2:4, 50 mm thick (using 20 mm gradded aggregate) for floors and paving or similar works complete all as specified and as directed by the Engg-in-Charge.
M&L for painting of timer panel boards out door/in door of size above 5.00 Sqmm floor/leg mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint including repair of panel door's nut & bolts/hinges etc for smooth functioning to open and clsoe of doors complete all as specified and as directed by the Engg-in-Charge.
M&L in replacement Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized strip 32 x 6 mm, by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as specified and as directed by the Engg-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Taking down carefully copper/ aluminium point wiring of light, fan, socket 5/15Amps or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards/sunken box and making good the disturbed of wall/ceiling/floors etc so as to match with the existing surface complete all as specified and as directed by the Engg-in-Charge.
Taking down carefully sub main wiring including copper/ aluminium/ GI earth continuity conductor and making good the disturbed surfaces complete all as specified and as directed by the Engg-in-Charge.
Taking down main/sub main MCB DB with MCBs of any size and capacity along with teakwood boards and including all fittings/furniture carefully and making good the disturbed surfaces complete all as specified and as directed by the Engg-in-Charge.
M&L for point wiring for one light point controlled by one way switch complete with 1100 Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and as directed by the Engg-in-Charge.
(a) For one light point controllled by one switch
(b) For one ceiling fan/Exhaust fan point controllled by one switch
(c) For one bell point controlled by one switch
(d) For one 5 Amp independent socket point controlled by one switch
(e) For one 5 Amp socket point controlled by one switch on same board
M&L for point wiring for 15Amp independent socket point controlled by one switch complete with 1100Volts grade 2.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable (Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 2.5 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and as directed by the Engg-in-Charge.
S&F switch flush type, single pole, one way, 6Amps, 240 Volts, white finish complete all as specified and as directed by the Engg-in-Charge.
S&F switch flush type 16Amps, 240 Volts, single pole white finish complete all as specified and as directed by the Engg-in-Charge.
S&F bell push, 5Amps, 240 Volts white finish complete all as specified and as directed by the Engg-in-Charge.
S&F socket outlet, 5 pin, 6 Amps, flush type, white finish complete all as specified and as directed by the Engg-in-Charge.
S&F socket outlet, 2 in1, 3 pin, 6/16 Amps, flush type universal, 240 Volt, white finish complete all as specified and as directed by the Engg-in-Charge.
S&F electronic socket size, rotary, 5 speed step type regulator, 220-230Volts white finish complete all as specified and as directed by the Engg-in-Charge.
S&F call bell, ding dong type, AC 230 Volts single pole complete all as specified and as directed by the Engg-in-Charge.
S&F ceiling rose, surface bakelite of size 65mm x 20mm three terminals complete all as specified and as directed by the Engg-in-Charge.
S&F lamp holder insulated body with back plate suitable for angle/ batten fitting complete all as specified and as directed by the Engg-in-Charge.
S&F the following double door metallic sheet metal enclosure for DB when MCBs to be used 240 Volts with 100Amps rated bus bar complete fixed properly on/ in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed by the Engg-in-Charge.
(a) SPN 4 way
(b) SPN 8 way
S&F sheet metal enclosure double door, vertical type for DB’s when MCB’s to be used triple pole and neutral 4ways, 415volts with 100amps rated bus bar fixed sunk/ flush to wall complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement MCB SP 240volts, 6Amp to 32Amp, 10KA capacity having C-series connected with suitable lugs including testing and commissioning complete all as specified and as directed by the Engg-in-Charge.
All as per Srl Item No.45 above but SP 40 to 63 Amps complete all as specified and as directed by the Engg-in-Charge.
All as per Srl Item No.45 above but SPN 16 to 32 Amps complete all as specified and as directed by the Engg-in-Charge.
All as per Srl Item No.45 above but TPN 40 to 63 Amps complete all as specified and as directed by the Engg-in-Charge.
M&L for sub main wiring with two single core PVC-FR insulated unsheathed stranded copper conductor cable of size 4Sqmm fixed/ drawn through and including heavy duty PVC casing/ capping with accessories with one single core PVC-FR insulated unsheathed stranded copper conductor cable of size 4Sqmm as a continuous earth wire complete all as specified and directed. Note: Two single core cables and one run of earth copper conductor/ casing capping will be measured and paid as one unit length.
S&F switch Modular one way 6A white finish complete all as specified and as directed by the Engg-in-Charge.
S&F modular switch Bell push 6 Amps white finish complete all as specified and as directed by the Engg-in-Charge.
S&F modular cover plate with frame of 4 module complete all as specified and as directed by the Engg-in-Charge.
S&F modular metal flush box of of 4 module complete all as specified and as directed by the Engg-in-Charge.
S&F socket outlet 2 in 1, 6A & 3 Pin 5A (multi purpose) modular type white finish complete all as specified and as directed by the Engg-in-Charge.
S&F socket outlet 2 in 1, 16A & modular type white finish complete all as specified and as directed by the Engg-in-Charge.
S&F switch modular type 16A multi purpose white finish complete all as specified and as directed by the Engg-in-Charge.
S&F stepped type electronic Fan Regulator MODULAR type white finish complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement LED tube light fittings, Batten type 1x20 W, 230V, 6000K complete all as specified and as directed by the Engg-in-Charge.
S&F in replacement LED tube light fittings, Batten type 1x10 W, 230V, 6000K complete all as specified and as directed by the Engg-in-Charge.
S&F LED Bulb 10 watt complete all as specified and as directed by the Engg-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3097812)
Rajindera Enterprises (BID ID -3108282)
ALLIED CONSTRUCTION (BID ID -3108515)
mayur enterprises (BID ID -3098805)
Microsys Controls India (BID ID -3108498)
Ridhi engineers and builders (BID ID -3107225)
Vijay Electricals (BID ID -3107861)
DS CONSTRUCTION (BID ID -3106955)
KISHORE ENTERPRISES (BID ID -3107532)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .