| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.9 L+₹3.0 L (9.58%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Smruti Construction L2 | Santosh Popatrao Sarode L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium point wiring (light, Fan, socket or power) complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of walls, ceilings and floors etc complete all as specified and directed. | 448 | PER POINT | 40 ₹17,920 | 20 ₹8,960 Lowest |
| 2.00 | Taking down unserviceable DB's any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed. | 27 | EACH | 55 ₹1,485 Lowest | 100 ₹2,700 |
| 3.00 | Taking down unserviceable MCBs/Isolator/DP any rating and size complete all as specified and directed. | 113 | EACH | 11.6 ₹1,310.8 | 10 ₹1,130 Lowest |
| 4.00 | Taking down old/unserviceable light fitting from wall, ceiling etc any type complete all as specified and directed. | 879 | EACH | 25 ₹21,975 | 20 ₹17,580 Lowest |
| 5.00 | Material and labour for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through & including PVC casing and caping, medium duty (ISI marked) on wall, ceiling with GI screws, rawl plugs with all fittings including tees, junction boxes & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5sqmm (nominal area) complete all as specified and directed.
(a) For one light point controlled by one single pole switch. | 70 | PER POINT | 742 ₹51,940 | 680 ₹47,600 Lowest |
| 5.01 | (b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch. | 45 | PER POINT | 742 ₹33,390 | 680 ₹30,600 Lowest |
| 5.02 | (c) For one 3 pin, 5 Amp socket oultet on independent board. | 40 | PER POINT | 742 ₹29,680 | 680 ₹27,200 Lowest |
| 5.03 | (d) For one 3 pin, 5 Amp socket oultet on same board with other switches. | 35 | PER POINT | 161 ₹5,635 | 150 ₹5,250 Lowest |
| 5.04 | (e) For one bell/buzzer point controlled by one bell push button on independent board. | 20 | PER POINT | 742 ₹14,840 | 680 ₹13,600 Lowest |
| 5.05 | (f) For one light point controlled by two 2-way switches. | 6 | PER POINT | 890 ₹5,340 | 750 ₹4,500 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Oct 2025, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE 25
GE I R AND D GIRINAGAR PUNE 25
REP REPL OF ELECT FITTING AND FIXTURES DBS WIRING SUB MAIN WIRING EATHING ETC REP OVERHAULING OF CEILING FAN EXAUST FAN WALL FANS AIR CIRCULATORS GEYSER SUMMER COOLING APPLIANCES AT CERTAIN BLDS OF TECH RESI AREA TYPE IV V QTRS AT VRDE AHMEDNAGAR
2025_MES_729677_1
GE I R AND D GNR TOKEN 64 OF 2025-2026 (8925)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D GIRINAGAR PUNE 25
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 25
₹70,000
Yes
9 Dec 2025
6 Sept 2025
15 Oct 2025
6 Sept 2025
13 Oct 2025
22 Sept 2025
6 Sept 2025 - 13 Sept 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .