Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance AT PO CHEDABHUMI ROAD 3RD LINE LALSINGI MANIKA SAHI PS BHANJANAGAR PIN 761126 DIST GANJAM ODISHA | BHANJANAGAR | GANJAM | ODISHA | 761126 | -5.99% | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance | -4.50% | ₹1.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.3 CrAdmitted-Finance | +2.00% | ₹1.3 Cr | L3 | Admitted-Finance |
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
16 Apr 2026, 5:30 pmClosed
Chief Construction Engineer
Southern Circle (RandB), Courtpeta, Berhmapur-760004, Ganjam
Construction of Bar Association - Cum - Canteen Building at Sorada in the district of Ganjam for the year 2025-26.
2026_EICCL_127766_4
CCE, SC (RandB)-BAM-17/2025-26
National Competitive Bid
Civil Works - Buildings
180 days
Sorada Ganjam
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.3 L
Yes
12 May 2026
1 Apr 2026
17 Apr 2026
1 Apr 2026
16 Apr 2026
1 Apr 2026
1 Apr 2026 - 15 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation of foundation in hard soil within 50 m linital lead and 1.50m initial lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. | - | Cum | - | - |
| 2 | Filling in foundation and plinth with excavated earth including watering and ramming as per OPWD Specification and direction of the Engineer-In-Charge. | - | Cum | - | - |
| 3 | Filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalty, taxes of all materials with all labour, T&P etc., complete as per the OPWD Specification and direction of the Engineer-in-charge. | - | Cum | - | - |
| 4 | Removal of excavated earth by mechanical means for site leveling, foundation, pits, trenches and other civil works upto and including 1.5 mter lift and stacking the soild upto a lead of 100 meter and including dewatering, removing slush, shorting and shutterng (as required) completeas per the OPWD Specification and direction of the Engineer-in-charge. | - | Cum | - | - |
| 5 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the OPWD Specification and direction of the Engineer-in-charge. | - | Cum | - | - |
| 6 | Fly Ash Brick masonry in C.M. (1:6) using 9" size using in F&P of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per the OPWD Specification and direction of the Engineer-in-charge. | - | Cum | - | - |
| 7 | Fly Ash Brick masonry in C.M. (1:6) using 9" size using in Super Structure of 23cmx11cmx8cm size brick having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per the OPWD Specification and direction of the Engineer-in-charge. | - | - | - | - |
| 8 | Ground Floor | - | Cum | - | - |
| 9 | Head room | - | Cum | - | - |
| 10 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.. But excluding cost and conveyance of HYSD bar and binding wires and labour charges for straightening, cutting, bending etc. of HYSD Bar tying the grills and placing in proper position | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_586877.xls
BOQ • 1.19 MB
DTCN_BarAssn_Sorada.pdf
Tender Documents • 3.11 MB
Download all tender documents and submit your bid