| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.5 LAccepted-AOC GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | 1 | Accepted-AOC L1 | |
| 2 | 2₹24.9 L+₹18,157 (0.74%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹25.0 L+₹26,819 (1.09%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹26.5 L+₹1.8 L (7.23%)Rejected-Finance | 4 | Rejected-Finance Not L1 |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
18 Nov 2021, 6:00 pmClosed
CWE LUCKNOW
HQ CWE LUCKNOW
MAINTENANCE/SERVICING TO VCB/SF6 INCL OTHER CONNECTED WORK UNDER GE E/M LUCKNOW
2021_MES_473873_3
CWE/LKO/EM/T-35 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
class E category b(ii)
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹49,800
Yes
21 Dec 2021
30 Oct 2021
20 Nov 2021
30 Oct 2021
18 Nov 2021
6 Nov 2021
Amount
Prediodical serving VCB/RMUs/VCB SF6 of 11 KV rating in such as fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing of all moving parts,gas charging, tighting of all joints nut,bolt,washer, removing the moisture by jel/heating system,caliveration of relay & repair and replacement of defective components as per existing make/model/capacity of VCB/RMU/VCB SF6 incl connecting the all electrical connection and testing complete all as specified and directed.
Note - (i) The above job to be carried out by engineer of authorised dealer/service centre of concerned OEM. (ii) Replacing new items shall be measured and paid separately as supply only. (iii) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer/service centre. (iv) If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (v) Other part which is not included but requierd for functioning of equipment is included in the quoated rate &The contractor shall arrange for the standby supply for testing of relays,
Supply only closing coil as per existing make/model/capacity
Supply only triping coil as per existing make/model/capacity
Supply only relay as per existing make/moede/capcity
Supply only kit kat fuse as per existing make/model/capacity
Supply only spring charging motor as per existing make/model/capacity
Supply only insulator of VCB as per exising make/model/capacity/sape
Supply only digital volt meter as per existing make/ model/capcity
Supply only digital ammeter as per existing make/model/capacity
Supply only digital indicator lamp as per existing make/model/capcity
Supply only cast regin wound CT as per existing ratio/make/model/capacity
Supply only cast regin wound PT as per existing make/model/ratio/capacity
Supply only annaunciators as per existing make/model/capcity and size
Supply only spring charging machanisum as per existing make/model/capacity/size
Supply only copper finger contact as per existing size/capacity/model
Supply only cluster contact as per existing make/model/capacity
Supply only power card as per existing make/model/capacity
Supply only intruptter housing as per existing make/model/size/capacity
Supply only motor protection relay as per existing make/model/capacity
Supply only inter locking machanisum as per existing model/make/capacity
Supply only Tnc switch as per existing make/model/capacity
Supply only vacuum interupter as per existing make/model/capacity
Supply only vacuum contactor as per existing make/model/capacity
Supply only Power Pack units with maintenance free batteries in sheet metal enclosure as per existing make/model/capacity
Supply only high voltage fuse as per existing make/model/capacity
Supply only epoxy resin cast busbar spout bushing as per existing make/model/capacity
Supply only VCB panel spout as per existing make/model/capacity
Supply only VCB charging machanisum as per existing madel/make/capcity
Supply only charging handle gear type as per existing make/model/size
Supply only Elstein HFS panel heater 300 watt suitable for 11/33 kv VCB for removing the moisture
Supply only male/female contact as per existing make/model/capacity
Supply almstorm spot as per existing make/model/size/capacity
Supply only vacuum contact assy as per existing model/make/capacity/size
Supply only short & earth fault indicator as per existing make/model/size/capacity
Supply only phase sensor as per existing make/model/size/capacity
Supply only battery of RMU as per existing make/capacity
Supply only copper busbar of RMU as per existing size/sahpe
Supply only 400 series bolted type as per existing make/model
Supply only O ring 72x6 bushing 400 series bolted as per existing make/model
Supply only SF6 Gass cylinder (9 Kg)
Supply only shaft for operating handle as per existing make/model
Supply only 2PA machanisum w/o hex rod as per existing make/model
Supply only linkage between K and A as per existing make/model
Supply only push button as per existing make/model/capacity
Supply only bracket A mechanisum hldg 2 push butoons as per existing make/Model
Supply only 3 PKE mechanisum w/o Hex rod as per existing make/model
Supply only bracket for K machanisum as per existing make/model
Supply only bracket for CT MTG RMU RHS as per existing make/model
Supply only 24 KV VPIS cord as per existing make/model
Supply only capacitor unit VPIS 9-15 KV without cord
Supply only leak detector : type LS790B leak seeker as per existing make/model
Supply only pressure refilling equipment (KAR-6) as per existing make/model
Supply only ronis lock & key for RMU with Key A as per existing make/model
Supply only ronis key with hardware as per existing make/model
Supply only ronis key interlock of LBS with Key B as per existing make/model
Supply only ronis key interlock of LBS with Key C as per existing make/model
Supply only fuse holder assy as per existing make/model
Supply only terminal protector silcab for 11 KV as per existing make/model
Supply only T rhroud (new) for 11 KV as per existing make/model
Supply only monometer+gas desity switch as per existing make/model
Supply only electronic motor kit for C module-Mgvcl as per existing make/model
Supply only standard motorised kit for V model as per existing make/model
Supply only bracket for RMU (new indication) as per existing make/model
Supply only position inicator as per existing make/Model
Supply only indicator local as per existing make/model
Supply only monometer assy as per existing make /Model
Supply only motorised kit for C model
Supply only battery 12 VDC, 12 AH as per existing make/model
Disconnecting and taking out the unserviceable battery from battery bank any capacity supply and fix new lead acid maintenance free battery 2 volt 100 AH (HBL Make) or as per existing make/model/capacity including connecting of all battery in battery bank and testing upto satisfaction of engineer - in-charge complete as specified and directed.
Unnati Engineers
Ashirwad Contractor and Supplier
Prime power system
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .